Draper 115384 Instructions

Page 1
1
Universal Mounting Bracket
consists of a front and bac
Read instructions through completely before proceeding.
2
Follow instructions carefully. Installation contrary to instructions invalidates
warranty.
3
Do not lift case in center. Lift the ends simultaneously to avoid damage to case and surface. 4 Entire bottom of screen case should be unobstructed to permit access to bottom panels for making electrical connections or servicing. Motor end bracket must be located 1"-6" to right of access door. Idler end bracket must be located 6"-12" from right end of case. Failure to mount brackets as directed could cause the case to bow and result in damage to screen.
5
Keep case level when lifting and mounting. Screen should be installed level (using a carpenter’s level).
6
Nothing should be fastened to screen dowel or viewing surface. 7
Do not touch screen while in motion. 8
Operating switch (es) packed separately in screen carton. Do not discard with packing material.
9
Screen operates on 110-120V, 60 hz., .78 amp draw (1.35 with heavy duty motor). NOTE: Screen has been thoroughly inspected and tested at factory and found to be operating properly prior to shipment.
These instructions are meant as a guide only. They do not imply any responsibility on the part of Draper, Inc. for improper installation or faulty workmanship at the jobsite.
General:
When locating viewing surface and checking clearance for screen operation, remember surface is not centered in screen case: see dimensional drawings on reverse. All installations should observe these important criteria:
1
Screen should be positively and securely supported so that vibration or even
abusive pulling on viewing surface will not weaken installation.
2
Installer must insure that fasteners used are of adequate strength and suitable
for the mounting surface.
3
Entire bottom of case must be readily accessible after installation is complete.
Be sure the access door opens freely for adjustments and service.
4
Installer should make sure mounting brackets are flush with the sides of the
case to provide stability when hanging screen. Keep case level when lifting
and mounting.
5 Screens through 14' wide have 2 mounting brackets; wider screens have 3. Brackets should be located along case to line up with supporting beams or studding. Motor end bracket must be located 1"-6" to right of access door. Idler end bracket must be located 6"-12" from right end of case. Failure to mount brackets as directed could cause the case to bow and result in damage to screen.
Please Note: Mount the case using the two end brackets first. If a center bracket is provided, mount it last. The center bracket is designed to prevent sagging of the case, and must be mounted so that it is level with the others and does not force the screen case up.
6
Make sure the top of the screen case's bottom board at no point touches the
roller/viewing surface.
7
Do not use screen case to support adjacent sections of ceiling.
8
If trim pieces must be attached to case, do not permit screws to pro trude
through ¾" wall of case. Do not attach trim with nails.
9
If case is painted, viewing surface slot must be shielded to protect viewing
surface from paint splatters and overspray.
Do not seal unit in ceiling until electrical connections have been made and screen has been operated successfully. Screen must always be installed level so that fabric will not roll incorrectly or wrinkle.
Please Note: The Rolleramic is not available with the TorkStar Utility Line Set.
Wall Installation—
Brackets should fasten to studding or other structural supports within wall.
Suspended Installation—
Chains should be attached to solid beams or rafters above screen. If possible, screen mounting brackets should be positioned so chains hang vertically. Turnbuckles should be connected between chains and mounting brackets. After screen has been suspended, turnbuckles should be adjusted so that screen hangs level.
Recessed Installation—
Recess should be constructed to fit screen case with brackets (see “Case Dimensions” on back page). Design recess so that entire bottom of screen case is unobstructed to permit access to bottom panel, screen roller and surface for servicing if required.
Installation/Operating Instructions
Rolleramic Electric Projection Screen by Draper
Caution
Hanging Screen
Screen operates on 110-120V, 60 hz. AC, .78 amp draw (1.35 with heavy duty motor). Screens are shipped with internal wiring complete, with all switches (fully boxed) and a wiring diagram. Wire connecting screen to switch (or switches) and switch to power supply should be supplied by installer. Wires should be connected following the wiring diagram provided, and all wiring should comply with local and national electrical codes. All operating switches should be “Off” before power is connected.
Remove all packing before attempting to operate screen. When screen is first operated, be cautious! Cycle unit down and up several times to confirm satisfactory operation. 110-120V Single Station Control — 3-position up-off-down switch permits operation to be stopped at any point. Factory adjusted limit switches automatically stop screen when fully down or fully up. 110-120V Multiple Station Control — Switches are similar in appearance to 110­120V Single Station Control. Screen stops when switch is released and may be restarted in either direction. Factory adjusted limit switches stop screen automatically when fully down or fully up. 24V Control — Three-button up-stop-down switches stop at any point desired, operate in any sequence. Factory adjusted limit switches automatically stop screen when fully down or fully up. Key Operated Switching — Two kinds of key-operated switches are optionally available with this unit.
1
The key-operated power supply switch controls power to the screen and switches. When it is “off”, the switches will not operate screen. Key may be removed from the switch in either “on” or “off” position.
2
A three-position key switch permits the screen to be operated directly by key. In this case, the screen’s operator must always have a key. RS232/Ethernet—Serial communication and network communication optionally available with wall switches, RF or IR remote.
Please Note: Screen limits are factory set for optimum performance of the screen. A procedure is outlined below for minor tweaks, but any adjustment of these limits may negatively affect the flatness of the screen surface and could also void the warranty. Please check with Draper prior to resetting screen limits.
CAUTION: Always be prepared to shut screen off manually when new adjustment is being tested. Screen may be severely damaged if viewing surface is allowed to run too far up or too far down.
CAUTION: Be sure all switches are in “off” position before adjusting limit
switches.
CAUTION: Do not loosen coupling setscrews from the roller shaft, or the screen surface will rapidly unroll and fall. If setscrew must be loosened actions should be taken to prevent the roller from turning. Adjusting “fully up” position — “Up” limit switch is located on right side of
limit switch assembly, immediately behind access door to case. Right hand, hex head machine screw contacts limit switch button to shut screen off. Turning this machine screw clockwise will allow surface to run farther up into case. Turning it counterclockwise will cause screen to stop sooner, farther out of the case. Adjusting “fully down” position — “Down” limit switch is located on left side of limit switch assembly, immediately behind access door to case. Left hand, hex head machine screw contacts limit switch button to shut screen off. Turning this machine screw clockwise will allow surface to run farther down before stopping. Turning it counterclockwise will cause screen to stop in a less extended position. At no time should fabric be unrolled far enough to expose any part of screen roller. Make all adjustments in small increments, and be sure nut on machine screw is tight against steel limit switch support before closing access door.
may be suspended from above,
or mounted to wall. Each bracket
bolted together. 2 supplied on
3 supplied on larger screens.
Electrical Connections
Operation
Adjustments
k piece
screens up to 14' x 14'.
Conduit connection
on left end of case.
Case
Viewing Surface
Copyright © 2015 Draper Inc. Form Rolleramic_Inst15 Printed in U.S.A.
Motor end bracket must be located 1"-6" to right of access door. Idler end bracket must be located 6"-12" from right end of case. Failure to mount brackets as directed could cause the case to bow and result in damage to screen.
If you encounter any difficulties installing or servicing your Rolleramic screen, call your dealer or Draper, Inc., Spiceland, Indiana, (765) 987-7999, or fax (765) 987-7142.
Page 2
Conduit connection
L = W+24" (through 12' x 12')
L = W+30" (over 12' x 12')
Through 12' x 12' 14¾"
Over 12' x 12' 21¼"
Access
Door
Bottom board
Case
¾" thick
4" - 4
1
/8"
Opening for fabric
Bottom
Front
Fabric width – W
Screen surface
45/8"
91/8"
91/8"
9
5
/8"
9
5
/8"
11
1
/2"
1"-6" from
access door
6"-12" from
case edge
Rolleramic by Draper
Single Station Control
Junction box at left end of screen
Internal Screen Wiring
White (Common)
Red (Down)
Black, or Blue (Up)
Green (Ground)
Dashed wiring by electrician
Control switch
Single gang box by others Min. 4" x 2 1/8" x 1 7/8" deep
Blue
Black
Red
Location of key operated on-off switch if furnished
To 110-120V Line
Multiple Station Control
Junction box at left end of screen
Internal Screen Wiring
White (Common)
Red (Down)
Black, or Blue (Up)
Green (Ground)
Dashed wiring by electrician
Red
Red
Black
Blue
Blue
Cap off with wire nut and tape
Black
Red
Blue
Black
Single gang box by others Min. 4" x 2 1/8" x 1 7/8" deep. 3 shown. More or less equally
feasible. Location of key operated on-off switch if furnished
To 110-120V Line
For suspended mount.
For wall mount
63/8"
13/8"
www
External LVC-IV - Single or Multiple
Wiring Diagram for Ambassador and Rolleramic
Case Dimensions
Rolleramic Mounting Bracket
Screens through 14' wide have 2 mounting brackets; wider screens have 3. Brackets should be located along case to line up with supporting beams or studding. Motor end bracket must be located 1"-6" to right of access door. Idler end bracket must be located 6"-12" from right end of case. Failure to mount brackets as directed could cause case to bow and result in damage to screen.
Please Note: Mount the case using the two end brackets first. If a center bracket is provided, mount it last. The center bracket is designed to prevent sagging of the case, and must be mounted so that it is level with the others and does not force the screen case up. Make sure the top of the screen case's bottom board at no point touches the roller/viewing surface.
Rolleramic Wiring Diagrams
Please Note: Do not wire motors in parallel.
Page 2 of 2
INTERNAL SCREEN WIRING
White (Common)
(Motor Ground)
110-120 VAC
Red (Down)
Black (Up)
Green/Yellow
To
Line
GND
L1
Rolleramics over 12' x 12' have a blue wire lead instead of a black wire lead coming from the motor.
N
White -Common to screen & 110V-220V AC Neutral
Location of key operated on-off switch if furnished.
Low Voltage & Wireless Control
Red-to screen (directional)
Brown-to screen (directional)
Ye llow-to
Black-to
Green/Yellow (Ground)
Dashed wiring by electrician Low voltage wiring by others
110V-220V
AC-Hot
110V-220V
AC-Hot
.draperinc.com (765) 987-7999
Receiver
Button
FUSE - 3.15 AMP
250 VAC 5x20mm
3 Button Wall Switch DOWN - Black COM - White UP - Red
Electrically Straight
Data Cable to more
LVC-IV modules*
RS232/485
Inputs/Outputs
IR Eye Input
Low Voltage
Tr igger
3-28 VDC
Wall Switch
*A maximum of six (6) LVC-IV modules can be linked together.
Loading...