Installation/Operating Instructions
11/4"
1
1
/4"
2
1
/4"
5
/8"
2"
2"
Ceiling grid and tile
(by others)
79/16"
Envoy Electric Projection Screen by Draper
1 Read instructions through completely before proceeding.
2 Follow instructions carefully. Installation contrary to instructions invalidates
warranty.
3 Do not lift case in center. Lift the ends simultaneously to avoid damage
to case and surface.
4 Before removing screen from crate, check for damage and to make sure
all parts are included.
5 Entire bottom of screen case should be unobstructed to permit proper
operation of automatic trap door, and access to bottom panel for making
electrical connections or servicing.
6 Screen should be installed level (using a carpenter’s level).
7 Nothing should be fastened to screen dowel, viewing surface or auto matic
trap door.
8 Operating switch(es) packed separately in screen carton. Do not discard with
packing material.
9 Screen operates on 110-120V, 60 hz., 1.1 amp current draw.
NOTE: Screen has been thoroughly inspected and tested at factory and found
to be operating properly prior to shipment.
These instructions are meant as a guide only. They do not imply any responsibility
on the part of the manufacturer for improper installation or faulty workmanship at
the jobsite.
Hanging Screen
Caution
General:
When locating viewing surface and checking clearance for screen’s operation,
remember surface is centered in case. Screen is normally recessed above ceiling
and may be installed in a varie ty of ways. See typical installation detailed on page
2. Regardless of mounting method used, the following points apply:
1 Screen should be lifted into position only by the end mounting brackets.
Keep case level by lifting end plates simultaneously to prevent surface
damage. Draper provides eyebolts to use in hoisting the screen. Never
attempt to lift screen along its length.
2 Screen should be positively and securely supported so that vibration or even
abusive pulling on viewing surface will not weaken installation.
3 Installer must insure that fasteners used are of adequate strength and suitable
for the mounting surface chosen.
4 Entire bottom of case must be readily accessible after installation is complete.
5 Hinge on bottom board and particularly hinge on automatic trap door of screen
must be permitted to operate freely. Front and back of case must be straight—
not forced to warp or bow. Hinges must be free from mastic or paint buildup,
and doors must be unobstructed by ceiling tiles.
6 Do not use screen case to support adjacent sections of ceiling.
7 If trim pieces must be attached to case, do not permit screws to pro trude
through ¾" wall of case. Do not attach trim with nails.
8 If case is painted, slots around doors should be shielded to protect viewing
surface from paint splatters or overspray.
9 Do not seal unit in ceiling until electrical connections have been made and
screen has been operated successfully.
Electrical Connections
Screen operates on 110-120V, 60 hz., 1.1 amp current draw. Duty Cycle: ON 28
seconds /OFF 4 minutes.
Junction box is located just above bottom board near left end of screen. Bottom
board is held closed with flathead screws and may be opened with a Phillips
screwdriver. Automatic trap door is held shut by viewing surface and must not be
forced open. Removal of junction box cover plate exposes red, black and white
pigtail leads and green internal ground wire per wiring diagram attached.
Screen is shipped with internal wiring complete and control switch(es) fully boxed.
Wire connecting screen to switch(es) and switch(es) to power supply should be
furnished by installer. Connections should be made in accordance with attached
wiring diagram, and wiring should comply with National and local electrical codes.
All operating switches should be “off” before power is connected.
Operation
When screen is first operated, be cautious! If automatic trap door does not drop
open immediately when switch is flipped “down”, return switch to “off” and free trap
door and/or recheck electrical connections before proceeding. Cycle unit down and
up several times to confirm satisfactory operation.
110-120V Single Station Control — 3-position up-off-down switch permits
operation to be stopped at any point. Factory adjusted limit switches automatically
stop screen when fully down or fully up.
110-120V Multiple Station Control—Switches are similar in appearance to
110-120v Single Station Control. Screen stops when switch is released and
may be restarted in either direction. Factory adjusted limit switches stop screen
automatically when fully down or fully up.
24V Control — Three-button up-stop-down switches stop at any point desired,
operate in any sequence. Factory adjusted limit switches automatically stop screen
when fully down or fully up.
Key Operated Switching — Two kinds of key-operated switches are optionally
available with this unit. 1 The key-operated power supply switch controls power to
the screen and switches. When it is “off”, the switches will not operate screen. Key
may be removed from the switch in either “on” or “off” position. 2 A three-position
key switch permits the screen to be operated directly by key. In this case, the
screen’s operator must always have a key.
RS232/Ethernet—Serial communication and network communication optionally
available with wall switches, RF or IR remote.
Limit Adjustments
Please Note: Screen limits are factory set for optimum performance of the
screen. A procedure is outlined below for minor tweaks, but any adjustment
of these limits may negatively affect the flatness of the screen surface and
could also void the warranty. Please check with Draper prior to resetting
screen limits.
CAUTION: Always be prepared to shut screen off manually when new
adjustment is being tested. Screen may be severely damaged if viewing
surface is allowed to run too far up or too far down.
CAUTION: Be sure all switches are in “off” position before adjusting limit
switches.
The motor limit screws are normally located on the audience left of screen roller.
"DOWN" LIMIT ADJUSTMENT
To Reduce Screen Drop
1 Raise screen surface about 1' above desired setting and turn off.
2 Turn the DOWN limit screw (White or (I)) clockwise (three screw turns = ½ roller
revolution).
3 Test by running screen down and repeat steps 1 and 2 until desired position is
reached.
To Increase Screen Drop
1 Run screen to the down limit.
2 With the down switch on, turn the DOWN limit screw (White or (I)) limit screw
counterclockwise (three screw turns = ½ roller revolution) to increase drop.
3 Test by running screen up about 1' and back down to new down limit.
4 Repeat steps 2 and 3 until desired position is reached.
"UP" LIMIT ADJUSTMENT
Screen is Running Too Far Up
1 Lower screen surface about 1' below desired setting and turn off.
2 Turn the UP limit screw (Yellow or (II)) clockwise (three screw turns = ½ roller
revolution).
3 Test by running screen up.
4 Repeat steps 1 through 3 until desired position is reached.
Screen Needs to Run Up More
1 Run screen down about 1' and turn off.
2 With the up switch on, turn the UP limit screw (Yellow or (II)) limit screw
counterclockwise (three turns of screw = ½ roller revolution).
3 Repeat steps 1 and 2 until desired position is reached.
CAUTION: Do NOT allow the dowel to wrap up over the roller when the
screen is running up! This could damage the screen.
Caution: Do not remove the roller assembly from the case unless necessary for repairs. If the roller assembly is removed, be sure motor is fully
re-seated in the bracket, and re-secure it carefully with the motor retaining
spring or retaining clip, whichever is provided (see diagram below).
Copyright © 2014 Draper Inc. Form Envoy_Inst14 Printed in U.S.A.
If you encounter any difficulties installing or servicing your Envoy screen, call your dealer or
Draper, Inc., Spiceland, Indiana, (765) 987-7999 or fax (765) 987-7142.

Envoy by Draper
7 13/16"
7
9
/16"
1
/8"
7
9
/16"
Mounting
brackets
Support rods
by others
Incl. mtg.
brackets
Surrounding
ceiling
4
1
/16"
Single Station Control
Junction box at
left end of screen
Internal Screen Wiring
White (Common)
Red (Down)
Black (Up)
Green (Ground)
Dashed wiring
by installer
Control
switch
Single gang box by others
Min. 4" x 2 1/8" x 1 7/8" deep
Blue
Black
Red
Location of key
operated on-off
switch if furnished
To 110-120v Line
Multiple Station Control
Junction box at
left end of screen
Internal Screen Wiring
White (Common)
Red (Down)
Black (Up)
Green (Ground)
Dashed wiring
by installer
Red
Red
Black
Blue
Blue
Cap off with wire
nut and tape
Black
Red
Blue
Black
Single gang box by others
Min. 4" x 2 1/8" x 1 7/8" deep.
3 shown. More or less equally
feasible.
Location of key
operated on-off
switch if furnished
To 110-120v Line
Motor
Motor
Fabric Width + 15"
Viewing
surface
2"
2"
5
/8"
2¼"
7½"
Conduit connection
2" up on this end
1¼"
Ceiling grid and
tile (by others)
Ceiling
closure door
3¼"
7
9
/16"
Single Low Voltage Control
Multiple Low Voltage Controls
ST OP
To Motor
with
Built-In
Low Voltage
Back View
U
p
D
o
w
n
C
o
m
m
o
n
+
5V
DC
To Motor
with
Built-In
Low Voltage
Page 2 of 3
Case Dimensions/Method of Installation
Standard
Construction
Offset
Construction
Limit Adjustments (Built-in Low Voltage Motors)
Please Note: Screen limits are factory set for optimum performance
of the screen. A procedure is outlined below for minor tweaks, but
any adjustment of these limits may negatively affect the flatness of
the screen surface and could also void the warranty. Please check
with Draper prior to resetting screen limits.
CAUTION: Always be prepared to shut screen off manually when
new adjustment is being tested. Screen may be severely damaged if
viewing surface is allowed to run too far up or too far down.
1 Connect the ILT switch to the motor via the terminal blocks, or via the
modular port using four conductor modular cable. When using modu lar cable, the cable connectors MUST NOT be crimped in reverse, as
with standard telephone cable. (For a Dry Contacts Wiring Diagram,
see page 3.)
2 Set the slide switch to the lower position. Press and hold the DOWN
button on the switch to move the viewing surface to the desired lower
limit. If the screen moves in the opposite direction, release the DOWN
button and press and hold down the STOP button for four seconds.
This will reverse the operation of the UP and DOWN switches.
3 Move slider switch into center position. Wait a couple of seconds.
Please Note: If you move the slider switch from down to up in one
motion it sets the two limits in the same position.
4 Set the slide switch to the higher position. Move the viewing surface
to the desired upper limit by pressing and holding the UP button on
the wall switch.
5 Return the slide switch to the center position to return to normal
operation.
6 To set the viewing surface to an alternate format position, move the
viewing surface to the desired position and press the STOP button.
Press and hold the STOP button for at least three seconds to record
the position.
Please Note: Pressing and releasing the UP button on the switch will
move the screen to its upper limit. Pressing and releasing the DOWN
button will move the screen to its lower limit.
While the motor is in motion, pressing the STOP button for less than
two seconds will stop the viewing surface at its present position.
Once the motor is stopped, pressing the STOP button will move the
viewing surface to its alternate format position.
Pressing and holding the STOP button, when the motor is at rest or
in motion, for at least three seconds will record a new alternate format
position.
Slide
Switch
U
D
p
o
w
n
C
o
m
m
o
n
ST OP
Back View
+
5V
DC
To Motor
with
Built-In
Low Voltage
To Motor
with
Built-In
Low Voltage
Please Note: 5V DC
must be connected to
be able to set limits
using the wall switch.
POSITION
DOWN
UP
CENTER
Normal Operation
FUNCTION
Set LOWER limit
Set UPPERlimit
.draperinc.com
Wiring Diagrams—110-120V Motor and Quiet Motor
To 110-120V Line
Wiring Diagrams
Please Note: Do not wire motors in parallel.
with Built-in Low Voltage Controller
Internal Screen Wiring
White (Neutral)
Black
Green/Yellow (Ground)
Dashed wiring
by electrician
(765) 987-799
Data Cable
RJ-9
connector
Wall Switch,
RF or IR
Receiver,
or integrated
control system
To 110-120V Line
Dashed wiring
by electrician
Internal Screen Wiring
White (Neutral)
Black
Green/Yellow (Ground)
Data
Cables
RJ-9
connectors
Wall Switches,
RF or IR
Receivers,
or integrated
control systems

Envoy by Draper
connect from Aux to Eye).
ILT Switch-to-Motor—Dry Contacts or Data Cable connection
Please Note: This Splitter/
Motor Data Cable
plugged in here
Jack is located inside the
junction box of your Access
screen.
Page 3 of 3
Back of wall switch.
Please Note: Although both
Dry Contact and Data Cable
connections are shown, you
should only use one connection type per motor.
UPD
C
O
W
N
5V
O
M
M
O
N
COM
DWN
5V
UP
External Low Voltage and Remote Control
White-Common to screen & 110-120V AC Neutral
Red-to screen (directional)
Brown-to screen (directional)
Ye llow-to 110-120V AC-Hot
Black-to 110-120V AC-Hot
Green-Ground
Dashed wiring by electrician
Low voltage wiring by others
Eye Port for IR Eye, RF Receiver or LED
Wall Switch. For more than one of
these, a splitter is required.
3 Button Wall Switch
DOWN - Black
COM - White
UP - Red
Aux Port for connecting additional LV C-III
modules (up to six total can be linked-
Data Cables to switches or
to additional motors can
be plugged into any of the
three open jacks. If this is a
"Case First, Screen Later"
installation, plug the motor
cable into the jack indicated
in the drawing.
Red (Up)
Black (Down)
Green (Ground)
To
STOP
STOP
Control
Switches
24v DC
Location of key
operated on-off
switch if furnished
Line
Two-Way Serial Communication (RS232) with MC1
See separate Serial Communication-RS232 Instruction
sheet for enabling RS232 with the MC1.
White-Common to screen & 110-120V AC Neutral
Red-to Screen (directional)
Brown-to Screen (directional)
Program LED
Fuse
MC1
.draperinc.com
Black-Hot to 110-120V AC
Green/Yellow-Ground
Low Voltage Wiring by others
AC Wiring by electrician
RS232 Data FROM Control System
RS232 Data TO Control System
Signal Ground & Manual Switch Common
Manual Switch Down
Manual Switch Up
Eye Port for IR Eye. For RF Receiver or LED
Wall Switch, a Splitter and a Power Supply
is required. Plug RF Receiver or LED Wa ll
Switch and Power Supply into splitter, then
run cable from Splitter to MC1 Eye Port.
(765) 987-799
STOP
STOP
Control
Switches
24v DC
White (Common)
Red (Up)
Black (Down)
Green/Yellow (Gnd
Location of key
operated on-off
switch if furnished
To
110-120V
Line