DPA Microphone Type 4088 User's Manual

USER’S MANUAL
Type 4088
Cardioid Headband 4088
USER’S MANUAL
CONTENTS
Introduction 4 Placement 4 Cleaning Guide 5 Correct use of the Cardioid Headband 4088 6 Specifications 12 Accessories Available 14 Service & Repair 16 War ranty 16 CE Standard 16
Type 4088
Cardioid Headband 4088
4
5
CLEANING GUIDE
When mounting the 4088 on a performer, care should be taken to avoid sweat from running directly into the microphone. If the microphone gets filled up with water or sweat it will possibly turn deaf while the water is captured inside the microphone, behind the fixed protection grid.
Care of the microphone element
The microphone diaphragm is protected inside the microphone housing and there is no access to the diaphragm. It is well pro­tected from dust build-up and no attempt should be made to remove the protection grids to clean the diaphragm. The protec­tion grids are not removable, therefore no attempt should be made to clean the grid surface and extreme care should be taken not to clog the grids with make-up or other such substances.
If water or sweat has entered the micro­phone element, remove it by shaking the microphone gently. When it is left to dry out it will recover to its original specifications. Drying out the 4088 between exposures to humidity will also help to extend its lifetime. Do not use any kind of cleaning fluid. Use of ultra-sonic baths must be avoided. Avoid all kinds of spray or fluids, which contain chemical components to remove static electricity on or close to the microphone as this could cause damage to the electret layer.
Cleaning the microphone cable
Residue from tape, glue or make-up on the cable must be removed after use. Leaving these substances on the cable over longer periods of time may etch into the cable jacket and will make the cable more suscep­tible to breaks. The cable can easily be cleaned using organic oil (e.g. olive oil) or lukewarm, distilled water. Do not bend the cable or rub it harshly since this may stress the inner cores of the cable and cause them to break over time.
INTRODUCTION
To ensure optimal per formance of your 4088, please follow the simple instructions of care, maintenance, and mounting below. The Cardioid Headband 4088 from DPA is designed to be very resistant to humidity, moisture and sweat. Highly resistant mate­rials are used in construction of the micro­phones, to avoid damage by hostile fluids. In any case, it is still a good idea to keep the 4088 microphone away from any kind of cleaning, unnecessary exposure to water and cleaning fluids, and to keep the micro­phone element dry at all times.
PLACEMENT
In general, to ensure the optimal sound of the 4088, it must be mounted at about 2-3 cm (1 inch) from the corner of the mouth. Correct placement ensures that you avoid air noises from the nose and mouth from being captured by the micro-
phone. Avoid any contact with beards or moustaches. Please note that the 4088 is not designed for placement directly in front of the mouth. The sound timbre and pressure is as good at the corner of the mouth as it is directly in front of it. See the pictures below.
Keep dry
Correct placement of microphone at corner of mouth.
Correct placement of microphone at corner of mouth
Sweat stopper to hinder sweat reaching the capsule by running down the boom.
Sweat stopper