Dover Wilden Advanced Series, Wilden Advanced T1510, Wilden Advanced T810 Engineering, Operation & Maintenance

Page 1
T1510
Advanced™ Series METAL Pumps
Advance your process
Engineering Operation & Maintenance
WIL-11142-E-03
REPLACES WIL-11142-E-02
Page 2
TABLE OF CONTENTS
SECTION 1 CAUTIONS—READ FIRST! . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
SECTION 2 WILDEN PUMP DESIGNATION SYSTEM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
SECTION 3 HOW IT WORKS—PUMP & AIR DISTRIBUTION SYSTEM . . . . . . . . . . . . . . . .3
SECTION 4 DIMENSIONAL DRAWING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
SECTION 5 PERFORMANCE
A. Performance Curve
Rubber . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
B. Suction Lift Curve . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
SECTION 6 SUGGESTED INSTALLATION, OPERATION & TROUBLESHOOTING . . . . . . . . 6
SECTION 7 DISASSEMBLY / REASSEMBLY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
SECTION 8 EXPLODED VIEW & PARTS LISTING
Wetted . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Center Section Assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20
Inlet Flap Assemblies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .22
SECTION 9 ELASTOMER OPTIONS & CONVERSION KIT . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
O
z
o
I
I
n
e
&
I
s
s
a
l
C
NON
U.S. Clean Air Act
dments of 1990
Amen
D
USE
e
p
l
e
t
i
n
s
e
c
n
a
t
s
b
u
S
g
Page 3
Section 1

CAUTIONS—READ FIRST!

CAUTION: Do not apply compressed air to the
exhaust port — pump will not function.
CAUTION: Do not over-lubricate air supply
— excess lubrication will reduce pump performance.
NOTE: All non lube-free air-operated pumps
must be lubricated. Wilden suggests an arctic 5 weight oil (ISO grade 15). Do no over lubricate pump. Excess lubrication will reduce pump performance.
TEMPERATURE LIMITS:
Neoprene –18°C to 93°C 0°F to 200°F Buna-N –12°C to 82°C 10°F to 180°F EPDM –51°C to 138°C –60°F to 280°F Viton Sanifl ex™ –29°C to 104°C –20°F to 220°F Polytetrafl uoroethylene (PTFE) 4°C to 104°C 40°F to 220°F Polyurethane –12°C to 66°C 10°F to 150°F
®
–40°C to 177°C –40°F to 350°F
NOTE: Not all materials are available for all models. Refer to Section 2 for material options for your pump.
CAUTION: When choosing pump materials, be
sure to check the temperature limits for all wetted components. Example: Viton® has a maximum limit of 177°C (350°F) but polypropylene has a maximum limit of only 79°C (175°F).
CAUTION: Pumps should be thoroughly fl ushed
before installing into process lines. FDA and USDA approved pumps should be cleaned and/ or sanitized before being used.
CAUTION: Always wear safety glasses and
appropriate safety equipment when operating pump. If diaphragm rupture occurs, material being pumped may be forced out air exhaust.
CAUTION: Before any maintenance or repair is
attempted, the compressed air line to the pump should be disconnected and all air pressure allowed to bleed from pump. Disconnect all intake, discharge and air lines. Drain the pump by turning it upside down and allowing any fl uid to fl ow into a suitable container.
CAUTION: Blow out air line for 10 to 20 seconds
before attaching to pump to make sure all pipeline debris is clear. Use an in-line air fi lter. A 5µ (micron) air fi lter is recommended.
NOTE: When installing PTFE diaphragms, it is
important to tighten outer pistons simultaneously (t urnin g in opposite directions) t o ensure t ight fi t. (See torque specifi cations in Section 7.)
NOTE: Cast Iron PTFE-fi tted pumps come
standard from the factory with expanded PTFE gaskets installed in the diaphragm bead of the liquid chamber. PTFE gaskets cannot be re-used.
CAUTION: Maximum temperature limits are
based upon mechanical stress only. Certain chemicals will signifi cantly reduce maximum safe operating temperatures. Consult Chemical Resistance Guide for chemical compatibility and temperature limits.
WARNING: Prevention of static sparking — If
static sparking occurs, fi re or explosion could result. Pump, valves and containers must be grounded to a proper grounding point when handling fl ammable fl uids and whenever discharge of static electricity is a hazard.
CAUTION: Do no exceed 8.6 bar (125 psig) air
supply pressure [3.4 bar (50 psig) on UL Listed pumps].
CAUTION: The process fl uid and cleaning fl uids
must be chemically compatible with all wetted pump components. Consult Chemical Resistance Guide.
WI L-11142- E- 03 1 WILDEN PUMP & ENGINEERING, LLC
CAUTION: When removing the end cap using
compressed air, the air valve end cap may come out with considerable force. Hand protection such as a padded glove or rag should be used to capture the end cap.
NOTE: Before starting disassembly, mark a line
from each liquid chamber to its corresponding air chamber. This line will assist in proper alignment during reassembly.
CAUTION: Tighten all hardware prior to installation.
Page 4
Section 2

WILDEN PUMP DESIGNATION SYSTEM

T1510 ADVANCED™
METAL
76 mm (3") Pump Maximum Flow Rate: 977 LPM (258 GPM)
LEGEND
MATERIAL CODES
MODEL
T1510 = 76 mm (3") ADVANCED™
TOP INLET/BOTTOM DISCHARGE
WETTED PARTS AND OUTER PISTON
AA = ALUMINUM / ALUMINUM WW = DUCTILE IRON / DUCTILE IRON
AIR CHAMBERS
A = ALUMINUM
T1510 / XXXXX / XXX / XX / XXX / XXXX
MODEL
FLAP VALVES
DIAPHRAGMS
AIR VALVE
CENTER BLOCK
AIR CHAMBERS
OUTER PISTONS
WETTED PARTS
CENTER BLOCK
A = ALUMINUM
AIR VALVE
D = BRASS W/OIL BOTTLE
DIAPHRAGMS
BNS = BUNA-N (red dot) NES = NEOPRENE (green dot)
FLAP VALVES
BF = BUNA (red dot) NF = NEOPRENE (green dot)
GASKETS
VALVE SEAT
VALVE SEAT
A = ALUMINUM M = DUCTILE IRON
GASKETS
BN = BUNA-N (red dot) NE = NEOPRENE (green dot)
SPECIALTY CODE
(if applicable)
SPECIALTY CODES
0504 Horizontal Center Ported, DIN Threaded
NOTE: MOST ELASTOMERIC MATERIALS USE COLORED DOT FOR IDENTIFICATION
WILDEN PUMP & ENGINEERING, LLC 2 WIL-11142- E- 03
Page 5
Section 3
HOW IT WORKS—PUMP
The Wilden diaphragm pump is an air-operated, positive displacement, self-priming pump. These drawings show fl ow pattern through the pump upon its initial stroke. It is assumed the pump has no fl uid in it prior to its initial stroke.
OPEN
BA
CLOSED
INLET
CLOSED
OPEN
CLOSED
BA
OPEN
OUTLET
Right Stroke Mid Stroke Left Stroke
FIGURE 1 The air valve dir ects pre ssurized air to the back side of diaphragm A. The compressed air is applied directly to the liquid column separated by elastomeric diaphragms. The diaphragm acts as a separation membrane between the compressed air and liquid, balancing the load and removing mechanical stress from the diaphragm. The compressed air moves the diaphragm away from the center of the pump. The opposite diaphragm is pulled in by the shaft connected to the pressurized diaphragm. Diaphragm B is on its suction stroke; air behind the diaphragm has been forced out to atmosphere through the exhaust port of the pump. The movement of diaphragm B toward the center of the pump creates a vacuum within chamber B. Atmospheric pressure forces fl uid into the inlet manifold forcing the inlet check valve off its seat. Liquid is free to move past the inlet check valve and fi ll the liquid chamber (see shaded area).
FIGURE 2 When the pressurized diaphragm, diaphr agm A, re ache s the limit of i ts dis charge stroke, the air valve redirects pressurized air to the back side of diaphragm B. The pressurized air forces diaphragm B away from the center while pulling diaphragm A to the center. Diaphragm B is now on its discharge stroke. Diaphragm B forces the inlet check valve onto its seat due to the hydraulic forces developed in the liquid chamber and manifold of the pump. These same hydraulic forces lift the discharge check valve off its seat, while the opposite discharge check valve is forced onto its seat, forcing fl uid to fl ow through the pump discharge. The movement of diaphragm A toward the center of the pump creates a vacuum within liquid chamber A. Atmos­pheric pressure forces fl uid into the inlet manifold of the pump. The inlet check valve is forced off its seat allowing the fl uid being pumped to fi ll the liquid chamber.
INLET
OUTLET
OPEN
CLOSED
CLOSED OPEN
INLET
BA
OPEN
OUTLET
FIGURE 3 At completion of the stroke, the air valve again redirects air to the back side of diaphragm A, which starts diaphragm B on its suction stroke. As the pump reaches its original starting point, each diaphragm has gone through one suction and one discharge stroke. This constitutes one complete pumping cycle. The pump may take several cycles to completely prime depending on the conditions of the application.
NOTE: The fl uid inlet of the Brahma Advanced™ pump is located at the top and the fl uid discharge is located at the bottom of the pump.
CLOSED
HOW IT WORKS—AIR DISTRIBUTION SYSTEM
The Turbo-Flo™ air distribution system incorporates one moving part and consists of an air valve body, air valve piston and center block. The unique design of the air valve relies on differential pressure and works in conjunction with the center block bushing and the shaft/diaphragm assembly to direct pressurized air into one of the air chambers while exhausting the other. The air causes the shaft/diaphragm assembly to shift to one side – discharging liquid on that side and pulling liquid in on the other side. When the shaft/diaphragm assembly reaches the end of its stroke, the slots on the shaft align with the slots in the center block bushing “triggering” the air valve piston to shift in the air valve body. The repositioning of the air valve piston routes the pressurized air to the other air chamber.
WI L-11142- E- 03 3 WILDEN PUMP & ENGINEERING, LLC
Page 6
Section 4

DIMENSIONAL DRAWING

T1510 ADVANCED™ METAL
DIMENSIONS
ITEM METRIC (mm) STANDARD (inch)
A 874 34.4 B 107 4.2 C 427 16.8 D 658 25.9 E 754 29.7 F 155 6.1 G 104 4.1 H 427 16.8 J 699 27.5 K 546 21.5
L 358 14.1 M 411 16.2 N 8 0.3
DIN (mm) ANSI (inch) P 200 Dia. 7.5 Dia. R 160 Dia. 6.0 Dia. S 18 Dia. 0.8 Dia.
WILDEN PUMP & ENGINEERING, LLC 4 WIL-11142-E-03
Page 7
Section 5A

PERFORMANCE

T1510 ADVANCED™ METAL
RUBBER-FITTED
Height .................................754 mm (29.7”)
Width ..................................874 mm (34.4”)
Depth ..................................427 mm (16.8”)
Ship Weight ......Aluminum 84 kg (185 lbs.)
Ductile Iron 162 kg (357 lbs.)
Air Inlet ................................... 19 mm (3/4”)
Inlet ............................................ 76 mm (3”)
Outlet ......................................... 76 mm (3”)
Suction Lift ........................ 7.4 m Dry (24.4’)
9.3 m Wet (30.6’) Displacement Per Stroke ..5.56 l (1.47 gal.)¹
Max. Flow Rate ............ 977 lpm (258 gpm)
Max. Size Solids ........................76 mm (3”)
¹ Displacement per stroke was calculated at
4.8 bar (70 psig) air inlet pressure against a 2 bar (30 psig) head pressure.
Example: To pump 394 lpm (104 gpm) against a discharge pressure head of 1.9 bar (28 psig) requires 2.8 bar (40 psig) and 102 Nm3/h (60 scfm) air consumption. (See dot on chart.)
Caution: Do not exceed 8.6 bar (125 psig) air supply pressure.
Section 5B
T1510 ADVANCED™ METAL
RUBBER-FITTED

SUCTION LIFT CURVE

WI L-11142- E- 03 5 WILDEN PUMP & ENGINEERING, LLC
Page 8
Section 6
SUGGESTED INSTALLATION
Wilden pumps are designed to meet the performance requirements of even the most demanding pumping applications. They have been designed and manufactured to the highest standards and are available in a variety of wetted path materials to meet your chemical resistance needs. Refer to the performance section of this manual for an in-depth analysis of the performance characteristics of your pump. Wilden offers the widest variety of elastomer options in the industry to satisfy temperature, chemical compatibility, abrasion resistance and fl ex concerns.
The suction pipe size should be at least the equivalent or larger than the diameter size of the suction inlet on your Wilden pump. The suction hose must be non-collapsible, reinforced type as these pumps are capable of pulling a high vacuum. Discharge piping should also be the equivalent or larger than the diameter of the pump discharge which will help reduce friction losses. It is critical that all fi ttings and connections are airtight or a reduction or loss of pump suction capability will result.
NOTE: The fl uid inlet to the Brahma™ Advanced™ pump is located at the top and the fl uid discharge is located at the bottom of the pump.
INSTALLATION: Months of careful planning, study, and selection efforts can result in unsatisfactory pump performance if installation details are left to chance.
Premature failure and long term dissatisfaction can be avoided if reasonable care is exercised throughout the installation process.
LOCATION: Noise, safety and other logistical factors usually dictate where equipment will be situated on the production fl oor. Multiple installations with confl icting requirements can result in congestion of utility areas, leaving few choices for additional pumps.
Within the framework of these and other existing conditions, every pump should be located in such a way that six key factors are balanced against each other to maximum advantage.
ACCESS: First of all, the location should be accessible. If it’s easy to reach the pump, maintenance personnel will have an easier time carrying out routine inspections and adjustments. Should major repairs become necessary, ease of access can play a key role in speeding the repair process and reducing total downtime.
AIR SUPPLY: Every pump location should have an air line large enough to supply the volume of air necessary to achieve the desired pumping rate. Use air pressure up to a maximum of
8.6 bar (125 psig) depending on pumping requirements.
For best results, the pumps should use a 5µ (micron) air fi lter, needle valve and regulator. The use of an air fi lter before the pump will ensure that the majority of any pipeline contaminants will be eliminated.
SOLENOID OPERATION: When operation is controlled by a solenoid valve in the air line, three-way valves should be used. This valve allows trapped air between the valve and the pump to bleed off which improves pump performance. Pumping volume can be estimated by counting the number of strokes per minute and then multiplying the fi gure by the displacement per stroke.
MUFFLER: Sound levels are reduced below OSHA specifi cations using the standard Wilden muffl er. Other muffl ers can be used to further reduce sound levels, but they usually reduce pump performance.
ELEVATION: Selecting a site that is well within the pump’s dynamic lift capability will assure that loss-of-prime issues will be eliminated. In addition, pump effi ciency can be adversely affected if proper attention is not given to site location.
PIPING: Final determination of the pump site should not be made until the piping challenges of each possible location have been evaluated. The impact of current and future installations should be considered ahead of time to make sure that inadvertent restrictions are not created for any remaining sites.
The best choice possible will be a site involving the shortest and straightest hook-up of suction and discharge piping. Unnecessary elbows, bends, and fi ttings should be avoided. Pipe sizes should be selected to keep friction losses within practical limits. All piping should be supported independently of the pump. In addition, the piping should be aligned to avoid placing stress on the pump fi ttings.
Flexible hose can be installed to aid in absorbing the forces created by the natural reciprocating action of the pump. If the pump is to be bolted down to a solid location, a mounting pad placed between the pump and the foundation will assist in minimizing pump vibration. Flexible connections between the pump and rigid piping will also assist in minimizing pump vibration. If quick-closing valves are installed at any point in the discharge system, or if pulsation within a system becomes a problem, a surge suppressor (SD Equalizer should be installed to protect the pump, piping and gauges from surges and water hammer.
If the pump is to be used in a self-priming application, make sure that all connections are airtight and that the suction lift is within the model’s ability. Note: Materials of construction and elastomer material have an effect on suction lift parameters. Please refer to the performance section for specifi cs.
When pumps are installed in applications involving fl ooded suction or suction head pressures, a gate valve should be installed in the suction line to permit closing of the line for pump service.
Pumps in service with a positive suction head are most effi cient when inlet pressure is limited to 0.5–0.7 bar (7–10 psig). Premature diaphragm failure may occur if positive suction is 0.7 bar (10 psig) and higher.
SUBMERSIBLE APPLICATIONS: Turbo-Flo™ pumps can be used for submersible applications. Pro-Flo V™ pumps can also be used for submersible applications.
NOTE: Accu-Flo™ pumps are not submersible.
ALL WILDEN PUMPS ARE CAPABLE OF PASSING SOLIDS. A STRAINER SHOULD BE USED ON THE PUMP INTAKE TO ENSURE THAT THE PUMP'S RATED SOLIDS CAPACITY IS NOT EXCEEDED.
CAUTION: DO NOT EXCEED 8.6 BAR (125 PSIG) AIR SUPPLY PRESSURE [3.4 BAR (50 PSIG) FOR UL LISTED MODELS].
WILDEN PUMP & ENGINEERING, LLC 6 W IL-1114 2-E- 03
®
)
Page 9
SUGGESTED INSTALLATION
NOTE: The fl uid inlet to the Brahma Advanced™ pump is located at the top and the fl uid discharge is located at the bottom of the pump.
NOTE: In the event of a power failure, the shut off valve should be closed, if the restarting of the pump is not desirable once power is regained.
AIR OPERATED PUMPS: To stop the pump from operating in an emergency situation, simply close the shut off valve (user supplied) installed in the air supply line. A properly functioning valve will stop the air supply to the pump, therefore stopping output. This shut off valve should be located far enough away from the pumping equipment such that it can be reached safely in an emergency situation.
WI L-11142- E- 03 7 WILDEN PUMP & ENGINEERING, LLC
Page 10
SUGGESTED OPERATION & MAINTENANCE
OPERATION: The Turbo-Flo™ pump is is a non lube free pump and requires lubrication. Wilden suggests an arctic 5 weight oil (ISO grade 15). Do not over lubricate the pump. Excessive lubrication will not damage the pump but will reduce pump performance.
Pump discharge rate can be controlled by limiting the volume and/or pressure of the air supply to the pump. A regulator is used to control air pressure while a needle valve is used to control volume. Pump discharge rate can also be controlled by throt tling the pump discharge by partially closing a valve in the discharge line of the pump. This action increases friction loss which reduces fl ow rate. (See Section 5.) This is useful when the need exists to control the pump from a remote location. When the pump discharge pressure equals or exceeds the air supply pressure, the pump will stop; no bypass or pressure relief valve is needed, and pump damage will not occur. The pump has reached a “deadhead” situation and can be restarted by reducing the fl uid discharge pressure or increasing the air inlet pressure.
TROUBLESHOOTING
Tur b o -Flo V ™ p umps run s o lely on c o m pres s e d air and do not generate heat, therefore your process fl uid temperature will not be affected.
MAINTENANCE AND INSPECTIONS: Since each application is unique, maintenance schedules may be different for every pump. Frequency of use, line pressure, viscosity and abrasiveness of process fl uid all affect the parts life of a Wilden pump. Periodic inspections have been found to offer the best means for preventing unscheduled pump downtime. Personnel familiar with the pump’s construction and service should be informed of any abnormalities that are detected during operation.
RECORDS: When service is required, a record should be made of all necessary repairs and replacements. Over a period of time, such records can become a valuable tool for predicting and preventing future maintenance problems and unscheduled downtime. In addition, accurate records make it possible to identify pumps that are poorly suited to their applications.
Pump will not run or runs slowly.
1. Check air inlet screen and air fi lter for debris.
2. Disassemble the pump and check for objects which would obstruct the movement of the internal parts.
3. Check for sticking air valve piston. If air valve piston doesn’t move freely, fl ush air valve with solvent.
4. Check for extreme air leakage (blow by) which would indicate worn air valve or worn main shaft seals.
5. Check for loose outer piston.
6. Check type of lubricant being used. A higher viscosity oil than suggested may cause the piston to stick or run erratically. Wilden suggests the use of an oil with arctic characteristics (ISO 15-5 wt.).
Pump runs but little or no product fl ows.
1. Check for pump cavitation; slow pump speed down to allow thick material to fl ow into liquid chambers.
2. Verify that vacuum required to lift liquid is not greater than the vapor pressure of the material being pumped (cavitation).
3. Check for sticking check valves. If material being pumped is not compatible with pump elastomers,
swelling may occur. Replace check valves with proper elastomers.
Pump air valve freezes.
1. Check for excessive moisture in compressed air. Either install a dryer or hot air generator for c o m p r e s s e d a i r . A l t e r n a t i v e l y , a c o a l e s c i n g fi lter may be used to remove the water from the compressed air in some applications.
Air bubbles in pump discharge.
1. Check for ruptured diaphragm.
2. Check tightness of outer pistons (refer to Section 7).
3. Check tightness of fasteners and integrity of o-rings and seals, especially at intake manifold.
4. Ensure pipe connections are airtight.
Product comes out air exhaust.
1. Check for diaphragm rupture.
2. Check tightness of outer pistons to shaft.
WILDEN PUMP & ENGINEERING, LLC 8 W IL-1114 2-E- 03
Page 11
Section 7
PUMP DISASSEMBLY
TOOLS REQUIRED:
• 7/16" Wrench
• 3/4" Wrench
• 11/16" Wrench
• 1-1/8" Wrench
• 5/16" Hex Key Wrench
• 7/32" Hex Key Wrench
CAUTION: Before any maintenance or repair is attempted, the compressed air line to the pump should be disconnected and all air pressure allowed to bleed from the pump. Disconnect all intake, discharge and air lines. Drain the pump by turning it upside down and allowing any fl uid to fl ow into a suitable container. Be aware of any hazardous effects of contact with your process fl uid.
Step 1
Before starting disassembly, mark a line from each liquid chamber to the corresponding air chamber. This will assist in proper alignment during reassembly.
WI L-11142- E- 03 9 WILDEN PUMP & ENGINEERING, LLC
Step 2
Using a 3/4" wrench, remove the fasteners that connect the inlet elbow to the inlet T- section.
Step 3
Using a 3/4" wrench, remove the fasteners that connect the inlet elbow to the liquid chamber.
Page 12
PUMP DISASSEMBLY
Step 4
Next, remove the inlet elbow from the liquid chamber.
Step 5
Next, remove the fl ap valve assembly from the inlet area of the liquid chamber. Inspect fl ap valve gaskets for nicks, gouges, chemical attack or abrasive wear. Note: replace worn parts with genuine Wilden parts for reliable performance.
Step 6
Using a 7/16" wrench, remove the fl ap valve, the fl ap valve hinge, and fl ap valve retainer from the fl ap valve seat.
Step 7
Using a 3/4" wrench, remove the fasteners that connect the remaining inlet elbow to the inlet T-section.
WILDEN PUMP & ENGINEERING, LLC 10 WI L-11142- E- 03
Step 8
Using a 3/4" wrench, remove the fasteners that connect the remaining inlet elbow to the liquid chamber.
Step 9
Next, remove the remaining inlet elbow from the liquid chamber.
Page 13
PUMP DISASSEMBLY
Step 10
Next, remove the remaining inlet fl ap valve assembly from the inlet elbow. Inspect fl ap valve for nicks, gouges, chemical attack or abrasive wear. Note: replace worn parts with genuine Wilden parts for reliable performance.
Step 11
Using a 3/4" wrench, remove the fasteners that connect the discharge elbow to the discharge T-section and the discharge area of the liquid chamber.
Step 12
Next, remove the discharge elbow from the liquid chamber.
Step 13
Now, remove the discharge fl ap valve assembly.
WI L-11142- E- 03 11 WILDEN PUMP & ENGINEERING, LLC
Step 14
Using a 3/4" wrench, remove the fasteners that connect the remaining discharge elbow to the discharge T­section.
Step 15
Next, using a 3/4" remove the fasteners that connect the discharge elbow to the liquid chamber.
Page 14
PUMP DISASSEMBLY
Step 16
Remove the remaining discharge elbow from the liquid chamber.
Step 17
Now the remaining fl ap valve assembly can be removed.
Step 18
Next, remove the threaded studs from the liquid chamber.
Step 19
Using a 1/4" hex key wrench, remove fasteners that connect the air valve to the center section. Inspect air valve gasket and replace if necessary.
WILDEN PUMP & ENGINEERING, LLC 12 W IL-1114 2-E- 03
Step 20
Prior to attempting removal of the Brahma™ pump stand, position the pump on its side. This will remove the load on each pump stand foot, allowing easy removal. Next, using a 3/4" wrench, remove the fastener that connects pump stand feet to the air chamber.
Step 21
Next, with the pump positioned on the other side, remove the remaining two pump feet.
Page 15
PUMP DISASSEMBLY
Step 22
With the pump still positioned on its side, use a 3/4" wrench to remove the fasteners and liquid chamber.
Step 23
To remove the diaphragm assembly from the pump, remove the lock nut located at the outer piston using a 1-1/8" wrench.
Step 24
With the lock nut removed, the diaphragm assembly can now be removed.
Step 25
Using a 5/16" hex key wrench, remove the fasteners that connect the inner piston to the diaphragm assembly.
WI L-11142- E- 03 13 WILDEN PUMP & ENGINEERING, LLC
Step 26
With the diaphragm assembly removed, the bumper can be removed from the shaft as well.
Step 27
While keeping the rest of the pump secured and using a 3/4" wrench, remove the fasteners that connect the liquid chamber to the air chamber.
Page 16
PUMP DISASSEMBLY
Step 28
With the liquid chamber fasteners removed, the center section can be lifted away from the liquid chamber.
Step 29
Using a 7/32" hex key wrench and a 9/16" wrench, remove the fasteners that connect the air chamber to the center block.
Step 30
Next, list the air chamber away from the center section, exposing the center block gasket. Inspect for nicks, gouges, chemical attack or abrasive wear and replace if necessary.
Step 31
Using a 5/8" wrench, remove the fasteners that connect the center block adapter plate to the air chamber.
WILDEN PUMP & ENGINEERING, LLC 14 WIL-1114 2-E -0 3
Step 32
Next, remove the center block adapter plate o-ring and inspect for nicks, gouges, chemical attack or abrasive wear.
Page 17
AIR VALVE / CENTER SECTION DISASSEMBLY
The air valve assembly consists of both the air valve body and piston and the center block. The unique design of the air valve relies on differential pressure to effect the diaphragm shift. It is reliable and simple to maintain. The bushing in the center block, along with the diaphragm shaft, provides the “trigger” to tell the air valve to shift. The following procedure will ensure that the air valve on your Wilden pump will provide long-lasting trouble-free service.
Air Valve Body And Piston Assembly And Disassembly:
The air valve body and piston can be disconnected from the pump by removing the four socket head cap screws which attach it to the center block. The piston in the air valve is aluminum with a dark gray anodized coating. The piston should move freely and the ports in the piston should line up with the ports on the face of the air valve body (see fi gure A). The piston should also appear to be a dull, dark gray in color. If the piston appears to be a shiny aluminum color, the air valve is probably worn beyond working tolerance and should be replaced.
If the piston does not move freely in the air valve, the entire air valve should be immersed in a cleaning solution.
[NOTE: Do not force the piston by inserting a metal object.] This soaking should remove any accumulation of sludge and grit which is preventing the air valve piston from moving freely. Also, remove and clean the air valve screen. If the air valve piston does not move freely after the above cleaning, the air valve should be disassembled as follows: remove the snap ring from the top end of the air valve cylinder and apply an air jet to the 3/16-inch hole on the opposite end of the air valve face (see fi gure B). CAUTION: The air valve end cap may come out with considerable force. Hand protection such as a padded glove or rag should be used to capture the end cap.
Figure A Figure B
WI L-11142- E- 03 15 WILDEN PUMP & ENGINEERING, LLC
Page 18
AIR VALVE / CENTER SECTION DISASSEMBLY
Small nicks can usually be dressed out and the piston returned to service. Make sure that the guide pin is straight and smooth or the piston will not move freely in the cylinder. Clean out anti-centering pin holes located at each side of the piston. Pin holes are located on each side of the annular groove on the top of the piston and travel to each end. New o-rings should be installed on the end caps. Lubricate the o-rings and install the end caps, assuring that proper alignment of the piston and cylinder ports are maintained (see fi gure A). Reinstall air valve to center block of pump.
Glyd™ Ring Replacement:
When the Glyd™ rings become worn, they will no longer seal and must be replaced.
Center Block Assembly:
The pump’s center block consists of a die cast housing with a cast-in bronze bushing (see fi gure C). The bushing has eleven grooves cut on the inside diameter. There are seven Glyd™ rings that fi t into these grooves (see fi gure G). Since these Glyd™ rings form a part of the shifting function of the pump, it is necessary that they be located in the proper grooves. When bushing wear becomes excessive, a new center block must be used.
Figure C
(Side View)
3/16" DRILL BLEED-OFF
PORT
Grooves in bushing which contain Glyd™ rings
P/N 15-3210-55-225
Figure D
5/32" DRILL BLEED-OFF
PORT
3/16" DRILL BLEED-OFF
PORT
P/N 08-3806-09
Figure G
Center Block (Front View)
WILDEN PUMP & ENGINEERING, LLC 16 WIL-11142- E- 03
Page 19
REASSEMBLY HINTS & TIPS
ASSEMBLY:
Upon performing applicable maintenance to the air distribution system, the pump can now be reassembled. Please refer to the disassembly instructions for photos and parts placement. To reassemble the pump, follow the disassembly instructions in reverse order. The air distribution system needs to be assembled fi rst, then the diaphragms and fi nally the wetted path. Please fi nd the applicable torque specifi cations on this page. The following tips will assist in the assembly process.
• Clean the inside of the center section shaft bushing to ensure no damage is done to new shaft seals.
• Remove the air chamber from the center block assembly prior to removing the center block adapter plate from the air chamber.
• When reassembling the pump, leave wetted path fasteners somewhat loose until all wetted components are installed. This will simplify proper wetted component joint alignment and will ensure proper sealing.
• Stainless steel bolts should be lubed to reduce the possibility of seizing during tightening.
SHAFT SEAL INSTALLATION:
Pre-installation
• Once all of the old seals have been removed, the inside of the bushing should be cleaned to ensure no debris is left that may cause premature damage to the new seals.
T1510 MAXIMUM TORQUE SPECIFICATIONS
INSTALLATION
The following tools can be used to aid in the installation of the new seals:
Needle Nose Pliers
Phillips Screwdriver
Electrical Tape
• Wrap electrical tape around each leg for the needle nose pliers (heat shrink tubing may also be used). This is done to prevent damage to the inside surface of the seal.
• With a new seal in hand, place the two prongs of the needle nose pliers inside the seal ring (see fi gure E).
• Open the pliers as wide as the seal diameter will allow, then with two fi ngers pull down on the top portion of the seal to form a kidney shape (see fi gure F).
• Lightly clamp the pliers together to hold the seal into the kidney shape. Be sure to pull the seal into as tight of a kidney shape as possible. This will allow the seal to travel down the bushing bore easier.
• With the seal clamped in the needle nose pliers, insert the seal into the bushing bore and position the bottom of the seal into the correct groove. Once the bottom of the seal is seated in the groove, release the clamp pressure on the pliers. This will allow the seal to partially snap back to its original shape.
• Slowly insert the shaft with a rotating motion. This wil l allow complete the resizing of the seal.
• Perform these steps for the remaining seals.
Description of Part Torque
Air Valve 9.0 N•m (80 in-lbs)
Center Block Assembly 27.1 N•m (20 ft-lbs)
Center Block Adapter Plate to Air Chamber 40.7 N•m (30 ft-lbs)
Outer Piston 40.7 N•m (30 ft-lbs)
Flap Valve Assembly 1.7 N•m (15 in-lbs)
Liquid Chamber to Air Chamber 40.7 N•m (30 ft-lbs)
Manifold Elbow to Liquid Chamber 40.7 N•m (30 ft-lbs)
Manifold Elbow to T-Section 40.7 N•m (30 ft-lbs)
Figure F
NEEDLE NOSE
PLIERS
Figure E
SHAFT SEAL
SHAFT SEAL
TAPE
WI L-11142- E- 03 17 WILDEN PUMP & ENGINEERING, LLC
TAPE
Page 20
Section 8
EXPLODED VIEW AND PARTS LISTING
T1510 ADVANCED METAL
DRAWING B
DRAWING A
Wetted Path EXPLODED VIEW
DRAWING C
ALL CIRCLED PART IDENTIFIERS ARE INCLUDED IN CONVERSION KIT
WILDEN PUMP & ENGINEERING, LLC 18 WI L-11142- E- 03
(see section 9).
Page 21
EXPLODED VIEW AND PARTS LISTING
T1510 ADVANCED METAL
Item Description Qty
1 Assembly, Air Valve
2 Screen, Air Valve 1 08-2500-07 08-2500-07 08-2500-07 08-2500-07 3 Cap (without Guide), Air Valve Body End 1 15-2330-23 15-2330-23 15-2330-23 15-2330-23 4 Cap (with Guide), Air Valve Body End 1 15-2300-23 15-2300-23 15-2300-23 15-2300-23 5 Ring, Retaining 2 15-2650-03 15-2650-03 15-2650-03 15-2650-03 6 O-ring 2 15-2390-52 15-2390-52 15-2390-52 15-2390-52 7 Gasket, Air Valve 1 15-2600-52 15-2600-52 15-2600-52 15-2600-52 8 Screw, 5/16-18 × 2¼ SHC 4 08-6000-08 08-6000-08 08-6000-08 08-6000-08 9 Center Block 1 15-3100-01-225 15-3100-01-225 15-3100-01-225 15-3100-01-225
10 Shaft Seal (Not Shown) 7 15-3210-55-225 15-3210-55-225 15-3210-55-225 15-3210-55-225
11 Gasket, Center Block 2 15-3528-52 15-3528-52 15-3528-52 15-3528-52 12 Plate, Center Block Adapter 2 08-3880-01 08-3880-01 08-3880-01 08-3880-01
13 O-Ring 2 08-3025-52 08-3025-52 08-3025-52 08-3025-52
14 Chamber, Air 2 15-3665-01 15-3665-01 15-3665-01 15-3665-01
15 Shaft 1 15-3806-09 15-3806-09 15-3806-09 15-3806-09 16 Bumper 2 08-6902-52 08-6902-52 08-6902-52 08-6902-52 17 Piston, Inner 2 15-3705-01 15-3705-02 15-3705-01 15-3705-02
18 Diaphragm, Flap Valve 2 ****
19 Piston, Outer 2 15-4555-01 15-4555-02 15-4555-01 15-4555-02 20 Chamber, Liquid 2 15-4985-01 15-4985-02 15-4985-01 15-4985-02
21 Gasket, Seat 4 **** 22 Gasket, Manifold 4 ****
23 Valve, Flap 4 **** 24 Pad, Flap Valve Hinge 4 ****
25 Retainer, Flap Valve 4 15-1196-08 15-1196-08 15-1196-08 15-1196-08
26 Elbow, Inlet 2 15-5215-01 15-5215-02 15-5215-01 15-5215-02 27 Ring, Manifold Sealing 4 **** 28 T-Section 2 15-5175-01 15-5175-02 15-5176-01 15-5176-02 29 Elbow, Discharge 2 15-5255-01 15-5255-02 15-5255-01 15-5255-02
30 Seat, Flap Valve 4 15-1150-01 15-1150-02 15-1150-01 15-1150-02 31 Left - Hand Foot 2 15-5546-08 15-5546-08 15-5546-08 15-5546-08 32 Right - Hand Foot 2 15-5545-08 15-5545-08 15-5545-08 15-5545-08 33 Nut, 3/8-16 Cone 4 08-6550-08 08-6550-08 08-6550-08 08-6550-08
34 Washer, 7/16 Plain
35 Screw, 7/16-14 × 1.18 HHC 8 08-6195-08 08-6195-08 08-6195-08 08-6195-08 36 Screw, 3/8-16 × 5.50 SFCHC 4 08-6231-08 08-6231-08 08-6231-08 08-6231-08 37 Stud, 1/4-20 × 1.50 Threaded 8 08-6162-08 08-6162-08 08-6162-08 08-6162-08 38 Nut, 1/4-20 Lock Hex 8 08-6477-08 08-6477-08 08-6477-08 08-6477-08 39 Stud, 7/16-14 × 2.38 Threaded 12 15-6161-08 15-6161-08 15-6161-08 15-6161-08 40 Stud, 7/16-14 × 3.19 Threaded 8 15-6162-08 15-6162-08 15-6162-08 15-6162-08
41 Screw, 1/2-13 × 2.38 HHC 40 15-6184-08 15-6184-08 15-6184-08 15-6184-08 42 Nut, 7/16-14 Hex 20 08-6427-08 08-6427-08 08-6427-08 08-6427-08 43 Screw, 7/16-14 × 1.75 HHC 4 08-6195-08 08-6195-08 08-6195-08 08-6195-08 44 Washer, .63 ID × 1.00 OD × .05 Plain 12 15-6741-07 15-6741-07 15-6741-07 15-6741-07 45 Washer, .79 ID × .98 OD × .04 Plain 2 15-6742-07 15-6742-07 15-6742-07 15-6742-07 46 Washer, .81 ID × 1.50 OD × .13 Plain 2 15-6743-08 15-6743-08 15-6743-08 15-6743-08 47 Nut, 3/4-10 Lock Hex 2 15-6461-08 15-6461-08 15-6461-08 15-6461-08 48 Screw, 1/2-13 × 1.38 BHC 12 15-6194-08 15-6194-08 15-6194-08 15-6194-08
49 Bottle, Oil 1 15-2850-01 15-2850-01 15-2850-01 15-2850-01 50 Plug, ¼ NPT 1 08-7000-07 08-7000-07 08-7000-07 08-7000-07 51 Assembly, Capillary Rod 1 15-2900-99 15-2900-99 15-2900-99 15-2900-99 52 Screw, 1/2-13 x 1.00 HHC 8 08-6132-08 08-6132-08 08-6132-08 08-6132-08
53 Washer, 1/2 Plain 72 04-6730-08 04-6730-08 04-6730-08 04-6730-08 54 Nut, 1/2-13 Hex 24 71-6460-08 71-6460-08 71-6460-08 71-6460-08
55 Nipple, 1 NPT Close 1 15-7420-08 15-7420-08 15-7420-08 15-7420-08 56 Check, Ball 1 15-1450-51 15-1450-51 15-1450-51 15-1450-51 57 Body, Exhaust Check Valve 1 15-3550-01 15-3550-01 15-3550-01 15-3550-01 58 Muffler Kit – OPTIONAL² 1 15-3515-99 15-3515-99 15-3515-99 15-3515-99
*Refer to Elastomer Options in Section 9
1
Air Valve Assembly includes items 1 through 6,
and 49 through 51
WI L-11142- E- 03 19 WILDEN PUMP & ENGINEERING, LLC
1
3
32 08-6734-08 08-6734-08 08-6734-08 08-6734-08
Wetted Path PARTS LISTING
T1510/
AAAAD/…P/N
1 15-2080-07 15-2080-07 15-2080-07 15-2080-07
2
Replaces items 55, 56 & 57 if this option is selected
3
Conversion Kit quantity = 8pcs
All boldface items are primary wear parts.
T1510/
WWAAD/…/0504 P/N
T1510/
AAAAD/…P/N
T1510/
WWAAD/…/0504 P/N
Circled items included in T1510 Conversion Kit P/N 15 -9 670- 01 0504 Specialty Code = Horizontal Center Ported, DIN-Flanged
Page 22
EXPLODED VIEW AND PARTS LISTING
T1510 ADVANCED METAL

Center Section Assembly EXPLODED VIEW

DRAWING A
58
ALL CIRCLED PART IDENTIFIERS ARE INCLUDED IN CONVERSION KIT
WILDEN PUMP & ENGINEERING, LLC 20 WIL-11142- E- 03
(see section 9).
Page 23
EXPLODED VIEW AND PARTS LISTING
T1510 ADVANCED METAL
Item Description Item
1 Assembly, Air Valve
2 Screen, Air Valve 1 08-2500-07 08-2500-07 08-2500-07 08-2500-07 3 Cap (without Guide), Air Valve Body End 1 15-2330-23 15-2330-23 15-2330-23 15-2330-23 4 Cap (with Guide), Air Valve Body End 1 15-2300-23 15-2300-23 15-2300-23 15-2300-23 5 Ring, Retaining 2 15-2650-03 15-2650-03 15-2650-03 15-2650-03 6 O-ring 2 15-2390-52 15-2390-52 15-2390-52 15-2390-52 7 Gasket, Air Valve 1 15-2600-52 15-2600-52 15-2600-52 15-2600-52 8 Screw, 5/16-18 × 2¼ SHC 4 08-6000-08 08-6000-08 08-6000-08 08-6000-08 9 Center Block 1 15-3100-01-225 15-3100-01-225 15-3100-01-225 15-3100-01-225
10 Shaft Seal (Not Shown) 7 15-3210-55-225 15-3210-55-225 15-3210-55-225 15-3210-55-225
11 Gasket, Center Block 2 15-3528-52 15-3528-52 15-3528-52 15-3528-52 12 Plate, Center Block Adapter 2 08-3880-01 08-3880-01 08-3880-01 08-3880-01 13 O-Ring 2 08-3025-52 08-3025-52 08-3025-52 08-3025-52 14 Chamber, Air 2 15-3665-01 15-3665-01 15-3665-01 15-3665-01
15 Shaft 1 15-3806-09 15-3806-09 15-3806-09 15-3806-09 16 Bumper 2 08-6902-52 08-6902-52 08-6902-52 08-6902-52 17 Piston, Inner 2 15-3705-01 15-3705-02 15-3705-01 15-3705-02
18 Diaphragm, Flap Valve 2 * * * *
19 Piston, Outer 2 15-4555-01 15-4555-02 15-4555-01 15-4555-02 20 Chamber, Liquid 2 15-4985-01 15-4985-02 15-4985-01 15-4985-02 21 Gasket, Seat 4 * * * * 22 Gasket, Manifold 4 * * * *
23 Valve, Flap 4 * * * * 24 Pad, Flap Valve Hinge 4 * * * *
25 Retainer, Flap Valve 4 15-1196-08 15-1196-08 15-1196-08 15-1196-08 26 Elbow, Inlet 2 15-5215-01 15-5215-02 15-5215-01 15-5215-02 27 Ring, Manifold Sealing 4 * * * * 28 T-Section 2 15-5175-01 15-5175-02 15-5176-01 15-5176-02 29 Elbow, Discharge 2 15-5255-01 15-5255-02 15-5255-01 15-5255-02 30 Seat, Flap Valve 4 15-1150-01 15-1150-02 15-1150-01 15-1150-02
31 Left - Hand Foot 2 15-5546-08 15-5546-08 15-5546-08 15-5546-08 32 Right - Hand Foot 2 15-5545-08 15-5545-08 15-5545-08 15-5545-08
DRAWING A
33 Nut, 3/8-16 Cone 4 08-6550-08 08-6550-08 08-6550-08 08-6550-08 34 Washer, 7/16 Plain 35 Screw, 7/16-14 × 1.18 HHC 8 08-6195-08 08-6195-08 08-6195-08 08-6195-08 36 Screw, 3/8-16 × 5.50 SFCHC 4 08-6231-08 08-6231-08 08-6231-08 08-6231-08
37 Stud, 1/4-20 × 1.50 Threaded 8 08-6162-08 08-6162-08 08-6162-08 08-6162-08 38 Nut, 1/4-20 Lock Hex 8 08-6477-08 08-6477-08 08-6477-08 08-6477-08 39 Stud, 7/16-14 × 2.38 Threaded 12 15-6161-08 15-6161-08 15-6161-08 15-6161-08 40 Stud, 7/16-14 × 3.19 Threaded 8 15-6162-08 15-6162-08 15-6162-08 15-6162-08
41 Screw, 1/2-13 × 2.38 HHC 40 15-6184-08 15-6184-08 15-6184-08 15-6184-08
42 Nut, 7/16-14 Hex 20 08-6427-08 08-6427-08 08-6427-08 08-6427-08 43 Screw, 7/16-14 × 1.75 HHC 4 08-6195-08 08-6195-08 08-6195-08 08-6195-08 44 Washer, .63 ID × 1.00 OD × .05 Plain 12 15-6741-07 15-6741-07 15-6741-07 15-6741-07 45 Washer, .79 ID × .98 OD × .04 Plain 2 15-6742-07 15-6742-07 15-6742-07 15-6742-07 46 Washer, .81 ID × 1.50 OD × .13 Plain 2 15-6743-08 15-6743-08 15-6743-08 15-6743-08 47 Nut, 3/4-10 Lock Hex 2 15-6461-08 15-6461-08 15-6461-08 15-6461-08 48 Screw, 1/2-13 × 1.38 BHC 12 15-6194-08 15-6194-08 15-6194-08 15-6194-08
49 Bottle, Oil 1 15-2850-01 15-2850-01 15-2850-01 15-2850-01 50 Plug, ¼ NPT 1 08-7000-07 08-7000-07 08-7000-07 08-7000-07 51 Assembly, Capillary Rod 1 15-2900-99 15-2900-99 15-2900-99 15-2900-99 52 Screw, 1/2-13 x 1.00 HHC 8 08-6132-08 08-6132-08 08-6132-08 08-6132-08 53 Washer, 1/2 Plain 72 04-6730-08 04-6730-08 04-6730-08 04-6730-08
54 Nut, 1/2-13 Hex 24 71-6460-08 71-6460-08 71-6460-08 71-6460-08
55 Nipple, 1 NPT Close 1 15-7420-08 15-7420-08 15-7420-08 15-7420-08 56 Check, Ball 1 15-1450-51 15-1450-51 15-1450-51 15-1450-51 57 Body, Exhaust Check Valve 1 15-3550-01 15-3550-01 15-3550-01 15-3550-01 58 Muffler Kit – OPTIONAL² 1 15-3515-99 15-3515-99 15-3515-99 15-3515-99
*Refer to Elastomer Options in Section 9
1
Air Valve Assembly includes items 1 through 6,
and 49 through 51
WI L-11142- E- 03 21 WILDEN PUMP & ENGINEERING, LLC
1
3
Center Section Assembly PARTS LISTING
T1510/
AAAAD/…P/N
1 15-2080-07 15-2080-07 15-2080-07 15-2080-07
32 08-6734-08 08-6734-08 08-6734-08 08-6734-08
2
Replaces items 55, 56 & 57 if this option is selected
3
Conversion Kit quantity = 8pcs
All boldface items are primary wear parts.
T1510/
WWAAD/…/0504 P/N
Circled items included in T1510 Conversion Kit P/N 15 -9 670- 01 0504 Specialty Code = Horizontal Center Ported, DIN-Flanged
T1510/
AAAAD/…P/N
WWAAD/…/0504 P/N
T1510/
Page 24
EXPLODED VIEW AND PARTS LISTING
T1510 ADVANCED METAL
Flap Assemblies EXPLODED VIEW
DRAWING B
DRAWING C
WILDEN PUMP & ENGINEERING, LLC 22 WIL-11142- E- 03
Page 25
EXPLODED VIEW AND PARTS LISTING
T1510 ADVANCED METAL
Item Description Qty
1 Assembly, Air Valve
2 Screen, Air Valve 1 08-2500-07 08-2500-07 08-2500-07 08-2500-07 3 Cap (without Guide), Air Valve Body End 1 15-2330-23 15-2330-23 15-2330-23 15-2330-23 4 Cap (with Guide), Air Valve Body End 1 15-2300-23 15-2300-23 15-2300-23 15-2300-23 5 Ring, Retaining 2 15-2650-03 15-2650-03 15-2650-03 15-2650-03 6 O-ring 2 15-2390-52 15-2390-52 15-2390-52 15-2390-52 7 Gasket, Air Valve 1 15-2600-52 15-2600-52 15-2600-52 15-2600-52 8 Screw, 5/16-18 × 2¼ SHC 4 08-6000-08 08-6000-08 08-6000-08 08-6000-08
9 Center Block 1 15-3100-01-225 15-3100-01-225 15-3100-01-225 15-3100-01-225
10 Shaft Seal (Not Shown) 7 15-3210-55-225 15-3210-55-225 15-3210-55-225 15-3210-55-225
11 Gasket, Center Block 2 15-3528-52 15-3528-52 15-3528-52 15-3528-52 12 Plate, Center Block Adapter 2 08-3880-01 08-3880-01 08-3880-01 08-3880-01 13 O-Ring 2 08-3025-52 08-3025-52 08-3025-52 08-3025-52 14 Chamber, Air 2 15-3665-01 15-3665-01 15-3665-01 15-3665-01 15 Shaft 1 15-3806-09 15-3806-09 15-3806-09 15-3806-09 16 Bumper 2 08-6902-52 08-6902-52 08-6902-52 08-6902-52 17 Piston, Inner 2 15-3705-01 15-3705-02 15-3705-01 15-3705-02
18 Diaphragm, Flap Valve 2 * * * *
19 Piston, Outer 2 15-4555-01 15-4555-02 15-4555-01 15-4555-02 20 Chamber, Liquid 2 15-4985-01 15-4985-02 15-4985-01 15-4985-02
21 Gasket, Seat 4 * * * * 22 Gasket, Manifold 4 * * * *
23 Valve, Flap 4 * * * * 24 Pad, Flap Valve Hinge 4 * * * *
25 Retainer, Flap Valve 4 15-1196-08 15-1196-08 15-1196-08 15-1196-08
26 Elbow, Inlet 2 15-5215-01 15-5215-02 15-5215-01 15-5215-02 27 Ring, Manifold Sealing 4 * 15-5176-02 * * 28 T-Section 2 15-5175-01 15-5176-02 15-5175-01 15-5176-02 29 Elbow, Discharge 2 15-5255-01 15-5255-02 15-5255-01 15-5255-02
30 Seat, Flap Valve 4 15-1150-01 15-1150-02 15-1150-01 15-1150-02
31 Left - Hand Foot 2 15-5546-08 15-5546-08 15-5546-08 15-5546-08 32 Right - Hand Foot 2 15-5545-08 15-5545-08 15-5545-08 15-5545-08 33 Nut, 3/8-16 Cone 4 08-6550-08 08-6550-08 08-6550-08 08-6550-08 34 Washer, 7/16 Plain3 32 08-6734-08 08-6734-08 08-6734-08 08-6734-08 35 Screw, 7/16-14 × 1.18 HHC 8 08-6195-08 08-6195-08 08-6195-08 08-6195-08 36 Screw, 3/8-16 × 5.50 SFCHC 4 08-6231-08 08-6231-08 08-6231-08 08-6231-08
37 Stud, 1/4-20 × 1.50 Threaded 8 08-6162-08 08-6162-08 08-6162-08 08-6162-08 38 Nut, 1/4-20 Lock Hex 8 08-6477-08 08-6477-08 08-6477-08 08-6477-08
DRAWING B & DRAWING C
39 Stud, 7/16-14 × 2.38 Threaded 12 15-6161-08 15-6161-08 15-6161-08 15-6161-08 40 Stud, 7/16-14 × 3.19 Threaded 8 15-6162-08 15-6162-08 15-6162-08 15-6162-08
41 Screw, 1/2-13 × 2.38 HHC 40 15-6184-08 15-6184-08 15-6184-08 15-6184-08 42 Nut, 7/16-14 Hex 20 08-6427-08 08-6427-08 08-6427-08 08-6427-08 43 Screw, 7/16-14 × 1.75 HHC 4 08-6194-08 08-6195-08 08-6195-08 08-6195-08 44 Washer, .63 ID × 1.00 OD × .05 Plain 12 15-6741-07 15-6741-07 15-6741-07 15-6741-07 45 Washer, .79 ID × .98 OD × .04 Plain 2 15-6742-07 15-6742-07 15-6742-07 15-6742-07 46 Washer, .81 ID × 1.50 OD × .13 Plain 2 15-6743-08 15-6743-08 15-6743-08 15-6743-08 47 Nut, 3/4-10 Lock Hex 2 15-6461-08 15-6461-08 15-6461-08 15-6461-08 48 Screw, 1/2-13 × 1.38 BHC 12 15-6194-08 15-6194-08 15-6194-08 15-6194-08 49 Bottle, Oil 1 15-2850-01 15-2850-01 15-2850-01 15-2850-01 50 Plug, ¼ NPT 1 08-7000-07 08-7000-07 08-7000-07 08-7000-07 51 Assembly, Capillary Rod 1 15-2900-99 15-2900-99 15-2900-99 15-2900-99 52 Screw, 1/2-13 x 1.00 HHC 8 08-6132-08 08-6132-08 08-6132-08 08-6132-08 53 Washer, 1/2 Plain 72 04-6730-08 04-6730-08 04-6730-08 04-6730-08 54 Nut, 1/2-13 Hex 24 15-6420-08 71-6460-08 71-6460-08 71-6460-08 55 Nipple, 1 NPT Close 1 15-7420-08 15-7420-08 15-7420-08 15-7420-08 56 Check, Ball 1 15-1450-51 15-1450-51 15-1450-51 15-1450-51 57 Body, Exhaust Check Valve 1 15-3550-01 15-3550-01 15-3550-01 15-3550-01 58 Muffler Kit – OPTIONAL² 1 15-3515-99 15-3515-99 15-3515-99 15-3515-99
*Refer to Elastomer Options in Section 9
1
Air Valve Assembly includes items 1 through 6,
and 49 through 51
WI L-11142- E- 03 23 WILDEN PUMP & ENGINEERING, LLC
1
Flap Assemblies PARTS LISTING
T1510/
AAAAD/…P/N
1 15-2080-07 15-2080-07 15-2080-07 15-2080-07
2
Replaces items 55, 56 & 57 if this option is selected
3
Conversion Kit quantity = 8pcs
All boldface items are primary wear parts.
T1510/
WWAAD/…/0504 P/N
T1510/
AAAAD/…P/N
Circled items included in T1510 Conversion Kit P/N 15 -9 670- 01 0504 Specialty Code = Horizontal Center Ported, DIN-Flanged
WWAAD/…/0504 P/N
T1510/
Page 26
Section 9

ELASTOMER OPTIONS & CONVERSION KIT

T1510 ADVANCEDTM METAL
Diaphragm, Flap
MATERIAL
Neoprene 15-1012-51 15-1395-51 15-1401-51 15-1185-51 15-1195-51 15-1305-51 Buna-N 15-1012-52 15-1395-52 15-1401-52 15-1185-52 15-1195-52 15-1305-52
Valve GASKET, SEAT
CONVERSION KIT
DESCRIPTION PART NO.
Kit, T1510 Brahma Conversion* 15-9670-01
*All Circled items included in T1510 Conversion Kit P/N 15-9670-01
GASKET,
MANIFOLD VALVE, FLAP
PAD, FLAP VALVE
HINGE
RING, MANIFOLD
SEALING
WILDEN PUMP & ENGINEERING, LLC 24 W IL-1114 2- E- 03
Page 27
WARRANTY
Each and every product manufactured by Wilden Pump and Engineering, LLC is built to meet the highest standards of quality. Every pump is functionally tested to insure integrity of operation.
Wilden Pump and Engineering, LLC warrants that pumps, accessories and parts manufactured or supplied by it to be free from defects in material and workmanship for a period of five (5) years from date of installation or six (6) years from date of manufacture, whichever comes first. Failure due to normal wear, misapplication, or abuse is, of course, excluded from this warranty.
Since the use of Wilden pumps and parts is beyond our control, we cannot guarantee the suitability of any pump or part for a particular application and Wilden Pump and Engineering, LLC shall not be liable for any consequential damage or expense arising from the use or misuse of its products on any application. Responsibility is limited solely to replacement or repair of defective Wilden pumps and parts.
All decisions as to the cause of failure are the sole determination of Wilden Pump and Engineering, LLC.
Prior approval must be obtained from Wilden for return of any items for warranty consideration and must be accompanied by the appropriate MSDS for the product(s) involved. A Return Goods Tag, obtained from an authorized Wilden distributor, must be included with the items which must be shipped freight prepaid.
The foregoing warranty is exclusive and in lieu of all other warranties expressed or implied (whether written or oral) including all implied warranties of merchantability and fitness for any particular purpose. No distributor or other person is authorized to assume any liability or obligation for Wilden Pump and Engineering, LLC other than expressly provided herein.
PLEASE PRINT OR TYPE AND FAX TO WILDEN
PUMP INFORMATION
Item # Serial #
Company Where Purchased
YOUR INFOR MATION
Company Name
Industry
Name Title
Street Address
City State Postal Code Country
Telephone Fax E-mail Web Address
Number of pumps in facilit y? Number of Wilden pumps?
Types of pumps in facility (check all that apply): Diaphragm Centrifugal Gear Submersible Lobe
Other
Media being pumped?
How did you hear of Wilden Pump?
Other
Trade Journal Trade Show Internet/E-mail Distributor
ONCE COMPLETE, FAX TO (909) 783-3440
NOTE: WARRANTY VOID IF PAGE IS NOT FA XED TO WILDEN
WILDEN PUMP & ENGINEERING, LLC