Dover PSG Wilden P400, PSG Wilden PS800 Engineering, Operation & Maintenance

Page 1
EOM
Engineering
Operation &
Maintenance
P400
Plastic Pump
Where Innovation Flows
wildenpump.com
Page 2
SECTION 1 CAUTIONS—READ FIRST! .............................................1
SECTION 2 WILDEN PUMP DESIGNATION SYSTEM ................................2
SECTION 3 HOW IT WORKS—PUMP & AIR DISTRIBUTION SYSTEM. . . . . . . . . . . . . . . . 3
SECTION 4 DIMENSIONAL DRAWINGS .............................................4
SECTION 5 PERFORMANCE
P400 Plastic Rubber-Fitted .................................................5
P400 Plastic TPE-Fitted ....................................................5
P400 Plastic Reduced-Stroke PTFE-Fitted .....................................6
P400 Plastic Full-Stroke PTFE-Fitted .........................................6
SECTION 6 SUGGESTED INSTALLATION, OPERATION & TROUBLESHOOTING .......8
SECTION 7 DISASSEMBLY / REASSEMBLY ........................................11
Air Valve / Center Section Disassembly ......................................14
Reassembly Hints & Tips ..................................................16
SECTION 8 EXPLODED VIEW & PARTS LISTING
P400 Plastic .............................................................18
SECTION 9 ELASTOMER OPTIONS ................................................20
Page 3
Section 1
CAUTIONS—READ FIRST!
CAUTION: Do not apply compressed air to the
exhaust port — pump will not function.
CAUTION: Do not over-lubricate air supply —
excess lub rication will reduce pump perfor mance. Pump is pre-lubed.
TEMPERATURE LIMITS:
Acetal –29°C to 82°C –20°F to 180°F Buna-N –12°C to 82°C 10°F to 180°F Geolast
®
–40°C to 82°C –40°F to 180°F Neoprene –18°C to 93°C 0°F to 200°F Nordel
®
EPDM –51°C to 138°C –60°F to 280°F Nylon –18°C to 93°C 0°F to 200°F PFA –7°C to 107°C 45°F to 225°F Polypropylene 0°C to 79°C 32°F to 175°F Polyurethane –12°C to 66°C 10°F to 150°F PVDF –12°C to 107°C 10°F to 225°F Saniflex™ –29°C to 104°C –20°F to 220°F
SIPD PTFE with EPDM-backed SIPD PTFE with Neoprene-backed
PTFE
1
4°C to 104°C 40°F to 220°F
4°C to 137°C 40°F to 280°F
4°C to 93°C 40°F to 200°F
FKM –40°C to 177°C –40°F to 350°F Wil-Flex™ –40°C to 107°C –40°F to 225°F
1
4°C to 149°C (40°F to 300°F) - 13 mm (1/2") and 25 mm (1") models only.
NOTE: Not all materials are available for all models. Refer to Section 2 for material options for your pump.
CAUTION: When choosing pump materials, be
sure to check the temperature limits for all wetted components. Example: FKM has a maximum limit of 177°C (350°F) but polypropylene has a maximum limit of only 79°C (175°F).
CAUTION: Maximum temperature limits are
based upon mechanical stress only. Certain chemicals will significantly reduce maximum safe operating temperatures. Consult Chemical Resistance Guide for chemical compatibility and temperature limits.
WARNING : Prevent static sparking — If static
sparking occurs, fire or explosion could result. Pump, valves, and containers must be grounded to a proper grounding point when handling flammable fluids and whenever discharge of static electricity is a hazard.
CAUTION: Do not exceed 8.6 bar (125 psig) air
supply pressure.
CAUTION: The process fluid and cleaning fluids
must be chemically compatible with all wetted pump components. Consult Chemical Resistance Guide.
CAUTION: Pumps should be thoroughly flushed
before installing into process lines. FDA- and USDA-approved pumps should be cleaned and/ or sanitized before being used.
CAUTION: Always wear safety glasses when
operating pump. If diaphragm rupture occurs, material being pumped may be forced out air exhaust.
CAUTION: Before any maintenance or repair is
attempted, the compressed air line to the pump should be disconnected and all air pressure allowed to bleed from pump. Disconnect all intake, discharge and air lines. Drain the pump by turning it upside down and allowing any fluid to flow into a suitable container.
CAUTION: Blow out air line for 10 to 20 seconds
before attaching to pump to make sure all pipeline debris is clear. Use an in-line air filter. A 5μ (micron) air filter is recommended.
NOTE: When installing PFTE diaphragms, it is
important to tighten outer pistons simultaneously (turning in opposite directions) to ensure tight fit. (See torque specifications in Section 7.)
NOTE: PVDF pumps come standard from the
factory with expanded PTFE gaskets installed in the diaphragm bead of the liquid chamber, in the T-section and in the ball and seat area. PTFE gaskets cannot be re-used. Consult for installation instructions during reassembly.
NOTE: Before starting disassembly, mark a line
from each liquid chamber to its corresponding air chamber. This line will assist in proper alignment during reassembly.
CAUTION: Pro-Flo® pumps cannot be used in
submersible applications.
CAUTION : Tighten all hardware prior to installation.
WIL-11241- E-03 1 WILDEN PUMP & ENGINEERING, LLC
Page 4
Section 2
WILDEN PUMP DESIGNATION SYSTEM
P400
Plastic
38 mm (1-1/2") Pump Maximum Flow Rate: 450 lpm (119 gpm)
LEGEND
P400 / XX XXX / XXX / XX / XXX / XXXX
MODEL
MATERIAL CODES
MODEL
P400 = PRO‑FLO
WETTED PARTS & OUTER PISTON
KK = PVDF / PVDF KZ = PVDF / NO OUTER PISTON PP = POLYPROPYLENE /
POLYPROPYLENE
PZ = POLYPROPYLENE / NO
OUTER PISTON
AIR CHAMBERS
P = POLYPROPYLENE
CENTER BLOCK
P = POLYPROPYLENE
AIR VALVE
P = POLYPROPYLENE
®
DIAPHRAGMS
VALVE BALLS
AIR VALVE
CENTER BLOCK
AIR CHAMBERS
WETTED PARTS & OUTER PISTON
DIAPHRAGMS
BNS = BUNA‑N (Red Dot) EPS = EPDM (Blue Dot) FSS = SANIFLEX™
[Hytrel® (Cream)]
FWL = SANITARY WIL‑FLEX™,
IPD
FWS = SANITARY WIL‑FLEX™,
EZ‑INSTALL [Santoprene®
(Two Black Dots)] NES = NEOPRENE (Green Dot) PUS = POLYURETHANE (Clear) TEU = PTFE W/EPDM BACK‑UP (White) TNU = PTFE W/NEOPRENE BACK‑UP (White) TSS = FULL STROKE PTFE W/SANIFLEX™ BACK‑UP TSU = PTFE W/SANIFLEX™
BACK‑UP (White) TWS = FULL STROKE PTFE
W/WIL‑FLEX™ BACK‑UP VTS = FKM (White Dot) WFS = WIL‑FLEX™ [Santoprene®
(Three Black Dots] ZGS = GEOLAST®, EZ‑INSTALL ZPS = POLYURETHANE,
EZ‑INSTALL ZSS = SANIFLEX™, EZ‑INSTALL ZWL = WIL‑FLEX™, INTEGRAL
PISTON ZWS = WIL‑FLEX™, EZ‑INSTALL
O-RINGS
VALVE SE ATS
VALVE BALLS
BN = BUNA‑N (Red Dot) EP = EPDM (Blue Dot) FS = SANIFLEX™
FW = SANITARY WIL‑FLEX™
NE = NEOPRENE (Green Dot) PU = POLYURETHANE (Clear) TF = PTFE (White) VT = FKM (White Dot) WF = WIL‑FLEX™ [Santoprene®
VALVE SEATS
K = PVDF P = POLYPROPYLENE
VALVE SEAT O-RINGS
BN = BUNA‑N TV = PTFE ENCAP. FKM WF = WIL‑FLEX™ (Santoprene®)
SPECIALT Y CODE
(if applicable)
[Hytrel® (Cream)]
[Santoprene® (Two Black Dots)]
(Three Black Dots)]
SPECIALTY CODES
0100 Wil‑Gard II™ 110V 0102 Wil‑Gard II™, sensor wires ONLY 0103 Wil‑Gard II™ 220V 0502 PFA‑coated hardware 0504 DIN flange 0506 DIN flange, PFA coated hardware 0604 DIN flange Wil‑Gard II™ 220V
NOTE: Most elastomeric materials use colored dots for identification.
WILDEN PUMP & ENGINEERING, LLC 2 WIL-11241- E-03
Page 5
Section 3
HOW IT WORKS—PUMP
The Wilden diaphragm pump is an air-operated, positive displacement, self-priming pump. These drawings show flow pattern through the pump upon its initial stroke. It is assumed the pump has no fluid in it prior to its initial stroke.
FIGUR E 1 The air valve dire cts pre ssurized air to the back side of diaphragm A. The compressed air is applied directly to the liquid column separated by elastomeric diaphragms. The diaphragm acts as a separation membrane between the compressed air and liquid; a balanced load removes mechanical stress from the diaphragm. The compressed air moves the diaphragm away from the center of the pump. The opposite diaphragm is pulled in by the shaft connected to the pressurized diaphragm. Diaphragm B is on its suction stroke; air behind the diaphragm has been forced out to atmosphere through the exhaust por t of the pump. The movement of diaphragm B toward the center of the pump creates a vacuum within chamber B. Atmos pheric pressure forces fluid into the inlet manifold forcing the inlet valve ball off its seat. Liquid is free to move past the inlet valve ball and fill the liquid chamber (see shaded area).
HOW IT WORKS—AIR DISTRIBUTION SYSTEM
FIGURE 2 When the pressurized diaphragm, diaphragm A, reaches the limit of its discharge stroke, the air valve redirects pressurized air to the back side of diaphragm B. The pressurized air forces diaphragm B away from the center while pulling diaphragm A to the center. Diaphragm B is now on its discharge stroke. Diaphragm B forc es the inlet valve b all onto its se at due to the hydraulic forces developed in the liquid chamber and manifold of the pump. These same hydraulic forces lift the discharge valve ball off its seat, while the opposite discharge valve ball is forced onto its seat, forcing fluid to flow through the pump discharge. The movement of diaphragm A toward the center of the pump creates a vacuum within liquid chamber A. Atmos­pheric pressure forces fluid into the inlet manifold of the pump. The inlet valve ball is forced off its seat allowing the fluid being pumped to fill the liquid chamber.
The Pro-Flo moving parts: the air valve spool and the pilot spool. The heart of the system is the air valve spool and air valve. This valve design incorporates an unbalanced spool. The smaller end of the spool is pressurized continuously, while the large end is alternately pressurized then exhausted to move the spool. The spool directs pressurized air to one air chamber while exhausting the other. The air causes the main shaft/diaphragm assembly to shif t to one side — discharging liquid on that side and pulling liquid in on the other side. When the shaf t reaches the end of its stroke, the inner piston actuates the pilot spool, which pressurizes and exhausts the large end of the air valve spool. The repositioning of the air valve spool routes the air to the other air chamber.
®
patented air distribution system incorporates two
FIGURE 3 At completion of the stroke, the air valve again redirec ts air to the back side of diaphragm A, which star ts diaphragm B on its exhaust stroke. As the pump reaches its original starting point, each diaphragm has gone through one exhaust and one discharge stroke. This constitutes one complete pumping cycle. The pump may take several cycles to completely prime depending on the conditions of the application.
WIL-11241- E-03 3 WILDEN PUMP & ENGINEERING, LLC
Page 6
Section 4
DIMENSIONAL DRAWINGS
P400 Polypropylene
DIMENSIONS
ITEM METRIC (mm) STANDARD (inch)
A 476 18.8 B 81 3.2 C 348 13.7 D 602 23.7 E 665 26.2 F 677 26.6 G 131 5.2 H 138 5.4 J 300 11.8 K 351 13.8
L 324 12.8 M 268 10.6 N 208 8.2
P 176 6.9
R 12 0.5
S 91 3.6
DIN FLANGE
T 110 DIA. 4.3 DIA.
U 150 DIA. 5.9 DIA.
V 18 DIA. 0.7 DIA.
ANSI FLANGE
T 98 DIA. 3.9 DIA.
U 127 DIA. 5.0 DIA.
V 16 DIA. 0.6 DIA.
LW0324 REV. A
P400 PVDF
DIMENSIONS
ITEM METRIC (mm) STANDARD (inch)
A 471 18.5
B 83 3.2
C 345 13.6
D 596 23.4
E 659 25.9
F 670 26.4
G 130 5.1
H 137 5.4
J 300 11.8
K 348 13.7
L 319 12.6 M 264 10.4 N 205 8.1
P 174 6.9
R 12 0.5
S 91 3.6
DIN FLANGE
T 110 DIA. 4.3 DIA.
U 149 DIA. 5.9 DIA.
V 18 DIA. 0.7 DIA.
ANSI FLANGE
T 98 DIA. 3.9 DIA.
U 126 DIA. 5.0 DIA.
V 16 DIA. 0.6 DIA.
LW0325 REV. A
WILDEN PUMP & ENGINEERING, LLC 4 WIL-112 41- E- 03
Page 7
Section 5
P400 PLASTIC RUBBER-FITTED
PERFORMANCE
Ship Weight .......Polypropylene 19 kg (41 lb)
PVDF 27 kg (59 lb)
Air Inlet ................................... 13 mm (1/2")
Inlet ...................................... 38 mm (1-1/2")
Outlet ................................... 38 mm (1-1/2")
Suction Lift ....................... 5.5 m Dry (18.2')
9.0 m Wet (29.5')
Disp. per Stroke1 .............. 1.25 L (0.330 gal)
Max. Flow Rate ............ 454 lpm (120 gpm)
Max. Size Solids ................... 6.4 mm (1/4")
1
Displacement per stroke was calculated at
4.8 bar (70 psig) air inlet pressure against a 2 bar (30 psig) head pressure.
Example: To pump 227 lpm (60 gpm) against a discharge head pressure of 5.0 bar (73 psig) requires 6.9 bar (100 psig) and 136 Nm3/h (80 scfm) air consumption.
Caution: Do not exceed 8.6 bar (125 psig) air supply pressure.
Flow rates indicated on chart were determined by pumping water.
For optimum life and performance, pumps should be specified so that daily operation parameters will fall in the center of the pump's performance curve.
P400 PLASTIC TPE-FITTED
Ship Weight .......Polypropylene 19 kg (41 lb)
PVDF 27 kg (59 lb)
Air Inlet ................................... 13 mm (1/2")
Inlet .............................. 38 mm (1-1/2")
Outlet ........................... 38 mm (1-1/2")
Suction Lift ....................... 4.8 m Dry (15.9')
9.3 m Wet (30.6')
Disp. per Stroke1 ............ 1.34 L (0.353 gal)
Max. Flow Rate ............ 454 lpm (120 gpm)
Max. Size Solids .................... 6.4 mm (1/4")
1
Displacement per stroke was calculated at
4.8 bar (70 psig) air inlet pressure against a 2 bar (30 psig) head pressure.
Example: To pump 151 lpm (40 gpm) against a discharge head pressure of 4.3 bar (63 psig) requires 5.5 bar (80 psig) and 68 Nm3/h (40 scfm) air consumption.
Caution: Do not exceed 8.6 bar (125 psig) air supply pressure.
Flow rates indicated on chart were determined by pumping water.
For optimum life and performance, pumps should be specified so that daily operation parameters will fall in the center of the pump's performance curve.
WIL-11241- E-03 5 WILDEN PUMP & ENGINEERING, LLC
Page 8
PERFORMANCE
P400 PLASTIC
REDUCED-STROKE PTFE-FITTED
Ship Weight .......Polypropylene 19 kg (41 lb)
PVDF 27 kg (59 lb)
Air Inlet ................................... 13 mm (1/2")
Inlet ...................................... 38 mm (1-1/2")
Outlet ................................... 38 mm (1-1/2")
Suction Lift ....................... 3.3 m Dry (10.8')
9.7 m Wet (31.8') Disp. per Stroke
Max. Flow Rate .............. 318 lpm (84 gpm)
Max. Size Solids .................... 6.4 mm (1/4")
1
Displacement per stroke was calculated at
4.8 bar (70 psig) air inlet pressure against a 2 bar (30 psig) head pressure.
Example: To pump 178 lpm (47 gpm) against a discharge head pressure of 3.4 bar (50 psig) requires 5.5 bar (80 psig) and 136 Nm3/h (80 scfm) air consumption.
Caution: Do not exceed 8.6 bar (125 psig) air supply pressure.
1
............ 0.59 L (0.155 gal)
Flow rates indicated on chart were determined by pumping water.
For optimum life and performance, pumps should be specified so that daily operation parameters will fall in the center of the pump's performance curve.
P400 PLASTIC FULL-STROKE PTFE-FITTED
Ship Weight .... Polypropylene 19 kg (41 lb)
PVDF 27 kg (59 lb)
Air Inlet ................................... 13 mm (1/2”)
Inlet ......................................38 mm (1-1/2”)
Outlet ...................................38 mm (1-1/2”)
Suction Lift ............................5.7 Dry (18.7’)
9.3 m Wet (30.6’) Disp. Per Stroke
Max. Flow Rate ...........424 lpm (111.9 gpm)
Max. Size Solids ....................6.4 mm (1/4”)
1
Displacement per stroke was calculated at
4.8 bar (70 psig) air inlet pressure against a
2.1 bar (30 psig)head pressure.
Example: To pump 337 lpm (89 gpm) against a discharge head of 1.4 bar (20 psig) requires 5.5 bar (80 psig) and 147 Nm³/h (93 scfm) air consumption.
Caution: Do not exceed 8.6 bar (125 psig) air supply pressure.
1
....................1.1 L (.30 gal)
20[34]
40[68]
60[102]
80[136]
100[170]
10 20 30 40 50 60 70 80 90 100 110 120
[38] [76] [114] [151] [189] [227] [265] [303] [341] [379] [416] [454]
Flow rates indicated on chart were determined by pumping water.
For optimum life and performance, pumps should be specified so that daily operation parameters will fall in the center of the pump's performance curve.
WILDEN PUMP & ENGINEERING, LLC 6 WIL-112 41- E- 03
Page 9
SUCTION-LIFT CURVES
P400 PLASTIC SUCTION-LIFT CAPABILITY
Suction-lift curves are calibrated for pumps operating at 305 m (1,000') above sea level. This chart is meant to be a guide only. There are many variables that can affect your pump's operating characteristics. The number of intake and discharge elbows, viscosity of pumping fluid, elevation (atmospheric pressure) and pipe friction loss all affect the amount of suction lift your pump will attain.
WIL-11241- E-03 7 WILDEN PUMP & ENGINEERING, LLC
Page 10
Section 6
SUGGESTED INSTALLATION
Wilden pumps are designed to meet the performance requirements of even the most demanding pumping applications. They have been designed and manufactured to the highest standards and are available in a variety of liquid path materials to meet your chemical resistance needs. Refer to the performance section of this manual for an in-depth analysis of the performance characteristics of your pump. Wilden offers the widest variety of elastomer options in the industry to satisfy temperature, chemical compatibility, abrasion resistance and flex concerns.
The suction-pipe size should be at least the equivalent or larger than the diameter size of the suction inlet on your Wilden pump. The suction hose must be non-collapsible, reinforced type as these pumps are capable of pulling a high vacuum. Discharge piping should also be the equivalent or larger than the diameter of the pump discharge which will help reduce friction losses. It is critical that all fittings and connections are airtight or a reduction or loss of pump suction capability will result.
INSTALLATION: Months of careful planning, study, and selection efforts can result in unsatisfactory pump performance if installation details are left to chance.
Premature failure and long term dissatisfaction can be avoided if reasonable care is exercised throughout the installation process.
LOCATION: Noise, safety, and other logistical factors usually dictate where equipment will be situated on the production floor. Multiple installations with conflicting requirements can result in congestion of utility areas, leaving few choices for additional pumps.
Within the framework of these and other existing conditions, every pump should be located in such a way that several key factors are balanced against each other to maximum advantage.
ACCESS: First of all, the location should be accessible. If it’s easy to reach the pump, maintenance personnel will have an easier time carrying out routine inspections and adjustments. Should major repairs become necessary, ease of access can play a key role in speeding the repair process and reducing total downtime.
AIR SUPPLY: Every pump location should have an air line large enough to supply the volume of air necessary to achieve the desired pumping rate. Use air pressure up to a maximum of 8.6 bar (125 psig) depending on pumping requirements.
For best results, the pumps should use a 5µ (micron) air filter, needle valve and regulator. The use of an air filter before the pump will ensure that the majority of any pipeline contaminants will be eliminated.
SOLENOID OPERATION: When operation is controlled by a solenoid valve in the air line, three-way valves should be used. This valve allows trapped air between the valve and the pump to bleed off which improves pump performance. Pumping volume can be estimated by counting the number of strokes per minute and then multiplying the figure by the displacement per stroke.
MUFFLER: Sound levels are reduced below OSHA specifications using the standard Wilden muffler. Other mufflers can be used to further reduce sound levels, but they usually reduce pump performance.
ELEVATION: Selecting a site that is well within the pump’s dynamic-lift capability will assure that loss-of-prime issues will be eliminated. In addition, pump efficiency can be adversely affected if proper attention is not given to site location.
PIPING: Final determination of the pump site should not be made until the piping challenges of each possible location have been evaluated. The impact of current and future installations should be considered ahead of time to make sure that inadvertent restrictions are not created for any remaining sites.
The best choice possible will be a site involving the shortest and straightest hook-up of suction and discharge piping. Unnecessary elbows, bends, and fittings should be avoided. Pipe sizes should be selected to keep friction losses within practical limits. All piping should be supported independently of the pump. In addition, the piping should be aligned to avoid placing stress on the pump fittings.
Flexible hose can be installed to aid in absorbing the forces created by the natural reciprocating action of the pump. If the pump is to be bolted down to a solid location, a mounting pad placed between the pump and the foundation will assist in minimizing pump vibration. Flexible connections between the pump and rigid piping will also assist in minimizing pump vibration. If quick-closing valves are installed at any point in the discharge system, or if pulsation within a system becomes a problem, a surge suppressor (SD Equalizer should be installed to protect the pump, piping and gauges from surges and water hammer.
If the pump is to be used in a self-priming application, make sure that all connections are airtight and that the suction lift is within the model’s ability. NOTE: Materials of construction and elastomer material have an effect on suction lift parameters. Please refer to the performance section for specifics.
When pumps are installed in applications involving flooded suction or suction head pressures, a gate valve should be installed in the suction line to permit closing of the line for pump service.
Pumps in service with a positive suction head are most efficient when inlet pressure is limited to 0.5–0.7 bar (7–10 psig). Premature diaphragm failure may occur if positive suction is 0.7 bar (10 psig) and higher.
NOTE: Pro-Flo
ALL WILDEN PUMPS ARE CAPABLE OF PASSING SOLIDS. A STRAINER SHOULD BE USED ON THE PUMP INTAKE TO ENSURE THAT THE PUMP'S RATED SOLIDS CAPACITY IS NOT EXCEEDED.
CAUTION: DO NOT EXCEED 8.6 BAR (125 PSIG) AIR SUPPLY PRESSURE.
®
pumps are not submersible.
®
)
WILDEN PUMP & ENGINEERING, LLC 8 WIL-11241- E-03
Page 11
SUGGESTED OPERATION & MAINTENANCE
This illustration is a generic representation of an air-operated double-diaphragm pump.
NOTE: In the event of a power failure, the shut off valve should be closed, if the restarting of the pump is not desirable once power is regained.
AIR-OPERATED PUMPS: To stop the pump from operating in an emergency situation, simply close the shut-off valve (user-supplied) installed in the air supply line. A properly functioning valve will stop the air supply to the pump, therefore stopping output. This shut-of f valve should be located far enough away from the pumping equipment such that it can be reached safely in an emergency situation.
WIL-11241- E-03 9 WILDEN PUMP & ENGINEERING, LLC
Page 12
SUGGESTED OPERATION & MAINTENANCE
OPERATION: The P400 are pre-lubricated, and do not require in-line lubrication. Additional lubrication will not damage the pump, however if the pump is heavily lubricated by an external source, the pump’s internal lubrication may be washed away. If the pump is then moved to a non-lubricated location, it may need to be disassembled and re-lubricated as described in the DISASSEMBLY/REASSEMBLY INSTRUCTIONS.
Pump discharge rate can be controlled by limiting the volume and/or pressure of the air supply to the pump. An air regulator is used to regulate air pressure. A needle valve is used to regulate volume. Pump discharge rate can also be controlled by throttling the pump discharge by partially closing a valve in the discharge line of the pump. This action increases friction loss which reduces flow rate. (See Section 5.) This is useful when the need exists to control the pump from a remote location. When the pump discharge pressure equals or exceeds the air supply pressure, the pump will stop; no bypass or pressure relief valve is needed, and pump damage will not occur. The pump has reached a “deadhead” situation and can be
TROUBLESHOOTING
restarted by reducing the fluid discharge pressure or increasing the air inlet pressure. Wilden P400 pumps run solely on compressed air and do not generate heat, therefore your process fluid temperature will not be affected.
MAINTENANCE AND INSPECTIONS: Since each application is unique, maintenance schedules may be different for every pump. Frequency of use, line pressure, viscosity and abrasiveness of process fluid all affect the parts life of a Wilden pump. Periodic inspections have been found to offer the best means for preventing unscheduled pump downtime. Personnel familiar with the pump’s construction and service should be informed of any abnormalities that are detected during operation.
RECORDS: When service is required, a record should be made of all necessary repairs and replacements. Over a period of time, such records can become a valuable tool for predicting and preventing future maintenance problems and unscheduled downtime. In addition, accurate records make it possible to identify pumps that are poorly suited to their applications.
Pump will not run or runs slowly.
1. Ensure that the air inlet pressure is at least 0.4 bar (5 psig) above startup pressure and that the differential pressure (the difference between air inlet and liquid discharge pressures) is not less than 0.7 bar (10 psig).
2. Check air inlet filter for debris (see SUGGESTED INSTALLATION).
3. Check for extreme air leakage (blow by) that would indicate worn seals /bores in the air valve, pilot spool, main shaft.
4. Disassemble pump and check for obstructions in the air passageways or objects that would obstruct the movement of internal parts.
5. Check for sticking ball check valves. If material being pumped is not compatible with pump elastomers, swelling may occur. Replace ball check valves and seals with proper elastomers. Also, as the check valve balls wear out, they become smaller and can become stuck in the seats. In this case, replace balls and seats.
6. Check for broken inner piston that will cause the air valve spool to be unable to shift.
7. Remove plug from pilot spool exhaust.
Pump runs but little or no product flows.
1. Check for pump cavitation; slow pump speed down to allow thick material to flow into liquid chambers.
2. Verify that vacuum required to lift liquid is not
WILDEN PUMP & ENGINEERING, LLC 10 WIL-11241- E-03
greater than the vapor pressure of the material being pumped (cavitation).
3. Check for sticking ball check valves. If material being pumped is not compatible with pump elastomers, swelling may occur. Replace ball check valves and seats with proper elastomers. Also, as the check valve balls wear out, they become smaller and can become stuck in the seats. In this case, replace balls and seats.
Pump air valve freezes.
1. Check for excessive moisture in compressed air. Either install a dryer or hot air generator for compressed air. Alternatively, a coalescing filter may be used to remove the water from the compressed air in some applications.
Air bubbles in pump discharge.
1. Check for ruptured diaphragm.
2. Check tightness of outer pistons (refer to Section 7).
3. Check tightness of fasteners and integrity of O-rings and seals, especially at intake manifold.
4. Ensure pipe connections are airtight.
Product comes out air exhaust.
1. Check for diaphragm rupture.
2. Check tightness of outer pistons to shaft.
Page 13
Section 7
PUMP DISASSEMBLY
Tools Required:
• 9/16” Wrench
• Adjustable Wrench
• Vise equipped with soft jaws (such as plywood, plastic or other suitable material)
CAUTION: Before any maintenance or repair is attempted, the compressed air line to the pump should be disconnected and all air pressure allowed to bleed from the pump. Disconnect all intake, discharge, and air lines. Drain the pump by turning it upside down and allowing any fluid to flow into a suitable container. Be aware of any hazardous effects of contact with your process fluid.
NOTE: The model photographed for these instructions incorporates PTFE diaphragms, balls, and seats. Models with Rubber diaphragms, balls and seats are the same except where noted.
Step 1
Please note alignment marks on liquid chambers. Use to properly align center section with liquid chamber.
WIL-11241- E- 0 3 11 WILDEN PUMP & ENGINEERING, LLC
Step 2
Using a 9/16" wrench, loosen the discharge manifold from the liquid chambers.
Step 3
Remove the discharge manifold to expose the valve balls, valve seats and valve seat O-rings.
Page 14
PUMP DISASSEMBLY
Step 4
Inspect valve balls, valve seats, and valve seat O-rings for nicks, gouges, chemical attack or abrasive wear.
Step 5
Using a 9/16” wrench, loosen the inlet manifold from the liquid chambers.
Step 6
Remove the inlet manifold, valve balls, valve seats and valve seat O-rings and inspect for nicks, gouges, chemical attack or abrasive wear.
Step 7
Using a 9/16” wrench, remove the liquid chamber fasteners that secure the liquid chamber to the center section.
WILDEN PUMP & ENGINEERING, LLC 12 WI L-1124 1- E-03
Step 8
Remove the liquid chamber to expose the diaphragm and outer piston.
Step 9
Using two adjustable wrenches, or rotating both diaphragms by hand (counterclockwise), remove the diaphragm assembly from the center section assembly.
Page 15
PUMP DISASSEMBLY
Step 10
Due to varying torque values, one of the following two situations may occur:
1) The outer piston, diaphragm and inner piston remain attached to the shaft and the entire assembly can be removed from the center section.
2) The outer piston, diaphragm and inner piston separate from the shaft, which remains connected to the opposite side diaphragm assembly.
Step 11
Remove diaphragm assembly from shaft, secure shaft with soft jaws (a vise fitted with plywood, plastic or other suitable material) to ensure shaft is not nicked, scratched or gouged. Using an adjustable wrench or rotating counterclockwise by hand, remove diaphragm assembly from shaft.
WIL-11241- E- 0 3 13 WILDEN PUMP & ENGINEERING, LLC
Page 16
AIR DISTRIBUTION SYSTEM (ADS) DISASSEMBLY
Tools Required:
• 3/16” Wrench
• O-ring Pick
CAUTION: Before any maintenance or repair is attempted, the compressed air line to the pump should be disconnected and all air pressure allowed to bleed from the pump. Disconnect all intake, discharge, and air lines. Drain the pump by turning it upside down and allowing any fluid to flow into a suitable container. Be aware of hazardous effects of contact with your process fluid.
Step 1
Using a 3/16” hex-head wrench, loosen air valve bolts.
WILDEN PUMP & ENGINEERING, LLC 14 W IL-112 41 - E- 0 3
Step 2
Remove muffler plate and air valve bolts from air valve assembly, exposing muffler gasket for inspection. Replace if necessary.
Step 3
Lift away air valve assembly and remove air valve gasket for inspection. Replace if necessary.
Page 17
Section 7B
AIR DISTRIBUTION SYSTEM (ADS) DISASSEMBLY
Step 4
Remove air valve end cap to expose air valve spool by simply lifting up on end cap once air valve bolts are removed. NOTE: Pro-Flo V™ air valve incorporates an end cap at both ends of the air valve.
Step 5
Remove the air valve spool from the air valve body by threading one air valve bolt into the end of the air valve spool and gently sliding the spool out of the air valve body. Inspect seals for signs of wear and replace entire assembly if necessary. Use caution when handling air valve spool to prevent damaging seals. removed from assembly. Seals are not sold separately.
NOTE:
Seals should not be
Step 6
Remove pilot sleeve from center section. To do so, the air chambers must be removed from the center block which will expose the pilot spool sleeve.
Step 7
Using an O-ring pick, gently remove the O-ring from the opposite side of the “notched end” on one side of the pilot spool. Gently remove the pilot spool from pilot spool sleeve and inspect for nicks, gouges and wear. Replace pilot sleeve or outer sleeve O-rings if necessary. During re-assembly, never insert the pilot spool into the sleeve with the “notched end” first, this end incorporates the urethane O-ring and will be damaged as it slides over the ports cut in the sleeve. NOTE: Seals should not be removed from pilot spool. Seals are not sold separately.
WIL-11241- E- 0 3 15 WILDEN PUMP & ENGINEERING, LLC
Step 8
Inspect center section seals for signs of wear. If necessary, remove seals with O-ring pick and replace.
Page 18
Section 7C
REASSEMBLY HINTS & TIPS
RE ASS E MB LY:
Upon performing applicable maintenance to the air distrib ution system, t he pump can now be re assembled . Please refer to the disassembly instructions for photos and parts placement. To reassemble the pump, follow the disassembly instructions in reverse order. The air distribution system needs to be assembled first, then the diaphragms and finally the wetted path. Please find the applicable torque specifications on this page. The following tips will assist in the assembly process.
• Lubricate air valve bore, center section shaft and pilot spool bore with NLGI grade 2 white EP bearing grease or equivalent.
• Clean the inside of the center section shaft bore to ensure no damage is done to new seals.
• A small amount of NLGI grade 2 white EP bearing grease can be applied to the muffler and air valve gaskets to locate gaskets during assembly.
• Make sure that the exhaust port on the muffler plate is centered between the two exhaust ports on the center section.
• Stainless bolts should be lubed to reduce the possibility of seizing during tightening.
PRO-FLO® MAXIMUM TORQUE SPECIFICATIONS
Description of Part Torque
®
Pro-Flo
Air Valve Bolts 5.1 N•m (45 in-lb)
Air Chamber to Center Block 27.1 N•m (20 ft-lb)
Outer Piston 47.5 N•m (35 ft-lb)
Manifolds to Liquid Chamber 9.6 N•m (85 in-lb)
Liquid Chamber to Air Chamber 9.6 N•m (85 in-lb)
SHAFT SEAL INSTALLATION:
PRE-INSTALLATION
• Once all of the old seals have been removed, the inside of the bushing should be cleaned to ensure no debris is left that may cause premature damage to the new seals.
INSTALLATION
The following tools can be used to aid in the installation of the new seals:
Needle-Nose Pliers Phillips Screwdriver Electrical Tape
• Wrap electrical tape around each leg of the needle-nose pliers (heat shrink tubing may also be used). This is done to prevent damaging the inside surface of the new seal.
• With a new seal in hand, place the two legs of the needle-nose pliers inside the seal ring. (See Figure A.)
• Open the pliers as wide as the seal diameter will allow, then with two fingers pull down on the top portion of the seal to form kidney-shape. (See Figure B.)
• Lightly clamp the pliers together to hold the seal into the kidney shape. Be sure to pull the seal into as tight of a kidney shape as possible, this will allow the seal to travel down the bushing bore easier.
• With the seal clamped in the pliers, insert the seal into the bushing bore and position the bottom of the seal into the correct groove. Once the bottom of the seal is seated in the groove, release the clamp pressure on the pliers. This will allow the seal to partially snap back to its original shape.
• After the pliers are removed, you will notice a slight bump in the seal shape. Before the seal can be properly resized, the bump in the seal should be removed as much as possible. This can be done with either the Phillips screwdriver or your finger. With either the side of the screwdriver or your finger, apply light pressure to the peak of the bump. This pressure will cause the bump to be almost completely eliminated.
• Lubricate the edge of the shaft with NLGI grade 2 white EP bearing grease.
• Slowly insert the center shaft with a rotating motion. This will complete the resizing of the seal.
• Perform these steps for the remaining seal.
Figure A
SHA FT SE AL
TAPE
WILDEN PUMP & ENGINEERING, LLC 16 WI L-1124 1- E-03
Figure B
SHA FT SE AL
NEEDLE-NOSE
PLIERS
TAPE
Page 19
NOTES
Page 20
Section 8
EXPLODED VIEW AND PARTS LISTING
P400 PLASTIC
EXPLODED VIEW
PLASTIC ADS
FULL-STROKE PTFE FULL-STROKE IPD
REDUCED-STROKE PTFE
LW0328 REV. A
ALL CIRCLED PART IDENTIFIERS ARE INCLUDED IN REPAIR KITS (see section 9).
WILDEN PUMP & ENGINEERING, LLC 18 WI L-1124 1- E-03
Page 21
EXPLODED VIEW AND PARTS LISTING
P400 PLASTIC
Item
Description Qty.
P400/PPPPP
P/N
AIR DISTRIBUTION COMPONENTS
1 Air Valve Assembly, Pro-Flo® 2 O-Ring, End Cap (-225, Ø1.859" x Ø.139") 2 04-2390-52-700 04-2390-52-700
3 End Cap 2 04-2330-20-700 04-2330-20-700 4 Screw, SHC, Air Valve (1/4"-20 x 4-1/2") 4 01-6000-03 01-6000-03 5 Screw, SHC, Air Valve (#10-16 x 1-3/4") 2 04-6351-03 04-6351-03 6 Nut, Square (1/4"-20) 4 00-6505-03 00-6505-03 7 Muffler Plate, Pro-Flo
8 Gasket, Muffler Plate, Pro-Flo 9 Gasket, Air Valve, Pro-Flo
10 Center Block Assembly, Pro-Flo 11 Sleeve, Threaded, Center Block 4 04-7710-08 04-7710-08
12 Removable Pilot Sleeve Assembly 1 04-3882-99 04-3882-99 13 Pilot Spool Retaining O-Ring (-009, Ø.204" x Ø.070") 2 04-2650-49-700 04-2650-49-700 14 Shaft Seal 2 08-3210-55-225 08-3210-55-225 15 Gasket, Center Block Pro-Flo
16 Air Chamber, Pro-Flo 17 Washer, Flat (Ø.406" x Ø.875" x .125") 8 04-6741-03 04-6741-03 18 Screw, HHC (3/8"-16 x 1-1/4") 8 04-6190-03 04-6190-03 19 Bushing Reducer 3/4" MNPT to 1/2" FNPT 1 04-6950-20-700 04-6950-20-700 20 Muffler 3/4" MNPT 1 04-3510-99 04-3510-99
1
®
®
®
® 2
®
®
1 04-2000-20-700 04-2000-20-700
1 04-3180-20-700 04-3180-20-700
1 04-3500-52-700 04-3500-52-700 1 04-2600-52-700 04-2600-52-700
1 04-3110-20 04-3110-20
2 04-3526-56 04-3526-56
2 04-3681-20 04-3681-20
WETTED PATH COMPONENTS
21 Chamber, Liquid 2 04-5005-20 04-5005-21 22 Washer, Plain (Ø.406" x Ø.812" x .065") 32 04-6740-03 04-6740-03 23 Screw, HHCS (3/8"-16 x 3-1/2") 16 04-6191-03 04-6191-03 24 Nut, Hex Flange (3/8"-16) 16 04-6435-03 04-6435-03 25 Screw, HHCS, (3/8"-16 x 1-3/4") 16 04-6181-03 04-6181-03 26 Manifold, Discharge (ANSI) 1 04-5030-20 04-5030-21
Manifold, Discharge (DIN) 1 04-5031-20 04-5031-21
27 Manifold, Inlet (ANSI) 1 04-5090-20 04-5090-21
Manifold, Inlet (DIN) 1 04-5091-20 04-5091-21
GASKETS/VALVE BALLS/VALVE SEATS/VALVE O-RINGS
28 Valve Ball 4 29 Valve Seat 4 04-1125-20 04-1125-21 30 Valve Seat O-Ring (-331, Ø2.225" x Ø.210") 4 * 31 Manifold O-Ring (-340, Ø3.350" x Ø.210") 4 *
* *
FULL-STROKE RUBBER/TPE/PTFE/FSIPD COMPONENTS
32 Shaft, Pro-Flo® Rubber Advanced 1 04-3811-03 04-3811-03 33 Shaft Stud (1/2"-20 x 1-7/8") 2 08-6150-08 08-6150-08 34 Piston, Inner, Full-Stroke Rubber/TPE/PTFE/FSIPD 2 04-3700-01-700 04-3700-01-700
35 Diaphragm, Primary 2 *
Diaphragm, Primary, Full-Stroke PTFE 2 04-1040-55 04-1040-55 Diaphragm, IPD Primary 2 *
36 Diaphragm, Backup, Full-Stroke PTFE 2 *
37 Piston, Outer, Full-Stroke Rubber/TPE/PTFE 2 04-4550-20-500 04-4550-21-500
REDUCED-STROKE PTFE COMPONENTS
32 Shaft, Pro-Flo 34 Piston, Inner, Reduced-Stroke PTFE 2 04-3752-01 04-3752-01
35 Diaphragm, Primary, Reduced-Stroke PTFE 2 04-1010-55 04-1010-55 36 Diaphragm, Backup, Reduced-Stroke PTFE 2 *
37 Piston, Outer, Reduced-Stroke PTFE 2 04-4600-20-500 04-4600-21-500
®
1 04-3842-03 04-3842-03
P400/KKPPP
P/N
* *
*
* *
*
LW0329 REV. A
PARTS LISTING
1
Air Valve Assembly includes item
numbers 2 and 3.
2
Center Block Assembly includes
items 10 and 14.
BSP to NPT Air Line Reducer Bushing (P/N 04-6950-23-702) is available upon request.
0502 Specialty Code = PFA-Coated Hardware
0504 Specialty Code = DIN Flange
*Refer to Elastomer Chart (see Section 9).
All boldface items are primary wear parts.
WIL-11241- E-03 19 WILDEN PUMP & ENGINEERING, LLC
Page 22
Section 9
ELASTOMER OPTIONS
P400 Plastic
MATERIAL DIAPHRAGMS (2)
Polyurethane 04-1010-50 N/A N/A 04-1022-50 N/A N/A Neoprene 04-1010-51 N/A N/A N/A N/A N/A Buna-N 04-1010-52 N/A N/A N/A N/A N/A
®
Geolast EPDM 04-1010-54 N/A N/A N/A N/A N/A FKM 04-1010-53 N/A N/A N/A N/A N/A Saniflex™ 04-1010-56 N/A 04-1065-56 04-1022-56 N/A N/A PTFE N/A 04-1040-55 N/A N/A N/A 04-1010-55 PTFE Encap. (FKM) N/A N/A N/A N/A N/A N/A FDA Wil-Flex™ 04-1010-57 N/A 04-1065-57 04-1022-57 04-1031-57 N/A Wil-Flex™ 04-1010-58 N/A N/A 04-1022-58 N/A N/A Polypropylene N/A N/A N/A N/A N/A N/A PVDF N/A N/A N/A N/A N/A N/A
MATERIAL
Polyurethane N/A 04-1080-50 N/A N/A N/A Neoprene 04-1060-51 04-1080-51 N/A N/A N/A Buna-N N/A 04-1080-52 N/A 08-1300-52-500 04-1371-52
®
Geolast EPDM 04-1060-54 04-1080-54 N/A N/A N/A FKM N/A 04-1080-53 N/A N/A N/A Saniflex™ 04-1060-56 04-1080-56 N/A N/A N/A PTFE N/A 04-1080-55 N/A N/A N/A PTFE Encap. (FKM) N/A N/A N/A 08-1300-60-500 04-1371-60 FDA Wil-Flex™ N/A 04-1080-57 N/A N/A N/A Wil-Flex™ N/A 04-1080-58 N/A 08-1300-58-500 04-1371-58 Polypropylene N/A N/A 04-1125-20 N/A N/A PVDF N/A N/A 04-1125-21 N/A N/A
Backup diaphragms used with PTFE diaphragms only.
N/A N/A N/A 04-1022-15 N/A N/A
REDUCED-STROKE
BACKUP
DIAPHR AGMS (2) VALVE BALLS (4) VALVE SE ATS (4)
N/A N/A N/A N/A N/A
FULL-STROKE
DIAPHRAGMS (2)
FULL-STROKE
BACKUP
DIAPHR AGMS (2)
EZ-INSTSALL
DIAPHRAGMS (2)
VALVE SEAT O-RINGS ( 4)
FULL-STROKE IPD DIAPHRAGMS (2)
MANIFOLD
O-RINGS ( 4)
LW0329 REV. A
REDUCED-STROKE
DIAPHRAGMS (2)
WILDEN PUMP & ENGINEERING, LLC 20 WIL-112 41 - E- 0 3
Page 23
WARRANTY
Each and every product manufactured by Wilden Pump and Engineering, LLC is built to meet the highest standards of quality. Every pump is functionally tested to insure integrity of operation.
Wilden Pump and Engineering, LLC warrants that pumps, accessories and parts manufactured or supplied by it to be free from defects in material and workmanship for a period of five (5) years from date of installation or six (6) years from date of manufacture, whichever comes first. Failure due to normal wear, misapplication, or abuse is, of course, excluded from this warranty.
Since the use of Wilden pumps and parts is beyond our control, we cannot guarantee the suitability of any pump or part for a particular application and Wilden Pump and Engineering, LLC shall not be liable for any consequential damage or expense arising from the use or misuse of its products on any application. Responsibility is limited solely to replacement or repair of defective Wilden pumps and parts.
All decisions as to the cause of failure are the sole determination of Wilden Pump and Engineering, LLC.
Prior approval must be obtained from Wilden for return of any items for warranty consideration and must be accompanied by the appropriate MSDS for the product(s) involved. A Return Goods Tag, obtained from an authorized Wilden distributor, must be included with the items which must be shipped freight prepaid.
The foregoing warranty is exclusive and in lieu of all other warranties expressed or implied (whether written or oral) including all implied warranties of merchantability and fitness for any particular purpose. No distributor or other person is authorized to assume any liability or obligation for Wilden Pump and Engineering, LLC other than expressly provided herein.
PLEASE PRINT OR TYPE AND FAX TO WILDEN
PUMP INFORMATION
Item # Serial #
Company Where Purchased
YOUR INFORMATION
Company Name
Industry
Name Title
Street Address
City State Postal Code C ountry
Telephone Fax E-mail Web Address
Number of pumps in facility? Number of Wilden pumps?
Types of pumps in facility (check all that apply): Diaphragm
Media being pumped?
Other
Centrifugal
Gear
Submersible
Lobe
How did you hear of Wilden Pump?
Other
Trade Journal
Trade Show
Internet/ E-mail
Distributor
ONCE COMPLETE, FAX TO (909) 783-3440
OR GO TO PSGDOVER.COM > WILDEN > SUPPORT TO COMPLETE THE WARRANTY REGISTRATION ONLINE
NOTE: WARRANTY VOID IF PAGE IS NOT FAXED TO WILDEN OR SUBMITTED ONLINE VIA THE PSGDOVER.COM WEBSITE
WILDEN PUMP & ENGINEERING, LLC
Page 24
PSG
22069 Van Buren St., Grand Terrace, CA 92313-5607
P: +1 (909) 422-1730
• F: +1 (909) 783-3440
wildenpump.com
Where Innovation Flows
PSG® reserves the right to modify the information and illustrations contained in this document without prior notice. This is a non-contractual document. 11-2018
Authorized PSG Representative:
Copyrigh t ©2018, PS G®, A Dover Compa ny
REPLACES WIL-11241-E-02
WI L-11241 - E - 03