Dover PSG Wilden PS1520, PSG Wilden PS1530, PSG Wilden XPS1520, PSG Wilden XPS1530 Engineering, Operation & Maintenance

Page 1
EOM
Engineering
Operation &
Maintenance
PS1520/PS1530
FIT Metal Pump
Where Innovation Flows
wildenpump.com
Page 2
SECTION 1 CAUTIONS—READ FIRST! ..............................................1
SECTION 2 WILDEN PUMP DESIGNATION SYSTEM .................................2
SECTION 3 HOW IT WORKS—PUMP & AIR DISTRIBUTION SYSTEM ................3
SECTION 4 DIMENSIONAL DRAWINGS .............................................4
SECTION 5 PERFORMANCE
PS1520/PS1530 Metal Rubber-Fitted ..........................................6
PS1520/PS1530 Metal EZ-Install TPE-Fitted ....................................6
PS1520/PS1530 Metal Full-Stroke PTFE-Fitted ..................................7
PS1520/PS1530 Ductile Iron Full-Stroke PTFE-Fitted .............................8
Suction-Lift Curves ........................................................9
SECTION 6 SUGGESTED INSTALLATION, OPERATION & TROUBLESHOOTING .......10
SECTION 7 DISASSEMBLY / REASSEMBLY ........................................13
Air Valve / Center Section Disassembly ......................................16
Reassembly Hints & Tips ..................................................20
SECTION 8 EXPLODED VIEW & PARTS LISTING
PS1520/PS1530 Aluminum .................................................22
PS1520/PS1530 Metal .....................................................24
SECTION 9 ELASTOMER OPTIONS .................................................26
Page 3
Section 1
CAUTIONS—READ FIRST!
CAUTION : Do not apply compressed air to the
exhaust port — pump will not function.
CAUTION: Do not over-lubricate air supply —
excess lub rication will reduce pump pe rformance. Pump is pre-lubed.
TEMPERATURE LIMITS:
Acetal –29°C to 82°C –20°F to 180°F Buna-N –12°C to 82°C 10°F to 180°F Geolast
®
–40°C to 82°C –40°F to 180°F Neoprene –18°C to 93°C 0°F to 200°F Nordel
®
EPDM –51°C to 138°C –60°F to 280°F Nylon –18°C to 93°C 0°F to 200°F PFA –7°C to 107°C 45°F to 225°F Polypropylene 0°C to 79°C 32°F to 175°F Polyurethane –12°C to 66°C 10°F to 150°F PVDF –12°C to 107°C 10°F to 225°F Saniflex™ –29°C to 104°C –20°F to 220°F
SIPD PTFE with EPDM-backed
SIPD PTFE with Neoprene-backed PTFE Viton
1
4°C to 104°C 40°F to 220°F
®
FKM –40°C to 177°C –40°F to 350°F
4°C to 137°C 40°F to 280°F
4°C to 93°C 40°F to 200°F
Wil-Flex™ –40°C to 107°C –40°F to 225°F
1
4°C to 149°C (40°F to 300°F) - 13 mm (1/2") and 25 mm (1") models only.
CAUTION: Do not exceed 82°C (180°F) air inlet
®
temperature for Pro-Flo
SHIFT models.
CAUTION: Pumps should be thoroughly flushed
before installing into process lines. FDA- and USDA-approved pumps should be cleaned and / or sanitized before being used.
CAUTION: Always wear safety glasses when
operating pump. If diaphragm rupture occurs, material being pumped may be forced out air exhaust.
CAUTION: Before any maintenance or repair is
attempted, the compressed air line to the pump should be disconnected and all air pressure allowed to bleed from pump. Disconnect all intake, discharge and air lines. Drain the pump by turning it upside down and allowing any fluid to flow into a suitable container.
CAUTION: Blow out air line for 10 to 20 seconds
before attaching to pump to make sure all pipeline debris is clear. Use an in-line air filter. A 5μ (micron) air filter is recommended.
NOTE:
Not all materials are available for all models.
Refer to Section 2 for material options for your pump.
CAUTION: When choosing pump materials, be
sure to check the temperature limits for all wetted
components. Example: Viton
®
has a maximum limit of 177°C (350°F) but polypropylene has a maximum limit of only 79°C (175°F).
CAUTION: Maximum temperature limits are
based upon mechanical stress only. Certain chemicals will significantly reduce maximum safe operating temperatures. Please consult the Wilden Chemical Resistance Guide.
WARNING : Prevent static sparking. If static
sparking occurs, fire or explosion could result. Pump, valves and containers must be grounded to a proper grounding point when handling flammable fluids and whenever discharge of static electricity is a hazard.
CAUTION: Do not exceed 8.6 bar (125 psig) air
supply pressure.
CAUTION: The process fluid and cleaning fluids
must be chemically compatible with all wetted pump components. Please consult the Wilden Chemical Resistance Guide.
NOTE: When installing PTFE diaphragms, it is
important to tighten outer pistons simultaneously (turning in opposite directions) to ensure tight fit. (See torque specifications in Section 7.)
NOTE: Some PTFE-fitted pumps come standard
from the factory with expanded PTFE gaskets installed in the diaphragm bead of the liquid chamber. PTFE gaskets cannot be re-used.
NOTE: Before starting disassembly, mark a line
from each liquid chamber to its corresponding air chamber. This line will assist in proper alignment during reassembly.
CAUTION: Pro-Flo® pumps cannot be used
in submersible applications. Pro-Flo® SHIFT pumps do have a single-point exhaust option for submersible applications. Do not use standard Pro-Flo® SHIFT models in submersible applications.
CAUTION : Tighten all hardware prior to installation.
WIL-115 2 0 - E - 0 7 1 WILDEN PUMP & ENGINEERING, LLC
Page 4
Section 2
WILDEN PUMP DESIGNATION SYSTEM
PS1520/PS1530 METAL
76 mm (3") Pump Maximum Flow Rate: 1026 lpm (271 gpm)
MATERIAL CODES
MODEL
XPS 1520 = PRO-FLO® SHIFT
XPS 1530 = PRO-FLO® SHIFT
XPS 1520 = PRO-FLO® SHIFT AT EX
XPS 153 0 = PRO-FLO® SHIFT AT EX
WETTED PARTS/OUTER PISTON
AA = ALUMINUM / ALUMINUM AZ = AL UMINUM /NO PISTON SS = STA INL ESS STEEL / STAINLESS STEEL SZ = STAINLESS STEEL /
WW
WZ
= DUCT IL E IRON / NO OU TER
AIR CHAMBERS
A = ALUMINUM S = STAINLESS STEEL
CENTER BLOCK
A = ALUMINUM P = POLYPROPYL ENE S = STAINLESS STEEL
LEGEND
THREADED PORTS
FL ANGED POR TS
THREADED PORTS
FL ANGED POR TS
NO PISTON
= DUCTIL E IRON / DUC TILE
IRON
PISTON
XPS1520 / XXX XX / XXX / XX / XXX / XXXX
MODEL
DIAPHRAGMS
AIR VALVE
CENTER BLOCK
AIR CHAMBERS
WETTED PARTS & OUTER PISTON
AIR VALVE
A = ALUMINUM P = POLYPROPYL ENE R = ANODIZED ALUMINUM S = STAINLESS STEEL
DIAPHRAGMS
BNS = BUNA-N (Red Dot) EPS = EPDM (Blue Dot) FWL = SANITARY WIL-FLEX FWS = SANITARY WIL-FLEXTM, EZ-INSTALL [Santoprene® (Two Orange Dots)] NES = NEOPRENE (Green Dot) TSS = FULL-STROKE PTFE W/SANIFLEX™ BACK-UP TWS = FULL-STROKE PTFE W/WIL-FLEX™ BACK-UP VTS = VITON® (White Dot) WWL
= WIL-FLEX™ IPD [Santoprene®
(Orange Dot)] XBS = CONDUCTIVE BUNA-N (Two Red Dots) ZGS = GEOLAST®, EZ-INSTALL ZPS = POLYURETHANE, EZ-INSTALL ZSS = SANIFLEX™, EZ-INSTALL ZWS = WIL-FLEX™, EZ-INSTALL
TM
IPD
O-RINGS
VALVE SE ATS
VALVE BALLS
VALVE BALLS
BN = BUNA-N (Red Dot) FS = SANIFLEX™ [Hytrel® (Cream)] FW = SANITARY WIL-FLEXTM [Santoprene® (Two Orange Dots)] EP = EPDM (Blue Dot) NE = NEOPRENE (Green Dot) PU = POLYURETHANE (Brown) TF = PTFE (White) VT = VITON® (Silver or White Dot) WF = WIL-FLEX™ [Santoprene®
(Orange Dot)]
VALVE SEATS
BN = BUNA-N (Red Dot) EP = EPDM (Blue Dot) FS = SANIFLEX™ [Hytrel® (Cream)] FW = SANITARY WIL-FLEXTM [Santoprene® (Two Orange Dots)] M = MILD STEEL NE = NEOPRENE (Green Dot) PU = POLYURETHANE (Brown) S = STAINLESS STEEL VT = VITON® (White Dot) WF = WIL-FLEX™ [Santoprene®
(Orange Dot)]
VALVE SEAT O-RINGS
TF = PT FE (W hite)
SPECIALT Y CODE
(if applicable)
SPECIALTY CODES
0014 BSPT 0100 Wil-Gard 110V 0102 Wil-Gard sensor wires ONLY 0103 Wil-Gard 220V 0320 Single-Point Exhaust
NOTE: Most elastomeric materials use colored dots for identification. NOTE: Not all models are available with all material options.
Viton® is a registered trademark of DuPont Dow Elastomers.
WILDEN PUMP & ENGINEERING, LLC 2 WIL-115 2 0 - E - 0 7
0480 Pump Cycle Monitor (sensor & wires) 0483 Pump Cycle Monitor (module, sensor & wires) 0485 Pump Cycle Monitor (module, sensor & wires), DIN flange 0504 DIN flange
Page 5
Section 3
HOW IT WORKS—PUMP
The Wilden diaphragm pump is an air-operated, positive displacement, self-priming pump. These drawings show flow pattern through the pump upon its initial stroke. It is assumed the pump has no fluid in it prior to its initial stroke.
CLOSED
OUTLET
OPEN
B A
INLET
FIGUR E 1 The air valve dire cts pre ssurized air to the back side of diaphragm A. The compressed air is applied directly to the liquid column separated by elastomeric diaphragms. The diaphragm ac ts as a separation membrane bet ween the compressed air and liquid; a balanced load removes mechanical stress from the diaphragm. The compressed air moves the diaphragm away from the center of the pump. The opposite diaphragm is pulled in by the shaft connected to the pressurized diaphragm. Diaphragm B is on its suction stroke; air behind the diaphragm has been forced out to atmosphere through the exhaust port of the pump. The movement of diaphragm B toward the center of the pump creates a vacuum within chamber B. A tmosphe ric pressure forces fluid into the inlet manifold forcing the inlet valve ball off its seat. Liquid is free to move past the inlet valve ball and fill the liquid chamber (see shaded area).
CLOSEDOPEN
OPEN
OUTLET
CLOSED
B A
CLOSED OPEN
FIGURE 2 phragm
, diaphragm A, reaches the limit of its discharge stroke, the air valve redirects pressurized air to the back side of diaphragm B. The pressurized air forces diaphragm B away from the center while pulling diaphragm A to the center. Diaphragm B is now on its discharge stroke. Diaphragm B forces the inlet valve ball onto its seat due to the hydraulic forces developed in the liquid chamber and manifold of the pump. These same hydraulic forces lift the discharge valve ball off its seat, while the opposite discharge valve ball is forced onto its seat, forcing fluid to flow through the pump discharge. The movement of diaphragm A toward the center of the pump creates a vacuum within liquid chamber A. Atmos­pheric pressure forces fluid into the inlet manifold of the pump. The inlet valve ball is forced off its seat allowing the fluid being pumped to fill the liquid chamber.
INLET
When the pressurized dia-
CLOSED OPEN
OUTLET
B A
OPEN
FIGURE 3 At completion of the stroke, the air valve again redirects air to the back side of diaphragm A, which starts diaphragm B on its exhaust stroke. As the pump reaches its original star ting point, each diaphragm has gone through one exhaust and one discharge stroke. This constitutes one complete pumping cycle. The pump may take several cycles to completely prime depending on the conditions of the application.
INLET
CLOSED
HOW IT WORKS—AIR DISTRIBUTION SYSTEM
The heart of the patented Pro-Flo® SHIFT Air Distribution System (ADS) is the air valve assembly. The air valve design incorporates an unbalanced spool with the small end of the spool being pressurized continuously while the large end of the spool is alternately pressurized, then exhausted to move the spool. The air valve spool directs pressurized air to one chamber while exhausting the other. The air forces the main shaft/diaphragm assembly to move to one side – discharging liquid on that side and pulling liquid in on the other side. When the shaft reaches the end of the stroke, the inner piston actuates the pilot spool, which controls the air to the large end of the air valve spool. The repositioning of the air valve spool routes the air to the other air chamber. The air control spool allows air to flow freely into the air chamber for the majority of each pump stroke, but it significantly restricts the flow of air into the air chamber when activated by the inner piston near the end of the each stroke.
WIL-115 2 0 - E - 0 7 3 WILDEN PUMP & ENGINEERING, LLC
Page 6
Section 4
DIMENSIONAL DRAWINGS
PS1520 Aluminum
DIMENSIONS
ITEM METRIC (mm) STANDARD (inch)
A 635 25.0 B 61 2.4 C 426 16.8 D 759 29.9 E 818 32.2
F 84 3.3 G 414 16.3 H 48 1.9 J 211 8.3 K 189 7.4
L 720 28.4
M 358 14.1 N 307 12.1
P 257 10.1 R 282 11.1 S 15 0.6
LW0258 REV. B
PS1520 Stainless Steel
DIMENSIONS
ITEM METRIC (mm) STANDARD (inch)
A 650 25.6 B 71 2.8 C 443 17.5 D 765 30.1 E 815 32.1
F 71 2.8 G 431 17.0 H 48 1.9 J 211 8.3 K 189 7.4
L 184 7.3
M 721 28.4 N 715 28.2
P 356 14.0 R 305 12.0 S 257 10.1 T 279 11.0 U 15 0.6
LW0259 REV. C
WILDEN PUMP & ENGINEERING, LLC 4 WIL-115 2 0 - E - 0 7
Page 7
DIMENSIONAL DRAWINGS
PS1520 Ductile Iron
DIMENSIONS
ITEM METRIC (mm) STANDARD (inch)
A 670 26.5 B 61 2.4 C 437 17.2 D 757 29.8 E 810 31.9
F 71 2.8 G 425 16.7 H 48 1.9 J 211 8.3
K 189 7.4
L 721 28.4
M 360 14.2 N 305 12.0
P 257 10.1 R 279 11.0 S 15 0.6
LW0350 REV. A
PS1530 Metal
DIMENSIONS
ITEM METRIC (mm) STANDARD (inch)
A 673 26.5 B 105 4.1 C 477 18.8 D 796 31.3 E 890 35.1
F 891 35.3 G 90 3.6 H 88 3.5 J 465 18.3 K 48 1.9
L 211 8.3
M 189 7.4 N 184 7.3
P 721 28.4 R 715 28.2 S 356 14.0 T 305 12.0 U 256 10.1 V 279 11.0
W 14 0.6
DIN (mm) ANSI (inch)
X 200 DIA. 7.5 DIA. Y 160 DIA. 6.0 DIA. Z 18 DIA. 0.8 DIA.
LW0260 REV. C
WIL-115 2 0 - E - 0 7 5 WILDEN PUMP & ENGINEERING, LLC
Page 8
DIMENSIONAL DRAWINGS
PS1530 Aluminum
DIMENSIONS
ITEM METRIC (mm) STANDARD (inch)
A 615 24.2 B 127 5.0 C 545 21.5 D 934 36.8 E 1031 40.6
F 165 6.5 G 533 21.0 H 48 1.9 J 211 8.3 K 400 15.8
L 721 28.4
M 363 14.3
N 307 12.1 P 259 10.2 R 282 11.1 S 18 0.7
DIN (mm) ANSI (inch)
T 200 DIA. 7.5 DIA. U 160 DIA. 6.0 DIA. V 18 DIA. 0.8 DIA.
LW0363 REV. A
WILDEN PUMP & ENGINEERING, LLC 6 WIL-115 2 0 - E - 0 7
Page 9
Section 5
PERFORMANCE
PS1520/PS1530 METAL
RUBBER-FITTED
1520 Threaded AL .................. 69 kg (152 lb)
1520 Threaded SS ............... 126 kg (278 lb)
1520 Threaded Iron .............. 114 kg (251 lb)
1530 Flanged AL ..................101 kg (223 lb)
1530 Flanged SS ................. 137 kg (300 lb)
1530 Flanged Iron ............... 124 kg (272 lb)
Air Inlet .................................................. 3/4”
Inlet ............................................ 76 mm (3”)
Outlet ......................................... 76 mm (3”)
Suction Lift ...................7.2 m Dry (23.8’) AL
9.0 m Wet (29.5’) AL
6.0 m Dry (19.7’) SS
8.6 m Wet (28.4’) SS
6.7 m Dry (22.1’) Iron
9.7 m Wet (31.8’) Iron Disp. per Stroke
5.0 L (1.32 gal) SS
5.0 L (1.31 gal) Iron
Max. Flow Rate .......... 1026 lpm (271 gpm)
Max. Size Solids ..................12.7 mm (1/2”)
1
Displacement per stroke was calculated at
4.8 bar (70 psig) air inlet pressure against a
2.1 bar (30 psig) head pressure.
Example: To pump 700 lpm (185 gpm) against a discharge head of 1.4 bar (20 psig) requires 5.5 bar (80 psig) and 161
3
Nm
/h (95 scfm) air consumption.
Caution: Do not exceed 8.6 bar (125 psig) air supply pressure.
1
............ 5.1 L (1.35 gal) AL
Flow rates indicated on chart were determined by pumping water.
For optimum life and performance, pumps should be specified so that daily operation parameters will fall in the center of the pump's performance curve.
PS1520/PS1530 METAL
EZ-INSTALL TPE-FITTED
1520 Threaded AL .................. 69 kg (152 lb)
1520 Threaded SS ............... 126 kg (278 lb)
1520 Threaded Iron .............. 114 kg (251 lb)
1530 Flanged AL ...................101 kg (223 lb)
1530 Flanged SS ................. 137 kg (300 lb)
1530 Flanged Iron ............... 124 kg (272 lb)
Air Inlet .................................................. 3/4”
Inlet ............................................ 76 mm (3”)
Outlet ......................................... 76 mm (3”)
Suction Lift .................. 6.4 m Dry (21.1’) AL
9.0 m Wet (29.5’) AL
5.4 m Dry (17.6’) SS
8.6 m Wet (28.4’) SS
5.2 m Dry (17.0’) Iron
9.7 m Wet (31.8’) Iron Disp. per Stroke
5.4 L (1.43 gal) SS
5.1 L (1.34 gal) Iron
Max. Flow Rate .......... 1026 lpm (271 gpm)
Max. Size Solids ..................12.7 mm (1/2”)
1
Displacement per stroke was calculated at
4.8 bar (70 psig) air inlet pressure against a
2.1 bar (30 psig) head pressure.
Example: To pump 337 lpm (89 gpm) against a discharge head of 2.8 bar (40 psig) requires 4.1 bar (60 psig) and 85
3
Nm
/h (50 scfm) air consumption.
Caution: Do not exceed 8.6 bar (125 psig) air supply pressure.
WIL-115 2 0 - E - 0 7 7 WILDEN PUMP & ENGINEERING, LLC
1
............ 5.1 L (1.35 gal) AL
Flow rates indicated on chart were determined by pumping water.
For optimum life and performance, pumps should be specified so that daily operation parameters will fall in the center of the pump's performance curve.
Page 10
PERFORMANCE
PS1520/PS1530 METAL
FULL-STROKE PTFE-FITTED
1520 Threaded AL .................. 69 kg (152 lb)
1520 Threaded SS ............... 126 kg (278 lb)
1530 Flanged AL ...................101 kg (223 lb)
1530 Flanged SS ................. 137 kg (300 lb)
Air Inlet .................................................. 3/4”
Inlet ............................................ 76 mm (3”)
Outlet ......................................... 76 mm (3”)
Suction Lift ..................6.2 m Dry (20.2’) AL
8.6 m Wet (28.4’) AL
5.9 m Dry (19.3’) SS
8.6 m Wet (28.4’) SS Disp. per Stroke
5.0 L (1.32 gal) SS
Max. Flow Rate ............ 992 lpm (262 gpm)
Max. Size Solids ..................12.7 mm (1/2”)
1
Displacement per stroke was calculated at
4.8 bar (70 psig) air inlet pressure against a
2.1 bar (30 psig) head pressure.
Example: To pump 420 lpm (111 gpm) against a discharge head of 2.8 bar (40 psig) requires 4.8 bar (70 psig) and 110
3
Nm
/h (65 scfm) air consumption.
Caution: Do not exceed 8.6 bar (125 psig) air supply pressure.
1
............ 4.9 L (1.30 gal) AL
Flow rates indicated on chart were determined by pumping water.
For optimum life and performance, pumps should be specified so that daily operation parameters will fall in the center of the pump's performance curve.
PS1520/PS1530 DUCTILE IRON
FULL-STROKE PTFE-FITTED
1520 Threaded Iron .............. 114 kg (251 lb)
1530 Flanged Iron ............... 124 kg (272 lb)
Air Inlet .................................................. 3/4”
Inlet ............................................ 76 mm (3”)
Outlet ......................................... 76 mm (3”)
Suction Lift ..................... 5.94 m Dry (19.5’)
9.66 m Wet (31.7’) Disp. per Stroke
Max. Flow Rate ............ 874 lpm (231 gpm)
Max. Size Solids ..................12.7 mm (1/2”)
1
Displacement per stroke was calculated at
4.8 bar (70 psig) air inlet pressure against a
2.1 bar (30 psig) head pressure.
Example: To pump 360 lpm (95 gpm) against a discharge head of 3.4 bar (50 psig) requires 5.5 bar (80 psig) and 118
3
Nm
/h (75 scfm) air consumption.
Caution: Do not exceed 8.6 bar (125 psig) air supply pressure.
1
.................. 4.8 L (1.26 gal)
Flow rates indicated on chart were determined by pumping water.
For optimum life and performance, pumps should be specified so that daily operation parameters will fall in the center of the pump's performance curve.
WILDEN PUMP & ENGINEERING, LLC 8 WIL-115 2 0 - E - 0 7
Page 11
SUCTION-LIFT CURVES
PS1520 ALUMINUM SUCTION-LIFT CAPABILITY
Suction-lift curves are calibrated for pumps operating at 305 m (1,000') above sea level. This chart is meant to be a guide only. There are many variables that can affect your pump's operating characteristics. The number of intake and discharge elbows, viscosity of pumping fluid, elevation (atmospheric pressure) and pipe friction loss all affect the amount of suction lift your pump will attain.
PS1520/PS1530 STAINLESS STEEL SUCTION-LIFT CAPABILITY
Suction-lift curves are calibrated for pumps operating at 305 m (1,000') above sea level. This chart is meant to be a guide only. There are many variables that can affect your pump's operating characteristics. The number of intake and discharge elbows, viscosity of pumping fluid, elevation (atmospheric pressure) and pipe friction loss all affect the amount of suction lift your pump will attain.
WIL-115 2 0 - E - 0 7 9 WILDEN PUMP & ENGINEERING, LLC
Page 12
SUCTION-LIFT CURVES
PS1520/PS1530 DUCTILE IRON SUCTION-LIFT CAPABILITY
Suction-lift curves are calibrated for pumps operating at 305 m (1,000') above sea level. This chart is meant to be a guide only. There are many variables that can affect your pump's operating characteristics. The number of intake and discharge elbows, viscosity of pumping fluid, elevation (atmospheric pressure) and pipe friction loss all affect the amount of suction lift your pump will attain.
WILDEN PUMP & ENGINEERING, LLC 10
WIL-115 2 0 - E - 0 7
Page 13
SUGGESTED INSTALLATION
Wilden pumps are designed to meet the performance requirements of even the most demanding pumping applications. They have been designed and manufactured to the highest standards and are available in a variety of liquid-path materials to meet your chemical-resistance needs. Refer to the performance section of this manual for an in-depth analysis of the performance characteristics of your pump. Wilden offers the widest variety of elastomer options in the industry to satisfy temperature, chemical­compatibility, abrasion-resistance and flex concerns.
The suction pipe size should be at least the equivalent or larger than the diameter size of the suction inlet on your Wilden pump. The suction hose must be non-collapsible, reinforced type as these pumps are capable of pulling a high vacuum. Discharge piping should also be the equivalent or larger than the diameter of the pump discharge which will help reduce friction losses. It is critical that all fittings and connections are airtight or a reduction or loss of pump suction capability will result.
INSTALLATION: Months of careful planning, study and selection efforts can result in unsatisfactory pump performance if installation details are left to chance.
Premature failure and long-term dissatisfaction can be avoided if reasonable care is exercised throughout the installation process.
LOCATION: Noise, safety and other logistical factors usually dictate where equipment will be situated on the production floor. Multiple installations with conflicting requirements can result in congestion of utility areas, leaving few choices for additional pumps.
Within the framework of these and other existing conditions, every pump should be located in such a way that six key factors are balanced against each other to maximum advantage.
ACCESS: First of all, the location should be accessible. If it’s easy to reach the pump, maintenance personnel will have an easier time carrying out routine inspections and adjustments. Should major repairs become necessary, ease of access can play a key role in speeding the repair process and reducing total downtime.
AIR SUPPLY: Every pump location should have an air line large enough to supply the volume of air necessary to achieve the desired pumping rate. Use air pressure up to a maximum of 8.6 bar (125 psig) depending on pumping requirements.
For best results, the pumps should use a 5µ (micron) air filter, needle valve and regulator. The use of an air filter before the pump will ensure that the majority of any pipeline contaminants will be eliminated.
SOLENOID OPERATION: When operation is controlled by a solenoid valve in the air line, three-way valves should be used. This valve allows trapped air between the valve and the pump to bleed off which improves pump performance. Pumping volume can be estimated by counting the number of strokes per minute and then multiplying the figure by the displacement per stroke.
MUFFLER: Sound levels are reduced below OSHA specifications using the standard Wilden muffler. Other mufflers can be used to further reduce sound levels, but they usually reduce pump performance.
ELEVATION: Selecting a site that is well within the pump’s dynamic-lift capability will assure that loss-of-prime issues will be eliminated. In addition, pump efficiency can be adversely affected if proper attention is not given to site location.
PIPING: Final determination of the pump site should not be made until the piping challenges of each possible location have been evaluated. The impact of current and future installations should be considered ahead of time to make sure that inadvertent restrictions are not created for any remaining sites.
The best choice possible will be a site involving the shortest and straightest hookup of suction and discharge piping. Unnecessary elbows, bends and fittings should be avoided. Pipe sizes should be selected to keep friction losses within practical limits. All piping should be supported independently of the pump. In addition, the piping should be aligned to avoid placing stress on the pump fittings.
Flexible hose can be installed to aid in absorbing the forces created by the natural reciprocating action of the pump. If the pump is to be bolted down to a solid location, a mounting pad placed between the pump and the foundation will assist in minimizing pump vibration. Flexible connections between the pump and rigid piping will also assist in minimizing pump vibration. If quick-closing valves are installed at any point in the discharge system, or if pulsation within a system becomes a problem, a surge suppressor (SD Equalizer
®
) should be installed to protect the pump, piping and gauges from surges and water hammer.
If the pump is to be used in a self-priming application, make sure that all connections are airtight and that the suction lift is within the model’s ability. NOTE: Materials of construction and elastomer material have an effect on suction lift parameters. Please refer to the performance section for specifics.
When pumps are installed in applications involving flooded suction or suction head pressures, a gate valve should be installed in the suction line to permit closing of the line for pump service.
Pumps in service with a positive suction head are most efficient when inlet pressure is limited to 0.5–0.7 bar (7–10 psig). Premature diaphragm failure may occur if positive suction is 0.7 bar (10 psig) and higher.
SUBMERSIBLE APPLICATIONS: Pro-Flo
®
SHIFT pumps can be used for submersible applications when using the Pro­Flo® SHIFT single-point exhaust option.
ALL WILDEN PUMPS ARE CAPABLE OF PASSING SOLIDS. A STRAINER SHOULD BE USED ON THE PUMP INTAKE TO ENSURE THAT THE PUMP'S RATED SOLIDS CAPACITY IS NOT EXCEEDED.
CAUTION: DO NOT EXCEED 8.6 BAR (125 PSIG) AIR SUPPLY PRESSURE.
WIL-115 2 0 - E - 0 7 11 WILDEN PUMP & ENGINEERING, LLC
Page 14
FOOTPAD
DISCHARGE
SUGGESTED INSTALLATION
This illustration is a generic representation of an air-operated double-diaphragm pump.
MUFFLER
FLEXIBLE
CONNECTION
SUCTION
EQUALIZER
SURGE DAMPENER
(OPTIONAL)
GAUGE (OPTIONAL)
SHUT-OFF VALVE
FLEXIBLE CONNECTION
NEEDLE VALVE
COMBINATION
FILTER & REGULATOR
AIR SHUT-OFF VALVE
NOTE: In the event of a power failure, the shut-off valve should be closed, if the restarting of the pump is not desirable once power is regained.
AIR-OPERATED PUMPS: To stop the pump from operating in an emergency situation, simply close the shut-off valve (user-supplied) installed in the air supply line. A properly functioning valve will stop the air supply to the pump, therefore stopping output. This shut-of f valve should be located far enough away from the pumping equipment such that it can be reached safely in an emergency situation.
WILDEN PUMP & ENGINEERING, LLC 12 WIL-115 2 0 - E - 0 7
Page 15
SUGGESTED OPERATION & MAINTENANCE
OPERATION: The Pro-Flo® SHIFT pumps are pre­lubricated and do not require in-line lubrication. Additional lubrication will not damage the pump; however if the pump is heavily lubricated by an external source, the pump’s internal lubrication may be washed away. If the pump is then moved to a non­lubricated location, it may need to be disassembled and re-lubricated as described in the DISASSEMBLY/ REASSEMBLY INSTRUCTIONS.
Pump discharge rate can be controlled by limiting the volume and/or pressure of the air supply to the pump. An air regulator is used to regulate air pressure. A needle valve is used to regulate volume. Pump discharge rate can also be controlled by throttling the pump discharge by partially closing a valve in the discharge line of the pump. This action increases friction loss which reduces flow rate. (See Section
5.) This is useful when the need exists to control the pump from a remote location. When the pump discharge pressure equals or exceeds the air supply pressure, the pump will stop; no bypass or pressure relief valve is needed, and pump damage will not occur. The pump has reached a “deadhead” situation
and can be restarted by reducing the fluid discharge pressure or increasing the air inlet pressure. Wilden Pro-Flo® SHIFT pumps run solely on compressed air and do not generate heat; therefore, your process fluid temperature will not be affected.
MAINTENANCE AND INSPECTIONS: Since each application is unique, maintenance schedules may be different for every pump. Frequency of use, line pressure, viscosity and abrasiveness of process fluid all affect the parts life of a Wilden pump. Periodic inspections have been found to offer the best means for preventing unscheduled pump downtime. Personnel familiar with the pump’s construction and service should be informed of any abnormalities that are detected during operation.
RECORDS: When service is required, a record should be made of all necessary repairs and replacements. Over a period of time, such records can become a valuable tool for predicting and preventing future maintenance problems and unscheduled downtime. In addition, accurate records make it possible to identify pumps that are poorly suited to their applications.
TROUBLESHOOTING
Pump will not run or runs slowly.
1. Ensure that the air inlet pressure is at least 0.4 bar (5 psig) above startup pressure and that the differential pressure (the difference between air inlet and liquid discharge pressures) is not less than 0.7 bar (10 psig).
2. Check air inlet filter for debris (see SUGGESTED INSTALLATION).
3. Check for extreme air leakage (blow by) that would indicate worn seals /bores in the air valve, pilot spool and main shaft.
4. Disassemble pump and check for obstructions in the air passageways or objects that would obstruct the movement of internal parts.
5. Check for sticking ball check valves. If material being pumped is not compatible with pump elastomers, swelling may occur. Replace ball check valves and seals with proper elastomers. Also, as the check valve balls wear out, they become smaller and can become stuck in the seats. In this case, replace balls and seats.
6. Check for broken inner pistons that would cause the air valve spool to be unable to shift.
7. Remove plug from pilot spool exhaust.
Pump runs but little or no product flows.
1. Check for pump cavitation; slow pump speed down to allow thick material to flow into liquid chambers.
2. Verify that vacuum required to lift liquid is not greater than the vapor pressure of the material being pumped (cavitation).
3. Check for sticking ball check valves. If material being pumped is not compatible with pump elastomers, swelling may occur. Replace ball check valves and seats with proper elastomers. Also, as the check valve balls wear out, they become smaller and can become stuck in the seats. In this case, replace balls and seats.
Pump air valve freezes.
1. Check for excessive moisture in compressed air. Either install a dryer or hot air generator for compressed air. Alternatively, a coalescing filter may be used to remove the water from the compressed air in some applications.
Air bubbles in pump discharge.
1. Check for ruptured diaphragm.
2. Check tightness of outer pistons (refer to Section 7).
3. Check tightness of fasteners and integrity of O-rings and seals, especially at intake manifold.
4. Ensure pipe connections are airtight.
Product comes out air exhaust.
1. Check for diaphragm rupture.
2. Check tightness of outer pistons to shaft.
WIL-115 2 0 - E - 0 7 13 WILDEN PUMP & ENGINEERING, LLC
Page 16
Section 7
PUMP DISASSEMBLY
Tools Required:
• 9/16" Socket Wrench
• 15/16" Socket Wrench
• 1-1/8" Socket Wrench
• Vise equipped w / soft jaws (such as plywood, plastic or other suitable material)
CAUTION: Before any maintenance or repair is attempted, the compressed air line to the pump should be disconnected and all air pressure allowed to bleed from the pump. Disconnect all intake, discharge and air lines. Drain the pump by turning it upside down and allowing any fluid to flow into a suitable container. Be aware of any hazardous effects of contact with your process fluid.
NOTE: The model photographed is an aluminum PX820 51 mm (2”) pump. Your specific pump model may vary from the configuration shown; however, pump disassembly procedure will be the same.
Step 1
Before starting disassembly, mark a line from each liquid chamber to its corresponding air chamber. This line will assist in proper alignment during reassembly.
WILDEN PUMP & ENGINEERING, LLC 14 WIL-115 2 0 - E - 0 7
Step 2
Using the appropriate-sized wrench for your pump size, loosen the discharge manifold from the liquid chambers.
Step 3
Lift the discharge manifold to expose discharge valve balls and valve seats. Inspect ball cage area of manifold for excessive wear or damage.
Page 17
PUMP DISASSEMBLY
Step 4
Remove the discharge valve balls and valve seats from the liquid chambers and inspect for nicks, gouges, chemical attack or abrasive wear. Replace worn parts with genuine Wilden parts for reliable performance.
Step 5
Using the appropriate-sized wrench, loosen the inlet manifold from the liquid chambers. NOTE: Inverting the pump will facilitate removal of inlet manifold.
Step 6
Remove the inlet manifold to expose the valve balls and valve seats.
Step 7
Remove the inlet valve balls and valve seats from the inlet manifold and liquid chambers and inspect for nicks, gouges, chemical attack or abrasive wear.
NOTE: Replace worn parts with genuine Wilden parts for reliable performance.
WIL-115 2 0 - E - 0 7 15 WILDEN PUMP & ENGINEERING, LLC
Step 8
Using an appropriately-sized wrench, remove the liquid chamber from the center section.
Step 9
The liquid chamber should be removed to expose the diaphragm and outer piston using an adjustable wrench. Remove the diaphragm assembly from the center section. Repeat for opposite side.
Page 18
PUMP DISASSEMBLY
Step 10
Inspect the diaphragm assembly for wear, damage or chemical attack. Replace any damaged components with genuine Wilden parts for reliable performance.
Step 11
To remove diaphragm assembly from shaft, secure shaft with soft jaws (aluminum, plastic or plywood) to ensure the shaft is not damaged. Using an adjustable wrench, remove the diaphragm assembly from the shaft.
Step 12
Remove outer piston and stud if equipped. Inspect for wear and replace if necessary.
WILDEN PUMP & ENGINEERING, LLC 16 WIL-115 2 0 - E - 0 7
Page 19
AIR VALVE / CENTER SECTION DISASSEMBLY
Tools Required:
• 3/16” Hex-Head Wrench
• 1/4” Hex-Head Wrench
• Snap-Ring Pliers
• O-Ring Pick
CAUTION: Before any maintenance or repair is attempted, the compressed air line to the pump should be disconnected and all air pressure allowed to bleed from the pump. Disconnect all intake, discharge and air lines. Drain the pump by turning it upside down and allowing any fluid to flow into a suitable container. Be aware of hazardous effects of contact with your process fluid.
®
The Wilden Pro-Flo
SHIFT metal pumps utilize a revolutionary Pro-Flo® air distribution system. Proprietary composite seals reduce the co efficient of friction and allow the Pro-Flo® SHIFT to run lube-free. The Pro-Flo® air distribution system is designed to perform in on/off, non-freezing, non-stalling, tough duty applications.
Step 1
Using a pair of snap-ring pliers, remove the snap-ring from pilot sleeve.
Step 2
Using an O-ring pick, remove O-ring from modulator spool.
Step 3
Using the appropriate-sized wrench, loosen and remove the fasteners that attach the air chamber to center section.
WIL-115 2 0 - E - 0 7 17 WILDEN PUMP & ENGINEERING, LLC
Page 20
AIR VALVE / CENTER SECTION DISASSEMBLY
Step 4
Lift away air chamber from center section and remove center block gasket. Replace gasket if necessary.
Step 5
Turn assembly over and remove the pilot spool sleeve from the center section.
Step 6
Using an O-ring pick, gently remove the O-ring from the opposite side of the dimpled end of the pilot spool.
Step 7
Gently remove the pilot spool from the sleeve and inspect for nicks, wear or damage. Replace the pilot spool assembly or sleeve O-rings if necessary. During reassembly, never insert the dimpled end of the pilot spool first, this will damage the single urethane O-ring by passing it over the ports in the pilot sleeve.
NOTE: Seals should not be removed from the assembly. Seals are not sold separately.
WILDEN PUMP & ENGINEERING, LLC 18 WIL-115 2 0 - E - 0 7
Step 8
Remove modulator spool from center section. Check for wear to spool or O-rings and replace if necessary.
Step 9
Using the appropriate-sized wrench, loosen the fasteners and lift away remaining air chamber and center block gasket from center section. Replace gasket if necessary.
Page 21
AIR VALVE / CENTER SECTION DISASSEMBLY
Step 10
Using an O-ring pick, remove the two (2) shaft bushings from center block. Inspect and replace if necessary. Using an O-ring pick, gently remove the two (2) Glyd™ rings from the center block. Inspect and replace if necessary.
Step 11
Using an O-ring pick, remove the two (2) Glyd™ rings from modulator spool bore. Inspect and replace if necessary.
Step 12
Using an appropriate-sized wrench, remove the pilot exhaust muffler. Inspect for damage or contamination and replace if necessary.
Step 13
Using an appropriate-sized hex wrench, loosen and remove the four (4) air valve bolts from center section assembly.
WIL-115 2 0 - E - 0 7 19 WILDEN PUMP & ENGINEERING, LLC
Step 14
Lift away muffler plate and muffler plate gasket from center block. Inspect for wear and replace if necessary. Lift away the air valve assembly and remove air valve gasket. Inspect the gasket and replace if necessary.
Page 22
AIR VALVE / CENTER SECTION DISASSEMBLY
Step 15
Remove air valve end cap to expose air valve spool by lifting up on end cap. Inspect O-ring on end cap using an O-ring pick. Replace O-ring(s) if necessary. NOTE: The Pro-Flo SHIFT air valve incorporates an end cap at both ends of the air valve.
Step 16
Remove the air valve spool from the air valve body by threading one air valve bolt into the end of the air valve spool and gently sliding the spool out of the air valve body. Inspect seals for signs of wear and replace the entire air valve assembly if necessary. Re-insert the spool immediately into air
®
valve body after inspection as the seals expand and cannot be reinserted after a length of time.
NOTE: Seals should not be removed from the assembly. Seals are not sold separately.
SINGLE-POINT EXHAUST PRO-FLO® SHIFT
Standard Single-Point Exhaust
Step 1
Remove pilot exhaust muffler in pilot bleed port located at the front of the center block. Install 1/4" NPT pipe plug (00-7010-08) into bleed
Step 2
Next, install an optional single-point exhaust air valve gasket (04-2639-52). The single-point air valve gasket can be purchased as a spare part or included
®
with the purchase of a new Pro-Flo
SHIFT pump.
port.
WILDEN PUMP & ENGINEERING, LLC 20 WIL-115 2 0 - E - 0 7
Page 23
REASSEMBLY HINTS & TIPS
AS SEM B LY:
Upon performing applicable maintenance to the air distrib ution system, t he pump can now be re assembled . Please refer to the disassembly instructions for photos and parts placement. To reassemble the pump, follow the disassembly instructions in reverse order. The air distribution system needs to be assembled first, then the diaphragms and finally the wetted path. Please find the applicable torque specifications on this page. The following tips will assist in the assembly process.
• Lubricate air valve bore, center section shaft and pilot spool bore with NLGI grade 2 white EP bearing grease or equivalent.
• Clean the inside of the center section shaft bore to ensure no damage is done to new shaft seals.
• A small amount of NLGI grade 2 white EP bearing grease can be applied to the muffler and air valve gaskets to lubricate gaskets during assembly.
• Make sure that the exhaust port on the muffler plate is centered between the two exhaust ports on the center section.
• Stainless steel bolts should be lubed to reduce the possibility of seizing during tightening.
PRO-FLO® SHIFT MAXIMUM TORQUE SPECIFICATIONS
Description of Part Torque
Air Valve (A luminum, Stainless Steel ) 13.6 N•m (120 in-lb)
Air Valve (Polypropylene) 5.1 N•m (45 in-lb)
Air Chamber/Center Block 27.1 N•m (20 ft-lb)
Manifold/Liquid Chamber 149 N•m (110 ft-lb)
Inner Piston Ring 19.0 N•m (14 ft-lb)
Outer Pistons, Rubber & PTF E 136 N•m (100 ft-lb)
Figure A
SHA FT SE AL
SHAFT SEAL INSTALLATION:
PRE-INSTALLATION
• Once all of the old seals have been removed, the inside of the bushing should be cleaned to ensure no debris is left that may cause premature damage to the new seals.
INSTALLATION
The following tools can be used to aid in the installation of the new seals:
Needle-Nose Pliers Phillips Screwdriver Electrical Tape
• Wrap electrical tape around each leg of the needle-nose pliers (heat shrink tubing may also be used). This is done to prevent damaging the inside surface of the new seal.
• With a new seal in hand, place the two legs of the needle-nose pliers inside the seal ring. (See Figure A.)
• Open the pliers as wide as the seal diameter will allow, then with two fingers pull down on the top portion of the seal to form a kidney shape. (See Figure B.)
• Lightly clamp the pliers together to hold the seal into the kidney shape. Be sure to pull the seal into as tight of a kidney shape as possible, this will allow the seal to travel down the bushing bore with greater ease.
• With the seal clamped in the pliers, insert the seal into the bushing bore and position the bottom of the seal into the correct groove. Once the bottom of the seal is seated in the groove, release the clamp pressure on the pliers. This will allow the seal to partially snap back to its original shape.
• After the pliers are removed, you will notice a slight bump in the seal shape. Before the seal can be properly resized, the bump in the seal should be removed as much as possible. This can be done with either the Phillips screwdriver or your finger. With either the side of the screwdriver or your finger, apply light pressure to the peak of the bump. This pressure will cause the bump to be almost completely eliminated.
• Lubricate the edge of the shaft with NLGI grade 2 white EP bearing
• Slowly insert the center shaft with a rotating motion. This will complete the resizing of the seal.
• Perform these steps for the remaining seals.
Figure B
grease.
NEEDLE-NOSE
PLIERS
TAPE
WIL-115 2 0 - E - 0 7 21 WILDEN PUMP & ENGINEERING, LLC
SHA FT SE AL
TAPE
Page 24
Section 8
EXPLODED VIEW & PARTS LISTING
PS1520/PS1530 ALUMINUM
FULL-STROKE IPD
EXPLODED VIEW
FULL-STROKE PTFE-FITTED
THREADED
ALL CIRCLED PART IDENTIFIERS ARE INCLUDED IN REPAIR KITS
METAL ADS
LWOO42 REV. G
WILDEN PUMP & ENGINEERING, LLC 22 WIL-115 2 0 - E - 0 7
Page 25
EXPLODED VIEW & PARTS LISTING
PS1520/PS1530 ALUMINUM
Item
Air Valve Assembly, Pro-Flo SHIFT
1 2 O-Ring, End Cap (-225, Ø1.859" x Ø.139") 2 04-2390-52-700 04-2390-52-700
3 End Cap 2 04-2340-01 04-2340-01 4 Screw, SHC, Air Valve (1/4"-20 x 4-1/2") 6 01-6000-03 01-6000-03 5 Muffler Plate, Pro-Flo SHIFT 1 04-3189-01 04-3189-01
6 Gasket, Muffler Plate, Pro-Flo SHIFT 1 04-3509-52 04-3509-52 7 Gasket, Air Valve, Pro-Flo SHIFT 1 04-2639-52 04-2639-52
8 Center Block Assembly, Pro-Flo SHIFT
9 Pilot Sleeve Assembly 1 15-3884-99 15-3884-99 10 O-Ring, Pilot Spool Retaining (-009, Ø.208" x Ø.070") 2 04-2650-49-700 04-2650-49-700 11 Seal, Shaft 2 15-3210-55-225 15-3210-55-225 12 Bushing, Shaft 2 15-3306-13 15-3306-13 13 Gasket, Center Block Pro-Flo SHIFT 2 04-3529-56 04-3529-56 14 O-Ring, (-210, Ø.734" x Ø.139") 2 04-3209-49 04-3209-49
15 Air Control Spool 1 15-3859-03 15-3859-03
16 O-Ring, Air Control Spool Retaining (-114, Ø.612" x Ø.103") 2 04-3879-50 04-3879-50
17 Air Chamber, Pro-Flo V™ 2 15-3691-01 15-3691-01 18 Screw, HHC (3/8"-16 x 1-1/8") 8 15-6130-08 15-6130-08 19 Washer, Flat (Ø.406" x Ø.812" x .065") 8 15-6740-08-50 15-6740-08-50 20 Retaining Ring 2 04-3890-03 04-3890-03 21 Grounding Screw, (10-32 x 1/2") Self Tapping 1 04-6345-08 04-6345-08 22 Muffler 1-1/2" MNPT 1 04-3518-99R 04-3518-99R 23 Muffler 1/4" MNPT 1 04-3240-07 04-3240-07
Description Qty.
AIR DISTRIBUTION COMPONENTS
1
2
XPS1520/AAAAA/…/
P/N
1 04-2039-01 04-2039-01
1 15-3129-01 15-3129-01
WETTED PATH COMPONENTS
24 Liquid Chamber, Bolted 2 15-4980-01 15-4980-01 25 Discharge Elbow, Bolted 2 N/A 15-5250-01 26 Inlet Elbow, Bolted 2 N/A 15-5210-01 27 T-Section, Bolted (ANSI) 2 N/A 15-5180-01
T-Section, Bolted (DIN) 2 N/A 15-5185-01
28 Manifold, Discharge (NPT) 1 15-5035-01 N/A
Manifold, Discharge (BSPT) 1 15-5036-01 N/A
29 Manifold, Inlet (NPT) 1 15-5095-01 N/A
Manifold, Inlet (BSPT) 1 15-5096-01 N/A
30 Screw, HHC (5/8"-11 x 2") 40 15-6180-08 N/A
Screw, HHC (5/8"-11 x 2") 56 N/A 15-6180-08
31 Washer, Flat (Ø.656" x Ø1.312" x .095") 40 15-6732-08 N/A
Washer, Flat (Ø.656" x Ø1.312" x .095") 56 N/A 15-6732-08
GASKETS/VALVE BALLS/VALVE SEATS/VALVE O-RINGS
32 T-Section Gasket 4 N/A * 33 Manifold Gasket, PTFE-Fitted (not shown) 4 15-1405-55 15-1405-55 34 Ball, Valve 4 * * 35 Seat, Valve 4 * * 36
O-Ring, Valve Seat PTFE-Fitted (-250, Ø4.984" x Ø.139") (Not Shown)
4 15-1205-55 15-1205-55
FULL-STROKE RUBBER/TPE/PTFE COMPONENTS
37 Shaft 1 15-3805-09 15-3805-09
Shaft, IPD 1 15-3814-09 15-3814-09
38 Piston, Inner 2 15-3700-01 15-3700-01
Piston, IPD Inner 2 08-3700-01 08-3700-01 39 Washer, Inner Piston Backup 2 15-6850-08 15-6850-08 40 Inner Piston Screw, HHC (3/8"-16 x 1-1/8") 12 15-6130-08 15-6130-08 41 Inner Piston Washer (Ø.406" x Ø.812" x .065") 12 15-6740-08-50 15-6740-08-50
42 Diaphragm, Primary 2 * *
Diaphragm, IPD Primary 2 * * 43 Diaphragm, Backup 2 * *
44 Piston, Outer 2 15-4550-01 15-4550-01
* See elastomer chart - Section 9
1
Air Valve Assembly includes items 2 and 3.
2
Metal Center Block Assembly includes items 11, 12, 14, 15 and 16.
All boldface items are primary wear parts.
XPS1530/AAAAA/…/
P/N
PARTS LISTING
LW0049 Rev. R
WIL-115 2 0 - E - 0 7 23 WILDEN PUMP & ENGINEERING, LLC
Page 26
EXPLODED VIEW & PARTS LISTING
PS1520/PS1530 METAL
EXPLODED VIEW
FULL-STROKE PTFE
FULL-STROKE IPD
METAL ADS PLASTIC ADS
ALL CIRCLED PART IDENTIFIERS ARE INCLUDED IN REPAIR KITS
FLANGED
LWOO41 REV. H
WILDEN PUMP & ENGINEERING, LLC 24 W I L-115 2 0 - E - 0 7
Page 27
EXPLODED VIEW & PARTS LISTING
PS1520/PS1530 METAL
Item
Description Qty.
SSAAA/…/
P/N
XPS1520/1530/
1 Air Valve Assembly, Pro-Flo SHIFT 2 O-Ring, End Cap (-225, Ø1.859" x Ø.139") 2 04-2390-52-700 04-2390-52-700 04-2390-52-700 04-2390-52-700 04-2390-52-700
3 End Cap 2 04-2340-01 04-2340-03 04-2330-20-700 04-2340-01 04-2330-20-700 4 Screw, SHC, Air Valve (1/4"-20 x 4-1/2") 6 01-6000-03 01-6000-03 01-6000-03 01-6000-03 01-6000-03 5 Nut, Square (1/4"-20) 6 N/A N/A 00-6505-03 N/A 00-6505-03 6 Muffler Plate, Pro-Flo SHIFT 1 04-3189-01 04-3189-03 04-3189-20 04-3189-01 04-3189-20
7 Gasket, Muffler Plate, Pro-Flo SHIFT 1 04-3509-52 04-3509-52 04-3509-52 04-3509-52 04-3509-52 8 Gasket, Air Valve, Pro-Flo SHIFT 1 04-2639-52 04-2639-52 04-2639-52 04-2639-52 04-2639-52
9 Center Block Assembly, Pro-Flo SHIFT
10 Sleeve, Threaded, Center Block 4 N/A N/A 04-7710-08 N/A 04-7710-08
11 Pilot Sleeve Assembly 1 15-3884-99 15-3884-99 15-3884-99 15-3884-99 15-3884-99 12 O-Ring, Pilot Spool Retaining (-009, Ø.208" x Ø.070") 2 04-2650-49-700 04-2650-49-700 04-2650-49-700 04-2650-49-700 04-2650-49-700 13 Seal, Shaft 2 15-3210-55-225 15-3210-55-225 15-3210-55-225 15-3210-55-225 15-3210-55-225 14 Bushing, Shaft 2 15-3306-13 15-3306-13 15-3306-13 15-3306-13 15-3306-13 15 Gasket, Center Block Pro-Flo SHIFT 2 04-3529-56 04-3529-56 04-3529-56 04-3529-56 04-3529-56 16 O-Ring, (-210, Ø.734" x Ø.139") 2 04-3209-49 04-3209-49 04-3209-49 04-3209-49 04-3209-49
17 Air Control Spool 1 15-3859-03 15-3859-03 15-3859-03 15-3859-03 15-3859-03
O-Ring, Air Control Spool Retaining (-114, Ø.612" x Ø.103")
18
19 Air Chamber, Pro-Flo V™ 2 15-3691-01 15-3690-03 15-3690-03 15-3691-01 15-3691-01 20 Screw, HHC (3/8"-16 x 1-1/8") 8 15-6130-08 N/A N/A 15-6130-08 15-6130-08
Screw, HHC (3/8"-16 x 1") 8 N/A 08-6130-03 08-6130-03 N/A N/A 21 Washer, Flat (Ø.406" x Ø.812" x .065") 8 15-6740-08-50 04-6740-03 04-6740-03 15-6740-08-50 15-6740-08-50 22 Retaining Ring 2 04-3890-03 04-3890-03 04-3890-03 04-3890-03 04-3890-03 23 Grounding Screw, (10-32 x 1/2") Self-Tapping 1 04-6345-08 04-6345-08 N/A 04-6345-08 N/A 24 Bushing, Reducer 1-1/2" MNPT to 1" FNPT 1 N/A N/A 04-6959-17 N/A 04-6959-17 25 Muffler 1" MNPT 1 N/A N/A 15-3514-99 N/A 15-3514-99 26 Muffler 1-1/2" MNPT 1 04-3518-99R 04-3513-99 N/A 04-3518-99R N/A 27 Muffler 1/4" MNPT 1 04-3240-07 04-3240-07 04-3240-07 04-3240-07 04-3240-07
1
2, 3
AIR DISTRIBUTION COMPONENTS
1 04-2039-01 04-2039-03 04-2039-20 04-2039-01 04-2039-20
1 15-3129-01 15-3129-03 15-3129-20 15-3129-01 15-3129-20
2 04-3879-50 04-3879-50 04-3879-50 04-3879-50 04-3879-50
XPS1520/1530/
SSSSS/…/
P/N
PS1520/1530/
SSSPP/…/
P/N
PARTS LISTING
XPS1520/1530/
WWAAA/…/
P/N
PS1520/1530/ WWAPP/…/
/P/N
WETTED PATH COMPONENTS
28 Liquid Chamber, Bolted 2 15-5006-03 15-5006-03 15-5006-03 15-5006-02 15-5006-02 29 Manifold, Discharge (NPT) 1 15-5035-03 15-5035-03 15-5035-03 15-5035-02 15-5035-02
Manifold, Discharge (BSPT) 1 15-5036-03 15-5036-03 15-5036-03 15-5036-02 15-5036-02
Manifold, Discharge (ANSI) 1 15-5045-03 15-5045-03 15-5045-03 15-5045-02 15-5045-02
Manifold, Discharge (DIN) 1 15-5046-03 15-5046-03 15-5046-03 15-5046-02 15-5046-02 30 Manifold, Inlet (NPT) 1 15-5095-03 15-5095-03 15-5095-03 15-5095-02 15-5095-02
Manifold, Inlet (BSPT) 1 15-5096-03 15-5096-03 15-5096-03 15-5096-02 15-5096-02
Manifold, Inlet (ANSI) 1 15-5125-03 15-5125-03 15-5125-03 15-5125-02 15-5125-02
Manifold, Inlet (DIN) 1 15-5126-03 15-5126-03 15-5126-03 15-5126-02 15-5126-02 31 Screw, HHC (5/8"-11 x 2") 16 15-6180-03 15-6180-03 15-6180-03 15-6180-08 15-6180-08 32 Spring, Disk (5/8") 16 15-6820-03 15-6820-03 15-6820-03 N/A N/A
Washer (Ø.656" x Ø1.312" x .095") 32 N/A N/A NA 15-6732-08 15-6732-08 33 Screw, HHC (1/2"-13 x 1-1/2") 16 04-6180-03 04-6180-03 04-6180-03 N/A N/A
Screw, HHC (5/8"-11 x 1-1/2") 16 N/A N/A N/A 15-6188-08 15-6188-08 34 Spring, Disk (1/2") 16 15-6810-03 15-6810-03 15-6810-03 N/A N/A
GASKETS/VALVE BALLS/VALVE SEATS/VALVE O-RINGS
35 Ball, Valve 4 * * * * * 36 Seat, Valve 4 * * * * *
O-Ring, Valve Seat PTFE-Fitted (-358, Ø5.600" x Ø.210") (not shown)
37
4 15-1209-55 15-1209-55 15-1209-55 15-1209-55 15-1209-55
FULL-STROKE RUBBER/TPE/PTFE COMPONENTS
38 Shaft 1 15-3805-09 15-3805-09 15-3805-09 15-3805-09 15-3805-09
Shaft, IPD 1 15-3814-09 15-3814-09 15-3814-09 15-3814-09 15-3814-09 39 Piston, Inner 2 15-3700-01 15-3700-03 15-3700-01 15-3700-01 15-3700-01
Piston, IPD Inner 2 08-3700-01 08-3700-03 08-3700-01 08-3700-01 08-3700-01 40 Washer, Inner Piston Backup 2 15-6850-08 15-6850-08 15-6850-08 15-6850-08 15-6850-08 41 Screw, HHC (3/8"-16 x 1-1/8") 12 15-6130-08 N/A 15-6130-08 15-6130-08 15-6130-08
Screw, HHC (3/8"-16 x 1") 12 N/A 08-6130-03 N/A N/A N/A 42 Washer (Ø.406" x Ø.812" x .065") 12 15-6740-08-50 04-6740-03 15-6740-08-50 15-6740-08-50 15-6740-08-50
43 Diaphragm, Primary 2 * * * * *
Diaphragm, IPD Primary 2 * * * * * 44 Diaphragm, Backup 2 * * * * *
45 Piston, Outer 2 15-4550-03 15-4550-03 15-4550-03 15-4550-02 15-4550-02
* See elastomer chart - Section 9
1
Air Valve Assembly includes items 2 and 3.
WIL-115 2 0 - E - 0 7 25 WILDEN PUMP & ENGINEERING, LLC
2
Metal Center Block Assembly includes items 13, 14 and 16.
3
Plastic Center Block Assembly includes items 10, 13, 14 and 16.
All boldface items are primary wear parts.
LW0051 Rev. R
Page 28
Section 9
ELASTOMER OPTIONS
PS1520/PS1530 Aluminum
MATERIAL
Polyurethane Neoprene Buna-N Conductive Buna-N Geolast EPDM
®
Viton Full Stroke PTFE Saniflex™ FDA Wil-Flex™ Wil-Flex™ Stainless Steel
1
Used in conjunction with metallic valve seat.
(2)
N/A N/A N/A 15-1022-50 N/A 15-1080-50 15-1126-50 N/A N/A 15-1010-51 N/A N/A N/A N/A 15-1080-51 15-1126-51 N/A 15-1325-51 15-1010-52 N/A N/A N/A N/A 15-1080-52 15-1126-52 N/A 15-1325-52 15-1010-86 N/A N/A N/A N/A N/A N/A N/A N/A
N/A N/A N/A 15-1022-15 N/A N/A N/A N/A N/A 15-1010-54 N/A N/A N/A N/A 15-1080-54 15-1126-54 N/A 15-1325-54 15-1010-53 N/A N/A N/A N/A 15-1080-53 N/A N/A N/A
N/A 15-1040-55-42 N/A N/A N/A 15-1080-55 N/A 15-1205-55 115-1325-55
N/A N/A 15-1065-56 15-1022-56 N/A 15-1080-56 15-1126-56 N/A N/A
N/A N/A 15-1065-57 15-1022-57 15-1031-57 15-1080-57 15-1126-57 N/A 15-1325-57
N/A N/A N/A 15-1022-58 15-1031-58 15-1080-58 15-1126-58 N/A 15-1325-58
N/A N/A N/A N/A N/A N/A 15-1125-03 N/A N/A
DIAPHRAGMS
DIAPHRAGMS
FULL-STROKE
(2)
FULL-STROKE
BACKUP
DIAPHRAGMS
(2)
EZ-INSTALL
DIAPHRAGMS
(2)
FULL-STROKE
IPD
DIAPHRAGMS
(2)
VALVE BALLS
(4)
VALVE
SEATS
(4)
VALVE SEAT
O-RINGS
(4)
PS1520/PS1530 Metal
FULL-STROKE
MATERIAL
DIAPHRAGMS
(2)
FULL-STROKE
DIAPHRAGMS
(2)
BACKUP
DIAPHRAGMS
(2)
EZ-INSTALL
DIAPHRAGMS
(2)
Polyurethane N/A N/A N/A 15-1022-50 N/A N/A N/A N/A Neoprene 15-1010-51 N/A N/A N/A N/A 15-1085-51 15-1128-51 N/A Buna-N 15-1010-52 N/A N/A N/A N/A 15-1085-52 15-1128-52 N/A Conductive Buna-N 15-1010-86 N/A N/A N/A N/A N/A N/A N/A
®
Geolast
N/A N/A N/A 15-1022-15 N/A N/A N/A N/A
EPDM 15-1010-54 N/A N/A N/A N/A 15-1085-54 15-1128-54 N/A
®
Viton
15-1010-53 N/A N/A N/A N/A 15-1085-53 15-1128-53 N/A
PTFE N/A 15-1040-55-42 N/A N/A N/A 15-1085-55 N/A 15-1209-55 Saniflex™ N/A N/A 15-1065-56 15-1022-56 N/A 15-1085-56 15-1128-56 N/A FDA Wil-Flex™ N/A N/A 15-1065-57 15-1022-57 15-1031-57 15-1085-57 15-1128-57 N/A Wil-Flex™ N/A N/A N/A 15-1022-58 15-1031-58 15-1085-58 15-1128-58 N/A Mild Steel N/A N/A N/A N/A N/A N/A 15-1129-08 N/A Stainless Steel N/A N/A N/A N/A N/A N/A 15-1129-03 N/A
1
Used in conjunction with metallic valve seat.
FULL-STROKE
IPD
DIAPHRAGMS
(2)
VALVE BALLS
(4)
VALVE SEATS
(4)
VALVE SEAT
O-RINGS
(4)
LW0051 Rev. R
T-SECTION
GASKET
(4)
LW0049 Rev. R
1
WILDEN PUMP & ENGINEERING, LLC 26 W I L-11520 -E- 07
Page 29
NOTES
Page 30
NOTES
Page 31
WARRANTY
Each and every product manufactured by Wilden Pump and Engineering, LLC is built to meet the highest standards of quality. Every pump is functionally tested to insure integrity of operation.
Wilden Pump and Engineering, LLC warrants that pumps, accessories and parts manufactured or supplied by it to be free from defects in material and workmanship for a period of five (5) years from date of installation or six (6) years from date of manufacture, whichever comes first. Failure due to normal wear, misapplication, or abuse is, of course, excluded from this warranty.
Since the use of Wilden pumps and parts is beyond our control, we cannot guarantee the suitability of any pump or part for a particular application and Wilden Pump and Engineering, LLC shall not be liable for any consequential damage or expense arising from the use or misuse of its products on any application. Responsibility is limited solely to replacement or repair of defective Wilden pumps and parts.
All decisions as to the cause of failure are the sole determination of Wilden Pump and Engineering, LLC.
Prior approval must be obtained from Wilden for return of any items for warranty consideration and must be accompanied by the appropriate MSDS for the product(s) involved. A Return Goods Tag, obtained from an authorized Wilden distributor, must be included with the items which must be shipped freight prepaid.
The foregoing warranty is exclusive and in lieu of all other warranties expressed or implied (whether written or oral) including all implied warranties of merchantability and fitness for any particular purpose. No distributor or other person is authorized to assume any liability or obligation for Wilden Pump and Engineering, LLC other than expressly provided herein.
PLEASE PRINT OR TYPE AND FAX TO WILDEN
PUMP INFORMATION
Item # Serial #
Company Where Purchased
YOUR INFORMATION
Company Name
Industry
Name Title
Street Address
City State Postal Code C ountry
Telephone Fax E-mail Web Address
Number of pumps in facility? Number of Wilden pumps?
Types of pumps in facility (check all that apply): Diaphragm
Media being pumped?
Other
Centrifugal
Gear
Submersible
Lobe
How did you hear of Wilden Pump?
Other
Trade Journal
Trade Show
Internet/ E-mail
Distributor
ONCE COMPLETE, FAX TO (909) 783-3440
OR GO TO PSGDOVER.COM > WILDEN > SUPPORT TO COMPLETE THE WARRANTY REGISTRATION ONLINE
NOTE: WARRANTY VOID IF PAGE IS NOT FA XED TO WILDEN OR SUBMIT TED ONLINE VIA THE PSGDOVER.COM WEBSITE
WILDEN PUMP & ENGINEERING, LLC
Page 32
PSG
22069 Van Buren St., Grand Terrace, CA 92313-5607
P: +1 (909) 422-1730
• F: +1 (909) 783-3440
wildenpump.com
Where Innovation Flows
PSG® reserves the right to modify the information and illustrations contained in this document without prior notice. This is a non-contractual document. 06-2017
Authorized PSG Representative:
Copyrigh t ©20 17, P S G®, A Dover Compa ny
REPL ACES WIL-11520-E -06
WI L-115 20 -E -0 7