excess lub rication will reduce pump pe rformance.
Pump is pre-lubed.
TEMPERATURE LIMITS:
Acetal –29°C to 82°C –20°F to 180°F
Buna-N –12°C to 82°C 10°F to 180°F
Geolast
®
–40°C to 82°C –40°F to 180°F
Neoprene –18°C to 93°C 0°F to 200°F
Nordel
®
EPDM –51°C to 138°C –60°F to 280°F
Nylon –18°C to 93°C 0°F to 200°F
PFA –7°C to 107°C 45°F to 225°F
Polypropylene 0°C to 79°C 32°F to 175°F
Polyurethane –12°C to 66°C 10°F to 150°F
PVDF –12°C to 107°C 10°F to 225°F
Saniflex™ –29°C to 104°C –20°F to 220°F
SIPD PTFE with EPDM-backed
SIPD PTFE with Neoprene-backed
PTFE
Viton
1
4°C to 104°C 40°F to 220°F
®
FKM –40°C to 177°C –40°F to 350°F
4°C to 137°C 40°F to 280°F
4°C to 93°C 40°F to 200°F
Wil-Flex™ –40°C to 107°C –40°F to 225°F
1
4°C to 149°C (40°F to 300°F) - 13 mm (1/2") and 25 mm (1") models only.
CAUTION: Do not exceed 82°C (180°F) air inlet
®
temperature for Pro-Flo
SHIFT models.
CAUTION: Pumps should be thoroughly flushed
before installing into process lines. FDA- and
USDA-approved pumps should be cleaned and /
or sanitized before being used.
CAUTION: Always wear safety glasses when
operating pump. If diaphragm rupture occurs,
material being pumped may be forced out air
exhaust.
CAUTION: Before any maintenance or repair is
attempted, the compressed air line to the pump
should be disconnected and all air pressure
allowed to bleed from pump. Disconnect all
intake, discharge and air lines. Drain the pump
by turning it upside down and allowing any fluid
to flow into a suitable container.
CAUTION: Blow out air line for 10 to 20 seconds
before attaching to pump to make sure all pipeline
debris is clear. Use an in-line air filter. A 5μ
(micron) air filter is recommended.
NOTE:
Not all materials are available for all models.
Refer to Section 2 for material options for your pump.
CAUTION: When choosing pump materials, be
sure to check the temperature limits for all wetted
components. Example: Viton
®
has a maximum
limit of 177°C (350°F) but polypropylene has a
maximum limit of only 79°C (175°F).
CAUTION: Maximum temperature limits are
based upon mechanical stress only. Certain
chemicals will significantly reduce maximum
safe operating temperatures. Please consult the
Wilden Chemical Resistance Guide.
WARNING : Prevent static sparking. If static
sparking occurs, fire or explosion could result.
Pump, valves and containers must be grounded
to a proper grounding point when handling
flammable fluids and whenever discharge of
static electricity is a hazard.
CAUTION: Do not exceed 8.6 bar (125 psig) air
supply pressure.
CAUTION: The process fluid and cleaning fluids
must be chemically compatible with all wetted
pump components. Please consult the Wilden
Chemical Resistance Guide.
NOTE: When installing PTFE diaphragms, it is
important to tighten outer pistons simultaneously
(turning in opposite directions) to ensure tight fit.
(See torque specifications in Section 7.)
NOTE: Some PTFE-fitted pumps come standard
from the factory with expanded PTFE gaskets
installed in the diaphragm bead of the liquid
chamber. PTFE gaskets cannot be re-used.
NOTE: Before starting disassembly, mark a line
from each liquid chamber to its corresponding air
chamber. This line will assist in proper alignment
during reassembly.
CAUTION: Pro-Flo® pumps cannot be used
in submersible applications. Pro-Flo® SHIFT
pumps do have a single-point exhaust option
for submersible applications. Do not use
standard Pro-Flo® SHIFT models in submersible
applications.
CAUTION : Tighten all hardware prior to installation.
The Wilden diaphragm pump is an air-operated, positive displacement, self-priming pump. These drawings show flow pattern
through the pump upon its initial stroke. It is assumed the pump has no fluid in it prior to its initial stroke.
CLOSED
OUTLET
OPEN
BA
INLET
FIGUR E 1 The air valve dire cts pre ssurized
air to the back side of diaphragm A. The
compressed air is applied directly to the
liquid column separated by elastomeric
diaphragms. The diaphragm ac ts as
a separation membrane bet ween the
compressed air and liquid; a balanced
load removes mechanical stress from the
diaphragm. The compressed air moves
the diaphragm away from the center
of the pump. The opposite diaphragm
is pulled in by the shaft connected to
the pressurized diaphragm. Diaphragm
B is on its suction stroke; air behind
the diaphragm has been forced out to
atmosphere through the exhaust port of
the pump. The movement of diaphragm
B toward the center of the pump creates
a vacuum within chamber B. A tmosphe ric
pressure forces fluid into the inlet
manifold forcing the inlet valve ball off its
seat. Liquid is free to move past the inlet
valve ball and fill the liquid chamber (see
shaded area).
CLOSEDOPEN
OPEN
OUTLET
CLOSED
BA
CLOSEDOPEN
FIGURE 2
phragm
, diaphragm A, reaches the limit
of its discharge stroke, the air valve
redirects pressurized air to the back side of
diaphragm B. The pressurized air forces
diaphragm B away from the center
while pulling diaphragm A to the center.
Diaphragm B is now on its discharge
stroke. Diaphragm B forces the inlet valve
ball onto its seat due to the hydraulic
forces developed in the liquid chamber
and manifold of the pump. These same
hydraulic forces lift the discharge valve
ball off its seat, while the opposite
discharge valve ball is forced onto its seat,
forcing fluid to flow through the pump
discharge. The movement of diaphragm A
toward the center of the pump creates a
vacuum within liquid chamber A. Atmospheric pressure forces fluid into the inlet
manifold of the pump. The inlet valve ball
is forced off its seat allowing the fluid
being pumped to fill the liquid chamber.
INLET
When the pressurized dia-
CLOSEDOPEN
OUTLET
BA
OPEN
FIGURE 3 At completion of the stroke,
the air valve again redirects air to the
back side of diaphragm A, which starts
diaphragm B on its exhaust stroke. As
the pump reaches its original star ting
point, each diaphragm has gone through
one exhaust and one discharge stroke.
This constitutes one complete pumping
cycle. The pump may take several cycles
to completely prime depending on the
conditions of the application.
INLET
CLOSED
HOW IT WORKS—AIR DISTRIBUTION SYSTEM
The heart of the patented Pro-Flo® SHIFT Air Distribution
System (ADS) is the air valve assembly. The air valve design
incorporates an unbalanced spool with the small end of the
spool being pressurized continuously while the large end of
the spool is alternately pressurized, then exhausted to move
the spool. The air valve spool directs pressurized air to one
chamber while exhausting the other. The air forces the main
shaft/diaphragm assembly to move to one side – discharging
liquid on that side and pulling liquid in on the other side. When
the shaft reaches the end of the stroke, the inner piston actuates
the pilot spool, which controls the air to the large end of the air
valve spool. The repositioning of the air valve spool routes the
air to the other air chamber. The air control spool allows air to
flow freely into the air chamber for the majority of each pump
stroke, but it significantly restricts the flow of air into the air
chamber when activated by the inner piston near the end of the
each stroke.
Suction-lift curves are calibrated for
pumps operating at 305 m (1,000')
above sea level. This chart is meant
to be a guide only. There are many
variables that can affect your pump's
operating characteristics. The number
of intake and discharge elbows,
viscosity of pumping fluid, elevation
(atmospheric pressure) and pipe
friction loss all affect the amount of
suction lift your pump will attain.
Suction-lift curves are calibrated for
pumps operating at 305 m (1,000')
above sea level. This chart is meant
to be a guide only. There are many
variables that can affect your pump's
operating characteristics. The number
of intake and discharge elbows,
viscosity of pumping fluid, elevation
(atmospheric pressure) and pipe
friction loss all affect the amount of
suction lift your pump will attain.
PS1520/PS1530
DUCTILE IRON
SUCTION-LIFT
CAPABILITY
Suction-lift curves are calibrated for
pumps operating at 305 m (1,000')
above sea level. This chart is meant
to be a guide only. There are many
variables that can affect your pump's
operating characteristics. The number
of intake and discharge elbows,
viscosity of pumping fluid, elevation
(atmospheric pressure) and pipe
friction loss all affect the amount of
suction lift your pump will attain.
WILDEN PUMP & ENGINEERING, LLC 10
WIL-115 2 0 - E - 0 7
Page 13
SUGGESTED INSTALLATION
Wilden pumps are designed to meet the performance
requirements of even the most demanding pumping
applications. They have been designed and manufactured
to the highest standards and are available in a variety of
liquid-path materials to meet your chemical-resistance
needs. Refer to the performance section of this manual for
an in-depth analysis of the performance characteristics of
your pump. Wilden offers the widest variety of elastomer
options in the industry to satisfy temperature, chemicalcompatibility, abrasion-resistance and flex concerns.
The suction pipe size should be at least the equivalent or
larger than the diameter size of the suction inlet on your
Wilden pump. The suction hose must be non-collapsible,
reinforced type as these pumps are capable of pulling a high
vacuum. Discharge piping should also be the equivalent
or larger than the diameter of the pump discharge which
will help reduce friction losses. It is critical that all fittings
and connections are airtight or a reduction or loss of pump
suction capability will result.
INSTALLATION: Months of careful planning, study
and selection efforts can result in unsatisfactory pump
performance if installation details are left to chance.
Premature failure and long-term dissatisfaction can be
avoided if reasonable care is exercised throughout the
installation process.
LOCATION: Noise, safety and other logistical factors usually
dictate where equipment will be situated on the production
floor. Multiple installations with conflicting requirements
can result in congestion of utility areas, leaving few choices
for additional pumps.
Within the framework of these and other existing conditions,
every pump should be located in such a way that six key
factors are balanced against each other to maximum
advantage.
ACCESS: First of all, the location should be accessible. If
it’s easy to reach the pump, maintenance personnel will
have an easier time carrying out routine inspections and
adjustments. Should major repairs become necessary, ease
of access can play a key role in speeding the repair process
and reducing total downtime.
AIR SUPPLY: Every pump location should have an air line
large enough to supply the volume of air necessary to
achieve the desired pumping rate. Use air pressure up to
a maximum of 8.6 bar (125 psig) depending on pumping
requirements.
For best results, the pumps should use a 5µ (micron) air
filter, needle valve and regulator. The use of an air filter
before the pump will ensure that the majority of any pipeline
contaminants will be eliminated.
SOLENOID OPERATION: When operation is controlled by a
solenoid valve in the air line, three-way valves should be
used. This valve allows trapped air between the valve and
the pump to bleed off which improves pump performance.
Pumping volume can be estimated by counting the number
of strokes per minute and then multiplying the figure by the
displacement per stroke.
MUFFLER: Sound levels are reduced below OSHA
specifications using the standard Wilden muffler. Other
mufflers can be used to further reduce sound levels, but
they usually reduce pump performance.
ELEVATION: Selecting a site that is well within the pump’s
dynamic-lift capability will assure that loss-of-prime issues will
be eliminated. In addition, pump efficiency can be adversely
affected if proper attention is not given to site location.
PIPING: Final determination of the pump site should not be
made until the piping challenges of each possible location
have been evaluated. The impact of current and future
installations should be considered ahead of time to make
sure that inadvertent restrictions are not created for any
remaining sites.
The best choice possible will be a site involving the
shortest and straightest hookup of suction and discharge
piping. Unnecessary elbows, bends and fittings should
be avoided. Pipe sizes should be selected to keep friction
losses within practical limits. All piping should be supported
independently of the pump. In addition, the piping should
be aligned to avoid placing stress on the pump fittings.
Flexible hose can be installed to aid in absorbing the forces
created by the natural reciprocating action of the pump. If the
pump is to be bolted down to a solid location, a mounting
pad placed between the pump and the foundation will assist
in minimizing pump vibration. Flexible connections between
the pump and rigid piping will also assist in minimizing
pump vibration. If quick-closing valves are installed at any
point in the discharge system, or if pulsation within a system
becomes a problem, a surge suppressor (SD Equalizer
®
)
should be installed to protect the pump, piping and gauges
from surges and water hammer.
If the pump is to be used in a self-priming application, make
sure that all connections are airtight and that the suction lift is
within the model’s ability. NOTE: Materials of construction and
elastomer material have an effect on suction lift parameters.
Please refer to the performance section for specifics.
When pumps are installed in applications involving flooded
suction or suction head pressures, a gate valve should be
installed in the suction line to permit closing of the line for
pump service.
Pumps in service with a positive suction head are most efficient
when inlet pressure is limited to 0.5–0.7 bar (7–10 psig).
Premature diaphragm failure may occur if positive suction
is 0.7 bar (10 psig) and higher.
SUBMERSIBLE APPLICATIONS: Pro-Flo
®
SHIFT pumps can
be used for submersible applications when using the ProFlo® SHIFT single-point exhaust option.
ALL WILDEN PUMPS ARE CAPABLE OF PASSING SOLIDS.
A STRAINER SHOULD BE USED ON THE PUMP INTAKE TO
ENSURE THAT THE PUMP'S RATED SOLIDS CAPACITY IS
NOT EXCEEDED.
CAUTION: DO NOT EXCEED 8.6 BAR (125 PSIG) AIR
SUPPLY PRESSURE.
This illustration is a generic
representation of an air-operated
double-diaphragm pump.
MUFFLER
FLEXIBLE
CONNECTION
SUCTION
EQUALIZER
SURGE DAMPENER
(OPTIONAL)
GAUGE
(OPTIONAL)
SHUT-OFF
VALVE
FLEXIBLE
CONNECTION
NEEDLE VALVE
COMBINATION
FILTER & REGULATOR
AIR SHUT-OFF VALVE
NOTE: In the event of a power failure, the shut-off
valve should be closed, if the restarting of the pump is
not desirable once power is regained.
AIR-OPERATED PUMPS: To stop the pump from
operating in an emergency situation, simply close
the shut-off valve (user-supplied) installed in the air
supply line. A properly functioning valve will stop the
air supply to the pump, therefore stopping output. This
shut-of f valve should be located far enough away from
the pumping equipment such that it can be reached
safely in an emergency situation.
OPERATION: The Pro-Flo® SHIFT pumps are prelubricated and do not require in-line lubrication.
Additional lubrication will not damage the pump;
however if the pump is heavily lubricated by an
external source, the pump’s internal lubrication may
be washed away. If the pump is then moved to a nonlubricated location, it may need to be disassembled
and re-lubricated as described in the DISASSEMBLY/
REASSEMBLY INSTRUCTIONS.
Pump discharge rate can be controlled by limiting
the volume and/or pressure of the air supply to the
pump. An air regulator is used to regulate air pressure.
A needle valve is used to regulate volume. Pump
discharge rate can also be controlled by throttling
the pump discharge by partially closing a valve in
the discharge line of the pump. This action increases
friction loss which reduces flow rate. (See Section
5.) This is useful when the need exists to control
the pump from a remote location. When the pump
discharge pressure equals or exceeds the air supply
pressure, the pump will stop; no bypass or pressure
relief valve is needed, and pump damage will not
occur. The pump has reached a “deadhead” situation
and can be restarted by reducing the fluid discharge
pressure or increasing the air inlet pressure. Wilden
Pro-Flo® SHIFT pumps run solely on compressed air
and do not generate heat; therefore, your process fluid
temperature will not be affected.
MAINTENANCE AND INSPECTIONS: Since each
application is unique, maintenance schedules may
be different for every pump. Frequency of use, line
pressure, viscosity and abrasiveness of process fluid
all affect the parts life of a Wilden pump. Periodic
inspections have been found to offer the best
means for preventing unscheduled pump downtime.
Personnel familiar with the pump’s construction and
service should be informed of any abnormalities that
are detected during operation.
RECORDS: When service is required, a record should
be made of all necessary repairs and replacements.
Over a period of time, such records can become a
valuable tool for predicting and preventing future
maintenance problems and unscheduled downtime. In
addition, accurate records make it possible to identify
pumps that are poorly suited to their applications.
TROUBLESHOOTING
Pump will not run or runs slowly.
1. Ensure that the air inlet pressure is at least 0.4 bar
(5 psig) above startup pressure and that the differential
pressure (the difference between air inlet and liquid
discharge pressures) is not less than 0.7 bar (10 psig).
2. Check air inlet filter for debris (see SUGGESTED
INSTALLATION).
3. Check for extreme air leakage (blow by) that would
indicate worn seals /bores in the air valve, pilot
spool and main shaft.
4. Disassemble pump and check for obstructions in
the air passageways or objects that would obstruct
the movement of internal parts.
5. Check for sticking ball check valves. If material being
pumped is not compatible with pump elastomers,
swelling may occur. Replace ball check valves and
seals with proper elastomers. Also, as the check
valve balls wear out, they become smaller and can
become stuck in the seats. In this case, replace balls
and seats.
6. Check for broken inner pistons that would cause the
air valve spool to be unable to shift.
7. Remove plug from pilot spool exhaust.
Pump runs but little or no product flows.
1. Check for pump cavitation; slow pump speed down
to allow thick material to flow into liquid chambers.
2. Verify that vacuum required to lift liquid is not
greater than the vapor pressure of the material
being pumped (cavitation).
3. Check for sticking ball check valves. If material being
pumped is not compatible with pump elastomers,
swelling may occur. Replace ball check valves and
seats with proper elastomers. Also, as the check
valve balls wear out, they become smaller and can
become stuck in the seats. In this case, replace balls
and seats.
Pump air valve freezes.
1. Check for excessive moisture in compressed
air. Either install a dryer or hot air generator for
compressed air. Alternatively, a coalescing filter
may be used to remove the water from the
compressed air in some applications.
Air bubbles in pump discharge.
1. Check for ruptured diaphragm.
2. Check tightness of outer pistons (refer to Section 7).
3. Check tightness of fasteners and integrity of
O-rings and seals, especially at intake manifold.
• Vise equipped w /
soft jaws (such as
plywood, plastic
or other suitable
material)
CAUTION: Before any maintenance or repair is attempted, the compressed air line
to the pump should be disconnected and all air pressure allowed to bleed from the
pump. Disconnect all intake, discharge and air lines. Drain the pump by turning it
upside down and allowing any fluid to flow into a suitable container. Be aware of
any hazardous effects of contact with your process fluid.
NOTE: The model photographed is an aluminum PX820 51 mm (2”) pump. Your
specific pump model may vary from the configuration shown; however, pump
disassembly procedure will be the same.
Step 1
Before starting disassembly, mark
a line from each liquid chamber to
its corresponding air chamber. This
line will assist in proper alignment
during reassembly.
Using the appropriate-sized wrench
for your pump size, loosen the
discharge manifold from the liquid
chambers.
Step 3
Lift the discharge manifold to
expose discharge valve balls and
valve seats. Inspect ball cage area
of manifold for excessive wear or
damage.
Page 17
PUMP DISASSEMBLY
Step 4
Remove the discharge valve balls
and valve seats from the liquid
chambers and inspect for nicks,
gouges, chemical attack or abrasive
wear. Replace worn parts with
genuine Wilden parts for reliable
performance.
Step 5
Using the appropriate-sized wrench,
loosen the inlet manifold from the
liquid chambers. NOTE: Inverting
the pump will facilitate removal of
inlet manifold.
Step 6
Remove the inlet manifold to expose
the valve balls and valve seats.
Step 7
Remove the inlet valve balls and
valve seats from the inlet manifold
and liquid chambers and inspect for
nicks, gouges, chemical attack or
abrasive wear.
NOTE: Replace worn parts with
genuine Wilden parts for reliable
performance.
Using an appropriately-sized
wrench, remove the liquid chamber
from the center section.
Step 9
The liquid chamber should be
removed to expose the diaphragm
and outer piston using an adjustable
wrench. Remove the diaphragm
assembly from the center section.
Repeat for opposite side.
Page 18
PUMP DISASSEMBLY
Step 10
Inspect the diaphragm assembly for
wear, damage or chemical attack.
Replace any damaged components
with genuine Wilden parts for
reliable performance.
Step 11
To remove diaphragm assembly
from shaft, secure shaft with
soft jaws (aluminum, plastic or
plywood) to ensure the shaft is
not damaged. Using an adjustable
wrench, remove the diaphragm
assembly from the shaft.
Step 12
Remove outer piston and stud if
equipped. Inspect for wear and
replace if necessary.
CAUTION: Before any maintenance or repair is attempted, the compressed air line
to the pump should be disconnected and all air pressure allowed to bleed from the
pump. Disconnect all intake, discharge and air lines. Drain the pump by turning it
upside down and allowing any fluid to flow into a suitable container. Be aware of
hazardous effects of contact with your process fluid.
®
The Wilden Pro-Flo
SHIFT metal pumps utilize a revolutionary Pro-Flo® air
distribution system. Proprietary composite seals reduce the co efficient of friction
and allow the Pro-Flo® SHIFT to run lube-free. The Pro-Flo® air distribution system is
designed to perform in on/off, non-freezing, non-stalling, tough duty applications.
Step 1
Using a pair of snap-ring pliers,
remove the snap-ring from pilot
sleeve.
Step 2
Using an O-ring pick, remove O-ring
from modulator spool.
Step 3
Using the appropriate-sized wrench,
loosen and remove the fasteners
that attach the air chamber to center
section.
Lift away air chamber from center
section and remove center block
gasket. Replace gasket if necessary.
Step 5
Turn assembly over and remove the
pilot spool sleeve from the center
section.
Step 6
Using an O-ring pick, gently remove
the O-ring from the opposite side of
the dimpled end of the pilot spool.
Step 7
Gently remove the pilot spool from
the sleeve and inspect for nicks,
wear or damage. Replace the pilot
spool assembly or sleeve O-rings
if necessary. During reassembly,
never insert the dimpled end of the
pilot spool first, this will damage the
single urethane O-ring by passing it
over the ports in the pilot sleeve.
NOTE: Seals should not be removed
from the assembly. Seals are not
sold separately.
Remove modulator spool from
center section. Check for wear to
spool or O-rings and replace if
necessary.
Step 9
Using the appropriate-sized wrench,
loosen the fasteners and lift away
remaining air chamber and center
block gasket from center section.
Replace gasket if necessary.
Page 21
AIR VALVE / CENTER SECTION DISASSEMBLY
Step 10
Using an O-ring pick, remove
the two (2) shaft bushings from
center block. Inspect and replace
if necessary. Using an O-ring pick,
gently remove the two (2) Glyd™
rings from the center block. Inspect
and replace if necessary.
Step 11
Using an O-ring pick, remove the
two (2) Glyd™ rings from modulator
spool bore. Inspect and replace if
necessary.
Step 12
Using an appropriate-sized wrench,
remove the pilot exhaust muffler.
Inspect for damage or contamination
and replace if necessary.
Step 13
Using an appropriate-sized hex
wrench, loosen and remove the
four (4) air valve bolts from center
section assembly.
Lift away muffler plate and muffler plate gasket from center block. Inspect
for wear and replace if necessary. Lift away the air valve assembly and
remove air valve gasket. Inspect the gasket and replace if necessary.
Page 22
AIR VALVE / CENTER SECTION DISASSEMBLY
Step 15
Remove air valve end cap to expose
air valve spool by lifting up on end
cap. Inspect O-ring on end cap using
an O-ring pick. Replace O-ring(s)
if necessary. NOTE: The Pro-Flo
SHIFT air valve incorporates an end
cap at both ends of the air valve.
Step 16
Remove the air valve spool from the air valve body by threading one air
valve bolt into the end of the air valve spool and gently sliding the spool out
of the air valve body. Inspect seals for signs of wear and replace the entire
air valve assembly if necessary. Re-insert the spool immediately into air
®
valve body after inspection as the seals expand and cannot be reinserted
after a length of time.
NOTE: Seals should not be removed from the assembly. Seals are not sold
separately.
SINGLE-POINT EXHAUST PRO-FLO® SHIFT
StandardSingle-Point Exhaust
Step 1
Remove pilot exhaust muffler in
pilot bleed port located at the front
of the center block. Install 1/4" NPT
pipe plug (00-7010-08) into bleed
Step 2
Next, install an optional single-point exhaust air
valve gasket (04-2639-52). The single-point air valve
gasket can be purchased as a spare part or included
Upon performing applicable maintenance to the air
distrib ution system, t he pump can now be re assembled .
Please refer to the disassembly instructions for photos
and parts placement. To reassemble the pump, follow
the disassembly instructions in reverse order. The air
distribution system needs to be assembled first, then
the diaphragms and finally the wetted path. Please
find the applicable torque specifications on this page.
The following tips will assist in the assembly process.
• Lubricate air valve bore, center section shaft
and pilot spool bore with NLGI grade 2 white EP
bearing grease or equivalent.
• Clean the inside of the center section shaft bore to
ensure no damage is done to new shaft seals.
• A small amount of NLGI grade 2 white EP bearing
grease can be applied to the muffler and air valve
gaskets to lubricate gaskets during assembly.
• Make sure that the exhaust port on the muffler plate
is centered between the two exhaust ports on the
center section.
• Stainless steel bolts should be lubed to reduce the
possibility of seizing during tightening.
PRO-FLO® SHIFT MAXIMUM TORQUE SPECIFICATIONS
Description of PartTorque
Air Valve (A luminum, Stainless Steel )13.6 N•m (120 in-lb)
Air Valve (Polypropylene)5.1 N•m (45 in-lb)
Air Chamber/Center Block27.1 N•m(20 ft-lb)
Manifold/Liquid Chamber149 N•m(110 ft-lb)
Inner Piston Ring19.0 N•m (14 ft-lb)
Outer Pistons, Rubber & PTF E136 N•m (100 ft-lb)
Figure A
SHA FT SE AL
SHAFT SEAL INSTALLATION:
PRE-INSTALLATION
• Once all of the old seals have been removed, the
inside of the bushing should be cleaned to ensure
no debris is left that may cause premature damage
to the new seals.
INSTALLATION
The following tools can be used to aid in the installation
of the new seals:
• Wrap electrical tape around each leg of the needle-nose
pliers (heat shrink tubing may also be used). This is done
to prevent damaging the inside surface of the new seal.
• With a new seal in hand, place the two legs of the
needle-nose pliers inside the seal ring. (See Figure A.)
• Open the pliers as wide as the seal diameter will allow,
then with two fingers pull down on the top portion of
the seal to form a kidney shape. (See Figure B.)
• Lightly clamp the pliers together to hold the seal into
the kidney shape. Be sure to pull the seal into as tight
of a kidney shape as possible, this will allow the seal to
travel down the bushing bore with greater ease.
• With the seal clamped in the pliers, insert the seal into
the bushing bore and position the bottom of the seal
into the correct groove. Once the bottom of the seal is
seated in the groove, release the clamp pressure on the
pliers. This will allow the seal to partially snap back to its
original shape.
• After the pliers are removed, you will notice a slight
bump in the seal shape. Before the seal can be properly
resized, the bump in the seal should be removed as
much as possible. This can be done with either the
Phillips screwdriver or your finger. With either the side
of the screwdriver or your finger, apply light pressure
to the peak of the bump. This pressure will cause the
bump to be almost completely eliminated.
• Lubricate the edge of the shaft with NLGI grade 2
white EP bearing
• Slowly insert the center shaft with a rotating motion.
This will complete the resizing of the seal.
PTFEN/A15-1040-55-42N/AN/AN/A15-1085-55N/A15-1209-55
Saniflex™N/AN/A15-1065-5615-1022-56N/A15-1085-5615-1128-56N/A
FDA Wil-Flex™N/AN/A15-1065-5715-1022-5715-1031-5715-1085-5715-1128-57N/A
Wil-Flex™N/AN/AN/A15-1022-5815-1031-5815-1085-5815-1128-58N/A
Mild SteelN/AN/AN/AN/AN/AN/A15-1129-08N/A
Stainless SteelN/AN/AN/AN/AN/AN/A15-1129-03N/A
1
Used in conjunction with metallic valve seat.
FULL-STROKE
IPD
DIAPHRAGMS
(2)
VALVE
BALLS
(4)
VALVE
SEATS
(4)
VALVE SEAT
O-RINGS
(4)
LW0051 Rev. R
T-SECTION
GASKET
(4)
LW0049 Rev. R
1
WILDEN PUMP & ENGINEERING, LLC 26W I L-11520 -E- 07
Page 29
NOTES
Page 30
NOTES
Page 31
WARRANTY
Each and every product manufactured by Wilden Pump and Engineering, LLC is built to meet the highest
standards of quality. Every pump is functionally tested to insure integrity of operation.
Wilden Pump and Engineering, LLC warrants that pumps, accessories and parts manufactured or supplied by
it to be free from defects in material and workmanship for a period of five (5) years from date of installation or
six (6) years from date of manufacture, whichever comes first. Failure due to normal wear, misapplication, or
abuse is, of course, excluded from this warranty.
Since the use of Wilden pumps and parts is beyond our control, we cannot guarantee the suitability of any pump
or part for a particular application and Wilden Pump and Engineering, LLC shall not be liable for any consequential
damage or expense arising from the use or misuse of its products on any application. Responsibility is limited
solely to replacement or repair of defective Wilden pumps and parts.
All decisions as to the cause of failure are the sole determination of Wilden Pump and Engineering, LLC.
Prior approval must be obtained from Wilden for return of any items for warranty consideration and must be
accompanied by the appropriate MSDS for the product(s) involved. A Return Goods Tag, obtained from an
authorized Wilden distributor, must be included with the items which must be shipped freight prepaid.
The foregoing warranty is exclusive and in lieu of all other warranties expressed or implied (whether written or oral)
including all implied warranties of merchantability and fitness for any particular purpose. No distributor or other
person is authorized to assume any liability or obligation for Wilden Pump and Engineering, LLC other than expressly
provided herein.
PLEASE PRINT OR TYPE AND FAX TO WILDEN
PUMP INFORMATION
Item # Serial #
Company Where Purchased
YOUR INFORMATION
Company Name
Industry
Name Title
Street Address
City State Postal Code C ountry
Telephone Fax E-mail Web Address
Number of pumps in facility? Number of Wilden pumps?
Types of pumps in facility (check all that apply): Diaphragm
Media being pumped?
Other
Centrifugal
Gear
Submersible
Lobe
How did you hear of Wilden Pump?
Other
Trade Journal
Trade Show
Internet/ E-mail
Distributor
ONCE COMPLETE, FAX TO (909) 783-3440
OR GO TO PSGDOVER.COM > WILDEN > SUPPORT TO COMPLETE THE WARRANTY REGISTRATION ONLINE
NOTE: WARRANTY VOID IF PAGE IS NOT FA XED TO WILDEN OR SUBMIT TED ONLINE VIA THE PSGDOVER.COM WEBSITE