Dover PSG Wilden GPS220, PSG Wilden GP Series, PSG Wilden GPS1, PSG Wilden GPS230 Engineering, Operation & Maintenance

Page 1
EOM
Engineering
Operation &
Maintenance
Natural Gas-Operated
CSA-Certied
Where Innovation Flows
wildenpump.com
Page 2
TABLE OF CONTENTS
SECTION 1 CAUTIONS—READ FIRST! ..............................................1
SECTION 2 WILDEN PUMP DESIGNATION SYSTEM .................................2
SECTION 3 HOW IT WORKS—PUMP & AIR DISTRIBUTION SYSTEM ................3
SECTION 4 DIMENSIONAL DRAWINGS .............................................4
SECTION 5 PERFORMANCE
GPS1 Metal Rubber-Fitted ..................................................6
GPS1 Metal PTFE-Fitted ....................................................6
GPS220/GPS230 Metal Rubber-Fitted .........................................7
GPS220/GPS230 Metal Full-Stroke PTFE-Fitted .................................7
Suction-Lift Curves ........................................................8
SECTION 6 SUGGESTED INSTALLATION, OPERATION & TROUBLESHOOTING ........9
SECTION 7 DISASSEMBLY / REASSEMBLY ........................................12
Reassembly Hints & Tips ..................................................19
SECTION 8 EXPLODED VIEW & PARTS LISTING
GPS1 Metal .............................................................20
GPS220/GPS230 Metal ....................................................22
SECTION 9 REPAIR KITS ..........................................................28
Page 3
Section 1
CAUTIONS—READ FIRST!
CAUTION: Do not apply pressurized gas to the
exhaust port — pump will not function.
TEMPERATURE LIMITS:
Buna-N –12°C to 82°C 10°F to 180°F
Polytetrafluoroethylene (PTFE)1 4°C to 104°C 40°F to 220°F
1
4°C to 149°C (40°F to 300°F) - 13 mm (1/2") and 25 mm (1") models only.
CAUTION: Canadian Standards Association
(CSA) configured pumps should not be used in temperatures lower than 0°C (32°F) or higher than 52°C (125°F).
CAUTION: Maximum temperature limits are based
upon mechanical stress only. Certain chemicals will significantly reduce maximum safe operating temperatures. Consult Chemical Resistance Guide for chemical compatibility and temperature limits.
WARNING: Prevent static sparking — If static
sparking occurs, fire or explosion could result. Pump, valves and containers must be grounded to a proper grounding point when handling flammable fluids and whenever discharge of static electricity is a hazard. Pumps must be electrically grounded using the grounding conductor provided. Improper grounding can cause improper and dangerous operation.
CAUTION: Do not exceed 8.6 bar (125 psig) air
supply pressure.
CAUTION: Always wear safety glasses when
operating pump. If diaphragm rupture occurs, material being pumped may be forced out air exhaust.
CAUTION: Before any maintenance or repair is
attempted, the compressed air line to the pump should be disconnected and all air pressure allowed to bleed from pump. Disconnect all intake, discharge and air lines. Drain the pump by turning it upside down and allowing any fluid to flow into a suitable container.
CAUTION: Ensure that the gas supply line is clear
of debris. Use an in-line air filter. A 5μ (micron) air filter is recommended.
NOTE: When installing PTFE diaphragms,
it is important to tighten the outer pistons simultaneously (turning in opposite directions) to ensure a tight fit. (See torque specifications)
NOTE: Some PTFE-fitted pumps come standard
from the factory with expanded PTFE gaskets installed in the diaphragm bead of the liquid chamber. PTFE gaskets cannot be re-used.
NOTE: Before starting disassembly, mark a line
from each liquid chamber to its corresponding air chamber. This line will assist in proper alignment during reassembly.
CAUTION: The process fluid and cleaning fluids
must be chemically compatible with all wetted pump components. Consult Chemical Resistance Guide.
CAUTION: Do not exceed 82°C (180°F) air inlet
temperature for all models.
CAUTION: Pumps should be thoroughly flushed
before installing into process lines.
WIL-17011-E-01 1 WILDEN PUMP & ENGINEERING, LLC
CAUTION: All CSA-certified pumps are fitted with
a single-point exhaust to route all exhaust gas through the muffler exhaust port. The gas outlet must be vented to a safe location in accordance with local codes or, in the absence of local codes, an industry or nationally recognized code having jurisdiction over the specified installation.
CAUTION: Tighten all hardware prior to installation.
Page 4
Section 2
`
WILDEN PUMP DESIGNATION SYSTEM
CSA-CERTIFIED METAL PUMPS
Maximum Flow Rates: 13 mm (1/2”)
60.2 lpm (15.9 gpm)
25 mm (1”) 204 lpm (54 gpm)
LEGEND
GPXXXX / X X XXX / XXX / XX/XXX / XXXX
MODEL
MATERIAL CODES
MODEL
GPS1 = ATEX, C SA ,
GPS22 0 = ATE X , CSA ,
GPS23 0 = ATE X , CSA ,
WETTED PARTS & OUTER PISTON
AA = ALUMINUM / ALUMINUM SS = STAINLESS STEEL /
PRO-FLO SHIFT
PRO-FLO SHIF T (THRE ADED)
PRO-FLO SHIF T (FL ANGED)
STAINLESS STEEL
DIAPHRAGMS
AIR VALVE
CENTER BLOCK
WETTED PARTS & OUTER PISTON
AIR VALVE
A = ALUMINUM
DIAPHRAGMS
BNS = BUNA-N (Red Dot) TXU = PTFE w/CONDUCTIVE
BUNA-N BACKUP
XBS = CONDUCTIVE BUNA-N
(Two Red Dots)
O-RINGS
VALVE SE AT
VALVE BALLS
VALVE BALL
BN = BUNA-N (Red Dot) TF = P TFE ( White)
VALVE SE AT
A = ALUMINUM S = STAINLESS STEEL
VALVE SE AT & MANIFOLD O-RING
BN = BUN A-N TF = P TFE ( White)
SPECIALT Y CODE
(if applicable)
CENTER BLOCK
AA = A LUMINUM
SPECIALTY CODES
0014 BSPT (side-ported inlet and discharge on 1” models) 0504 DIN Flange 0677 NPT, center-ported inlet and discharge 0678 BSPT, center-ported inlet and discharge 0695 19 mm (3/4”) NPT, center-ported discharge (inlet facing air inlet, discharge facing air exhaust) 0696 19 mm (3/4”) BSPT, center-ported discharge (inlet facing air inlet, discharge facing air exhaust) 0697 19 mm (3/4”) NPT, center-ported discharge (inlet facing air exhaust, discharge facing air inlet) 0698 19 mm (3/4”) BSPT, center-ported discharge (inlet facing air exhaust, discharge facing air inlet)
NOTE: Most elastomer materials use colored dots for identification.
NOTE: Not all models are available with all material options.
WILDEN PUMP & ENGINEERING, LLC 2 WIL-17011-E-01
Page 5
Section 3
HOW IT WORKS—PUMP
The Wilden diaphragm pump is an air-operated, positive displacement, self-priming pump. These drawings show flow pattern through the pump upon its initial stroke. It is assumed the pump has no fluid in it prior to its initial stroke.
FIGUR E 1 The air valve dire cts pre ssurized air to the back side of diaphragm A. The compressed air is applied directly to the liquid column separated by elastomeric diaphragms. The diaphragm ac ts as a separation membrane bet ween the compressed air and liquid; a balanced load removes mechanical stress from the diaphragm. The compressed air moves the diaphragm away from the center of the pump. The opposite diaphragm is pulled in by the shaft connected to the pressurized diaphragm. Diaphragm B is on its suction stroke; air behind the diaphragm has been forced out to the atmosphere through the exhaust port of the pump. The movement of diaphragm B toward the center of the pump creates a vacuum within chamber B. A tm ospheri c pressure forces fluid into the inlet manifold forcing the inlet valve ball off its seat. Liquid is free to move past the inlet valve ball and fill the liquid chamber (see shaded area).
HOW IT WORKS—AIR DISTRIBUTION SYSTEM
FIGURE 2 When the pressurized diaphragm, diaphragm A, reaches the limit of its discharge stroke, the air valve redirects pressurized air to the back side of diaphragm B. The pressurized air forces diaphragm B away from the center while pulling diaphragm A to the center. Diaphragm B is now on its discharge stroke. Diaphragm B forc es the inlet valve b all onto its se at due to the hydraulic forces developed in the liquid chamber and manifold of the pump. These same hydraulic forces lift the discharge valve ball off its seat, while the opposite discharge valve ball is forced onto its seat, forcing fluid to flow through the pump discharge. The movement of diaphragm A toward the center of the pump creates a vacuum within liquid chamber A. Atmos­pheric pressure forces fluid into the inlet manifold of the pump. The inlet valve ball is forced off its seat allowing the fluid being pumped to fill the liquid chamber.
FIGURE 3 At completion of the stroke, the air valve again redirects air to the back side of diaphragm A, which starts diaphragm B on its exhaust stroke. As the pump reaches its original star ting point, each diaphragm has gone through one exhaust and one discharge stroke. This constitutes one complete pumping cycle. The pump may take several cycles to completely prime depending on the conditions of the application.
The heart of the patented Pro-Flo® SHIFT Air Distribution System (ADS) is the air valve assembly. The air valve design incorporates an unbalanced spool with the small end of the spool being pressurized continuously while the large end of the spool is alternately pressurized, then exhausted to move the spool. The air valve spool directs pressurized air to one chamber while exhausting the other. The air forces the main shaft/diaphragm assembly to move to one side – discharging liquid on that side and pulling liquid in on the other side. When the shaft reaches the end of the stroke, the inner piston actuates the pilot spool, which controls the air to the large end of the air valve spool. The repositioning of the air valve spool routes the air to the other air chamber. The air control spool allows air to flow freely into the air chamber for the majority of each pump stroke, but it significantly restricts the flow of air into the air chamber when activated by the inner piston near the end of the each stroke.
WIL-17011-E-01 3 WILDEN PUMP & ENGINEERING, LLC
Page 6
Section 4
DIMENSIONAL DRAWINGS
GPS1 Metal
DIMENSIONS
ITEM METRIC (mm) STANDARD (inch)
A 208 8.2 B 28 1.1 C 130 5.1 D 198 7.8 E 224 8.8 F 41 1.6 G 126 5.0 H 216 8.5 J 354 14.0 K 131 5.2
L 30 1.2 M 137 5.4 N 109 4.3
P 84 3.3
R 102 4.0
S 8 0.3
T 203 8.0
U 142 5.6
V 112 4.4
LW0361 REV. A
GPS220 Metal
DIMENSIONS
ITEM METRIC (mm) STANDARD (inch)
A 361 14.2
B 36 1.4
C 163 6.4
D 254 10.0
E 287 11.3
F 56 2.2
G 417 16.4
H 71 2.8
J 140 5.5
K 155 6.1
L 206 8.1 M 173 6.8 N 104 4.1
P 127 5.0
R 10 0.4
LW0364 REV. A
WILDEN PUMP & ENGINEERING, LLC 4 WIL-17011-E-01
Page 7
DIMENSIONAL DRAWINGS
GPS220 Metal, Center-Ported
DIMENSIONS
ITEM METRIC (mm) STANDARD (inch)
A 422 16.6 B 36 1.4 C 163 6.4 D 254 10.0 E 287 11.3 F 33 1.3 G 417 16.4 H 71 2.8 J 140 5.5 K 155 6.1
L 206 8.1 M 173 6.8 N 104 4.1
P 127 5.0
R 10 0.4
LW0365 REV. A
GPS230 Stainless Steel
DIMENSIONS
ITEM METRIC (mm) STANDARD (inch)
A 373 14.7
B 69 2.7
C 195 7.6
D 287 11.3
E 340 13.4
F 343 13.5
G 71 2.8
H 417 16.4
J 71 2.8
K 140 5.5
L 188 7.4 M 206 8.1 N 173 6.8
P 104 4.1
R 127 5.0
S 10 0.4
T 203 8.0
DIN (mm) ANSI (inch)
U 85 DIA. 3.1 DIA.
V 115 DIA. 4.3 DIA. W 14 DIA. 0.6 DIA.
LW0366 REV. A
WIL-17011-E-01 5 WILDEN PUMP & ENGINEERING, LLC
Page 8
[8] [15] [23] [30] [38] [45] [53] [61]
[8] [15] [23] [30] [38] [45] [53] [61]
Section 5
PERFORMANCE
GPS1 METAL
RUBBER-FITTED
Ship Weight ............ Aluminum 6 kg (13 lb)
316 Stainless Steel 9 kg (20 lb) Alloy C 9.5 kg (21 lb)
Air Inlet .....................................6 mm (1/4”)
Inlet ......................................... 13 mm (1/2”)
Outlet ...................................... 13 mm (1/2”)
Suction Lift ....................... 5.9 m Dry (19.3’)
9.8 m Wet (32.3’)
Disp. per Stroke1 ............. 0.10 L (0.027 gal)
Max. Flow Rate .......... 60.2 lpm (15.9 gpm)
Max. Size Solids .................. 1.6 mm (1/16”)
1
Displacement per stroke was calculated at
4.8 bar (70 psig) air inlet pressure against a
2.1 bar (30 psig) head pressure.
Example: To pump 20.1 lpm (5.3 gpm) against a discharge head of 3.4 bar (50 psig) requires 4.1 bar (60 psig) and 7.7 Nm3/h (4.8 scfm) air consumption.
Caution: Do not exceed 8.6 bar (125 psig) air supply pressure.
V
4[7]
2 4 6 8 10 12 14 16
Flow rates indicated on chart were determined by pumping water.
For optimum life and performance, pumps should be specified so that daily operation parameters will fall in the center of the pump's performance curve.
8[14]
12[20]
16[27]
GPS1 METAL
PTFE-FITTED
Ship Weight ............ Aluminum 6 kg (13 lb)
316 Stainless Steel 9 kg (20 lb) Alloy C 9.5 kg (21 lb)
Air Inlet .....................................6 mm (1/4”)
Inlet ......................................... 13 mm (1/2”)
Outlet ...................................... 13 mm (1/2”)
Suction Lift ....................... 4.3 m Dry (14.2’)
9.7 m Wet (31.7’)
Disp. per Stroke1 ............. 0.10 L (0.026 gal)
Max. Flow Rate .......... 59.8 lpm (15.8 gpm)
Max. Size Solids .................. 1.6 mm (1/16”)
1
Displacement per stroke was calculated at
4.8 bar (70 psig) air inlet pressure against a
2.1 bar (30 psig) head pressure.
Example: To pump 17.4 lpm (4.6 gpm) against a discharge head of 2.1 bar (30 psig) requires 2.8 bar (40 psig) and 5.9 Nm3/h (3.5 scfm) air consumption.
Caution: Do not exceed 8.6 bar (125 psig) air supply pressure.
4[7]
8[14]
12[20]
16[27]
2 4 6 8 10 12 14 16
Flow rates indicated on chart were determined by pumping water.
For optimum life and performance, pumps should be specified so that daily operation parameters will fall in the center of the pump's performance curve.
WILDEN PUMP & ENGINEERING, LLC 6 WIL-17011-E-01
Page 9
PERFORMANCE
GPS220/GPS230 METAL
RUBBER-FITTED
Ship Weight ...........Aluminum 19 kg (41 lb)
Ductile Iron 29 kg (64 lb) 316 Stainless Steel 31 kg (68 lb)
Air Inlet ................................... 13 mm (1/2")
Inlet ............................................ 25 mm (1")
Outlet ......................................... 25 mm (1")
Suction Lift ....................... 6.9 m Dry (22.7')
9.0 m Wet (29.5')
Disp. Per Stroke1 ................... 0.30 L (0.08 gal)
Max. Flow Rate .............. 204 lpm (54 gpm)
Max. Size Solids .................... 6.4 mm (1/4")
1
Displacement per stroke was calculated at
4.8 bar (70 psig) air inlet pressure against a
2.1 bar (30 psig) head pressure.
Example: To pump 140 lpm (37 gpm) against a discharge pressure head of
2.8 bar (40 psig) requires 5.5 bar (80 psig) and 60 Nm3/h (38 scfm) air consumption. (See dot on chart.)
Caution: Do not exceed 8.6 bar (125 psig) air supply pressure.
Flow rates indicated on chart were determined by pumping water.
For optimum life and performance, pumps should be specified so that daily operation parameters will fall in the center of the pump's performance curve.
GPS220/GPS230 METAL
FULL-STROKE PTFE-FITTED
Ship Weight ...........Aluminum 19 kg (41 lb)
Ductile Iron 29 kg (64 lb) 316 Stainless Steel 31 kg (68 lb)
Air Inlet ................................... 13 mm (1/2")
Inlet ............................................ 25 mm (1")
Outlet ......................................... 25 mm (1")
Suction Lift ........................5.2 m Dry (17.0')
9.0 m Wet (29.5')
Disp. Per Stroke1 ................... 0.30 L (0.08 gal)
Max. Flow Rate .............. 197 lpm (52 gpm)
Max. Size Solids .................... 6.4 mm (1/4")
1
Displacement per stroke was calculated at
4.8 bar (70 psig) air inlet pressure against a
2.1 bar (30 psig) head pressure.
Example: To pump 83.3 lpm (22 gpm) against a discharge pressure head of
2.8 bar (40 psig) requires 4.1 bar (60 psig) and 36 Nm3/h (23 scfm) air consumption. (See dot on chart.)
Caution: Do not exceed 8.6 bar (125 psig) air supply pressure.
Flow rates indicated on chart were determined by pumping water.
For optimum life and performance, pumps should be specified so that daily operation parameters will fall in the center of the pump's performance curve.
WIL-17011-E-01 7 WILDEN PUMP & ENGINEERING, LLC
Page 10
SUCTION-LIFT CURVES
GPS1 METAL SUCTION-LIFT CAPABILITY
Suction-lift curves are calibrated for pumps operating at 305 m (1,000') above sea level. This chart is meant to be a guide only. There are many variables that can affect your pump's operating characteristics. The number of intake and discharge elbows, viscosity of pumping fluid, elevation (atmospheric pressure) and pipe friction loss all affect the amount of suction lift your pump will attain.
Traditional Rubber Diaphragms
PTFE Diaphragms
GPS220/GPS230 METAL SUCTION-LIFT CAPABILITY
Suction-lift curves are calibrated for pumps operating at 305 m (1,000') above sea level. This chart is meant to be a guide only. There are many variables that can affect your pump's operating characteristics. The number of intake and discharge elbows, viscosity of pumping fluid, elevation (atmospheric pressure) and pipe friction loss all affect the amount of suction lift your pump will attain.
WILDEN PUMP & ENGINEERING, LLC 8 WIL-17011-E-01
Page 11
Section 6
CSA-CERTIFIED PUMP SUGGESTED INSTALLATION
Prior to pump installation, ensure that the flow and suction lift requirements are within the pump model’s capabilities. Refer to the Section 5, Performance of the Engineering, Operation and Maintenance (EOM) Manual for specific flow and suction-lift capabilities.
Before installation confirm that the pump materials of construction are compatible with pumping application. Refer to the Wilden Chemical Resistance Guide for assistance with wetted path and elastomer options.
PIPING: The pump should be located so that the length and complexity of the suction and discharge piping is minimized. Unnecessary elbows, bends and fittings can increase friction losses and should be avoided.
Pipe sizes should be selected to keep friction losses within practical limits. The suction pipe diameter should be equivalent or larger than the diameter of the suction inlet on your Wilden pump. The suction hose must be non­collapsible, reinforced type as these pumps are capable of pulling a high vacuum. Discharge piping should also be the equivalent or larger than the diameter of the pump discharge to help reduce friction losses.
All piping should be supported independently of the pump. In addition, the piping should be correctly aligned with the inlet and discharge connection of the pump to avoid placing stress on the pump fittings. Flexible hose can be installed to aid in absorbing the forces created by the natural reciprocating action of the pump and will also assist in minimizing pump vibration.
GAS SUPPLY: The pump should have a supply line large enough (a 3/4” supply line is recommended for 1-1/2” and larger pumps) to supply the volume of air necessary to achieve the desired pumping rate. Gas pressure to the pump should be controlled by a pressure-regulating valve and should not exceed a maximum of 6.9 bar (100 psig). It is suggested that a needle valve be placed in the supply line to control the flow of gas to the pump. For best results, a 5μ (micron) filter should be installed before the gas inlet of the pump to eliminate the majority of compressed gas line contaminants.
TYPE OF GAS: Sweet gas is required for natural gas­powered pumps. Please consult the factory if considering using sour gas as levels of hydrogen sulfide (H2S) may cause unacceptable corrosion and chemical attack.
PUMP MOUNTING AND INSTALLATION: For simple installation and removal of the pump shut-off valves should be installed in the inlet and discharge plumbing.
If the pump is to be mounted in a fixed location, a mounting pad placed between the pump and the foundation will assist in minimizing pump vibration. If quick-closing valves are installed at any point in the discharge system, or if pulsation within a system becomes a problem, a surge suppressor should be installed to protect the pump, piping and gauges from surges and water hammer.
SOLIDS PASSAGE: All Wilden pumps are capable of passing solids. A strainer should be used at the inlet of the pump to ensure that the pump’s rated solids capabilities are not exceeded. Refer to the Section 5 of this EOM manual for specific solids-passage capabilities.
FLOODED SUCTION: Pumps in service with a positive suction head are most efficient when the inlet pressure is limited to 0.5–0.7 bar (7–10 psig). Premature diaphragm failure may occur if positive suction is 0.7 bar (10 psig) or higher.
SUCTION LIFT: When used in self-priming applications, it is critical that all fittings and connections are airtight or a reduction or loss of pump suction capability will result.
GAS OUTLET: All CSA-certified pumps are fitted with the single point exhaust option so that all exhaust gases are routed through the muffler plate exhaust port. The gas outlet must be recaptured or vented to a safe location in accordance with locally, nationally and/or industry recognized codes.
GROUNDING: Pumps and accessories must be electrically grounded to a proper grounding point to prevent an accumulation of electro-static charge when used in potentially explosive areas. CSA-certified pumps come with a grounding strap and are fitted with a grounding screw for the purpose of electrically grounding the pump. Periodic inspection of the ground connection should be performed to ensure the equipment is properly grounded. Refer to the Wilden CE Safety Supplement and Safety Manual for additional ATEX-certified pump considerations.
FUNCTIONAL TESTING:
1. Tighten all hardware prior to initial start-up. Refer to Section 7, Reassembly Hints & Tips in the EOM manual for torque specifications.
2. Prior to pump installation connect compressed gas line [do not exceed rated pressure of 6.9 bar (100 psig)] to gas inlet of pump to ensure that pump cycles consistently.
3. Cycle pump for 2-3 minutes.
4. After pump installation, check piping connections for leaks.
PUMP OPERATION:
1. To avoid damage to the pump new installations should be checked for any debris in tank or piping system.
2. Once installation is complete, pump operation can be started. Confirm the shut-off valves in the inlet and discharge plumbing are open. Do not exceed the pump’s maximum rated pressure of 6.9 bar (100 psig). A pressure regulating valve and needle valve can be used to adjust the speed of the pump.
3. Retighten all exposed fasteners after two (2) hours of operation. Refer to Section 7, Reassembly Hints & Tips in the EOM manual for torque specifications.
WIL-17011-E-01 9 WILDEN PUMP & ENGINEERING, LLC
Page 12
CSA-CERTIFIED PUMP SUGGESTED INSTALLATION
FOOTPAD
DISCHARGE
This illustration is a generic representation of an air-operated double-diaphragm pump.
EQUALIZER
SURGE DAMPENER
(OPTIONAL)
GAUGE
®
(OPTIONAL)
SHUT-OFF VALVE
GROUNDING
LOCATION
MUFFLER
FLEXIBLE
CONNECTION
SUCTION
EMERGENCY SHUT-DOWN PROCEDURE: In the case of an emergency situation, the pump should be stopped immediately. To stop the pump’s operation close the gas shut–off valve (user-supplied). A properly functioning valve will cut-off the gas supply, stopping the pump. The shut-off valve should be located far enough away from the pumping equipment such that it can be reached safely in an emergency situation.
In the event of pump or diaphragm failure, close shut-off valves at the inlet and discharge of pump to eliminate the possibility of medium leakage
In the event of a power failure, the gas shut-off valve should be closed, if restarting of the pump is not desirable once power is regained.
FLEXIBLE CONNECTION
NEEDLE VALVE
COMBINATION
FILTER & REGULATOR
AIR SHUT-OFF VALVE
Refer to the Wilden CE Safety Supplement, Safety Manual and EOM Manual for additional information.
PRIOR TO MAINTENANCE: Before any maintenance is performed, confirm pump is completely de-energized by shutting off the pump and disconnecting the gas supply line to the pump.
Refer to Section 7, Reassembly Hints & Tips and Section 8, Exploded View & Parts Listings in the EOM manual for maintenance and spare parts information.
WILDEN PUMP & ENGINEERING, LLC 10 WIL-17011-E-01
Page 13
CSA-CERTIFIED PUMP SUGGESTED OPERATION & MAINTENANCE
OPERATION: CSA -certified pumps are pre-lubricated, and do not require in-line lubrication. Additional lubrication will not damage the pump, however if the pump is heavily lubricated by an external source, the pump’s internal lubrication may be washed away. If the pump is then moved to a non-lubricated location, it may need to be disassembled and re-lubricated as described in the DISASSEMBLY/REASSEMBLY.
Pump discharge rate can be controlled by limiting the volume and/or pressure of the air supply to the pump. An air regulator is used to regulate air pressure. A needle valve is used to regulate volume. Pump discharge rate can also be controlled by throttling the pump discharge by partially closing a valve in the discharge line of the pump. This action increases friction loss which reduces flow rate. (See Section 5.) This is useful when the need exists to control the pump from a remote location. When the pump discharge pressure equals or exceeds the air supply pressure, the pump will stop; no bypass or pressure relief valve is needed, and pump damage will not occur. The pump has reached a “deadhead” situation and can be
restarted by reducing the fluid discharge pressure or increasing the air inlet pressure. CSA-certified pumps run on pressurized sweet gas and do not generate heat, therefore your process fluid temperature will not be affected.
MAINTENANCE AND INSPECTIONS: Since each application is unique, maintenance schedules may be different for every pump. Frequency of use, line pressure, viscosity and abrasiveness of process fluid all affect the parts life of a Wilden pump. Periodic inspections have been found to offer the best means for preventing unscheduled pump downtime. Personnel familiar with the pump’s construction and service should be informed of any abnormalities that are detected during operation.
RECORDS: When service is required, a record should be made of all necessary repairs and replacements. Over a period of time, such records can become a valuable tool for predicting and preventing future maintenance problems and unscheduled downtime. In addition, accurate records make it possible to identify pumps that are poorly suited to their applications.
TROUBLESHOOTING
Pump will not run or runs slowly.
1. Ensure that the gas inlet pressure is at least 0.4 bar (5 psig) above startup pressure and that the differential pressure (the difference between gas inlet and liquid discharge pressures) is not less than 0.7 bar (10 psig).
2. Check air inlet filter for debris (see SUGGESTED INSTALLATION).
3. Check for extreme gas leakage (blow by) that would indicate worn seals /bores in the gas valve, pilot spool and main shaft.
4. Disassemble pump and check for obstructions in the gas passageways or objects that would obstruct the movement of internal parts.
5. Check for sticking ball check valves. If material being pumped is not compatible with pump elastomers, swelling may occur. Replace ball check valves and seals with proper elastomers. Also, as the check valve balls wear out, they become smaller and can become stuck in the seats. In this case, replace balls and seats.
6. Check for broken inner pistons that will cause the gas valve spool to be unable to shift.
Pump runs, but little or no product flows.
1. Check for pump cavitation; slow pump speed down to allow thick material to flow into liquid chambers.
WIL-17011-E-01 11 WILDEN PUMP & ENGINEERING, LLC
2. Verify that vacuum required to lift liquid is not greater than the vapor pressure of the material being pumped (cavitation).
3. Check for sticking ball check valves. If material being pumped is not compatible with pump elastomers, swelling may occur. Replace ball check valves and seats with proper elastomers. Also, as the check valve balls wear out, they become smaller and can become stuck in the seats. In this case, replace balls and seats.
Pump gas valve freezes.
1. Check for excessive moisture in compressed gas. Alternatively, a coalescing filter may be used to remove the water from the compressed gas in some applications.
Air bubbles in pump discharge.
1. Check for ruptured diaphragm.
2. Check tightness of outer pistons (refer to torque specifications).
3. Check tightness of fasteners and integrity of O-rings and seals, especially at intake manifold.
4. Ensure pipe connections are airtight.
Product comes out air exhaust.
1. Check for diaphragm rupture.
2. Check tightness of outer pistons to shaft.
Page 14
Section 7
`
PUMP DISASSEMBLY
Tools Required:
• Appropriate-sized Wrench
• Adjustable Wrench
• Vise equipped with soft jaws (such as plywood, plastic or other suitable material)
CAUTION: Before any maintenance or repair is attempted, the compressed air line to the pump should be disconnected and all air pressure allowed to bleed from the pump. Disconnect all intake, discharge and air lines. Drain the pump by turning it upside down and allowing any fluid to flow into a suitable container. Be aware of any hazardous effects of contact with your process fluid.
NOTE: The model used for these instructions incorporates rubber diaphragms and balls. Models with PTFE diaphragms and balls are the same except where noted. Your specific pump model may vary from configuration shown; however, pump disassembly procedure will be the same.
Step 1
Please note alignment marks on center section. Use to properly align liquid chamber to center section.
WILDEN PUMP & ENGINEERING, LLC 12 WIL-17011-E-01
Step 2
Using a wrench, loosen the discharge manifold from the liquid chambers.
Step 3
Remove the discharge manifold to expose the valve balls, valve seats and valve seat O-rings.
Page 15
PUMP DISASSEMBLY
Step 4
Remove the discharge valve balls, seats and valve seat O-rings from the discharge manifold and liquid chamber, inspect for nicks, gouges, chemical attack or abrasive wear. NOTE: Replace worn parts with genuine Wilden part for reliable performance.
Step 5
Using a wrench, remove the inlet manifold.
Step 6
Remove the inlet valve balls, seats and valve seat O-rings from the liquid chamber and inlet manifold, inspect for nicks, gouges, chemical attack or abrasive wear.
Step 7
NOTE: This step is for PS1 pumps only.
Using an appropriate-sized wrench, remove the small clamp band that connects the manifold elbows to the tee section. Remove the tee section o-rings and inspect for signs of wear and/or chemical attack. Replace, if necessary.
WIL-17011-E-01 13 WILDEN PUMP & ENGINEERING, LLC
Step 8
Using a wrench, remove the liquid chambers from the center section.
Page 16
PUMP DISASSEMBLY
Step 9
The liquid chamber should be removed to expose the diaphragm and outer piston. Rotate center section and remove the opposite liquid chamber.
Step 10
Using two adjustable wrenches, remove diaphragm assembly from center section assembly.
Step 11
After loosening and removing the outer piston the diaphragm assembly can be disassembled.
Step 12
To remove the remaining diaphragm assembly from the shaft, secure shaft with soft jaws (a vise fitted with plywood or other suitable material) to ensure shaft is not nicked, scratched, or gouged. Using an adjustable wrench, remove diaphragm assembly from shaft. Inspect all parts for wear and replace with genuine Wilden parts if necessary.
WILDEN PUMP & ENGINEERING, LLC 14 WIL-17011-E-01
Step 13
Inspect diaphragms, outer and inner pistons for signs of wear. Replace with genuine Wilden parts if necessary.
Page 17
PUMP DISASSEMBLY
GROUNDING STRAP FOR CSA PUMPS
Figure 1 Figure 2
Canadian Standards Association (CSA) configured pumps must be electrically grounded using the grounding strap provided (Figure 1). Improper grounding can cause improper and dangerous operation. To properly attach the grounding strap to a CSA-configured pump, identify the designated grounding location on the muffler plate; using the provided self-tapping screw and grounding wire, thread the grounding screw through the grounding wire lug, into the muffler plate and tighten securely (Figure 2). Completion of the pump grounding procedure must be done in accordance with local codes, or in the absence of local codes, an industrial or nationally recognized code having jurisdiction over the specified installation.
WIL-17011-E-01 15 WILDEN PUMP & ENGINEERING, LLC
Page 18
AIR VALVE / CENTER SECTION DISASSEMBLY
Tools Required:
• 3/16” Hex-Head Wrench
7/32” Hex-Head
• Wrench
• Snap-Ring Pliers
• O-Ring Pick
CAUTION: Before any maintenance or repair is attempted, the compressed air line to the pump should be disconnected and all air pressure allowed to bleed from the pump. Disconnect all intake, discharge and air lines. Drain the pump by turning it upside down and allowing any fluid to flow into a suitable container. Be aware of hazardous effects of contact with your process fluid.
®
The Wilden Pro-Flo distribution system. Proprietary composite seals reduce the co efficient of friction and allow the Pro-Flo® SHIFT to run lube-free. The Pro-Flo® SHIFT air distribution system is designed to perform in on /off, non-freezing, non-stalling, tough duty applications.
SHIFT metal pumps utilize a revolutionary Pro-Flo® SHIFT air
Step 1
Using a 3/16” hex head wrench, loosen the air valve bolts.
WILDEN PUMP & ENGINEERING, LLC 16 WIL-17011-E-01
Step 2
Remove the air valve and muffler plate from the center section.
Step 3
Remove the air valve gasket and inspet for nicks, gouges and chemical attack. Replace if necessary with genuine Wilden parts. NOTE: When installing the air valve gasket onto the center section assembly, position gasket with the grooved side facing away from the center section.
Page 19
AIR VALVE / CENTER SECTION DISASSEMBLY
Step 4
Remove muffler plate gasket and inspect. Replace, if necessary.
Step 5
Remove air valve end cap to expose air valve spool. NOTE: The end cap cannot be removed until removing air valve bolts.
Step 6
Remove air valve spool from air valve body by threading one air valve bolt into the end of the spool and gently sliding the spool out of the air valve body. Inspect seals for signs of wear and replace entire assembly if necessary. Use caution when handling air valve spool to prevent damaging seals. NOTE: Seals should not be removed from assembly. Seals are not sold separately.
Step 7
Remove pilot spool retaining snap­ring on both sides of center section with snap-ring pliers.
WIL-17011-E-01 17 WILDEN PUMP & ENGINEERING, LLC
Step 8
Remove pilot spool assembly from center section.
Step 9
Using an O-ring pick, gently remove the pilot spool retaining O-ring from the opposite side of the notched end of the spool. Gently remove the pilot spool from pilot spool sleeve and inspect for nicks, gouges and other signs of wear. Replace pilot spool assembly or outer sleeve O-rings if necessary. During re-assembly never insert the pilot spool into the sleeve with the “notched” end side first, this end incorporates the urethane O-ring and will be damaged as it slides over the ports cut in the pilot spool sleeve.
Page 20
AIR VALVE / CENTER SECTION DISASSEMBLY
Step 10
Check center section shaft seals for signs of wear. If necessary, remove the shaft seals with an O-ring pick and replace.
SINGLE-POINT EXHAUST PRO-FLO® SHIFT
Standard Single-Point Exhaust
Step 1
Remove pilot exhaust muffler in pilot bleed port located at the front of the center block. Install 1/4" NPT pipe plug (00-7010-08) into bleed port.
Step 2
Next, install an optional single-point exhaust gasket (01-2621-52). The single-point air valve gasket can be purchased as a spare part or included with the purchase of a new Pro-Flo
®
SHIFT pump.
WILDEN PUMP & ENGINEERING, LLC 18 WIL-17011-E-01
Page 21
REASSEMBLY HINTS & TIPS
RE A S SE M B LY:
Upon performing applicable maintenance to the air distrib ution system, t he pump can now be re assembled . Please refer to the disassembly instructions for photos and parts placement. To reassemble the pump, follow the disassembly instructions in reverse order. The air distribution system needs to be assembled first, then the diaphragms and finally the wetted path. Please find the applicable torque specifications on this page. The following tips will assist in the assembly process.
• Lubricate air valve bore, center section shaft and pilot spool bore with NLGI grade 2 white EP bearing grease or equivalent.
• Clean the inside of the center section shaft bore to ensure no damage is done to new shaft seals.
• A small amount of NLGI grade 2 white EP bearing grease can be applied to the muffler and air valve gaskets to lubricate gaskets during assembly.
• Make sure that the exhaust port on the muffler plate is centered between the two exhaust ports on the center section.
• Stainless bolts should be lubed to reduce the possibility of seizing during tightening.
• Use a mallet to tamp lightly on the large clamp bands to seat the diaphragm before tightening.
PRO-FLO® SHIFT MAXIMUM TORQUE SPECIFICATIONS
Description of Part Torque
Air Valve 11.3 N•m (100 in-lb)
Outer Piston 14.1 N•m (125 in-lb)
Small Clamp Band 1.7 N•m (15 in-lb)
Large Clamp Band (Rubber/ TPE-F itted) 9.0 N•m (80 in-lb)
Large Clamp Band (PT FE-F itted) 13.6 N•m (120 in-lb)
Vert ical Bolts 14.1 N•m (125 in-lb)
Figure A
SHA FT SE AL
SHAFT SEAL INSTALLATION:
PRE-INSTALLATION
• Once all of the old seals have been removed, the inside of the bushing should be cleaned to ensure no debris is left that may cause premature damage to the new seals.
INSTALLATION
The following tools can be used to aid in the installation of the new seals:
Needle-Nose Pliers Phillips Screwdriver Electrical Tape
• Wrap electrical tape around each leg of the needle-nose pliers (heat shrink tubing may also be used). This is done to prevent damaging the inside surface of the new seal.
• With a new seal in hand, place the two legs of the needle-nose pliers inside the seal ring. (See Figure A.)
• Open the pliers as wide as the seal diameter will allow, then with two fingers pull down on the top portion of the seal to form a kidney shape. (See Figure B.)
• Lightly clamp the pliers together to hold the seal into the kidney shape. Be sure to pull the seal into as tight of a kidney shape as possible, this will allow the seal to travel down the bushing bore easier.
• With the seal clamped in the pliers, insert the seal into the bushing bore and position the bottom of the seal into the correct groove. Once the bottom of the seal is seated in the groove, release the clamp pressure on the pliers. This will allow the seal to partially snap back to its original shape.
• After the pliers are removed, you will notice a slight bump in the seal shape. Before the seal can be properly resized, the bump in the seal should be removed as much as possible. This can be done with either the Phillips screwdriver or your finger. With either the side of the screwdriver or your finger, apply light pressure to the peak of the bump. This pressure will cause the bump to be almost completely eliminated.
• Lubricate the edge of the shaft with white EP bearing grease.
• Slowly insert the center shaft with a rotating motion. This will complete the resizing of the seal.
• Perform these steps for the remaining seals.
Figure B
NEEDLE-NOSE
PLIERS
NLGI grade 2
TAPE
SHA FT SE AL
WIL-17011-E-01 19 WILDEN PUMP & ENGINEERING, LLC
TAPE
Page 22
Section 8
`
GPS1 METAL
EXPLODED VIEW & PARTS LISTING
EXPLODED VIEW
PTFE-FITTED
LWO482 REV. B
METAL ADS
ALL CIRCLED PART IDENTIFIERS ARE INCLUDED IN REPAIR KITS
WILDEN PUMP & ENGINEERING, LLC 20 WIL-17011-E-01
Page 23
EXPLODED VIEW & PARTS LISTING
GPS1 METAL
Item
Description Qty.
GPS1/AAAAA
P/N
AIR DISTRIBUTION COMPONENTS
1 Pro-Flo X® Air Valve Assembly
2 End Cap 1 01-2340-01
3 O-Ring (-126), End Cap (Ø1.362 x Ø.103) 1 01-2395-52 4 Gasket, Air Valve, Pro-Flo X 5 Gasket, Muffler Plate, Pro-Flo X
6 Muffler Plate, Pro-Flo X 7 Screw, SHC, Air Valve (1/4"-20 x 3") 4 01-6001-03 8 Center Block Assembly, Pro-Flo Shift
9 Pilot Sleeve Assembly 1 01-3880-99 10 O-Ring (-009), Pilot Spool Retaining (Ø.208" x .070") 2 04-2650-49-700 11 Shaft Seal 2 01-3220-55
12 Screw, 10-32 x .50 Self-Tapping Grounding 1 04-6345-08 13 Retaining Ring 1 00-2650-03 14 Grounding Strap, CSA 1 01-8303-99 15 Plug, Pipe, 1/4" MNPT 1 00-7010-03
1
®
®
®
™ 2
1 01-2030-01
1 01-2621-52 1 01-3502-52
1 01-3185-01
1 01-3139-01
WETTED PATH COMPONENTS
16 Liquid Chamber 2 01-5000-01 01-5000-03 17 Manifold Tee Section 2 01-5160-01 01-5160-03 18 Inlet Manifold Elbow 2 01-5220-01 01-5220-03 19 Discharge Manifold Elbow 2 01-5230-01 01-5230-03 20 RHSN Bolt, Liquid Chamber (1/4"-20 x 7-1/2") 4 01-6080-03 21 Washer, Flat (Ø.281 x Ø.625 x .065) 4 01-6730-03 22 Large Clamp Band Assembly 4 01-7300-03 23 RHSN Bolt, Large Clamp Band (1/4"-20 x 2-1/4") 4 01-6070-03 24 Hex Nut (1/4"-20) 8 04-6400-03 25 Small Clamp Band Assembly 8 01-7100-03 26 Screw, HHC (#10-24 x 1") 8 01-6101-03 27 Hex Nut (#10-24) 8 01-6400-03
VALVE BALLS/VALVE SEATS/VALVE O-RINGS
28 Ball, Valve 4 01-1080-52
Ball, Valve, PTFE Fitted 4 01-1080-55 29 Seat, Valve 4 01-1120-01 01-1120-03 30 O-Ring (-119), Valve Seat (Ø.924 x Ø.103) 4 00-1260-52
O-Ring (-119), Valve Seat (Ø.924 x Ø.103) PTFE Fitted 4 01-1200-55 31 O-Ring, Manifold (-120), (Ø.987 x Ø.103) 4 01-1300-52
O-Ring, Manifold (-120), (Ø.987 x Ø.103) PTFE Fitted 4 01-1300-55
RUBBER/PTFE COMPONENTS
32 Shaft 1 01-3810-03 33 Stud, Shaft (5/16"-18 x 1-3/8") 2 01-6150-03 34 Spring, Disc (Ø.331 x Ø.512) 2 01-6802-08 35 Inner Piston 2 01-3711-08
36 Diaphragm, Primary 2 01-1010-52
Diaphragm, Primary 2 01-1010-86
Diaphragm, Primary, PTFE Fitted 2 01-1010-55 37 Diaphragm, Backup, PTFE Fitted 2 01-1060-86
38 Outer Piston 2 01-4570-01 01-4570-03
1
Air Valve Assembly includes items 2 and 3.
2
Center Section Assembly includes item 11.
All boldface items are primary wear items.
GPS1/SSAAA
PARTS LISTING
P/N
LW0483 REV. B
WIL-17011-E-01 21 WILDEN PUMP & ENGINEERING, LLC
Page 24
EXPLODED VIEW & PARTS LISTING
GPS220/GPS230 METAL
EXPLODED VIEW
PTFE-FITTED
STAINLESS STEEL FLANGED
LWO484 REV. B
METAL ADS
WILDEN PUMP & ENGINEERING, LLC 22 WIL-17011-E-01
Page 25
EXPLODED VIEW & PARTS LISTING
GPS220/GPS230 METAL
Item
1 Pro-Flo X® Air Valve Assembly 2 O-Ring, End Cap (-126, Ø1.362 x Ø.103) 2 01-2395-52
3 End Cap 2 01-2340-01 4 Screw, SHC, Air Valve (1/4"-20 x 3") 4 01-6001-03 5 Muffler Plate, Pro-Flo X
6 Gasket, Muffler Plate, Pro-Flo X 7 Gasket, Air Valve, Pro-Flo X
8 Center Section Assembly, Pro-Flo SHIFT
9 Pilot Sleeve Assembly 1 02-3880-99 10 Pilot Spool Retaining O-Ring (-009. Ø.208 x Ø.070) 1 04-2650-49-700 11 Shaft Seal 2 02-3210-55-225
12 Retaining Ring 1 00-2650-03 13 Grounding Screw, (10-32 x 1/2") Self-Tapping 1 04-6345-08 14 Grounding Strap, CSA 1 01-8303-99 15 Plug, Pipe, 1/4" MNPT 1 00-7010-03
Description Qty.
AIR DISTRIBUTION COMPONENTS
1
®
®
®
2
GPS220/230/AAAAA
P/N
1 02-2030-01
1 02-3185-01
1 02-3502-52 1 02-2621-52
1 02-3138-01
WETTED PATH COMPONENTS
16 Liquid Chamber 2 02-5015-01 02-5015-03 17 Inlet Manifold, Side Ported, 1" NPT 1 02-5095-01 02-5095-03
Inlet Manifold, Side Ported, 1" BSPT 1 02-5096-01 02-5096-03 Inlet Manifold, Center Ported, 1" NPT 1 02-5095-01-677 02-5095-03-677 Inlet Manifold, Center Ported, 1" BSPT 1 02-5096-01-678 02-5096-03-678 Inlet Manifold, ANSI Flange 1 02-5090-03 Inlet Manifold, DIN Flange 1 02-5091-03
18 Discharge Manifold, Side Ported, 1" NPT 1 02-5035-01 02-5035-03
Discharge Manifold, Side Ported, 1" BSPT 1 02-5036-01 02-5036-03 Discharge Manifold, Center Ported, 3/4" NPT 1 02-5035-01-697 02-5035-03-697 Discharge Manifold, Center Ported, 3/4" BSPT 1 02-5036-01-698 02-5036-03-698 Discharge Manifold, Center Ported, 1" NPT 1 02-5035-01-677 02-5035-03-677 Discharge Manifold, Center Ported, 1" BSPT 1 02-5036-01-678 02-5036-03-678 Discharge Manifold, ANSI Flange 1 02-5030-03
Discharge Manifold, DIN Flange 1 02-5031-03 19 Screw, HHC, 5/16"-18 x 1" 32 08-6180-03-42 20 Washer, 5/16" 32 02-6731-03 21 Pipe Plug, 1" NPT 2 02-7010-01 02-7010-03
Pipe Plug, 1" BSPT 2 02-7011-01 02-7011-03
VALVE BALLS/VALVE SEATS/VALVE O-RINGS/MANIFOLD O-RING
22 Ball, Valve 4 02-1085-52
Ball, Valve, PTFE Fitted 4 02-1085-55 23 O-ring, Manifold (-229, Ø2.359 x Ø.139) 4 70-1280-52
O-ring, Manifold (-229, Ø2.359 x Ø.139) PTFE Fitted 4 70-1280-55 24 Valve Seat 4 02-1125-01 02-1125-03
O-ring, Valve Seat (-224, Ø1.734 x Ø.139) 4 02-1205-52
O-ring, Valve Seat (-224, Ø1.734 x Ø.139) PTFE Fitted 4 02-1205-55
25
RUBBER/PTFE COMPONENTS
26 Shaft 1 02-3810-03
Shaft, PTFE Fitted 1 02-3840-03 27 Stud, 3/8"-16 x 1 1/4" 2 02-6150-08 28 Disc Spring 2 02-6802-08 29 Inner Piston 2 02-3701-01
Inner Piston, PTFE Fitted 2 02-3751-01
30 Diaphragm, Primary 2 02-1010-52
Diaphragm, Primary 2 02-1010-86
Diaphragm, Primary, PTFE Fitted 2 02-1010-55 31 Diaphragm, Back-Up, PTFE Fitted 2 02-1060-86
32 Outer Piston 2 02-4550-01 02-4550-03
Outer Piston, PTFE Fitted
2
02-4601-01 02-4600-03
GPS220/230/SSAAA
P/N
LW0485 REV. B
PARTS LISTING
*Refer to Elastomer Options in Section 9.
1
Air Valve Assembly includes
item numbers 2 and 3.
2
Center Section Assembly
includes items 9, 10, 11 and 12.
All boldface items are primary wear items.
WIL-17011-E-01 23 WILDEN PUMP & ENGINEERING, LLC
Page 26
NOTES
Page 27
WARRANTY
Each and every product manufactured by Wilden Pump and Engineering, LLC is built to meet the highest standards of quality. Every pump is functionally tested to insure integrity of operation.
Wilden Pump and Engineering, LLC warrants that pumps, accessories and parts manufactured or supplied by it to be free from defects in material and workmanship for a period of five (5) years from date of installation or six (6) years from date of manufacture, whichever comes first. Failure due to normal wear, misapplication, or abuse is, of course, excluded from this warranty.
Since the use of Wilden pumps and parts is beyond our control, we cannot guarantee the suitability of any pump or part for a particular application and Wilden Pump and Engineering, LLC shall not be liable for any consequential damage or expense arising from the use or misuse of its products on any application. Responsibility is limited solely to replacement or repair of defective Wilden pumps and parts.
All decisions as to the cause of failure are the sole determination of Wilden Pump and Engineering, LLC.
Prior approval must be obtained from Wilden for return of any items for warranty consideration and must be accompanied by the appropriate MSDS for the product(s) involved. A Return Goods Tag, obtained from an authorized Wilden distributor, must be included with the items which must be shipped freight prepaid.
The foregoing warranty is exclusive and in lieu of all other warranties expressed or implied (whether written or oral) including all implied warranties of merchantability and fitness for any particular purpose. No distributor or other person is authorized to assume any liability or obligation for Wilden Pump and Engineering, LLC other than expressly provided herein.
PLEASE PRINT OR TYPE AND FAX TO WILDEN
PUMP INFORMATION
Item # Serial #
Company Where Purchased
YOUR INFORMATION
Company Name
Industry
Name Title
Street Address
City State Postal Code Country
Telephone Fax E-mail Web Address
Number of pumps in facility? Number of Wilden pumps?
Types of pumps in facility (check all that apply): Diaphragm
Media being pumped?
Other
Centrifugal
Gear
Submersible
Lobe
How did you hear of Wilden Pump?
Other
Trade Journal
Trade Show
Internet/ E-mail
Distributor
ONCE COMPLETE, FAX TO (909) 783-3440
OR GO TO PSGDOVER.COM > WILDEN > SUPPORT TO COMPLETE THE WARRANTY REGISTRATION ONLINE
NOTE: WARRANTY VOID IF PAGE IS NOT FAXED TO WILDEN OR SUBMIT TED ONLINE VIA THE PSGDOVER.COM WEBSITE
WILDEN PUMP & ENGINEERING, LLC
Page 28
PSG
22069 Van Buren St., Grand Terrace, CA 92313-5607
P: +1 (909) 422-1730
• F: +1 (909) 783-3440
wildenpump.com
Where Innovation Flows
PSG® reserves the right to modify the information and illustrations contained in this document without prior notice. This is a non-contractual document. 11-2018
Authorized PSG Representative:
Copyrigh t ©2018, PS G®, A Dover Compa ny
WIL-17011-E-01
REPLACE S WIL-17 010 -E- 04
Loading...