Dough Pro DP1300 Operation Manual

NSF-8
Congratulations!
2/10
Your selection of the Doughpro DP1300 is a sound business decision. Doughpro equipment is a result of the highest quality engineering and time-tested design. Your machine, combined with Doughpro’s reputation of innovation in dough press equipment manufacturing, insures the continuing capability of delivering the best-decorated product possible.
This manual describes installation, operation, and maintenance procedures for your new model DP1300.
Your model DP1300 machine will have a long trouble-free life. Read this manual carefully and keep it with your machine; it’s your key to proper operation and lasting service.
Installation
DOMESTIC
Use a separate 15 amp AC circuit. Only industrial extension cords with proper wire size should be used; size 16/3 wire for distance up to 25 feet, and size 14/3 for distance up to 50 feet.
INTERNATIONAL
Use a designated 16 amp AC circuit. Only industrial extension cords with proper wire size (2.5 sq. mm) shall be used.
Make sure there is a proper electrical wall outlet located within reach of the cord and plug attached to the press. Then place the press in an area which allows for “swing clearance” of the lower platen plus vertical and horizontal clearance of the press itself.
Limited Machine Warranty
Doughpro warrants this dough press machine, when operated under normal
conditions, to be free from manufacturing defects in material and workmanship for a period of one year on parts and labor from the invoice date.
This warranty will be effective only when Doughpro authorizes the original purchaser to return the product to the factory in South Gate, California freight prepaid and only when the product, upon examination, has proven to be defective.
This warranty does not apply to any machine that has been subjected to misuse, negligence or accident.
Doughpro shall not be liable for the injury, loss or damage, direct or consequential, arising out of the use or the inability to use the product.
No claim of any kind shall be greater in amount than the sale price of the product or part to which claim is made.
This is the sole warranty given by the company, it is in lieu of any other warranties, expressed or implied, in law or in fact, including the warranties of merchantability and fitness for a particular use, and is accepted such by the purchaser in taking delivery of this product.
Specifications
Electrical: 120V/50-60Hz/1450W/12.5Amps/AC Also available; specify when ordering: 240V/50-60Hz/1450W/6.5Amps
Includes 72” cord and NEMA approved plug.
Shipping Weight: 200lbs. (91kg.) – DP1300 280 lbs. (127 kgs.) – DP1400C
Safety Summary
WARNING
In case of power cord damage, do not attempt to repair or replace the power cord. Contact the manufacturer or the local distributor.
-1- DP1300 2/04
2/10
WARNING
Avoid touching hot surfaces while operating the machine.
CAUTION
During normal operation, the base of the machine must be installed or placed above the wall socket.
CAUTION
When servicing or cleaning the machine, make sure that the power cord is removed from the wall socket.
Operation Timer/Temperature Control
Fig. A
Solid State Controller
This controller has three (3) control features:
1. Temperature – May be set from 100°-425°F (38°-163°C)
2. Time – Time may be set from 1 second to 10 minutes.
3. Counter – Cycle counter counts the number of applications from 1 to 9999 (see additional Notes – Counter).
4. “2Lower” (Fig. A) Refers to models using upper and lower heated surfaces.
Controller Operation
1. Viewing the Modes of Operation:
-2- DP1300 2/04
4. Resetting the Counter
PRESSING DOUGH: For best results, your dough should be proofed before pressing, but it will also press directly out of your refrigerator.
Flour is not required to press a crust and should not be dusted on any part of the machine.
D1400C Cabinet & Compressor
• To view the set points of temperature, timer and counter, press MODE button to view the desired mode of operation.
2. Changing Temperature:
• Press MODE button until temperature is displayed.
• Press and hold SET button while pressing the UP () and DOWN () arrow buttons to desired temperature setting.
3. Changing Time:
• Press MODE button until time is displayed.
• Press and hold SET button while pressing the UP () and DOWN () arrow buttons to desired timer setting.
The DISENGAGE switch may be pressed anytime during a cycle, and the cycle will stop immediately, and the timer will reset.
Press MODE button until the counter is displayed.
• To Reset the Counter (# of Cycles), simultaneously push UP () or DOWN (↓) arrow buttons (approx. 5 seconds).
1. After connecting the air hose line from the compressor to the press, plug it into the properly rated electrical outlet for your press and air compressor cabinet. Verify the electrical requirements against the nameplate on the
Loading...