DOUG FLEENOR DESIGN, Inc
Models 221E-WALL - 621E-WALL DMX512 Combine Units
Safety Notice:
There are no user serviceable parts in the Model 221E-WALL - 621E-WALL series. Refer any service needs
to a qualified service technician.
Description:
All inputs are isolated from the output by optical couplers. Every input has its own power supply and line
receiver. Indic ators on each input dis play signal status. A ‘Mimic 1' indicator displays the relative level of
channel 1.
This series of combiners is designed to be mounted on any flat surface. Signal wires are connected to the
unit using pluggable terminal block connectors.
This series of combine units allows m ultiple control consoles to be used to operate one s et of dimmers,
moving lights, etc.
Connections:
Line Cord. The combiners are fitted with a non-detachable line cord with a male parallel blade connection.
The combiners are designed to work on any voltage between 100 and 120 volts 50/60 Hz, or from 220 - 240
volts. 50/60 Hz. Alternate power cords ar e availa ble to adapt to local power outlets. If a choice of line
voltages are available, selecting the lower voltage will allow the splitter to run cooler.
DMX Inputs. DMX input signals are applied to the DMX IN terminal block connectors labeled A - F.
DMX Output. The DMX output signal is available on the DMX OUT terminal block connector.
Termination. For maximum reliability each DMX512 control run needs to be terminate d . A l l i nputs to the
combiner are autom atically terminated. The output needs to be terminate d at th e end of its control run.
Sometimes termination is built into the receiver. In other cases a terminator should be plugged into the feedthrough connector of the last device.
Indicators:
Power Indicator. The red POWER LED will illuminate when power is applied to the combine unit.
Mimic 1 Indicator. The green ‘Mimic 1' indicator dims to a level representative of the level of channel one.
Signal Indicators. The green signal indicators (A - F ) will illuminate when a valid DMX signal is being
received on the associated input.
Specifications:
Baud rate: 250 Kilobaud
Input circuit: EIA-485 receiver protected by two self resetting fuses
Input signal: 0.5 volts minimum, 12 volts maximum
Output circuit: "Slew rate limited" EIA-485 driver protected by two 1/10 amp fuses
Output signal: EIA-485 driver yields an approximate 3 volt signal into 120 Ohms
Connectors: 3 conductor pluggable terminal blocks
Isolation: 2500 volt optical coupler, 5000 volt split bobbin transformer
Power input: 100 - 120 volts or 220 - 240 volts, 50/60 hertz, 0.1 amp (24 watts)
Color: Silver hammertone
Size & Weight: 10.5" deep, 2.0" high, 8.5" wide, 4.9 pounds
120 ohm input terminator protected by a self resetting fuse
Four transorb diodes: two on +Data, two on -Data
Input can withstand up to 240 volts without damage, transients up to 5KV
(Slew rate limited outputs reduce the errors caused by unterminated lines)
Outputs can withstand up to 12 volts without damage, transients up to 5KV
Doc# manual 621E-WALL.wpd
Doug Fleenor Design, Inc.
396 Corbett Canyon Road
Arroyo Grande, CA 93420
(805) 481-9599 voice and FAX
(888) 4-DMX512 toll free
web site: http://www.dfd.com