Ideal for high IO applications with the simplicity of an iSCSI SAN
Built in Redundancy
•
RAID 0, 1, 3, 5, 6, 10, 50
• Redundant, hot swap components
• AssuredSnap™ - Snapshot capability
• AssuredCopy™ - Additional data protection with
full volume copies
• Built-in schedule capability
Scalability and Performance
•
Dual or single RAID controller or JBOD
• Utilizes existing Ethernet network infrastructures
• 1.7TB base capacity that scales to 192TB
(utilizing 2TB SATA drives)
• OS Support - Windows, Linux, SuSE, Solaris
Easy Set-up and Management
Unified LUN architecture streamlines
•
configuration
• RAIDar 2.0 full featured management interface
Environmentally Responsible / Lower TCO
EcoStor™ - Economically and environmentally
•
sound technologies
- SimulCache™ - Low latency cache mirroring
- Battery-free cache backup
- DC power option
- 1 terabyte energy saving drives
• RoHS-5 and WEEE compliant
2 3 3 2
•
•
•
•
•
•
•
S P E C I F I C A T I O N S H E E T
•
•
•
•
Th e 2 332 fr om Do t Hill Sy ste ms se r ve s th e g ro win g i SC SI SAN
•
•
•
ma rk et all ow ing cu stome rs to eas il y c rea te their ow n E the rn et-
•
•
•
ba se d stor ag e ar ea ne two rk s. The po we r fu l 2332 st orage sy s-
•
•
•
te ms are sc al abl e, hi ghl y r el iab le , h igh -p erf orm an ce, an d e as y to
•
•
se t u p a nd man ag e. W it h i ts hig h p erf orman ce and hi gh ca pac it y,
•
•
•
Do t H ill 23 32 st ora ge sy ste ms are us ed fo r virtu al ize d s to rag e,
•
•
•
fi le syste ms , Sh ar e P oin t, MS Excha ng e, M S S QL , j ust to na me a
•
•
•
fe w a pplic at ion s.
•
•
•
•
•
Th e 2 332 fe at ure s a 12 -dr iv e a rra y h ou sed in a 2 ra cku ni t ( 2U)
•
•
•
en cl osu re pr ovi di ng dua l 1 Gb iSC SI in ter fac es pe r cont rolle r t o
•
•
•
3. 5- inc h S AS , SATA , o r s oli d s tate d ri ves . U p t o s eve n J BO D
•
•
ex pa nsi on un its ca n b e e asi ly added .
•
•
•
•
•
•
Ec o- fri endly Ec oSt or
•
•
•
Th e 2 332 us es su per ca pa cit or s inst ea d of RA ID ca che ba tteri es ,
•
•
pr ov idi ng in fin it e cach e b ack up du rin g a po wer lo ss wh ile be in g
•
•
•
en vi ron me nta ll y f rie nd ly. Us ing su per ca pa cit or s e lim in ate s t he
•
•
•
ne ed for ba tt ery ma int en anc e, re duc in g the t ot al cos t o f o wner-
•
•
•
sh ip .
•
•
•
•
•
Ad va nce d D ata Pr ote ct ion Pr ovi de s In st ant Re cov er y
•
•
•
Is yo ur dat a e ss ent ia l t o yo ur bu sin es s o per at ion s? Th en it m ak es
•
•
•
se ns e to ad d d at a prot ec tio n o ption s - As sured Sn ap™ an d
•
•
As su red Co py™ . A ss ure dS nap ™ p ro vid es th e 23 32 st ora ge ar ray
•
•
•
wi th volum e s nap sh ot cap ab ili ty al low in g p oin t- in- ti me cop ie s t hat
•
•
•
ca n b e u sed to ma ximiz e b usi ne ss con ti nui ty. As su red Co py™ cr e-
•
•
•
at es a f ull vo lu me cop y w hic h p ro tec ts ag ain st di sk f ai lures . D ot
•
•
Hi ll ’s ‘s et and fo rg et’ sc hedul er cap ab ility gi ves st or age ad mi nis -
•
•
•
tr at ors pe ac e of mi nd . M ake su re you ha ve the ba ck ups th at
•
•
•
en ab le qui ck poi nt -in-t im e re co ver y.
•
ª
•
Ea sy Man ag eme nt Too l wi th W iz ard s
Do t H ill st or age sy st ems ar e e asy to co nf igu re an d ma na ge wit h
im pr ove d R AI Dar 2. 0, the in tu iti ve Web Bas ed Inter fac e ( WBI)
wh ic h prov id es s to rage s et up and mo ni tor in g with ou t th e n ee d f or
ho st based so ftw ar e. RAI Da r 2 .0 con ta ins in stall at ion an d c onf ig ur at ion wi za rds to ma ke man ag eme nt ea sy.
TM
spec
2332 iSCSI

2332 Specifications
GE NE RAL
Product Family
Product Type
Chassis Configuration
Disk Architecture
• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • •
2002 Ser ies
RAID, JBOD
2U
3Gb SAS/ 3Gb SATA-II
Max Drives per Chassis 12 drives
Total Capacity
Total Disks
Mounting Options
Max Number of Chassis
Max Capacity per Chassis
Data Management Services (DMS)
1.7TB/192TB (with expansi on trays)
96
19” Rack , Telco Ra ck, Rack tray
8 (1 RAID and 7 JBOD)
24TB (2T B SATA-II drives)
AssuredSnap
™, AssuredCopy™
PR OT OCO LS AN D STA ND ARD S .. .. ..... .. ... .. ..... .. ... .. .. ..
iSCSI (IETF)
ICMP (RF C 792, 950, 1256)
IP (RFC, 894, 1092) SCSI-2 a nd SCSI-3
TCP (RFC 793) FC Chann el
HO ST S
Initiators
Interface Type
External Ports
• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • •
All iSCS I complia nt initi ators
RJ-45
2/4 iSCS I (Gigabit Ethernet)
Single/Dual Contr oller
DR IV ES
Max Number of Drives
3.5” Drive Options
• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • •
96
SAS 146G B 15K RPM
SAS 300G B 15K RPM
SAS 450G B 15K RPM
SATA-II 500GB 7200 RPM
SATA-II 750GB 7200 RPM
SATA-II 1TB 7200 RPM
SATA-II 2TB 5400 RPM
RA ID
• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • •
Levels Supported
RAID Type
Cache Memory
Cache Backup
Virtual disks per System
Volumes per virtual disk
Volumes per System
Mirrored Cache
Super Capacitor Cache Backup
Cache Backup to Flash
MA NA GEM EN T
Interface Types
• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • •
Protocols Supported
Management Consoles
Management Software
PO WE R REQU IR EME NT S - AC
Input Power Requirements
Max Input Power
Heat Dissipation
PO WE R REQU IR EME NT S - DC
Voltage -39 to -72VDC, -48/-60V nominal
32, 80GB SSD
Non-RAID, 0,1,3,5 ,6,10, a nd 50
Hardware
1GB per controller
Battery-free pro tection with super capacitors
32
128
256
Yes - SimulCache
™
Yes
Yes - Non-volatile
Mini DB9 RS232, 10/ 100 Ethe rnet
SNMP, SSL, SSH, SMTP
WEB GUI, CLI
RAIDar 2 .0
• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • •
100–240VAC, 50/60 Hz, 4.5-1.9A
475W max imum continuous
1622 BTU /hour
• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • •
Max Input Power 500W maximum continuous
Heat Dissipation 1706 BTU/hour
TE MP ERAT UR E AN D H UM IDI TY RA NGE S . .. ... .. .. ... .. ....
Operating Temperature
41°F to 104°F (5°C to 40°C)
Shipping Tempera ture -40°F to 158°F (-40 °C to 70°C)
Note: De rate 2°C fo r every km, up to 3000
Operating
Humidity
meters
10% to 90% RH @ 104°F (40°C),
non-condensing
Non-Operating Hum idity Up to 93% RH @ 104°F (40°C)
non-condensing
DE CL ARE D A CO UST IC NOISE LE VELS .. .. .. ... .. ..... .. ... .. .
Sound Po wer <6.03B S ound Power
Sound Pr essure <55dBA S ound Pressure
SH OC K AND V IB RATI ON . .. ... .. .. ... .. ..... .. ... .. .. ... .. ..... .
Shock, Operational
Shock, Non-Operational
Vibration, Operational
5.0G, 10 ms, half si ne
15G 11ms , half sine
0.21Grms Random 5Hz to 500Hz
flat spectrum/feed forward
Vibration, Non-Operational (1hr) X & Y axes - 0.85 Grms 3Hz - 365 Hz
Z axis - 1.2 Grms 3Hz - 365H
HI GH -AVA IL ABI LI TY FEAT UR ES
Redundant Hot-Swap Controllers
Redundant Hot-Swap Disk
Redundant Hot-Swap Fans
Redundant Hot-Swap Power
Dual Power Cords
Hot Standby Spare
Automatic Failover
Multi-Path Support
Snapshot w/AssuredSnap
Volume Copy with AssuredCopy
RE GU LATO RY
• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • •
Safety
• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • •
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
UL 60950 -1:2003 (USA)
CAN/CSA-C22.2 No. 60950-1-03 (Canad a)
EN 60950 -1 :2001 + A11 (EU)
IEC 6095 0-1 :2001 ( International)
Electromagnetic Compatibility CFR 47 Part 15 Subpart B (U.S.A. Class A)
ICES-003:2004 Class A
EN55022:2006 + A1:2007 Class A
EN51000-3-2 2006 (Harmonics)
EN61000-3-3 1995 (Amended by
A1:2001 and A2:2005) (Flicker)
EN55024 1998 (Amended by A1:2001
and A2:2003) (EU, Immunity)
RoHS and WEEE RoHS-5 Compliance , China RoHS, WEEE
Country Approval s Aust ralia/New Zealand , Canada, China (PR C),
European Union (EU), Germany (GS Ma rk),
Japan, U nited States
SU PP ORT
Software Warranty
Standard Hardware Warranty
Environmental Monitoring
Phone-home Capability
Remote Diagnostics
Non-disruptive Updates
Non-disruptive Volume Expansion
• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • •
•
90 days
3 years
SNMP, CLI, RAIDar, SMTP
Yes
Yes
Yes
Yes for primary volume s
and snap shot volumes
PH YS ICA L
Height
Depth (excluding cables)
Width
Chassis Weight
Chassis (w/250GB drives) Weight
• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • •
3.5 Inch es / 8.9cm
23.7 Inc hes / 60.2c m
17.6 Inc hes / 44.7c m
44lbs. / 19.96kg
65lbs. / 29.48kg
© 2009, Dot Hill Systems Corp., All rights reserved. Dot Hill, the Dot Hill logo, the R/Evolution logo, R/Evolution,
AssuredSnap, AssuredCopy, EcoStor and SimulCache are all trademarks of Dot Hill Systems Corp. This document is
for informational purposes only, and does not set forth any warranty, expressed or implied, concerning any equipment, equipment feature, or service offered or to be offered by Dot Hill. Dot Hill reserves the right to make
changes to this document at any time, without notice, and assumes no responsibility for its use. No part of this
document may be copied or reproduced without written permission of Dot Hill Systems Corp. 8.31.09