Doss NF622 Instruction Manual

Page 1
REV1.0
ORIGIN AL
AUTHEN TIC
e
d
p
r
d
u
e
n
t
c
t
s
a
t
,
P
i
ng
n
o
t
f
e
i
t
a
l
t
e
r
l
o
n
w
o
u
e
d
C
ORIGIN AL
AUTH
ENTIC
INSTRUCTION MANUAL INSTRUCTION MANUAL INSTRUCTION MANUAL INSTRUCTION MANUAL
HDMI Cable Tester
Page 2
Your excellent helper in cable test!
01
DESCRIPTION
The NF622 HDMI Cable Tester is designed for professional HDMI installations. This portable device allows installers to quickly test, troubleshoot, and verify HDMI (high definition multimedia interface) cables. NF622 is designed to test wire circuit state of HDMI cables with Type A & C connectors conforming to 1.0, 1.1, 1.2, 1.2a, 1.3, 1.3a, 1.3b, 1.3c, 1.4,
1.4a Category 1 and Category 2 cables. Equipped with 3 test modes, Automatically fast/slow scan or manual test for step by step, this tool can either test the conductors in straightshortopencrossover in all RGB conductors.
SAFETY INFORMATION
Safety is essential in the use and maintenance of equipment. This instruction manual and any markings on the tool provide information for avoiding hazards and unsafe practices related to the use of this tool. Observe all of the safety information provided.
Warnings
Do not connect tester to a live circuit as it may
damage the unit.
It is easy to damage this tester with charged HDMI lines.
Caution
Read all instructions in this manual before using this tester. Failure to do so may result in damage to the tester or injury to the user.
Do not drop or get the unit wet. Do not expose tester to extreme humidity or direct sunlight.
Page 3
Your excellent helper in cable test!
02
Do not use this tester with its case open, or with parts removed. Doing so may damage the tester and/or injure the user.
Repairs and maintenance must only be carried out by qualified service personnel or qualified electricians/ technicians who know the dangers.
Follow the recommendations of any Trade Organizations or Regulatory Agencies whose scope encompasses the use of this tester or injury to the user.
Remove the battery when the tester not in use for longer than a month. Chemical leakage from the battery could damage the tester.
Please use batteries according to the specification; otherwise it may result in damage to equipment.
CONTENTS
Your NF622 HDMI Cable Tester contains the following
FEATURES:
The NF622 HDMI cable tester allows the fast and accurate verification both HDMI type A and Type C cables, mapping continuity and proper configuration and displays 19 pins and shield connection status on both main and remote unit.
1
. 1 x Master unit.
2. 1 x Remote unit.
3. 1 x Pouch bag.
4. Users' Manual.
Page 4
Your excellent helper in cable test!
03
For HDMI cables Type A, C
Test all HDMI cables with Type A to A, A to C and C to C connectors, especially for fragile, easily damaged HDMI patch cord and in-wall HDMI cables.
Loopback function
Design with loopback function allows test HDMI type A to A, A to C on main unit.
3 Test Modes
Fast continuity scans for testing all conductors'
status in a cable.
Slow continuity scans for testing all conductors'
status in a cable.
Manual test for step by step scan detecting of
individual conductors' situation.
HDMI Cable Mapping
Automatically detect wiring on HDMI type A or type C condition in straightshortopencrossover in pin #1~#19 and Shield conductor.
Troubleshooting
Quickly troubleshoot and verify HDTV installation and DIY termination in the field.
Page 5
Your excellent helper in cable test!
04
SPECIFICATIONS:
Cables Tested:HDMI cables with Type A & C
connectors conforming to 1.0, 1.1, 1.2, 1.2a, 1.3, 1.3a,
1.3b, 1.3c, 1.4, 1.4a Category 1 and Category 2 cables.
Support test (main unit and remote unit):
19 pin-to-pin wire map and shielding detection.
Test interface of Master unit:
HDMI (type A) ×1 pcs, Mini HDMI (type C) ×1 pcs.
Test interface of Remote unit:
HDMI (type A) ×1pcs, Mini HDMI (type C) ×1 pcs.
Cable length:Under 50 meters. Test Mode:
Automatically fast scanAutomatically Slow scan.
Displays:
19 LEDs and shield LED on both main and remote unit.
Beeper indication. Low battery indication:Under 6.0V Power source:
DC 9V(NEAD 1604/6F22)×1 (not included)
Dimension:
Main unit:103×66×27,Remote unit103×35×27 mm
Weight:130g (not incuding battery) Operating environment:
32ºF to 104ºF (0ºC to 40ºC)80% RH
Storage environment:
14ºF to 122ºF (-10ºC to +50ºC)70% RH
Page 6
Your excellent helper in cable test!
05
PRODUCT DIAGRAM(Fig 1)
1.LOOPBACKMini-HDMI (C Type) This socket not only can be used on Master unit loopback test but also can be used on Master unit Mini-HDMI (C Type) with Remote unit Mini-HDMI (C Type) to perform scan test.
2.MAINHDMI (A Type)
3.LOOPBACKHDMI (A Type)
4.Remote unitHDMI (A Type)
5.Remote unitMini-HDMI (C Type)
6.SwitchMASTER/OFF/REMOTE
7.TESTAutomatic fast/slow scan or manual test for step by step.
8.Power and low battery indication.
9.HDMI (A Type) Pin number.
10.Mini-HDMI (C Type) Pin number.
11.LED for indicating signal situation.
Fig 1
Master Unit Remote Unit
2
1 4
5
6
8
9
10
11
3
7
Dat
a 2+
Dat
a 2-
Data 1 S
Dat
a 0+
Dat
a 0-
Cloc k S
CEC
SCL
DDC/ CEC
Hot P
lug
Shie ld
Data 2 S
Dat
a 1+
Dat
a 1-
Data 0 S
Cloc k -
SDA
+5V Po wer
Cloc k +
C pin A pin
C pin
A pin
Uti. /Res.
S
S
MASTER
REMOTE
Cloc k S
CEC
SCL
DDC/ CEC
Hot Pl ug
Shie ld
Cloc k -
SDA
+5
V Powe r
Data 2 +
Data 2 -
Data 1 S
Data 0 +
Data 0
-
Data 2 S
Data 1
+
Data 1 -
Data 0
S
Cloc k +
Uti. /
Res.
S
C pin
A pin C pi n
A pin
S
Page 7
Your excellent helper in cable test!
06
HDMI Cable Wire / Pin And Signal Description:
HDMI
(A)Pin #
1 2 3 4 5 6 7 8 9
10
11
12
13
14 15 16
17
18 19
S
2
1 3 5 4 6 8 7 9
11 10 12
14
17 15 16
13
18 19
S
Data 2+
Data 2S
Data 2-
Data 1+
Data 1S
Data 1-
Data 0+
Data 0S
Data 0-
Clock +
Clock S
Clock -
CEC
Reserved
SCL
SDA
DDC/CEC
+5V Power
Hot Plug
Shied
TMDS Red Data Plus
TMDS Red Data Shield
TMDS Red Data Minus
TMDS Green Data Plus
TMDS Green Data Shield
TMDS Green Data Minus
TMDS Blue Data Plus
Consumer Electronics Control
Utility/Reserved
Serial Clock
Serial Data
Data shield for the display data channel and consu­mer electronics control
+5V Power
Hot Plug Detect
Shied
MINI-HDMI
(C) #Pin
TMDS Blue Data Shield
TMDS Blue Data Minus
TMDS Clock Plus
TMDS Clock Shield
TMDS Clock Minus
Pin
Assignment
Signal Description
Page 8
Your excellent helper in cable test!
07
Power off:
Slide upper left switch to “OFF”,”POWER” LED will go out and the unit will no longer work when pushing the “TEST” button.
135791113
151719
2468101214
1618
Corresponding to the Pins Definition of the HDMI cables(Fig 2)
OPERATION
Note
When all LEDs are lighted all LEDs will decrease
brightness.
Master unit shorted pins LED will be brighter than
others when shorted 2 pins above that is correct.
Shield LED will light up after #1~19 LEDs light up in
sequence on any testing mode. If the HDMI cable has a shield, the Shield LED will light up, if without shield the LED will be unlighted.Power off
Page 9
Your excellent helper in cable test!
08
Master unit loop continuity scan testing function
Note
When performing master unit scan test, sequence of LEDs light up as below.LED#1 (Data 2﹢) LED#10 (Clock ﹢) LED#S (Shield) LED#11 (Clock S).
Insert one of A type connector of cable to Master
unit LOOPBACK (A Type) socket and insert the other one to Master unit MAIN (A Type) socket for test HDMI cable A type to A type.
Insert A type connector of cable to Master unit
LOOPBACK (A Type) socket and insert C type connector of cable to Master unit Mini-HDMI (C Type) for test HDMI cable A type to Mini-HDMI (C Type).
1.Slide upper left switch to “MASTER” then “POWER” LED lights up, Master unit #1~19 and “Shield” LEDs will all light up with a long beep sound then all LEDs are off except “POWER”LED for saving power and the unit is ready for testing.
2.Push “TEST” button to perform master unit continuity scan test, it will continually scan 1~19 pin and shield conductor, Master unit #1~19 and Shield LEDs will light up in sequence fast, finally master unit LED will indicate testing result with sound as below. The testing result will keep 5 second then all LEDs are off except “POWER” LED for saving power. Press “TEST” button again for test.
Page 10
Your excellent helper in cable test!
09
3. Master unit scan test result with beep sound as below.
Straight: With a long “beep” sound: Meaning
1~19pin and S pin all straight connected. (Fig 3.)
Open: with a short “beep” soundNo connected
pins LED are off. Example: Test HDMI (A Type) to HDMI (A Type) cable that pin #2, #5, #8 and #11 are not connected , or test HDMI (A Type) to Mini-HDMI (C Type) cable that pin #1#4#7#10 are not connected. (Fig 4.)
Short: With three short “beep” sound. Shorted pins
LED will light up at same time. Example: Test HDMI (A Type) to HDMI (A Type) cable that pin #4#5#6 are shorted or test HDMI (A Type) to Mini-HDMI (C Type) cable that pin #4#5#6 are shorted. (Fig 5.)
Crossover: With two short “beep” sound. Crossed
pins LED will light on at same time. Example: Test HDMI (A Type) to HDMI (A Type) cable that pin #13 crossed with pin #17 and pin #14 crossed with pin #19, or test HDMI A Type) to Mini-HDMI (C Type) cable that pin #14 crossed with pin #13 and pin #17 crossed with pin #19. (Fig 6.)
Page 11
Your excellent helper in cable test!
10
Fig 3 . Straight
MASTER
REMOTE
Data 2+
Data 2-
Data 1S
Data 0+
Data 0-
Clock S
CEC
SCL
DDC/C EC
Hot Plu g
Shiel d
Data 2S
Data 1+
Data 1-
Data 0S
Clock -
SDA
+5V Pow er
Clock +
C pin A pin
C pin
A pin
Uti./ Res.
S S
MASTER
REMOTE
Data 2+
Data 2-
Data 1S
Data 0+
Data 0-
Clock S
CEC
SCL
DDC/C EC
Hot Plu g
Shiel d
Data 2S
Data 1+
Data 1-
Data 0S
Clock -
SDA
+5V Pow er
Clock +
C pin A pin
C pin
A pin
Uti./ Res.
S S
Fig 4 . Open
Fig 5 . Short
MASTER
REMOTE
Data 2+
Data 2-
Data 1S
Data 0+
Data 0-
Clock S
CEC
SCL
DDC/C EC
Hot Plu g
Shiel d
Data 2S
Data 1+
Data 1-
Data 0S
Clock -
SDA
+5V Pow er
Clock +
C pin A pin C pin
A pin
Uti./ Res.
S S
MASTER
REMOTE
Data 2+
Data 2-
Data 1S
Data 0+
Data 0-
Clock S
CEC
SCL
DDC/C EC
Hot Plu g
Shiel d
Data 2S
Data 1+
Data 1-
Data 0S
Clock -
SDA
+5V Pow er
Clock +
C pin A pin C pin
A pin
Uti./ Res.
S S
Fig 6 . Crossover
Page 12
Your excellent helper in cable test!
11
Master unit with Remote unit automatic testing function
MAIN (A Type) socket and insert the other one to Remote unit A Type connector for test HDMI cable A type to A type. Insert A type connector to Master unit LOOPBACK
(A Type) and insert C type connector to Remote unit Mini-HDMI (C Type) for test HDMI cable A type to Mini-HDMI (C Type). Insert one of C type connectors of cable to Master
unit Mini-HDMI (C Type) socket and insert the other one to Remote unite (C Type) socket for test HDMI cable Mini-HDMI (C Type) to Mini-HDMI (C Type) socket.
1.Slide upper left switch to “REMOTE” then “POWER” LED lights up. Master unit #1~19 and “Shield” LEDs will all light up with a long beep sound then Master unit and Remote unit both #1~19 and “Shield” LEDs will indicate tested result. Testing result will keep 12 seconds then all of LED are off except “POWER”LED for saving power.
2.Press “ TEST” button then Master unit and Remote unit both #1~19 and “Shield” LEDs will indicate tested result. Testing result will keep 12 seconds then all LEDs are off except “POWER”LED for saving power.
Insert one of A type connector of cable to Master unit
1.LED indicates test result as below:
Straight Master unit and Remote unit both testing pin
#1~19 and “Shield” LEDs are all lighted up. (Fig 7.)
:
Page 13
Your excellent helper in cable test!
12
Open: Master unit and Remote unit both no connected
pins LEDs are off. (Fig 8.)
Short: Master unit testing short pin LEDs brighter
than others. Remote unit shorted pins LEDs are off.
(Fig 9.)
Crossover: It can't be tested on this mode.
Master unit with Remote unit slow continuity scan testing function:
1.Press “ TEST button during LED indicate automatic testing result or Press twice “ TEST” button before LED off for perform automatic testing, it will continually scan #1~#19 pin and shield conductor. Master unit and Remote unit both #1~19 and Shield LEDs will light up in sequence very slow and sustained repeated automatic scan.
2.LED indicate testing result as below
: Master unit and Remote unit both testing
pins #1~19 and Shield LEDs are all lighted up in sequence.
(Fig 7.)
Open: Master unit and Remote unit both LEDs are
off when scan to no connected pins, others LEDs are all lighted up in sequence. Example : Test HDMI (A Type) to HDMI (A Type) cable that pin #2#5#8 #11 are not connected, or test HDMI (A Type) to Mini-HDMI (C Type) cable that pin #1#4#7#10 are not connected, or test Mini-HDMI (C Type) to Mini-HDMI (C Type) cable that pin #1#4#7#10 are not connected. (Fig 8.)
Straight
Page 14
Your excellent helper in cable test!
13
Short: Master unit LED brighter than others and
Remote unit LED off when scan to shorted pins, Master unit and Remote unit both LED are all lighted up in sequence, Example : Test HDMI (A Type) to
HDMI (A Type) cable that pin #4#5#6 are shorted, or teat HDMI (A Type) to Mini-HDMI (C Type) cable
that pin #4#5#6 are shorted, or test Mini-HDMI
(C Type) to Mini-HDMI (C Type) cable that pin #4#5
#6 are shorted. (Fig 9.) Crossover: Master unit LEDs light up in sequence
and Remote unit LEDs light up sequence by crossed pins, Example : test HDMI (A Type) to HDMI (A Type) cable that pin #13 with pin#17 are crossed and pin #14 with pin #19 are crossed, or test HDMI (A Type) to Mini-HDMI (C Type) cable pin #14 with pin #13 and pin #17 with pin #19 are crossed, or test Mini-HDMI (C Type) to Mini-HDMI (C Type) cable pin #14 with pin #13 are crossed and pin #17 crossed with #19 are crossed. (Fig 10.)
Page 15
Your excellent helper in cable test!
14
Fig 8 . Open
MASTER
REMOTE
Data 2+
Data 2-
Data 1S
Data 0+
Data 0-
Clock S
CEC
SCL
DDC/C EC
Hot Plu g
Shiel d
Data 2S
Data 1+
Data 1-
Data 0S
Clock -
SDA
+5V Pow er
Clock +
C pin A pin C pin
A pin
Uti./ Res.
S S
Clock S
CEC
SCL
DDC/C EC
Hot Plu g
Shiel d
Clock -
SDA
+5V Pow er
Uti./ Res.
S
C pin A pin
S
Data 2+
Data 2-
Data 1S
Data 0+
Data 0-
Data 2S
Data 1+
Data 1-
Data 0S
Clock +
C pin
A pin
MASTER
REMOTE
Data 2+
Data 2-
Data 1S
Data 0+
Data 0-
Clock S
CEC
SCL
DDC/C EC
Hot Plu g
Shiel d
Data 2S
Data 1+
Data 1-
Data 0S
Clock -
SDA
+5V Pow er
Clock +
C pin A pin C pin
A pin
Uti./ Res.
S S
Clock S
CEC
SCL
DDC/C EC
Hot Plu g
Shiel d
Clock -
SDA
+5V Pow er
Uti./ Res.
S
C pin A pin
S
Data 2+
Data 2-
Data 1S
Data 0+
Data 0-
Data 2S
Data 1+
Data 1-
Data 0S
Clock +
C pin
A pin
Fig 7 . Straight
Page 16
Your excellent helper in cable test!
15
MASTER
REMOTE
Data 2+
Data 2-
Data 1S
Data 0+
Data 0-
Clock S
CEC
SCL
DDC/C EC
Hot Plu g
Shiel d
Data 2S
Data 1+
Data 1-
Data 0S
Clock -
SDA
+5V Pow er
Clock +
C pin A pin
C pin
A pin
Uti./ Res.
S S
Fig 10 . Crossover
Clock S
CEC
SCL
DDC/C EC
Hot Plu g
Shiel d
Clock -
SDA
+5V Pow er
Uti./ Res.
S
C pin A pin
S
Data 2+
Data 2-
Data 1S
Data 0+
Data 0-
Data 2S
Data 1+
Data 1-
Data 0S
Clock +
C pin
A pin
Fig 9 . Short
MASTER
REMOTE
Data 2+
Data 2-
Data 1S
Data 0+
Data 0-
Clock S
CEC
SCL
DDC/C EC
Hot Plu g
Shiel d
Data 2S
Data 1+
Data 1-
Data 0S
Clock -
SDA
+5V Pow er
Clock +
C pin A pin C pin
A pin
Uti./ Res.
S S
Clock S
CEC
SCL
DDC/C EC
Hot Plu g
Shiel d
Clock -
SDA
+5V Pow er
Uti./ Res.
S
C pin A pin
S
Data 2+
Data 2-
Data 1S
Data 0+
Data 0-
Data 2S
Data 1+
Data 1-
Data 0S
Clock +
C pin
A pin
Page 17
Your excellent helper in cable test!
16
Master unit with Remote unit fast continuity scan testing function:
1.Press “ TEST” button during the slow continuity scan testing, or press three times“ TEST” button after the automatic testing LEDs are offIt will fast scan pin 1~19pin and ShieldMaster unit and Remote unit both #1~19 and Shield LEDs will light up in sequence fast and sustained repeated automatic scan.
2.The test result please refer to the slow continuity scan testing function. (Fig 7. ~ Fig 10.)
Master unit with Remote unit manual scan testing function:
1.Press “ TEST” button for three seconds until pin #1 LED lights up, pin #2 ~ 19pinShield LEDs light up step by step sequentially after pressing “ TEST” button and sustained repeating.
2.The test result please refer to the slow continuity scan testing function. (Fig 7. ~ Fig 10.)
3.Press “ TEST” button three seconds again then go back to automatic testing mode.
Page 18
Your excellent helper in cable test!
17
BATTERY LIFE AND REPLACEMENT:
Caution
as soon as the low battery indication appears.
To avoid unreliable test results, replace the battery
Warnings
turn off the master unit and disconnect all test leads before replacing the battery.
To avoid possible electric shock or personal injury,
Battery Status:When ”POWER/LOW BATT.” LED is flashing on the master unit, it means the battery voltage is under 6.0V which couldn't power the device on. Please replace the battery as the following step:
1.Turn off the master unit and disconnect all test leads before replacing the battery.
2.Properly replace the battery into the battery case.
3.Use only a DC 9V(NEAD 1604/6F22) battery.
HDMI® is a registered trademark of HDMI Licensing, LLC.
Page 19
Your excellent helper in cable test!
18
Page 20
Loading...