dosatron D8 RANGE Quick Start-up

Page 1
QUICK START UP
CAUTION
- When connecting a DOSATRON either to the public water supply or to its own water source, you must respect the regulations in force concerning protection of the source i.e. backflow prevention, etc.
- When installing, operating, and maintaining the DOSATRON water powered metering pump, keep safety considerations foremost. Use proper tools, protective clothings, and eye protection when working on the equipment and install the equipment with a view toward ensuring safe operation.
- Follow the instructions in the manual and take additional safety measures appropriate to the liquid being pumped and the temperature of the water that powers the DOSATRON. Be extremely careful in the presence of hazardous substances (e.g. corrosives, toxins, solvents, acids, caustic, flammables, etc.).
- Before applying any aggressive chemicals, please consult your distributor to confirm compatibility with the dosing pump.
Hand tighten. No tools needed.
Congratulations on your new Dosatron. Please read the following important information.
IMPORTANT NOTES
For complete information on the features and operations,
refer to your manual on www.dosatron.com
or download our DOSATRON app
or
NEED HELP ? Contact your DOSATRON distributor
for service or parts.
D8 RANGE 8 m
3
/h - 40 US GPM
ET283/Warning-D8-EN-US/11/15
8
m3/h
This document does not form a contractual engagement on the part of Dosatron International and is for information only. Dosatron International reserves the right to alter product specification or appearance without prior notice.
© DOSATRON INTERNATIONAL S.A.S 2012
CUSTOMER SERVICE - SERVICE CLIENTÈLE (NORTH & CENTRAL AMERICA)
DOSATRON INTERNATIONAL INC.
2090 SUNNYDALE BLVD. CLEARWATER - FL 33765 - USA
Tel. 1-727-443-5404 / 1-800-523-8499 - Fax 1-727-447-0591 Site web: www.dosatronusa.com
www.dosatron.com
40 US GPM
DOSATRON INTERNATIONAL S.A.S. Certified QEH&S System
Rue Pascal - B.P. 6 - 33370 TRESSES (BORDEAUX) - FRANCE
Tel. 33 (0)5 57 97 11 11 Fax. 33 (0)5 57 97 11 29 / 33 (0)5 57 97 10 85 info@dosatron.com - www.dosatron.com
CUSTOMER SERVICE - SERVICE CLIENTÈLE (WORLDWIDE - EUROPE) MANUFACTURED BY - FABRIQUÉ PAR :
RECOMMENDATIONS
DO NOT USE THIS UNIT WITHOUT A 60 MICRON
[300 MESH] WATER FILTER*
OR YOUR WARRANTY WILL BE VOID.
*The 60 micron [300 mesh] water lter (sold separately)
protects your unit from debris in the water that causes
scoring to the piston and housing.
KNOW YOUR WATER FLOW!
GRADUALLY TURN ON THE WATER.
COUNT THE NUMBER OF CLICKS IN
15 SECONDS. DO NOT EXCEED 40* CLICKS.
MAXIMUM PRESSURE 8 bar [110 PSI]
CLICK CHART
Clicks/15sec l/h GPM
4 820 3,6
8 1640 7,2
16 3280 14,5
32 6500 29
40 8000 36
Page 2
8EQ001 (option)
Ø 16 Ø 20
w
a
t
e
r
f
o
w
Max.Torque 30 Nm thus 3 kg (1 N.m = 0,1 DaN.m)
Valve
Check valve
Filter
Filter :
60 microns [300 mesh]
Depending on your
water quality
Maximum: 40 clicks/15 sec.
NO !
When possible,
DO NOT PLACE
the container directly
under
the DOSATRON
BY PASS Option
Air-Bleed
Button
1
2
1 2
3
4
5
6 7
8 9
INSTALLATION HINTS
Scan the QR­code on the dosing pump.
Loading...