Dors 1300 User Manual

Page 1
www.sintro.com.au
MULTIFUNCTIONAL COUNTERFEIT DETECTOR
USER MANUAL
Pantone 300 C EBKM.1300M2.00.00.000-02UM Int
2017
User Manual Version 0.0
Production date:
Page 2
3
Contents
MULTIFUNCTIONAL COUNTERFEIT DETECTOR DORS 1300
EBKM.1300M2.00.00.000-02UM IntBlack
BRIEF INFORMATION FOR CUSTOMER...................................................... 4
PURPOSE....................................................................................................... 4
IMPORTANT INFORMATION.......................................................................... 6
DELIVERY SET............................................................................................... 7
APPEARANCE................................................................................................ 7
PREPARING FOR OPERATION..................................................................... 9
OPERATION.................................................................................................... 9
CARE AND MAINTENANCE........................................................................... 23
TROUBLESHOOTING.................................................................................... 26
SPECIFICATIONS.......................................................................................... 27
TRANSPORTATION, STORAGE AND DISPOSAL........................................ 27
SUPPORT AND WARRANTY......................................................................... 28
Page 3
4
We thank you for your choice of Multifunctional Counterfeit Detector DORS 1300.
READ THE MANUAL WITH ATTENTION
BEFORE YOU START TO WORK!
5
THE DEVICE HELPS TO
The UV marks may be examined on the surface of the document when it is put on the viewing table of the device. The IR marks and IR blink marks can be examined on the 7" LCD of the device. When the IR marks are being inspected on the display, a 20-fold zoom mode makes it possible to check the structure of the mark lines without the video magnifier.
Anti-Stokes luminescence can be observed on the document at the point of laser focusing (see. Fig. 1). Upon de tection of the Anti-Stokes the audio signal is generated (this function can also be deactivated through on-screen menu). The information about the presence and type of applied luminophore is displayed on the monitor.
The prese nce of magnet ic ink is con trolled by th e b uilt-in ma gnetic sensor. Upon detection of magnetic ink the short audio signal is generated.
The device has an additional video input that makes it possible to display video from an external video signal source, for example, from a CCTV camera. The video output may be used for transmitting the image to an external display or a computer.
MULTIFUNCTIONAL COUNTERFEIT DETECTOR DORS 1300MULTIFUNCTIONAL COUNTERFEIT DETECTOR DORS 1300
EBKM.1300M2.00.00.000-02UM IntBlack
An ult raviolet (her eafter – UV) source con sisting of 3 fluo rescent lamps (6W each);
A top infrared (her eafte r – ) source emitting at the 850 nm and 940 nm IR wavelength; Top white oblique source with an opportunity to examine a variable-color inks (OVI); A viewing table with combined illumination – transmitted IR light and white
light; Laser light source (950 nm)
Magnetic ink sensor 7" color TFT LCD; Two video cameras transmitting image of the banknote (document) on the viewing table to the LCD screen in scale 1:1 or with 20-fold magnification; The connectors for video magnifier DORS 1020, and a detector of magnetic and IR marks DORS 15; An additional video input and a video output.
BRIEF INFORMATION FOR CUSTOMER
The multifunctional counterfeit detector DORS 1300 is developed by DORS R&D and is assembled in China by DORS Industries (China) Ltd.
Service term is 7 years under condition that detector is being used in strict accordance with this User Manual and applied technical standards.
PURPOSE
Multifunctional counterfeit detector DORS 1300 (hereafter – «the device») shall be used for a visual detection of authenticity of banknotes, securities, excise stamps and other documents with the protective marks that may be verified by the device.
THE DEVICE IS EQUIPPED WITH
3. Verify a luminescence of the specific areas of a banknote (document) in UV light (marks, security threads and fibers).
4. Verify watermarks and security threads on banknote (document).
5. Examine the surface of banknotes or documents with protection elements in a
whi te obli que ref lected light. This way you can verify the rel ief of printed elements, and a tilting effect.
6. Verify an authenticity of micro perforations.
7. Verify the security elements on a banknote that are printed with a variable color ink (OVI).
8. Perform an advanced verification under a 20-fold magnification in two bands
(white /IR) when using a built- in 20x ca mera or and in t hree bands (white/IR/UV) when using the video magnifier DORS 1020. This way you can verify a coincidence of thin multicolored lines of the currency design, a readability of a microtext and the currency design at specific points.
9.
10.
Verify a presence of magnetic inks.
Control a presence of the Anti-stokes luminescence and recognize a type of applied luminophore. This type of control is applicable to the limited number of currencies (GBP, MXN, CNY,RUB).
1. Verify absence of a general visible lum inescence in ultravio let lig ht on a banknote (document).
2. Verify a presence of IR marks in a reflected and transmitted light as well as verify IR blink marks in two-wave lengths mode (940/850 nm).
Page 4
The device is c ontr olled with an on -scr een menu system. The re are special buttons for the most frequently used functions. The device may be used by a cashier who had been trained in a visual detection of authenticity of banknotes after he has studied the given manual.
IMPORTANT INFORMATION
APPEARANCE
6
7MULTIFUNCTIONAL COUNTERFEIT DETECTOR DORS 1300MULTIFUNCTIONAL COUNTERFEIT DETECTOR DORS 1300
EBKM.1300M2.00.00.000-02UM IntBlack
IT IS PROHIBITED TO LOOK AT THE UV-LAMPS DURING THE DEVICE OPERATION.
IT IS PROHIBITE D TO TOUC H THE DEVICE AND THE POWER CORD PLUG WITH WET HANDS. IT MAY RESULT IN AN ELECTRIC SHOCK.
WARNING! UNPL UGING THE DEVICE FROM THE POWER OUTLET, HOLD THE PLUG, NOT POWER CORD TO AVOID ANY DAMAGE OF THE CORD.
WARNING! TO AVOI D ANY POW ER COR D DAMA GE AND A SHORT CIRCUIT, MOVE THE DEVICE ONLY AFTER THE POWER CORD PLUG HAS BEEN DISCONNECTED FROM THE POWER SUPPLY.
ATTENTION! THE DEVICE IS TO BE INSTALL ED ON A HORIZ ONTAL PLANE OF A WORKING TABLE. IT IS PROHIBITED TO INSTALL THE DEVICE WITH ITS UV-LAMPS BEING VISIBLE FOR THE OPERATOR.
ATTENTION! IF THE DEVICE HAS BEEN UNDER COLD CONDITIONS FOR A L ONG TIME, I T SHALL B E K EPT U NDER R OOM TEMPERATU­RE FOR NOT LESS THAN TWO HOURS BEFORE ITS SWITCHING ON.
INVISIBLE LASER RADIATION! DO NOT USE ANY OPTICAL DEVICE TO OBSERVE A BANKNOTE WHEN IT’S WITHIN THE VIEWING AREA. CLASS 1M LASER PRODUCT. THE LOCATION OF THE OUTPUT APERTURE OF THE LASER AND THE
VIEWING AREA ARE SHOWN AT FIG.1. IT I S RECOMME NDED TO SWITCH ON TH E UV LIG HT WHEN CAR -
RYING OUT EXAMINATION AND SWITCH IT OFF AT THE END OF EXAM­INATION.
ATTENTION! TO PROVIDE A SUCCESSFUL OPERATION OF THE DE­VICE FOR A LONG TIME WITHOUT AN INTERFERENCE OF A TECHNI­CIAN, OBSERVE THE FOLLOWING RULES:
1. THE DEVICE SHALL BE INSTALLED ON AN EVEN HORIZONTAL SURFACE.
2. WHEN I NSTAL LING THE DEVICE , AVOID ITS E XPOSURE TO DIRECT SUNLI GHT AND SPOT LIGHT ARTIFICIAL ILLUMINA-
TION. WARNING! TO AVOID AN ELECTRIC SHOCK, APPLY TO A QUALIFIED
SPECIALIST TO REPLACE THE LAMPS. IT IS PROHIBITED TO DISPOSE THE USED LAMPS IN THE DOMESTIC
GARBAGE CONTAINERS. AFTER A LAMP HA S BEEN REPLACED, IT SHALL BE HANDED IN TO THE SERVICE OF FLUORESCENT LAMPS DISPOSAL.
Multifunctional counterfeit detector DORS1300 ........................................ 1 pc.
User manual .............................................................................................. 1 pc.
Packaging................................................................................................... 1 set.
DELIVERY SET
Fig. 1. Front view
18 Anti-Stokes mark detection module 19 Magnetic bias area 20 Magnetic ink sensor
18
19
20
A
Output aperture
of the laser
Viewing area
of the
Anti-Stokes mark
A
1 Viewing table 2 Display 3 Slot for a large-sized document 4 UV-lamp (one in three is shown) 5 Power switch 6 TV key (selection of the source
for an image on the display) 7 DL key (selection of white
illumination)
8 IR key (selection of IR - illumination type)
9 UV key (selection of UV - illumination) 10 Menu control keys
Page 5
8 9
PREPARING FOR OPERA
TION
If it is supposed to use additional external devices (DORS 15, DORS 10 20) dur ing th e device o per ati on, they s hal l be co nne cte d to th e
corresponding r ear pa nel jacks before the device is connected to the mains. Video magnifier DORS 1020 is connected to the jacks V1 or V2 (, ), a nd DO RS 15 dete ctor of ma gnet ic an d IR marks — to the jacks M1 or M2 (,).
MULTIFUNCTIONAL COUNTERFEIT DETECTOR DORS 1300MULTIFUNCTIONAL COUNTERFEIT DETECTOR DORS 1300
EBKM.1300M2.00.00.000-02UM IntBlack
APPEARANCE
2 Display 3 Slot for a large-sized document 11 Power cord 12, 13 Connectors V1, V2 for
DORS 1010 (DORS 1020)
14 Connector IN to connect to an
external video signal source 15 Connector OUT to connect to the computer or an external display
16, 17 Connectors M1, M2 to connect
DORS 10 (DORS 15)
Fig. 2. Rear view
ATTENT ION ! BEFORE THE DE VICE OP ERATION STA RTS , MAKE SURE ABOUT INTEGRITY OF ITS BODY AND THE THREE FLUORES­CENT LAMPS  . IT IS PRO HI BI TE D TO CO NNECT TO THE PO WER SU PP LY TH E PR OD UC T WI TH A DAMAG ED BODY, WITH TH E DA MA GE D UV­LAMPS OR WITHOUT THEM.
The device is supplied in a package with display body in lower position .
This position of the display is for transportation or moving the device to a different working place. The display body may be turned around the horizontal and vertical axes to provide the best view. After the device has been installed on its working place, it is necessary to li ft the display body to its working position and orient it is so that the operator ’s glance would be perpendicular to the screen surface.
To start the device operation, the power cord shall be connected to pow er socket 110-240 VAC 50/6 0 Hz. Then to switch on th e dev ice, press the power switch . A built-in red indicator will turn on showing that th e device is s witched on. Aft er a 7-10 sec ond ener gizing, the display dri ver is initializ ed, the working sett ings are loaded and the detector undergoes self-testing. Until this process is finished, the device controls are disabled. Appearance of «Self-testing... Please wait!» on the screen means the self-testing stage has started. The first switching on establishes the mode of the IR marks inspection in a reflected light.
OPERATION
Use the corresponding mode control keys to select the required operation mode. These keys provide an access to the most frequently used functions of the device. Let’s consider them in brief.
ATTENTION! DURING IGNITION OF THE UV AND WHITE LAMPS, ALL THE KEYS GET DIS ABLED . A N A CTIVE STATE OF THE KEY S IS RE­COVERED AFTER IGNITION OF THE LAMPS HAS BEEN COMPLETED.
1. TV key swit ches the so urce of the image appe aring on th e device
display. The image sources may be both device cameras (with zoom1x and zoom 20x), and the external devices connected to connectors V1, V2, IN.
Page 6
10
11MULTIFUNCTIONAL COUNTERFEIT DETECTOR DORS 1300MULTIFUNCTIONAL COUNTERFEIT DETECTOR DORS 1300
EBKM.1300M2.00.00.000-02UM IntBlack
1.1 Short pressing of the TV key switches the modes of the image from the device built-in cameras.
■ The first short pressing switches on a 20x zoom displaying. The
«Zoom 20x» message appears on the display for several seconds. After the time has expired, the display restores the message about the current illumination mode, for example, «IR».
■ The second short pressing returns the image without zoom. The
«Zoom 1x» message appears on the display for several seconds. After the time has expired, the display shows a restored message about the current illumination mode, for example, «IR».
■ Any further short pressing results in the same switching as after
the first pressing, the second one etc.
1.2 A long pressing of the TV key results in displaying an image from an external video source (from input V1), the image is accompanied by the «Video input V1» message appearing on the display for several seconds. After the time has expired, there is displayed a message about the current illumination mode set in the signal source (a video magnifier), for example, «Video 1 IR», connected to the given video input.
1.2a Any further short pressing of the TV key results in connection of
the display to video inputs V2 and IN.
■ The firs t shor t p ressing switc hes on di spla ying f rom input V2
accompan ied by the «Video input V2» message displayed fo r several seconds. After the time has expired, there is displayed a mes sage about the current illumination mode s et in the signal source (a video magnifier), for example, «Video 2 UV», connected to the given video input.
■ The second short pressing switches on displaying from input IN
with the «Video input In» message displayed for several seconds. After the ti me has ex pire d, there is display ed the «Vi deo In» message.
■ The third short pressing results in returning to displaying from input
V1 which is accomp anied by the «Video in put V1» m essage displayed for several seconds. After the time has expired, there is a message displayed about the current illumination mode set in the signal source (a video magnifier), for example, «Video 1 IR» con-
nected to the given video input.
■ Any further short pressing results in the same switching over as after the first pressing, the second one etc.
1.2b To retu rn to the image from the de vice built-in camera, it is
necessary to press the TV key once more for a long time.
2. DL key controls switching on of the top oblique white light as well
as a combined illumination of the viewing table by white light and transmitted IR light. The source of the top white light may be switched
on in the mode of s witching of the in cidence angle. Illu mination of the viewing table and an oblique white light do not switch on simultaneously.
The first pressing switches on illumination of the viewing table by white light and transmitted IR light. There is displayed the «TOP White» message for several seconds. After the time has expired, there is a message about the current illumination mode, i.e. «TOP White+IR».
■ A resul t of ne xt press ing is depended on current magnifica tion mode: а. No magnification ():
A mix ed light cons ist ed of top white light and IR l igh t is switched on. There is displayed the «TOP White» message for several seconds. After the time has expired, there is a message about the current illumination mode, i.e. «TOP White+IR».
b. 20x magnification:
A top white light is switched on. A message «TOP WHITE» is appeared on the screen.
■ The third pressing is caused a switching on of oblique white light. A message «Oblique white» is appeared on the screen.
■ Th e f ourt h p ress ing tra nsfe rs the top wh ite lig ht sour ce to the mode of a variable color ink verifying. This mode is an alternate switching on of either an oblique white light source or a top white lig ht sour ce. The banknote security mark printed in a variable color ink will alternately change its color because of the difference in the light incidence angles on the viewing table.
When you choose this OVI control mode, a type of illumination is also depended on current magnification mode: a. No magnification ():
A mixed light consisted of Top white light for variable ink cont-
rol and IR light is switched on. A message «Variable color» is
appeared on the screen for few seconds, then it will be replaced with a message «Variable color + IR» which means a current type of illumination.
Page 7
12
13
Key (Up) Key (Right) Key (Down)Key
(Left)
SET key
(Set)
Fig. 3. The on-screen menu control keys
Table 1 is explained the functions of the menu operation keys. After the device has been switched on, the menu is disabled. To enter the menu, press SET key . Then use the keys 18, 19, 20, 21 to select the required menu item. To enter the selected menu item, press SET.
MULTIFUNCTIONAL COUNTERFEIT DETECTOR DORS 1300MULTIFUNCTIONAL COUNTERFEIT DETECTOR DORS 1300
EBKM.1300M2.00.00.000-02UM IntBlack
b. 20x magnification:
A top white light is switched on. A message «TOP WHITE» is appeared on the screen.
■ The third pressing is caused a switching on of oblique white light. A message «Oblique white» is appeared on the screen.
■ Th e f ourt h pressing transfers the top whi te light source to th e mode of a variable color ink verifying. This mode is an alternate switching on of either an oblique white light source or a top white lig ht sour ce. The ban knot e security mark printe d i n a variable color ink will alternately change its color because of the difference in the light incidence angles on the viewing table.
When you choose this OVI control mode, a type of illumination is also depended on current magnification mode: a. No magnification ():
A m ixed light co nsis ted of Top whi te light for var iabl e ink control and IR l ight i s switche d on. A m essage «Va ria ble color» is appeared on the screen for few seconds, then it will be re pla ced with a m essage «Va ria ble co lor + IR » which means a current type of illumination.
b. 20x magnification:
A top white light for v ariable ink con trol i s s wit ched o n. A message «Variable color» is appeared on the screen.
■ The fifth pressing switches off the white illumination and sets the IR illumination mode. There is displayed the «White off» message for several seconds. After the time has expired, there is a message about the current illumination mode, i.e. «IR».
■ Any further pressing results in switching over in the same way as at the first pressing, the second one etc.
3. A function of IR key is also depended on current magnification mode:
a. when there is no magnification (1х):
It is switched between IR, Anti-Stokes and IR Blink mode and displayed a message («IR» or «IR Blink» correspondingly) for several seconds. After the time has expired, there is displayed a message about the current illumination mode, i.e. «IR», «Anti-
Stokes» or «IR Blink». A banknote wideband illumination by IR light within a 800 nm – 1000 nm band takes place in IR mode.
In IR blink mode, periodical switching of the emission wave-
length from 850 nm to 940 nm and vice-versa takes place to
ver ify the IR blink mark s. If they are ex iste d on a banknot e (document), the image of the IR blink mark is started to blink on the screen.
b. when there is 20x magnification:
It is switched between IR and Anti-Stokes mode and displayed a message («IR» or «Anti-Stokes» correspondingly) for several seconds.
4. UV key switching UV lamps on/off.
The first pressing switches on a combined illumination UV+IR. «UV 365 nm» message is displayed for several seconds. After the time has expired, a message about the current illumination mode is isplayed, i.e. «UV+IR».
Further pressing switches off the UV-illumination. The The IR mode is on. The « UV off» message is displayed for several seconds. A fter the time has e xpired, a mes sage abou t the cu rren t illumin atio n mo de is displayed, i.e. «IR».
Any further pressing results in switching in the same way as at the first pressing, at the second one etc.
The on-screen menu provides an access to the device functions and set-tings. To control the on-screen menu, use a group of 5 keys . Fig. 3 shows the location and the marking of these keys.
Page 8
14
15
table 1. The functions of the on-screen menu control keys
Key pressing Functions
“SET”
In the disabled menu mode – enter the menu mode.
In the menu mode – selection of the end menu item.
In the mode of value change for the selected menu item – exit from the menu item accompanied by saving of the changed value.
and
In the menu mode – moving up/down through the menu items.
In the mode of value change for the selected menu item – change of the value (increase, decrease, moving through the list).
In the menu mode:
- enter the menu item value change
- enter the lower submenu
In the mode of value change for the selected menu item – no response
Lower submenu exit to the top submenu/ menu.
In the mode of value change for the selected menu item – exit from the menu item without saving of the changed value.
To set the required value for the menu item, use the keys ↑ and ↓. Press SET to confirm the value you choose. Press to cancel the selected value or in case of an error. Fig. 4 shows the menu structure.
Fig. 4. Structure of the DORS1300 menu
MULTIFUNCTIONAL COUNTERFEIT DETECTOR DORS 1300MULTIFUNCTIONAL COUNTERFEIT DETECTOR DORS 1300
EBKM.1300M2.00.00.000-02UM IntBlack
Sound
Sound ON
Sound OFF
UV + IR
Oblique White + IR
Top White + IR
Bottom White + IR
IR
IR + Anti-Stokes
IR blink
UV + IR
Oblique White
Top White
Bottom White + IR
IR
IR + Anti-Stokes
Sound
Page 9
16
17
MULTIFUNCTIONAL COUNTERFEIT DETECTOR DORS 1300MULTIFUNCTIONAL COUNTERFEIT DETECTOR DORS 1300
EBKM.1300M2.00.00.000-02UM IntBlack
SELECTION OF ILLUMINATION MODE.
Press the SET key of the top keyboard. The main menu image ap­pears in the top left corner of the display. Use the keys ↑ and / or ↓ to select the «M OD E» me nu item . Press t he SET ke y or → to go t o the « MODE» submenu. The «Mode» submenu highlights the menu item corresponding to the curre nt ill umination mod e. Use the ke ys ↓ and / or ↑ in the «Mode» su bme nu to selec t t he required il lum ination mod e. If you w ork wi thout magnification (1x), the following illumination modes are available: «UV+IR»,
«Bottom White + IR», «Top White + IR», «Oblique white + IR», «IR + Anti­Stokes», «IR», «IR Blink». If you work with 20x magnification, the available illumi nation modes a re: «UV +IR», « Bottom White + IR», « Top W hite», «Oblique white», «IR + Anti-Stokes», and «IR». To set the selected illumina-
tion m ode, press the SET key . It re sult s in sw itching on of the requ ired illumination mode accompanied by displaying an information message about the set illumination mode.
SELECTION OF VIDEO SIGNAL SOURCE.
Press the SET key on the top keyboard. The main menu image appears in
the display t op le ft corner. Use t he ke ys ↑ and/or ↓ to select the « VIDEO » menu item. Press the SET key or → to go to the «VIDEO» submenu. Use the keys ↓ and/or ↑ in the «Video» submenu to select the required video signal source. Press the SET key to set the required video signal source. The image from the selected source is brought to the display screen. The first line of the display will s how for several seconds an information mes sage about the selected video signal source («Zoom 1x», «Zoom 20x», «Video input V1»,
«Video input V2» or «Video input IN»).
BRIGHTNESS SETTING.
Press the SET key on the top keyboard. The main menu image appears in the displa y top left c orner. Use the keys ↑ and/or ↓ to select the menu item «Settings». Press the SET key or → to go to the «Settings» submenu. Use the keys ↓ and/or ↑ of the «Settings» submenu to select the «Brightness» item. Press the SET key or → to go to the «Brightness» submenu which ap­pears on the LCD instead of the «Settings» submenu. The current value of the imag e brightness will appear on the screen. Single pressings of the keys ↑ increase the value or ↓ (decr ease the value) set the i mage brightness. The latt er may also be set in a fast way by pressing the key ↑ (↓) and ho lding it down.
To save the set brightness value, press the SET key. Press key ← to return to the top submenu without saving the set value (return to the previous value).
CONTRAST SETTING.
ATTENTION! CONTRA ST I S SE T SE PARATELY F OR E ACH VIDEO SIGNAL SOURCE. THE SET CONTRAST VALUES ARE STORED IN A NONVOLATILE MEMORY AND USED DURING THE NEXT OPERATION WITH THE GIVEN VIDEO SIGNAL SOURCE.
Press SET key on the top keyboard. The main menu image appears in the display t op lef t corner. Use the keys ↑ and/o r ↓ to select th e m enu item «Settings». Press SET key or → to go to the «Settings» submenu. Use the keys ↓ and/or ↑ of the «Settings» submenu to select the item «Contrast». Press SET key or → to go to the «Contrast» submenu which appears on the LCD instead of the «Settings» submenu. The current value of the image contrast will appear on the screen. The required image contrast is set by single pressings of the keys ↑ (increase the value) or ↓ (decrease the value). The contrast may also be set in fast way by pressing the key ↑ (↓) and holding it. To save the set contrast value, press the SET key. Press key ← to return to the top submenu without saving the set value (return to the previous value).
AUDIO SIGNAL SETTING.
ATTENTION: THE SETTINGS FOR ANTI-STOKES MODE ARE SAVED IN THE NONVOLATILE MEMORY AND ARE USED BY DEFAULT.
Press SET key on the top keyboard. The main menu image appears in the display t op lef t corner. Use the keys ↑ and/o r ↓ to select th e m enu item
«Settings». Use the keys ↓ and/or ↑ of the “Settings” submenu to select the «Sound» item. Use the keys ↓ and/or ↑ to c onfirm whether the detection of Ant i-Stokes should be accompanied by the au dio signa l. To save t he set
sound value, press the SET key. Press key ← to return to the top submenu without saving the set value (return to the previous value).
SETTING OF AUTO OFF TIMER.
ATTENTION! SETTINGS OF AN AUTO OFF TIMER ARE STORED IN A NON VOLATI LE M EMORY AND USED FURT HER A S THE DEFAULT ONE S. IF THE OPTION OF AUTO OF F TIMER IS SWITCH ED ON, A APPEARS IN THE LEFT BOTTOM CORNER OF THE SCREEN WHICH INDICATES THE TIME AFTER WHICH THE DETECTOR GOES TO THE STANDBY MODE.
Press the SET key on the top keyboard. The main menu image appears in the display top left corner. Use the keys ↑ and/or ↓ to select the «Settings» menu item. Press the SET key or → to go to the «Settings» submenu. Use the
ATTENTION! BR IGHTN ESS IS SET SEPARAT ELY FOR EACH VIDEO SIGNAL SOURCE. THE SET BRIGHTNESS VALUES ARE STORED IN A NONVOLATILE MEMORY AND USED DURING THE NEXT OPERATION WITH THE GIVEN VIDEO SIGNAL SOURCE.
Page 10
18
19
MULTIFUNCTIONAL COUNTERFEIT DETECTOR DORS 1300MULTIFUNCTIONAL COUNTERFEIT DETECTOR DORS 1300
EBKM.1300M2.00.00.000-02UM IntBlack
keys ↓ and/or ↑ in the «Settings» s ubmenu to select the «Auto o ff timer» ite m. P ress SET key or → to go to t he « Auto off tim er» subm enu whic h appears on the LCD inste ad of the «Settings» subme nu. The value of the current settings of an auto off timer will appear on the screen. Use the keys ↓ and / or ↑ to select the desired time interval of the auto off timer. To save the new value of the time interval for the auto off timer, press the SET key. Press key ← to return to the top submenu without saving the set value (return to the previous value).
SETTING THE LANGUAGE FOR MENU AND INFORMATION MESSAGES.
ATTENTION ! SE TTIN GS OF THE LANGUAG E OF THE MENU AND IN FO RMATIO N MESSA GE S A RE STOR ED IN A NO NVOLAT IL E ME MO RY AN D USED LAT ER O N A S TH E DE FAU LT ON ES. BE CAR EFUL NOT TO SET FOR THE MENU (BY MISTAKE) TH E LAN-
GUAGE YOU FAIL TO UNDERSTAND.
Press the SET key on the top keyboard. The main menu image appears in the display top left corner. Use the keys ↑ and/or ↓ to select the «Settings» menu item. Press the SET key or → to go to the «Settings» submenu. Use the keys ↓ and/or ↑ in the «Settings» submenu to select the «Language» item. Pr ess the SET key or → to g o t o t he «La ngu age » s ubm enu wh ich appears on the LCD instead of the «Settings» submenu. There is highlighted the menu item with the language of an information message used at the given moment. Use the keys↓ and/or ↑ to select the required language of information messages . To sav e, press the SET ke y. Press key ← to return to the top submenu without saving the set value (return to the previous value).
VERIFYING UV MARKS
Place a banknote or a document on the viewing table. Press the UV key () to switch on UV-illumination – the «UV 365 nm» message is displayed.
Examine spect the UV-marks on the banknote (document) surface. The «Fan» method of verification is also permitted when several documents (e.g. banknotes) are placed on the device viewing table stacked in a fan shape. If a simultaneous verification of the IR marks is required, use the tV key to select the zoom 1x image on the display (message «Zoom 1x» shall appear on the display). Then the UV-marks may be viewed directly on the document surface, and the IR marks is on the display screen in the same scale.
CONTROL OF ANTI-STOKES LUMINESCENCE
Place a banknote o r a d ocume nt on the device viewing table thus the fragment of a banknote which consists Anti-stokes luminescent area is under
t he z one of IR l aser. Keep t he a rea of lase r radiation awa y from a di rect sunlight or a direct light of an external source. Otherwise a n observation of Ant i-stokes luminesce nce and a recognition of a luminophore type will be troublesome or even impossible; in this case a message «OVEREXPOS» is appeared on the screen of the device. Press IR i n th e op eration mod e me nu and sele ct A nti-Stokes in t he opened submenu. When the senso r detects an Ant i-stokes response, the device switches off the white light to let a user observes this response as small light point. A message «Mx TYPE» (where a digit «x»means a certain type of lumino­phore) has to appear on the screen.
The verification of Anti-stokes mark is recommended to carry out in the following order: – control the presence of luminophore lighting in the part of banknote with
anti-stokes mark; – compare the color of luminophore lighting with the color indicated in the
banknote security features map; – compare the mark type (М1, М2, М3, etc.) with the mark type indicated in
the banknote security features map.
If an unknown type of luminophore has been detected, a message «UNKNOWN» is appeared on the screen. If there is no Anti-stokes luminescence, a message «NO A/S» is appeared.
VERIFYING MAGNETIC MARK
The verification of magnetic marks is active in all operation modes except Anti-Stokes mode. Pass a part of banknote, which has a magnetic mark, cross the head of induc tive sens or. At the d etection of magnetic ma rk the au dio signal will be generated. To improve the quality of magnetic marks control, for ex ample for verification of wo rn- out ba nkn ote , put the banknote on the magnetic bias area for several seconds.
VERIFYING IR MARKS
Place a banknote or a document on the viewing table. Use the TV key () to select the required zoom. To verify the chart of the IR marks, use zoom 1x. Zoom 20x i s used if i t is ne cessary to study in de tail th e st ructure of the document part visible at IR light. In this case, use the on-screen menu to adjust the required brightness and the contrast of the image on the display. Observe the IR marks on the screen.
VERIFYING IR BLINK MARKS
Place a banknote or a document on the device viewing table. The docu­ment inside the devic e shall avoid direct sunlight or the lig ht from powerful inc ande scen t la mps. Oth erwi se inspection of the mark will be diffic ult or
Page 11
20
21MULTIFUNCTIONAL COUNTERFEIT DETECTOR DORS 1300MULTIFUNCTIONAL COUNTERFEIT DETECTOR DORS 1300
EBKM.1300M2.00.00.000-02UM IntBlack
absolutely impossible. Choose built-in camera with no magnification (1x) as a source of signal. Switch on the verifying IR blink marks mode by pressing the IR key () – the «IR Blink» me ssage sha ll be dis played. I f it is r equired, adjust the required brightness and contrast of the image on the display . The IR blink marks should clearly blink with an interval of about 2 times per second. A repeated pressing of the IR key (message «IR» shall be displayed) switches off the mode.
REFLECTED LIGHT CONTROL
You can use a source of top white light or a source of oblique white light for the reflected light control. Place a banknote or a document on the viewing table of the detector. Use
DL key () for switching on a sou rce o f top white light (a message «TOP WHITE» i s app eared on the screen ) or a source of oblique whit e light (a
message «Oblique white» is appeared on the screen). Examine a banknote (or a document). These mod es are ideal f or control of suc h s ecurity featur es as colo r variable inks and latent imag es. Besides that, you can evaluate a height of printed eleme nts, since high elements are produced remarkable shad ows under oblique light. The detector is used LEDs o f high brightness as sources of whi te light, therefore WE STRONGLY SUGGEST YOU DO NOT LOOK AT SOURCES OF
WHITE LIGHT.
VERIFYING MARKS, PRINTED BY OPTICAL VARIABLE INKS (OVI)
Place a banknote or a document on the device viewing table. To obtain the most obvious change in color, the banknote shall be either in the middle of the viewing table or closer to its back edge. Press the DL key () to switch on the mode of a varia ble color ink inspection (me ssage «Variable color» will be displayed). Monitor the color of the marks printed in a variable color ink. The given mo de is distinguished by a periodical switchi ng over of the angl e of incidenc e of the top white light to the ba nknot e. Due to this, the bank note security mark printed in the variable color ink alternately changes its color . The color of the marks shall change within the limits specified in description of the banknote security feature s. If a mark on the banknote does not chang e its color in compliance with the description, the banknote may be counterfeited, that‘s why the other authenticity marks need verification. Visibility of the mark sh all c hange on b ankno tes o f s om e c ur ren ci es, for examp le, o n eur o banknotes. Next pressing of the DL key switches o ff the white illuminati on source.
CONTROL WITH VERIFYING IN WHITE TRANSMITTED LIGHT AND IR TRANSMITTED LIGHT
Place a banknote or a document on the viewing table. Press the DL key () to switch on the bottom illu mination source ( the «Bottom White + IR» message will be displayed). The sou rce inside the viewing ta ble is emitted simultaneously white light and transmitted IR light; meanwhile the top source of IR light is switched off. The mode is good for verification of the watermarks and imprinted metalized stripes with drawing, micro perforations etc. The screen shows the image obtained at its transmission by IR-rays. It makes possible to examine wate rma rks an d markings on th e m eta lized stripes wi th bet ter contrast;this mode is good for Euro banknotes control. The best way of micro pe rf or at io n control i s 20 x zo om mode . Th e authentic h ol es o f micro perforations are located with a constant pitch, have a round form and the same size; there is not observed any darkeni ng of paper or its thickening at their edges.
SIZE CONTROL
To check the dimensions of the banknotes and the accuracy of the sepa- rate marks located on them, use the control scale applied on a matt glass of the viewing table.
OPERATION WITH EXTERNAL VIDEO MAGNIFIER DORS 1020
SELECT key
23
Fig. 5. Video magnifier DORS 1020
Connect video magnifier DORS 1020 (Fig. 5) to jack V1 or V2 on the device rear panel.
Page 12
22
23
MULTIFUNCTIONAL COUNTERFEIT DETECTOR DORS 1300MULTIFUNCTIONAL COUNTERFEIT DETECTOR DORS 1300
EBKM.1300M2.00.00.000-02UM IntBlack
ATTENTION! BEFORE CONNECTION AND DISCONNECTION OF THE MAGNIFIER CABLE, MAKE SURE THE DEVICE HAS BEEN DISCON­NECTED F ROM TH E POWER SOCKET OR SWI TCHED OFF WITH A POWER SWITCH!
Switch on the device. Press the SELECT key on the top of the magni­fier. The device automatically swi tches to the mode of ima ge examination through the ma gnif ier. Further pressin g of the given key make s po ssible selection of the required illumination source. Magnifier DORS 1020 has three light sources: white, IR a nd UV. Th e message i n the top part of the screen indicates the examination mode.
Long pressing of the TV key () switches the device for viewing with the built-in camera. Returning to operation with the video magnifier requires one more long pressing of the TV key, or pressing of the SELECT key () on the top of the magnifier.
AUTO OFF MODE
The auto off mode is controlled by the on-screen menu (see Fig. 4). If the auto off mo de i s selected, the dev ice automat ical ly goes to the standby mode after the choosen period of time (3, 10, 30 or 60 minutes) since the last pressing of any key. Appearance of a message in left bottom corner of the screen means the auto off mode is turned on; the mes sage shows the period of time after which the detector will go to the standby mode.
When in the standby mode, the power switch indicator continues to light but all the light sources, and the display back light and most of other power consumers of the d evi ce get sw itc hed off. T his ensures lowered po wer consumption.
To leave the standby mode, press any operation key. The device goes to the mode corresponding to the pressed key. If the key ↑ , ↓ , ←, → or the SET key is pressed that control the mode only with the help of the menu, the device goes to the IR-illumination mode.
SWITCHING DEVICE OFF
Press the off power switch key ; here the switch illumination shall go out. It is the user who decides whether to disconnect the power cord from the pow er supply or not. It is wo rth disconnec ting only in case of a lon g-term (more than several days) device standing by.
If it is necessary to install the device on a new place after it was switched off, one shall place the display body in a transportation position. To do it, tur n the dis play around a vertical axis so that the s creen sur face beca me parallel to the device rear wall. Then lower (without any excessive strength) the
display body in a horizontal position with the screen down up to touching the device body. Disconnect the power plug from the power socket. Having done this, one may move the device to a new place.
CARE AND MAINTENANCE
To clean the device surface from dirt, use water-based neutral detergents (for example, the ones for dish washing) or the cleaning compositions on the base of isopropyl alcohol. Remove carefully excess of the detergent or th e cleaning composition from the device.
WARNING! BEFORE CLEANING THE DEVICE SURFACE FROM DIRT,
MAKE SURE THE POWER PLUG HAS BEEN REMOVED FROM THE POWER SOCKET!
WARNING! TO AVOID AN ELECTRIC S HOCK, AVOID INGRESS O F
THE DETERGENT OR THE CLEANING COMPOSITION INSIDE THE DEVICE!
WARNING! WHEN CL EANING TH E SURFACE, USE ONLY A SOFT TISSUE TO APPLY THE DETERGENT OR THE CLEANING COMPOSI­ TION! IT IS PROHIBIT ED TO USE A B RUSH, ASP RAYE R O R A N
AEROSOL SPRAY TO APPLY THE DETERGENT OR THE CLEANING COMPOSITION!
Fluorescent lamps are used in the device as the sources of UV light and bot tom whit e li ght. The device has a built-in system of fluorescent lamps diagnostic which informs the user about a lamp failure and the necess ity to replace it. After a lamp failure, the lamp shall be replaced. As an exception, the device with a failed lamp may be in operation during not more than 8 working hours. Attention! Fluorescent lamps are consumables, and the manufacturer's warranty doesn't cover them.
To replace the fluorescent lamp s, o ne s hall use the lamps of the type installed in the device. To replace UV-lamps, one shall use lamps DORS TL 6W/08 F6T5/BLB. To replace white lamps for viewing table illumination, one shall use lamps DORS TL 6W/08 F6T5/DL.
WARNING! REPLACING OF THE LAMPS MAY BE ACCOMPANIED BY
TOUCHING OF THE METAL CAPS OF THE FLUORESCENT LAMPS
HAVING A SINGLE INSULATION FROM THE CIRCUIT OF THE DEVICE POWER SUPPLY. THEREFORE, IT IS PROHIBITED TO REPLACE THE LAMPS IN THE DEVICE WITH ITS POWER PLUG INSERTED INTO THE POWER SOCKET. ONLY QUALIFIED PERSONNEL SHALL REPLACE THE LAMPS IN THE DEVICE;
Page 13
24 25
30
31
MULTIFUNCTIONAL COUNTERFEIT DETECTOR DORS 1300MULTIFUNCTIONAL COUNTERFEIT DETECTOR DORS 1300
EBKM.1300M2.00.00.000-02UM IntBlack
The message of the system of fluorescent lamps diagnostic appearing on the di splay s creen c ontains th e numbe r of th e faile d lamp, for ex ample: «Chang e UV La mp 2» o r «Change W hite La mp 1». The lamps i n such messages are numbered from the device front panel. Number 1 belongs to the UV-lamp or a white lamp that is the nearest to the device front panel. The most remote UV-lamp has number 3 , the white lamp that is the second from the device front panel has number 2.
UV-LAMP REPLACING PROCEDURE
WARNING! BEFORE REPLACING A LAMP, MAKE SURE THE POWER PLUG HAS BEEN DISCONNECTED FROM THE POWER SOCKET!
ATTENTION! TO AVOID CONTAMINATION OF A GLASS BULB, USE COTTON GLOVES DURING LAMP REPLACEMENT.
1. Place the display body in a transportation position.
2. Place the device on the working table covered by soft cloth.
3. Find a failed UV-lamp by its number.
4. Without any excessive strength, turn the failed lamp around its axis for a
quarter of a turn. Doing it, hold the lamp with two fingers of both hands.
5. Remove the failed lamp together with its protection covers out of the
holders (see Fig. 9).
6. Remove (shift off) the lamp protection covers .
7. Take a new lamp from the package and inspect it: the glass bulb shall be
devoid of scratches and chipping, the lamp cap shall not be damaged, and
the glass bulb surface shall be not contaminated.
27 28 29
Fig. 7. Removing of the
UV-lamp protection cover
UV lamps (two of three)Protection cover catch
UV-lamp holder UV-lamp protection cover
ATTENTION! DO NOT INSTALL IN THE DEVICE A LAMP HAVING
MECHANICAL DAMAGES AND BULB CONTAMINATION!
8. I nsert the lamp into the holders up to the stop. Holding the lamp by two
fingers of both hands, turn it around its axis by a quarter of a turn. Make sure the lamp has fixed in the holders.
9. Put on a protection cover on each lamp holder (no tool is required).
10. Install the device in a working position and make a trial turning on UV light,
make sure that the failure is recovered.
11. Pack the failed lamp and hand it over to a specialized disposal service.
WHITE LAMP REPLACING PROCEDURE
WARNING! BEFORE REPLACING A LAMP, MAKE SURE THE POWER PLUG HAS BEEN DISCONNECTED FROM THE POWER SOCKET!
ATTENTION! TO AVOID CONTAMINATION OF A GLASS BULB, USE COTTON GLOVES DURING LAMP REPLACEMENT.
1. Place the display body in a transportation position.
2. Place the device on the working table covered by soft cloth (as shown on Fig. 8).
3. On the device bottom surface unscrew 6 screws fixing the hatch cover
fo r g ett ing ac ces s t o t he lamps for the vie win g t abl e i llu mination (see.Fig. 8). Remove the hatch cover.
The hatch cover of the lamps for the viewing table illumination. The fixing screws of the hatch cover of the lamps for the viewing table
illumination.
Fig. 8.
The hatch of the lamps for the viewing table illumination
Page 14
26
27MULTIFUNCTIONAL COUNTERFEIT DETECTOR DORS 1300MULTIFUNCTIONAL COUNTERFEIT DETECTOR DORS 1300
EBKM.1300M2.00.00.000-02UM IntBlack
4. Find the failed lamp to be replaced by its number.
5. Without any excessive strength, turn the failed lamp around its axis for a
quarter of a turn. Doing it, hold the lamp with two fingers of both hands.
6. Remove failed lamp from its holders.
7. Take a new lamp from the package and inspect it: the glass bulb shall be
devoid of scratches and chipping, the lamp cap shall not be damaged, and the glass bulb surface shall be not contaminated.
ATTENTION! DO NOT INSTALL INTO THE DEVICE A LAMP HAVING MECHANICAL DAMAGES AND BULB CONTAMINATION!
8. Insert the lamp into the holders up to the stop. Holding the lamp with two
fingers of both hands, turn it around its axis by a quarter of a turn. Make sure the lamp is fixed in the holders.
9. Install the hatch cover on its place, and screw in the screws up to the
stop.
10. Install the device in a working position and make a trial turning on of UV­ radiation; make sure the failure is recovered.
11. Pack the failed lamp and hand it over to a specialized disposal service.
TROUBLESHOOTING
The device fails to switch on (the power switch key doesn’t light).
Check the device connection to the power supply. Fuse F1 (2.0A, 250V) on the CPU power board has failed. Apply to the ser­ vice center.
There is a message «Change UV Lamp 1» (the message may contain either a different number of the lamp or several lamps may be indicated).
A UV illumination fluorescent lamp corresponding to the indicated number
has failed. Apply to the electrician to replace the lamp in compliance with
the abovementioned instruction.
There is a message «Change white Lamp 1» (the message may contain either a different number of the lamp or several lamps may be indicated).
The white fluorescent lamp for illumination of the viewing table correspond­ ing to the indicated number has failed. Apply to the electrician to replace
the lamp in compliance with the above-mentioned instruction.
There is no picture from an external video magnifier / there is no chang­ing over to the corresponding video input by pressing the select key on the magnifier.
The magnifier connector might be not completely inserted in the V1 / V2
jack of the device. Insert the connector into the jack till the stop.
SPECIFICATIONS
Supply voltage.............................................................. 100-240 VAC, 50/60 Hz
Current consumption.................................................... 0.4 - 0.17 A
Weight.......................................................................... 2 .3 kg
Overall dimensions (Width x Depth x Height):
The display is in a transportation position.................... 300 x 170 x 210 mm
The display is lifted by angle 90°................................. 300 x 170 x 324 mm
The display is lifted by angle 120°............................... 300 x 203 x 314 mm
Size of screen active zone........................................... 154 x 86.6 mm
Size of viewing table window....................................... 180 x 109 mm
Total power of UV-radiation source.............................. 18 W
Peak wavelength of UV-radiation................................. 365 nm
Operating range of IR-radiation................................... 800 - 1,000 nm
Two wavelengths at IR blink marks verifying............... 850/940 nm
Video signal standard at connectors IN, OUT.............. ITU R BT.470-7,
peak-to-peak 1 V
Color coding standard.................................................. PAL
Linear magnification on display:
at the use of the built-in cameras................................. 1x / 20x
at the use of the DORS 1020....................................... 22x
Operating temperature................................................. +5 to +40°C
Design and specifications are subject to change without notice for product improvement. The devices presented on the pictures may have some differences in appearance with serial production.
TRANSPORTATION, STORAGE AND DISPOSAL
The device shall be transported in a standard package by sea (in contai- ners ), rai lway ( in clo sed wagons), air (in a pressurized baggage or a cargo compartment) and motor (in an enclosed body or in a container under a water­resistant canopy along the public paved roads) transport. The transportation conditions: temperature – 30 to + 50°C, relative humidity up to 95 % without water condensation at +25°C, atmosphere pressure 84 to 107 kPa (630 to 800 mm Hg). The device sha ll be store d in the packag e, in a hea ted warehouse a t temperature +10 to +25°C, at a relative air humidity not exceeding 80%. The device meets the requirements of the European Union RoHS directive which results in decreas e of the environmental pollution by hazardous sub­stances.
Page 15
28
MULTIFUNCTIONAL COUNTERFEIT DETECTOR DORS 1300
EBKM.1300M2.00.00.000-02UM IntBlack
ATTENTION! BE FORE DISPOSAL, REMOVE AL L THE FIVE FLUO­ RESCENT LAMPS FROM THE DEVICE FOLLOWING ITEMS 1 - 6 OF
THE SECTIONS «UV-LAM P R EPLACEMENT P R OC EDUR E» AN D «W HITE LAM P R EPLAC EME NT PR OCE DURE» . T HE RE MOV ED LAMPS SHALL BE HANDE D OVER TO A SPECIALIZED DISPO SAL SERVICE.
The device without its lamps may be disposed as a domestic waste.
SUPPORT AND WARRANTY
The manufacturer guarantees a 12-month operation of the device since the moment of its sale (or since the moment of its release if the warranty card does not contain the sale date). The manufacturer is obliged to repair the failed de­vice if the user has observed all the requirements of the given service manual. Fai lure of the fluorescent lamps is not a gu arantee e vent. Nei ther is a guarantee even t the device damage result ing from an improper use o f the device, its falling and applying an excessive physical strength.
Loading...