Dormont C200Na BFG User Manual

ES-A-C200Na
Job Name ________________________________________________Contractor ______________________________________________
Job Location ______________________________________________Approval ________________________________________________
Engineer__________________________________________________Contractor’s P.O. No. ______________________________________
Approval__________________________________________________Representative __________________________________________
Features
• Extremely Compact Design
• 70% Lighter than Traditional Designs
• Groove Fittings Allow Integral Pipeline Adjustment
• Patented Bi-Link Check Provides Lowest Pressure Loss
• Unmatched Ease of Serviceability
• Available with Grooved Butterfly Valve Shutoffs
• Available for N Pattern Installations
• Replaceable Check Disc Rubber
C200Na BFG
Ames product specifications in U.S. customary units and metric are approximate and are provided for reference only. For precise measurements, please contact Ames Technical Service. Ames reserves the right to change or modify product design, construction, specifications, or materials without prior notice and without incurring any obligation to make such changes and modifications on Ames products previously or subsequently sold.
The Colt C200Na Double Check Valve Assemblies are used to prevent backflow of pollutants, that are objectionable but not toxic, from entering the potable water supply system. The Colt C200Na may be installed under continuous pressure service and may be subjected to backpressure. The Colt C200Na consists of two independently operating check valves, two shutoff valves, and four test cocks. For use in non-health hazard applications.
Specifications
The Colt C200Na Double Check Valve Assemblies shall consist of two independent Bi-Link Check modules within a single housing, sleeve access port, four test cocks and two drip tight shutoff valves. Bi-Link Checks shall be removable and serviceable, without the use of special tools. The housing shall be constructed of 304 (Schedule 40) stainless steel pipe with groove end connections. Bi-Link Checks shall have reversible elastomer discs and in operation shall produce drip tight closure against the reverse flow of liquid caused by backpressure or backsiphonage. Assembly shall be a Colt C200Na as manufactured by the Ames Company.
Colt
TM
Series C200Na
Double Check Valve Assemblies
Sizes: 21⁄2" – 6" (65 – 150mm)
www.amesfirewater.com
Dimensions — Weights
Configurations
• Horizontal
• Vertical up
• “N” pattern horizontal
Materials
• Housing & Sleeve: 304 (Schedule 40) Stainless Steel
• Elastomers: EPDM, Silicone and Buna ‘N’
• Bi-Link Checks: Noryl
®
, Stainless Steel
• Check Discs: Reversible EPDM
• Test Cocks: Bronze Body Nickel Plated
• Pins & Fasteners: 300 Series Stainless Steel
• Springs: Stainless Steel
SIZE (DN) DIMENSIONS WEIGHT
G H I J P C200NaBFG
in. mm in. mm in. mm in. mm in. mm in. mm lbs. kgs.
21⁄265 297⁄8759 22 559 1415⁄16379 813⁄16223 9 229
64 29
3803011⁄16779 223⁄4578 157⁄16392 93⁄16233 91⁄2241
67 30
4 100 3115⁄16811 24 610 161⁄4412 915⁄16252 10 254
84 38
6 150 433⁄161097 333⁄4857 1911⁄16500 131⁄16332 101⁄2267
157 71
Note: For 21⁄2" – 6" horizontal/vertical installation, send for literature ES-A-C200/C200N.
Noryl® is a registered trademark of General Electric Company.
H
I
J
G
P
G
H
J
I
P
C200NaBFG
C200Na
SIZE (DN) DIMENSIONS WEIGHT
G H I J P C200Na
NRS OSY
in. mm in. mm in. mm in. mm in. mm in. mm lbs. kgs. lbs. kgs.
21⁄265 291⁄16738 22 559 151⁄2393 813⁄16223 93⁄16234 123 56 133 60
380301⁄4768 223⁄4578 171⁄8435 93⁄16233 101⁄2267 144 65 158 72 4 100 33 838 24 610 181⁄2470 915⁄16252 113⁄16284 184 83 184 83 6 150 16 406 51⁄2140 443⁄41137 131⁄16332 15 381
314 142 336 152
Note: For 21⁄2" – 6" horizontal/vertical installation, send for literature ES-A-C200/C200N.
Available Models
Suffix:
NRS - non-rising stem resilient seated gate valves
OSY - UL/FM outside stem and yoke resilient
seated gate valves
BFG - UL/FM grooved gear operated butterfly valves
with tamper switch
*OSY FxG - Flanged inlet gate connection and grooved
outlet gate connection
*OSY GxF - Grooved inlet gate connection and flanged
outlet gate connection
*OSY GxG - Grooved inlet gate connection and grooved
outlet gate connection
Available with grooved NRS gate valves - consult factory* Post indicator plate and operating nut available - consult factory* *Consult factory for dimensions
Pressure — Temperature
Temperature Range: 33°F – 110°F (5°C – 43°C) Maximum Working Pressure: 175psi (12.06 bar)
Approvals
For additional approval information please contact the factory or visit our website at www.amesfirewater.com
Capacity
UL/FM Certified Flow Characteristics Flow characteristics collected using butterfly shutoff valves. See literature S-Colt-200/300 for gate valve flow characteristics
* = Rated Flow ** = UL Tested
N - Pattern
B64.51047
IMPORTANT: INQUIRE WITH GOVERNING AUTHORITIES
FOR LOCAL INSTALLATION REQUIREMENTS
kPa psi
96 14 83 12 69 10 55 8 41 6 28 4 14 2
00
0 50 100 150 200 250 300 350 gpm 0 190 380 570 760 950 1140 1330 lpm
7.5 15 fps
2.3 4.6 mps
kPa psi
83 12 69 10
55 8 41 6 28 4 14 2
00
0 100 200 300 400 500 gpm 0 380 760 1140 1520 1900 lpm
7.5 15 fps
2.3 4.6 mps
21/2" (65mm)
3" (80mm)
*
**
kPa psi 138 20
110 16
83 12
55 8
28 4
00
0 100 200 300 400 500 600 700 800 gpm 0 380 760 1140 1520 1900 2280 2660 3040 lpm
7.5 15 fps
2.3 4.6 mps
4" (100mm)
*
*
kPa psi
83 12 69 10
55 8
41 6
28 4
14 2
00
0 300 600 900 1200 1500 gpm 0 1140 2280 3420 4560 5700 lpm
7.5 15 fps
2.3 4.6 mps
6" (150mm)
*
**
**
**
N
N
N
N
For additional information, visit our web site at: www.amesfirewater.com
ES-A-C200Na 0836 ©Ames Fire & Waterworks 2008
www.amesfirewater.com
A Division of Watts Water Technologies, Inc.
USA: Backflow- 1427 N. Market Blvd • Suite #9 • Sacramento, CA 95834 • T: 916-928-0123 • F: 916-928-9333
Control Valves- 18550 Hansen Road • Houston, TX 77075 • T: 713-943-0688 • F: 713-944-9445
Canada: 5435 North Service Rd. • Burlington, ONT. L7L 5H7• T: 905-332-4090 • F: 905-332-7068
Loading...