Series 4000BLT
Portable Hydrant Backflow
ES-A-4000BLT
Features
• Built-In support leg is adjustable in
the field, no matter the installation.
Eliminates assembly from sitting
ectly in field or from being stacked
dir
on wood
• Dual thread connections, inside 2
FNPT and outside 3" MNPT threaded
on each inlet and outlet, allows the
user a variety of connection alternatives
• Large flow capacity-rated at over 500
gpm with less than 14psi loss per
ASSE, USC and AWWA standards for
Reduced Pressure Zone Assemblies
• No field assembly required, eliminates
leaks, fouls, and improper assembly
• Factory assembled and tested.
• Varieties of end connection accessories are available to fit on-site
requirements
• Corrosion resistant 304 stainless steel
body for long life field dependability.
• Portable-lightweight design makes
device easily transportable between
job sites
Materials
Body & cover: SST
Check assemblies: Eng. Plastic & SST
RV assembly: Eng. Plastic & SST
Lid coupler: DI/CI
4000BLT
1
⁄2"
Series 4000BLT Portable Hydrant Backflow is for use in protection of potable
water from a fire hydrant or other nonpermanent installations where flow is in
one direction only and the possibility of a cross-connection exists. Ideal for
use with client's existing hydrant meter hookup. Series 4000BLT Portable
Hydrant Backflow is designed and manufactured to provide long-term service
with minimal maintenance. When maintenance is required, it can be performed
easily at the hydrant or at any other convenient location. As an alternative to
repair by the utility, Ames can arrange a maintenance program to fit the needs
of the utility.
Specifications
Series 4000BLT Portable Hydrant Backflow is designed to protect the potable
water system in accordance with national plumbing codes and water authority
requirements, by preventing backflow through the fire hydrant during site construction phase. Water flows through the pre-tested Reduced Pressure Zone
Assembly. The Series 4000BLT consists of two independently operating,
spring loaded cam-check valves with a hydraulically operated differential pressure relief valve located between and below the cam-checks. When normal
flow exists, both checks ar
checks called the zone, is at least 2psi lower than the inlet pr
tion of normal flow occurs, the differential pressure relief valve will automatically open and discharge to maintain the zone at least 2psi lower than the inlet
pressure. Series 4000BLT comes standard with an adjustable mounting bracket,
sturdy relief valve shield, dual thread connections and other options. Standard
valve shown with 3" MNPT and 2
e open and the pr
1
⁄2" FNPT each end.
essur
e in the ar
ea between the
e. If cessa
essur
-
Job Name ________________________________________________ Contractor ____________________________________________
Job Location ______________________________________________ Approval ______________________________________________
Engineer__________________________________________________ Contractor’s P.O. No. ______________________________________
Approval__________________________________________________ Representative __________________________________________
te and are provided for reference only. For precise measurements, please contact Ames Technical Service. Ames reserves the right
y units and metric are a
Ames product specifications in U.S.
to change or modify product design, construction, specifications, or materials without prior notice and without incurring any obligation to make such changes and modifications on Ames products previously or
subsequently sold.
customar
pproxima
www
.amesfir
ewater.com
Approvals
Series 4000BLT Portable Hydrant Backflow
meets the design requirements of most
national standards. Due to the portability of
the unit, there are no national approvals
available.
Options
Inlet modules
• 3" female hydrant thread
• 3" male hydrant thread
1
•
⁄2" female hydrant thr
2
•21⁄2" male hydrant thread
•21⁄2" male NPT thread
• Customer specified
Outlet modules
• 3" gate w/female hose thread
• 3" gate w/male hose thread
•21⁄2" gate w/female hose thread
1
⁄2" gate w/male hose thread
•2
• 3" gate valve only, 3" MNPT thread
•21⁄2" gate valve only, 21⁄2" FNPT thread
• Customer specified
Foot modules
• Uneven surface saddle (supplied
standard with unit)
• Flat surface adapter
• Customer Specified
ead
alve hose
Relief v
1st cam-check assembly
Relief valve hose
Mounting bracket saddle
Series 4000BLT Flow Characteristics
kPa psi
138 20
103 15
69 10
34 5
201/8"
Groove coupler
2nd
cam-check
assembly
Relief valve
assembly
alve shield
Relief v
Mounting bracket rod adjustment
*
Assemble outlet
module here If
required
/4"
1
/4 =
1
8
/4"
1
/16 =
3
9
21 3
00
0 100 200 300 400 500 600 gpm
0 380 760 1140 1520 1900 2280 lpm
5 7.5 10 15 fps
1.5 2.3 3 4.6 mps
Flow Rate
oximate headloss at the UL rated flow.
*Appr
MODEL
SIZE / INLET SIZE / OUTLET
4000BLT 21⁄2" FNPT / 3" MNPT 21⁄2" FNPT / 3" MNPT
.com
A Division of W
atts Regulator Company
www
.amesfir
ewater
1427 North Market Blvd. • Suite #9 • Sacramento, CA 95834 • Phone: 916-928-0123 • Fax: 916-928-9333
ES-A-4000BLT 0312 ©Ames Co. 2003 Printed in U.S.A.