For Residential and Commercial Applications
ES-D-Supr-Safe
Job Name ________________________________________
Job Location ______________________________________
Engineer _________________________________________
Approval ___________________________________
SuprSafe®
Stainless Steel
Gas Connectors
Durable, naturally corrosion-resistant 304 stainless steel gas
connectors for indoor or outdoor stationary appliance applications.
Features and Specifications
• Tubing: Annealed, 304 stainless steel (ASTM A240)
• Flare nuts: Brass or plated steel
• Adapters: Brass or plated steel
• Optional coating: Heavy-duty, antimicrobial, hot-dipped gray PVC
1
(for
⁄2" OD (21 series) and 5⁄8" OD (31 series only). Coating will not
hold a flame.
• Approved for indoor/outdoor use with stationary gas
appliances/equipment
• Temperature rating of connector with adapters: -40°F to 150°F
• Temperature rating with valves: -40°F to 125°F
• 100% factory leak tested
• When installing a new appliance or when an existing
appliance is moved to a new location a NEW gas
connector must be used per manufacturer’s installation
instructions and per product standards ANSI Z21.24/CSA
6.10 and ANSI Z21.75/CSA 6.27
• Designed for occasional movement after installation. Repeated
bending, flexing or extreme vibration must be avoided. Normal
operation of a clothes dryer, rooftop HVAC unit or SIMILAR
OUTDOOR APPLIANCE DOES NOT constitute extreme
vibration or movement
Contractor ________________________________________
Approval _________________________________________
Contractor's P.O. No. _______________________________
Representative ____________________________________
SKU _____________________________________________
Quality Flared end
adapters: create a
metal to metal seal
to ensure integrity in
critical applications
304 stainless steel:
durable, corrosionresistant construction
Design Certifications & Approvals
• ANSI Z21.24/CSA 6.10 – Connectors for Gas Appliances
• ANSI Z21.75/CSA 6.27 – Connectors for Outdoor Appliances and
Manufactured Homes
• City of New York – MEA #376-92-M
• Approved by the Commonwealth of Massachusetts Board of State
Examiners of Plumbers and Gas Fitters – connector length may not
exceed 48"
WARNING
All installations must completely comply with all Dormont manufacturing company warnings
and instructions, national, state and local codes and all applicable ansi standards.
Dormont product specifications in U.S. customary units and metric are approximate and are provided for reference only. For precise
measurements, please contact Dormont Technical Service. Dormont reserves the right to change or modify product design, construction,
specifications, or materials without prior notice and without incurring any obligation to make such changes and modifications on Dormont
products previously or subsequently sold. Refer to the owner's manual for warranty information.
Exclusive No-Neck
Design: Increase
Tubing Flexibility
10, 20 and 30 Series

Minimum Flow Capacity
Connector Minimum Flow Capacity – For Natural Gas (per ANSI Z21.24/CSA 6.10 & ANSI Z21.75/CSA 6.27)
Straight Length Capacity – BTU per Hr 0.64 SG., 1000 BTU per Cu. Ft. at 0.5 inch Water Column Pressure Drop
Configuration ConnECtor LEngtH [inCHES]
SERIES
10
20
30
Nominal OD Nominal ID 12 18 24 30 36 48 60 72
in in
3
⁄
8
1
⁄
2
5
⁄
8
1
⁄
4
3
⁄
8
1
⁄
2
in in in in in in in in
48,000 43,800 40,000 36,400 33,400 28,300 24,900 23,100
102,000 93,100 85,000 77,100 71,000 60,500 53,200
180,000 164,200 150,000 136,000 125,000 106,000 93,200
Connector Minimum Flow Capacity – For LP Gas (per ANSI Z21.24/CSA 6.10 & ANSI Z21.75/CSA 6.27)
Straight Length Capacity – BTU per Hr 1.55 SG., 2500 BTU per Cu. Ft. at 0.5 inch Water Column Pressure Drop
Configuration ConnECtor LEngtH [inCHES]
SERIES
10
20
30
Nominal OD Nominal ID 12 18 24 30 36 48 60 72
in in
3
⁄
8
1
⁄
2
5
⁄
8
1
⁄
4
3
⁄
8
1
⁄
2
in in in in in in in in
76,800 70,080 64,000 58,240 53,440 45,280 39,840 36,960
163,200 148,960 136,000 123,360 113,760 96,800 85,120
288,000 262,720 240,000 217,600 200,000 169,600 194,120
Applications
49,100
86,000
78,560
137,600
Indoor
• Range
• Dryer
• Water Heater
• Gas Fireplace
• Garage Heater
• Wall Heater
• Tankless Water Heater
• Furnace
• Space Heaters
Outdoor
• Rooftop Units
• Outdoor Dryer
• Stationary Outdoor Grills
• Gas Fire Pits
Manufactured Home
• Mobile Home Gas Meter
• Cross-over Gas
Connection Kits
NOTICE
The minimum flow capacity values in the charts are at 0.5" w.c. pressure drop (inlet pressure
minus outlet pressure). If your gas system has more available pressure drop then a general
rule of thumb approximate calculation is as follows:
Minimum Flow Capacity @ your pressure drop = Square Root (your pressure drop/0.5) x value
from chart
Example: What is the approximate minimum flow capacity (natural gas) of the Dormont 30
Series x 24" @ 1" wc pressure drop?
Answer: Square Root (1/0.5) x 150,000 = 212,132 BTU/hr
USA: Tel: (800) 367-6668 • Fax: (724) 733-4808 • Dormont.com
Canada: Tel: (905) 332-4090 • Fax: (905) 332-7068 • Dormont.ca
Latin America: Tel: (52) 81-1001-8600 • Fax: (52) 81-8000-7091 • Dormont.com
ES-D-Supr-Safe 1610 © 2016 Dormont