dormakaba EAD RMS0003 intergration manual

Integration Manual for the HIDprox RFID Reader Module FCC ID NVI-RMS0003
About this manual
Validity
This manual describes the HIDprox RFID Reader Module into hosts, e.g. KABA B-web 93 00
This manual is written exclusively for specialists. The descriptions in this manual are intended for personnel trained by the manufacturer. The
information in this manual cannot substitute the product training. The contents of this manual is intended for use by the following groups of people:
Project manager
Project manager who is responsible for the system and entrusted with project planning and realization.
Fitter
Person specialized in mounting and installation. Person who has an adequate technical training and sufficient experience and who has been authorized by the manufacturer after completing the training on the product.
Service technician
Specialist for initial set-up and maintenance of the installation. Person who has an adequate technical training and sufficient experience and who has been authorized by the manufacturer after completing the training on the product.
Network administrator
Realizes the set-up of the device within the network and makes sure that the devices are accessible within the network.
Software partner
Specialists for connecting the system to the user software by defining operating and booking sequences, programming the customer applications and setting the parameters of the devices.
NOTICE! For reasons of device safety, some of the activities might only be carried out by the
SERVICE PERSON.
Only persons of the groups "Fitter" and "Service technician" have the status of a SERVICE PERSON according to DIN EN 60950-1:2006.
Contents and purpose The contents are limited to the assembly and installation of the hardware.
ESD (electro static discharge) protective measures
CAUTION
Danger for electronic components due to electrostatic discharge. Improper handling of printed circuit boards or components can cause damages that
lead to complete failures or sporadic errors.
During installation and repair of the device, the ESD protective measures must be
considered.
Please consider the following guidelines before the installation or maintenance of the device:
Always carry an ESD antistatic wristband when dealing with electronic components.
Connect one part of the wristband with a discharge socket or an unvarnished grounded metal component. This way, static charges are discharged from your body securely and effectively.
Only touch the printed circuit boards at the edges. Do not touch the printed circuit
board itself or the connector.
Place all dismantled components on an anti-static surface or in an anti-static
container.
Avoid contact between printed circuit boards and your clothing. The wristband only
protects the printed circuit boards against electrostatic discharge from the body, but there is still a risk of damage through electrostatic discharge from your clothing.
Transport and dispatch dismantled modules only in electrostatically shielded
protective bags.