Dorf Jovian Installation Instructions Manual

Distributed by: Dorf Clark Industries Limited ABN 23 004 394 923
IS898C(04/09)
(SIDE 1 OF 2)
1
2
3
4
5
6
9
11
12
13
16
17
20
14
15
10
Mixer Connection End
18
Inlet Connection End
19
Installation
1) From fixing pack fit base seal (12) into groove in base of mixer (11). Screw studs (13) into underside of mixer body (11).
2)
3)
4)
Flexible Tail Inlet Connections: Connect the flexible tails (19) to the hot and cold isolating stop taps, hand tighten the connecting nut (18) until rubber cone contacts the sealing face of the connection end, then tighten a further one turn to provide a watertight joint. Important: Flexible tails must not be kinked, twisted or in tension when installed. (Minimum Bend Radius:− 50mm) Do not install flexible tails where subject to ultra violet light.
Important Information
Mixer is fitted with a 7 L/min flow regulated aerator insert.
Not suitable for gravity feed systems.
All pipework must be thoroughly flushed prior to installation, as foreign materials may block the flow regulating device and reduce the flow of water. Note: Aerator insert housing must be retightened to prevent removal by hand.
*
*
*
Isolating stop taps must be fitted to the hot & cold water supply connections. (Part No. 842018C − Mini cistern 1/4T)
*
Flexible Tail Mixer Connections: Apply suitable lubricant to ’O’rings (20). Fit flexible tail (19) (with red indication) into hole marked with a Red Dot on underside of mixer body (11). Hand tighten the tail, ensuring the ’O’ring (20) has fully entered the sealing bore to provide a watertight joint. Fit other flexible tail (with blue indication) into remaining hole in a similar manner.
Insert the inlet connection end (18) of each flexible tail (19) through the hole in the deck. Place mixer over deck hole, fit gasket (15) and fixing plate (16) over studs (13) then screw on fixing nuts (17). Position mixer as required then tighten fixing nuts (17) using spanner (14) provided.
PLUMBERS INSTALLATION INSTRUCTIONS
JOVIAN − SINK MIXER
WATER EFFICIENT TAPWARE
(NOMINAL FLOW RATE = 7 L/min)
Hot and cold water inlet pressures should be equal. Inlet pressure range : 150−1000 kPa
IMPORTANT
Pressure & Temperature Requirements.
Deck thickness : 45mm maximum
Deck Requirements
Maximum hot water temperature : 80 C.
Tap body hole (in deck) : 34−36mm
New Regulation:− 500 kPa maximum operating pressure at any outlet within a building. (Ref. AS/NZS 3500.1−2003, Clause 3.3.4)
Replacing Cartridge
1) Turn off hot and cold water supplies at isolating stop taps.
2) Carefully remove plug (2). Using 2.5mm allen key (3) loosen screw (4) and remove handle (1). Unscrew cap (5) taking care not to damage the decorative finish. Unscrew
nut (6) then lift out the old cartridge (9).
3) Ensure inside face of mixer body (11) is clean. Check that seals (10) are in position in base of new cartridge (9).
Fit new cartridge (9) into mixer body, taking care that two lugs on base of cartridge (9) fit into mating holes in mixer body (11).
4) Screw on nut (6). Important:− Nut (6) should be tightened to a torque of 10 Nm.
5) Replace cap (5), tightening by hand. Fit handle (1) taking care that it is pushed fully down, tighten screw (4) and replace plug (2).
6) Turn on isolating stop taps and check operation.
Distributed by: Dorf Clark Industries Limited ABN 23 004 394 923
IS898C(04/09)
(SIDE 2 OF 2)
Adjusting the HOT LIMIT RING (ANTI−SCALD STOP RING)
The cartridge fitted in this mixer has been factory pre−set to deliver the maximum available hot water temperature. To use the ANTI−SCALD feature adjust the cartridge as follows:−
Carefully remove plug (2). Using 2.5mm allen key (3) loosen screw (4) and remove handle (1). Unscrew cap (5) taking care not to damage the decorative finish. (See details on side 1 of this sheet.)
To remove the Hot Limit Ring (7) from the cartridge (9), use a small thin flat bladed screwdriver and carefully lever in an upwards direction.
Rotate the Ring (7) in a clockwise direction then refit the Ring (7) onto the cartridge (9). Note:− Start by rotating the Ring (7) in small increments, then check the hot water temperature with the mixer handle in the fully open maximum hot water position. The Ring (7) can be removed & repositioned until the desired maximum hot water temperature is achieved.
Ensure the Ring (7) is pushed fully down onto the cartridge (9), then replace cap (5), tightening by hand. Fit handle (1), taking care that it is pushed fully down, tighten screw (4) and replace plug (2).
PLUMBERS ADJUSTMENT INSTRUCTIONS
JOVIAN − SINK MIXER
WATER EFFICIENT TAPWARE
(NOMINAL FLOW RATE = 7 L/min)
Adjusting the WATER VOLUME LIMIT SCREW
The cartridge fitted in this mixer has been factory pre−set to deliver the maximum flow of water when the mixer handle is in the fully open position. Important Note:− This Sink Mixer is already fitted with a 7.0 L/min flow regulated aerator insert. Lower flow rates may not be suitable for connection to some Instantaneous Gas Water Heaters, some Tempering Valves, some Solar Water Heaters & some Thermostatic Mixing Valves. Check with the manufacturers of these products. However, the flow of water may be reduced further by adjusting the cartridge as follows:−
Carefully remove plug (2). Using 2.5mm allen key (3) loosen screw (4) and remove handle (1). Unscrew cap (5) taking care not to damage the decorative finish. (See details on side 1 of this sheet.)
Using a small thin flat bladed screwdriver, adjust screw (8) in an anti−clockwise direction. Note:− Start by rotating the Screw (8) in small amounts then check the flow of water with the mixer handle in the fully open position. Readjust the screw until the desired water flow is achieved.
Replace cap (5), tightening by hand. Fit handle (1), taking care that it is pushed fully down, tighten screw (4) and replace plug (2).
7
9
8
9