P312:Call a Poison center or doctor/physician if you feel unwell.
P302+P350-IF ON SKIN: Gently wash with plenty of soap and water
P301+P330+P331-IF SWALLOWED: rise mouth. Do NOT induce vomiting
P305+P351+P338 IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if
present and easy to do. Continue rinsing.
Storage:
None
Disposal
P501: Dispose of contents/container in accordance with local/national regulations
Hazards not otherwise classified (HNOC)
Not Applicable
Other information
No information available.
GHS02 GHS05 GHS06
Report No.:STR15069200S Page 3 of 10
Page 4
Shenzhen SEM.Test Technology Co., Ltd.
1/F, Building A, Hongwei Industrial Park, Liuxian 2nd
Road, Bao'an District, Shenzhen, P.R.C. (518101)
Safety Data Sheet
3. COMPOSITION/INFORMATION ON INGREDIENTS
Chemical characterixation: Mixtures
Description:
Product: Consisting of the following components.
Common Chemical Name
Concentration
(%)
Lead 70 7439-92-1 231-100-4
Sulfuric acid 20 7664-93-9 231-639-5
Epoxy resins 10 61788-97-4 ----
Note: CAS number is Chemical Abstract Service Registry Number.
N/A=Not apply.
CAS Number EC No.
4. FIRST-AID MEASURES
First aid measures
Eye Contact Rinse thoroughly with plenty of water, also under the eyelids. If symptoms persist, call a
physician.
Skin Contact Remove contaminated clothing and shoes. Wash skin with soap and water. In the case of skin
irritation or allergic reactions see a physician.
Inhalation Move to fresh air. If symptoms persist, call a physician.
Ingestion Do NOT induce vomiting. Drink plenty of water. If symptoms persist, call a physician.
Most important symptoms and effects, both acute and delayed
Swallowing Do not induce vomiting. Get medical attention.
Most Important Symptoms/Effects
Indication of any immediate medical attention and special treatment needed
Notes to Physician Treat symptomatically
No information available.
5. FIRE-FIGHTING MEASURES
Suitable Extinguishing Media
CO2, dry chemical powder, water spray.
Unsuitable Extinguishing Media:No information available.
Specific Hazards Arising from the Chemical
Formation of toxic gases is possible during heating or in case of fire.
In case of fire, the following can be released:
Carbon monoxide(CO)
Carbon dioxide
Report No.:STR15069200S Page 4 of 10
Page 5
Other irritating and toxic gases.
Hazardous Combustion Products
Carbon oxides.
Explosion Data
Sensitivity to Mechanical Impact No
Sensitivity to Static Discharge No
Protective Equipment and Precautions for Firefighters
As in any fire, wear self-contained breathing apparatus pressure-demand, MSHA/NIOSH (approved or
equivalent) and full protective gear. For example: Wear self-contained respiratory protective device. Wear
suitable protective clothing and eye/face protection.
Special hazards arising from the substance or mixture:
Battery may burst and release hazardus decomposition products when exposed to a fire situation. Lead Acid
Batteryies contain flammable electrolyte that may vent, ignite and produce sparks when subjected to high
temperature(>150℃), When damaged or abused(e.g. mechanical damage or electrical overcharging); may
burn rapidly with flare-burning effect; may ignite other batteries in clothes proximity.
Shenzhen SEM.Test Technology Co., Ltd.
1/F, Building A, Hongwei Industrial Park, Liuxian 2nd
Road, Bao'an District, Shenzhen, P.R.C. (518101)
Safety Data Sheet
6. ACCIDENTAL RELEASE MEASURES
Personal precautions, protective equipment and emergency procedures
Personal Precautions Avoid contact with eyes.
Refer to section 8 for personal protective equipment. Ensure adequate ventilation. Remove all sources of
ignition.
Evacuate personnel to safe areas.
Environmental precautions
Environmental Precautions Refer to protective measures listed in Sections 7 and 8.
Absorb with liquid-binding material (sand, diatomite, acid binders, universal binders, sawdust).
Dispose contaminated material as waste according to item 13.
Methods and material for containment and cleaning up
Methods for Containment Prevent further leakage or spillage if safe to do so.
Methods for Cleaning up Use personal protective equipment. Dam up. Cover liquid spill with sand, earth or
other Non combustible absorbent material. Pick up and transfer to properly labeled containers. Clean
contaminated surface thoroughly.
7. HANDLING AND STORAGE
Precautions for safe handling
Handling Handle in accordance with good industrial hygiene and safety practice. Avoid contact with skin,
eyes and clothing. Wear personal protective equipment.
Wash thoroughly after handling. Use this material with adequate ventilation.
The product is not explosive.
Conditions for safe storage, including any incompatibilities
Report No.:STR15069200S Page 5 of 10
Page 6
If the Lithium-ion Battery is subject to storage for such a long term as more than 3 months, it is recommended
to recharge the Lithium-ion Polymer Battery periodically.
3 months: -10 ~+40 , 45 to 85%RH℃℃
And recommended at 0 ~+35 for long period storage.℃℃
The capacity recovery rate in the delivery state (50% capacity of fully charged) after storage is assumed to be
80% or more.
The voltage for a long time storage shall be 12V~13V range.
Do not storage Lithium-ion Battery haphazardly in a box or drawer where they may short-circuit each other
or be short-circuited by other metal objects.
Keep out of reach of children.
Do not expose Lithium-ion Polymer Battery to heat or fire. Avoid storage in direct sunlight.
Do not store together with oxidizing and acidic materials.
Keep ignition sources away- Do not smoke.
Store in cool, dry and well-ventilated place.
Incompatible Products
Shenzhen SEM.Test Technology Co., Ltd.
1/F, Building A, Hongwei Industrial Park, Liuxian 2nd
Road, Bao'an District, Shenzhen, P.R.C. (518101)
None known.
Safety Data Sheet
8. EXPOSURE CONTROLS AND PERSONAL PROTECTION
Control parameters
Ingredients with limit values that require monitoring at the workplace:
1309-60-0 Lead peroxide
TLV (USA) 0.02mg/m3
MAK (Germany) 0.1mg/m3
Other Exposure Guidelines Vacated limits revoked by the Court of Appeals decision in AFL-CIO v.
OSHA, 965 F.2d 962(11th Cir., 1992).
Appropriate engineering controls
Engineering Measures Showers
Eyewash stations
Ventilation systems
Use adequate general or local exhaust ventilation to keep airborne concentrations below the permissible
exposure limits. Ensure adequate ventilation.
Individual protection measures, such as personal protective equipment
Eye/Face Protection:
Tightly sealed goggles
Body protection:
Protective work clothing.
Skin protection:
Protective gloves
Material of gloves:
Report No.:STR15069200S Page 6 of 10
Page 7
The selection of the suitable gloves does not only depend on the material, but also on further marks of quality
and varies from manufacturer to manufacturer. As the product is a preparation of several substances, the
resistance of the glove material can not be calculated in advance and has therefore to be checked prior to the
application.
Penetration time of glove material:
The exact break trough time has to be found out by the manufacturer of the protective gloves and has to be
observed.
Respiratory Protection No protective equipment is needed under normal use conditions. If exposure limits
are exceeded or irritation is experienced, ventilation and evacuation may be required.
Hygiene Measures Handle in accordance with good industrial hygiene and safety practice.
Shenzhen SEM.Test Technology Co., Ltd.
1/F, Building A, Hongwei Industrial Park, Liuxian 2nd
Road, Bao'an District, Shenzhen, P.R.C. (518101)
Safety Data Sheet
9. PHYSICAL AND CHEMICAL PROPERTIES
Form: prismatic
Physical
State
Change in condition:
pH, with indication of the concentration Not determined.
Melting point/freezing point Not determined.
Initial boiling point and Boiling range: Not determined.
Flash Point Not determined.
Evaporation rate Not determined.
Flammability (solid, gas) Not determined.
Upper/lower flammability or explosive limits Not determined.
Vapor Pressure:
Vapor Density:
relative density: Not determined.
Solubility in Water: Not determined.
Color: Black
Odour: Odourless
Odor Threshold: No information available
Not determined.
Not determined.
Solubility in other solvents Not determined.
n-octanol/water partition coefficient Not determined.
Auto-ignition temperature Product is not self-igniting.
Decomposition temperature Not determined.
Odout threshold Not determined.
Evaporation rate
Report No.:STR15069200S Page 7 of 10
Not determined.
Page 8
Viscosity Not determined.
Other Information No further relevant information available.
Shenzhen SEM.Test Technology Co., Ltd.
1/F, Building A, Hongwei Industrial Park, Liuxian 2nd
Road, Bao'an District, Shenzhen, P.R.C. (518101)
Safety Data Sheet
10. STABILITY AND REACTIVITY
Reactivity: Stable under recommended storage and handling conditions (see section 7, Handling and
storage).
Chemical stability:
Thermal decomposition/conditions to be avoided: No decomposition if used according to specifications.