NOTE: THESE INSTRUCTIONS MUST BE READ AND UNDERSTOOD BEFORE
INSTALLING, COMMISSIONING, OPERATING OR SERVICING EQUIPMENT.
THIS WATER HEATER IS FOR USE ON GROUP H NATURAL GAS (2
LPG (3
REQUIRED WITHIN DOCUMENT IS FOUND RELATING TO SPECIFIC GAS TO BE FIRED
BEFORE FIRING HEATER.
THIS WATER HEATER COMPLIES WITH ALL RELEVANT EUROPEAN DIRECTIVES.
PUBLICATION NO. 500001138
ISSUE ‘A’
OCTOBER 2013
RD
FAMILY) I3+ (DR-RS 105 I3P). PLEASE ENSURE RELEVANT INFORMATION
This manual describes how to install, service and use the DR-RS water heater.
A DR-RS water heater is a gas-fired closed water heater with a fan in the air
supply. Depending on the water heater type, the chimney connections are
parallel or concentric. Installation types possible with this water heater are C
and C33. The information in this manual is applicable to water heater types: DRRS 25, DR-RS 40, DR-RS 65, DR-RS 85 and DR-RS 105.
The manner of construction and features of the water heater are in conformance
with the European standard for gas-fired storage water heaters for the
production of domestic hot water (EN 89). The water heaters are compliant with
the European Directive for Gas Appliances and have the right to bear the
CE mark.
Warning
Read this manual carefully before starting up the water heater. Failure to
read the manual and to follow the printed instructions may lead to personal
injury and damage to the water heater.
Warning
Whenever there is a smell of gas:
No naked flames! No smoking!
Avoid causing sparks! Do not use any electrical equipment or switch, i.e. no
telephones, plugs or bells!
13
1.3Regulations and
documents
Shut off the mains gas supply!
Open windows and doors!
Warn occupants and leave the building!
After leaving the building, alert the gas distribution company or your installer.
Gas Safety Installations and Use Regulations 1998, (As amended). It is law
that all gas appliances are installed by competent persons, in accordance with
the above regulations. Failure to install appliances correctly could lead to
prosecution. It is in your own interest, and that of safety, to ensure that this law
is complied with.
The installation of the boiler MUST be in accordance with the relevant
requirements of the Gas Safety Regulations, Building Regulations, IEE
Regulations and the Water Supply (water fittings) Regulations.
The installation should also be in accordance with any relevant requirements of
the HSE, local gas region and local authority and the relevant recommendations
of the following documents:
Instruction manual DR-RS7
Page 8
1
Introduction
gis
British Standards
•BS 6891: Specification for installation of low pressure gas pipework of up to
28 mm (R1) in domestic premises (2nd family gas). For larger installations
see IGE/UP/2 below.
•BS 6798: Specification for installation of gas-fired boilers of rated input not
exceeding 70 kW net.
•BS 6644: Specification for installation of gas-fired hot water boilers of rated
inputs between 60 kW and 2 MW (2nd and 3rd family gases).
•BS 6700: Specification for design, installation, testing and maintenance of
services supplying water for domestic use within buildings and their
curtilages.
•BS EN 806-2: Specification for installations inside buildings conveying water
for human consumption. Part 2: Design.
•BS 5546: Specification for installation of hot water supplies for domestic
purposes, using gas-fired appliances of rated input not exceeding 70 kW.
•BS 5440: Installation and maintenance of flues and ventilation for gas
appliances of rated input not exceeding 70 kW net (1st, 2nd and 3rd family
gases). Part 1: Flues. Part 2: Ventilation.
Institute of Gas Engineers and Managers Publications
•IGE/UP/1 Soundness testing and purging of industrial and commercial gas
installations.
•IGE/UP/1A Soundness testing and direct purging of small low pressure
industrial and commercial natural gas installations.
•IGE/UP/2 Gas installation pipework, boosters and compressors on industrial
and commercial premises.
•IGE/UP/10 Installation of gas appliances in industrial and commercial
premises. Part 1: flued appliances.
CIBSE Publications:- "CIBSE Guide"
Section B4 : Water Service Systems.
1.4Target groupsThe three target groups for this manual are:
•(end) users;
•installers;
•service and maintenance engineers.
Symbols on each page indicate the target groups for whom the information is
intended. See Table 1.1.
Table 1. 1 Target group symbols
SymbolTarget group
(End) user
g
Installer
i
Service and maintenance engineer
s
8Instruction manual DR-RS
Page 9
Maintenance
gis
1.5MaintenanceA service should be carried out at least once a year, both on the water side and
on the gas side. Maintenance frequency depends, among other things, on the
water quality, the average burning time per day and the set water temperature.
n Remark
To determine the correct maintenance frequency, it is recommended to
arrange for the service and maintenance engineer to check the water heater
on both the water and gas side, three months after installation. Based on this
check, the best maintenance frequency can be determined.
n Remark
Regular maintenance extends the service life of the water heater.
Both the end user and the service and maintenance engineer are responsible
for regular maintenance. They will need to establish clear agreements on this.
n Remark
If the water heater is not regularly maintained, the warranty will become void.
1.6Forms of notationThe following notation is used in this manual:
n Remark
Important information
cNote
Ignoring this information can lead to the water heater being damaged.
Warning
Failure to carefully read this information may lead to danger of personal
injury and serious damage to the water heater.
Instruction manual DR-RS9
Page 10
1
Introduction
gis
1.7Overview of this
document
Table 1. 2 Contents of document
ChapterTarget groupsDescription
2 Functioning of the water
heater
3Installation
4 Filling and draining
Table 1.2 provides an overview of the contents of this document.
This chapter describes how the water heater functions.
gis
This chapter describes the installation activity to be completed
is
before you actually start up the water heater. Instructions are
also provided for the installation and/or service and
maintenance engineer on converting the water heater to other
types of gas.
This chapter describes how to fill and drain the water heater.
gis
5 Controls
6 Status of the water heater
7 Starting up and shutting
down
8 Troubleshooting
gis
gis
gisgis
gis
This chapter describes the water heater’s control panel and
how to use it.
This chapter describes the status (mode or condition) that the
water heater may have and possible actions to take.
This chapter describes how to start-up the water heater and
how to shut it down for a brief or long period of time. The
general heating cycle of the water heater is also described.
This chapter is mainly intended for the installer and the service
and maintenance engineer. It describes water heater errors.
These errors are indicated on the display. A troubleshooting
table of possible causes and solutions is provided. End users
may also refer to this chapter for additional information about
the water heater.
9 Maintenance
s
This chapter sets out the maintenance tasks to be carried out
during a service.
n Remark
If the water heater is not regularly maintained, the warranty
will become void.
10Instruction manual DR-RS
Page 11
gis
2Functioning of the
water heater
2.1IntroductionTopics covered in this chapter:
•Functional description of the water heater;
•The water heater’s heating cycle;
•Protection for the water heater;
•Safety of the installation.
Instruction manual DR-RS11
Page 12
2
Functioning of the water heater
gis
2.2Functional
description of the
water heater
Figure 2.1 shows a cut-away view of the water heater.
IMD-0240
Legend:
(1) flue gas discharge
(2) air supply
(3) fan
(4) top box
(5) anodes
(6) flue tubes
(7) flue baffles
(8) hot water tank
(9) insulation layer
12Instruction manual DR-RS
(10) air restrictor
(11) cleaning opening
(12) cold water inlet
(13) drain valve
(14) combustion chamber with air
distribution plate
(15) bar burners/burner tray
(16) hot water outlet
(17) control thermostat
(18) air pressure switch
(19) high-limit thermostat
Figure 2.1 Cut-away view of the water heater
(20) high-limit thermostat sensor
(21) safety thermostat
(22) safety thermostat sensor
(23) frost thermostat
(24) burner control
(25) frost thermostat sensor
(26) control thermostat sensor
(27) flame probe
(28) pilot burner
(29) spark igniter
(30) gas control
Page 13
gis
The water heater’s heating cycle
In this water heater, the cold water enters the bottom of the it via the cold water
inlet (12). The heat of combustion is transferred to the water through the
combustion chamber (14) and flue tubes (6). The heated tap water leaves the
heater via the hot water outlet (16). Once the water heater is completely filled
with water, it remains constantly under water supply pressure. As hot water from
the water heater is consumed, it is continuously replenished with cold water.
The air required for combustion is forcibly delivered to the combustion chamber
by the fan. The gas required for combustion flows into the manifold via the gas
control (30). The DR-RS 105 has a different gas control (see box). There are
orifices in the manifold. The gas enters the bar burners (15) via these orifices.
The bar burners together form the burner tray. As the gas is injected into the bar
burners, the primary air required for combustion is also drawn in from the
combustion chamber
steps. The pilot flame is first ignited by a spark igniter. This pilot flame then
ensures the complete ignition.
The flue gases generated by this combustion are led through the flue tubes (6).
There are flue baffles (7) fitted inside the flue tubes. These slow down the flue
gas exhaust, improving the heat transfer efficiency. The flue gases leave the
water heater via the top box (4). A different top box is used on the DR-RS 85
and 105 (see box). Below the burner tray there is an air distribution plate (14),
that also serves as a radiation shield. When condensation forms, the water runs
off to the siphon via the air distribution plate.
The insulation layer (9) prevents heat loss. The inside of the hot water tank is
enamelled to protect against corrosion. The anodes (5) provide additional
protection.
(1)
. The ignition of the gas/air mixture takes place in two
2.3The water heater’s
heating cycle
2.4Protection for the
water heater
The water heater is controlled by the burner control (24) and the control
thermostat (17) or frost thermostat (23). The control thermostat and frost
thermostat both independently measure the water temperature (T
water heater’s heating cycle is activated as soon as T
specified threshold value (T
for the water heater, see paragraph 6.2 Operating modes. If the water heater is
in the ’OFF mode’ (frost protection), then this value is determined by the frost
thermostat (threshold value = 20°C). If the water heater is in the ’ON mode’, then
the threshold value is selectable via the control thermostat (40°C - 70°C).
As soon as T
close and the burner control will register a heat demand. The gas control (30)
will open and the gas will mix with the air it draws in. This mixture is ignited by
the spark igniter (29) and the water becomes heated. A soon as T
, the thermostat will open once more. The heat demand will cease and the
T
set
burner control will stop the heating cycle.
The thermostats have a certain margin both when closing and opening. We refer
to this margin as the hysteresis. The hysteresis cannot be adjusted.
The burner control monitors the water temperature by means of thermostats
and ensures a safe combustion. This is achieved by:
•the Water temperature protection;
•the flame probe;
•the Pressure switch.
falls below T
water
). The value for T
set
, the relevant thermostat (control or frost) will
set
depends on the status chosen
set
falls below the
water
water
water
). The
exceeds
1. The narrow opening in the orifices accelerates the gas flow. This causes a partial vacuum. The
effect of this partial vacuum is to draw the air into the flow (the Venturi effect).
Instruction manual DR-RS13
Page 14
2
2.4.1Water temperature protection
Table 2. 1 Temperature protection
ProtectionDescription
Functioning of the water heater
By means of the frost, high-limit and safety thermostats, the burner control
monitors three temperatures related to safety. Table 2.1 explains the operation
of the thermostats with sensors.
gis
Frost thermostatIf the frost thermostat sensor (25) detects a temperature of 20°C or lower, the
High-limit thermostatIf the high-limit thermostat sensor (20) detects a temperature greater than
Safety thermostatIf the safety thermostat sensor (22) detects a temperature greater than 93°C,
2.4.2flame probe
2.4.3Pressure switch
water heater’s heating cycle will start. See paragraph 2.3 The water heater’s
heating cycle.
84°C, the high-limit thermostat will open. The heat demand will cease and the
burner control will stop the heating cycle until the high-limit thermostat closes
again. At that moment, the burner control resets the water heater and the
heating cycle resumes. The high-limit safeguard serves to prevent
overheating and/or excessive formation of scale in the water heater.
the safety thermostat will open. The heat demand will cease and the burner
control will immediately stop the heating cycle. A lockout error of the burner
control takes place. This must be manually reset, before the water heater can
be put back into operation.
To ensure that no gas can flow when there is no combustion, an flame
probe (27) has been fitted. The burner control uses this rod for flame detection,
by means of ionisation detection. The burner control cuts in immediately, as
soon as it detects that gas is flowing, but there is no flame.
The pressure switch guarantees the discharge of the flue gases and the supply
of air. The default position of the pressure switch is open. If there is sufficient
pressure difference across the air restrictor (10), the air pressure switch (18) will
close. However, in the event of a fault, the pressure switch will be tripped open
and the heating cycle will be interrupted.
Table 2.2 shows the trip point per water heater.
Table 2. 2 Pressure switch trip points
AppliancePressure differential [Pa]
ClosingOpening
DR-RS 25> 200 < 170
DR-RS 40> 270 < 240
DR-RS 65> 255< 225
DR-RS 85> 610< 580
DR-RS 105> 220< 190
14Instruction manual DR-RS
Page 15
gis
2.5Safety of the installation
2.5.1Unvented installation
2.5.2Vented installation
2.5.3Temparature and Pressure valve (T&P valve)
Safety of the installation
With an unvented installation, an expension valve and expansion vessel prevent
excessive pressure in the water heather. This prevents damage of the water
heater. A non-return valve prevents excessive pressure in the water supply
system. This valve also prevents water from flowing backwards from the heater
into the cold water supply system. The pressure reducing regulates the water
supply pressure to a normal operating pressure of 3.5 bar. The components are
fitted to the cold water pipe. See paragraph 3.6.1 Cold water side.
With a vented installation, excess pressure is taken up by the open water tank.
The level of the water determines the working pressure which may not exceed
8 bar.The installation must also be fitted with an open vent from the hot water
pipe. Ideally the vent pipe should be linked to a separate tundish/drain or else
to the cold water storage tank. A safety valve should also be fitted to the water
heather. See paragraph 3.6.3 Hot water side.
A T&P valve is mandatory in an 'unvented' installation.
A T&P valve monitors the water pressure in the water heater and the water
temperature at the top of it. If the pressure in the water heater becomes
excessive (> 7 bar) or the water temperature is too high (>97°C), the valve will
open. The hot water will immediately flow out of the heater. Because the water
heater is under water supply pressure, cold water will automatically flow into it.
The valve remains open until the unsafe situation has been averted. A
connecting point for a T&P valve is standard on the water heater. See paragraph
3.6.3 Hot water side
2.6Indicators and
Alarms
2.6.1Volt Free Contacts
Volt free contacts are supplied as standard to give remote indication/alarm of
'normal run' and 'lockout'. The 'lockout' indication includes shut down due to
operation of the safety thermostat, loss of flame and failure to ignite.
2.7OptionsThe heaters can be supplied with the following additional variations, either
ready fitted or for site fitting:
2.7.1LPG
The heaters can be supplied adjusted for use on propane or butane, see section
3.12. It is most important that the heater is correctly adjusted for the gas to be
fired.
2.7.2Unvented Supply
The heaters can be supplied with a purpose designed and sized unvented kit
comprising pressure reducing valve, non-return valve, expansion vessel,
expansion relief valve and pressure/temperature relief valve, to enable the
heater to be coupled directly to the mains water. For details see 2.5.1, 2.5.3 and
3.6.
Instruction manual DR-RS15
Page 16
2
Functioning of the water heater
gis
2.7.3Top to Bottom Circulation
In order to give enhanced temperature control to aid compliance with the HSE
guidance and the DHss Code of Practice for 'The Control of Legionellae in
Health Care Premises', a pump circulation kit can be supplied comprising 230
volt single phase pump, non-return valve, pipe work and sufficient fittings to
contact between the hot water flow and the bottom connection. For details see
section 3.5 of this manual.
16Instruction manual DR-RS
Page 17
is
3Installation
Warning
The installation should be carried out by an approved installer in compliance
with the general and local regulations imposed by the gas, water and power
supply companies and the fire service.
The water heater may only be installed in a room which complies with the
requirements stated in national and local ventilation regulations.
Refer also to paragraph 1.3 Regulations and documents.
3.1IntroductionThis chapter describes the installation activities to be carried out before the
water heater may be started up, namely:
•Packaging;
•Environmental conditions;
•Technical specifications;
•Water connections, Unvented;
•Water connections, Vented;
•Gas connection;
•Air supply and flue gas discharge;
•Electrical connections;
•Checking the supply pressure and burner pressure;
•Conversion to a different gas category.
n Remark
Starting up the water heater is described in chapter 7 Starting up and
shutting down.
3.2PackagingTo avoid damaging the water heater, remove the packaging carefully. We
recommend unpacking the water heater at or near its intended location.
cNote
The water heater may only be manoeuvred in an upright position. Take care
that the water heater is not damaged after unpacking.
3.3Environmental
conditions
The DR-RS water heater is a room-sealed water heater. Installation types
possible with this water heater are C13 and C33. This makes it possible to install
the water heater in either a closed or an open boiler room.
Instruction manual DR-RS17
Page 18
3
Installation
is
3.3.1Humidity and ambient temperature
The boiler room must be frost-free or be protected against frost. Ta bl e 3. 1
shows the environmental conditions that must be adhered to, for correct
functioning of the electronics present in the water heater to be guaranteed.
Table 3. 1 Humidity and ambient temperature specifications
Humidity and
Humiditymax. 90% RH at +40°C
Ambient temperatureFunctional: 0 ≤ t ≤ 60°C
3.3.2Maximum floor loading
In connection with the water heater’s weight, take account of the maximum floor
loading, see Tab le 3 . 2.
Table 3. 2 Weight specifications related to maximum floor loading
Weight of the water heater filled with water
DR-RS 25DR-RS 40DR-RS 65DR-RS 85DR-RS 105
554 kg 557 kg 560 kg 585 kg 585 kg
3.3.3Working clearances
For access to the water heater it is recommended that the following
clearances are observed (see Figure 3.2):
•AA: around the water heater’s control column and cleaning openings: 100
cm.
•BB: around the water heater itself: 50 cm.
•Above the water heater (room to replace the anodes):
-100 cm if using fixed anodes or
-50 cm if using flexible anodes.
ambient temperature
18Instruction manual DR-RS
Page 19
is
Environmental conditions
If the available clearance is less than 100 cm, flexible magnesium anodes
may be ordered from Hamworthy, the installer / supplier.
n Remark
When installing the water heater, be aware that any leakage from the it
and/or connections can cause damage to the immediate environment or
floors below the level of the boiler room. If this is the case, then the water
heater should be installed above a wastewater drain or in a suitable metal
leak tray.
The leak tray must have an appropriate wastewater drain and must be at
least 5 cm deep with a length and width at least 5 cm greater than the
diameter of the water heater.
Figure 3.1 Working clearances
Instruction manual DR-RS19
Page 20
3
Installation
is
3.4Technical specifications
DR-RS 25, 40, 65
The water heater is supplied without accessories. Check the dimensions and
other specifications for the accessories to be used, based on Figure 3.2 and
2. If using a blank plate instead of a burner pressure regulator, it is assumed that the burner pressure is equal to
the supply pressure. In practice however, the burner pressure will be lower.
2. If using a blank plate instead of a burner pressure regulator, it is assumed that the burner pressure is equal to
the supply pressure. In practice however, the burner pressure will be lower.
(2)
(1)
mbar----22.0
kg/h2.23.45.57.98.9
DR-RS
40
DR-RS
65
DR-RS
85
DR-RS
105
3.5Installation diagramFigure 3.3 shows the water and gas connection diagrams for unvented and
vented installations. The following paragraphs, describing the connections in
detail, make reference to these diagrams
Instruction manual DR-RS23
Page 24
3
Legend
a pressure-reducing valve
(mandatory whenever the
mains water pressure exceeds
8 bar)
b expansion vessel (mandatory)
c T&P valve (mandatory)
ca) safety valve
d stop valve (recommended)
e non-return valve (mandatory)
ea) non-return valve
f circulation pump (optional)
g drain valve
h gas valve (mandatory)
i stop valve (mandatory)
j temperature gauge
(recommended)
k top to bottom recirculation
pump (optional)
l top box
m hot water draw-off points
n condensation drainage
o expension valve (mandatory)
p water tank
q float valve
r 3-way venting valve ()
s overflow pipe
a cold water supply
b hot water outlet
c circulation pipe
d gas supply
e flue gas discharge
Installation
UNVENTED
d
f
e
d
h
d
c
g
VENTED
is
m
e
l
j
c
d
k
e
d
o
n
e
l
c
i
d
k
e
d
b
eia
j
b
a
IMD-0066
s
r
b
i
m
p
a
i
dfed
i
IMD-0065
Figure 3.3 Installation diagrams
c
g
d
h
24Instruction manual DR-RS
Page 25
is
3.6Water connections,
Unvented
3.6.1Cold water side
3.6.2Top to bottom recirculating pump
Water connections, Unvented
See a in Figure 3.3.
1. Fit an approved stop valve i on the cold water side as required by
regulations.
Refer also to paragraph 1.3 Regulations and documents.
2. Fit an approved pressure-reducing valve a.
3. Fit a non-return valve e and an expansion vessel b.
4. Fit an expension valve o and connect the discharge to a drain via tundish.
You can connect a top to bottom recirculation pump to prevent stratification of
the water in the water heater.
1. Fit a pipe (Ø 22 mm), a stop valve d and a top to bottom recirculation
pump k.
2. Fit non-return valve e.
3. Fit stop valves i.
3.6.3Hot water side
See b in Figure 3.3.
n Remark
Insulating long hot water pipes prevents unnecessary energy loss.
1. Optional: Fit a temperature gauge j to be able to check the temperature of
the tap water.
2. Fit the T&P valve c.
3. Fit a stop valve i in the hot water outlet pipe, for use when servicing.
3.6.4Drain valve
1. Fit the standard drain valve supplied g.
2. If a circulation pipe is to be fitted, then refer to paragraph 3.6.5. Otherwise,
fit the sealing nut and gasket supplied with the drain valve. See Figure 3.4.
3.6.5Circulation pipe
See c in Figure 3.3 and Figure 3.4.
c
If an immediate flow of hot water is required at draw-off points, a circulation
pump can be installed. This improves comfort and reduces water wastage.
1. Fit a circulation pump f of the correct capacity for the length and resistance
of the circulation system.
2. Fit a non-return valve e behind the circulation pump to guarantee the
direction of circulation.
3. Fit two stop valves d for service purposes.
4. Connect the circulation pipe to the T-piece on the drain valve g. See
Figure 3.4.
IMD-0122
Figure 3.4 Drain valve
Instruction manual DR-RS25
Page 26
3
3.6.6Condensation drainage
3.7Water connections,
Vented
3.7.1Cold water side
3.7.2Top to bottom recirculating pump
Installation
is
Fit a small drainpipe with fall to the appropriate connection for condensation
drainage at the rear of the water heater and connect this further to the water
drainage pipe.
cNote
All piping behind the siphon must be condensation-resistant.
See a in Figure 3.3.
1. Fit an approved stop valve i on the cold water side between the water
tank p and the water heater, as required by regulations. Refer also to
paragraph 1.3 Regulations and documents.
You can connect a top to bottom recirculation pump to prevent stratification of
the water in the water heater.
1. Fit a pipe (Ø 22 mm), a stop valve d and a top to bottom recirculation
pump k.
2. Fit non-return valve e .
3. Fit stop valves i.
3.7.3Hot water side
See b in Figure 3.3.
n Remark
Insulating long hot water pipes prevents unnecessary energy loss.
1. Fit the safety valve ca.
2. Optional: fit a temperature gauge j to be able to check the temperature of
the tap water.
3. Fit a stop valve i in the hot water outlet pipe, for use when servicing.
4. If a circulation pipe is to be fitted, then refer to paragraph 3.7.4.
3.7.4Circulation pipe
See c in Figure 3.3.
If an immediate flow of hot water is required at draw-off points, a circulation
pump can be installed. This improves comfort and reduces water wastage.
1. Fit a circulation pump f of the correct capacity for the length and resistance
of the circulation system.
2. Fit a non-return valve ea downstream the circulation pump to guarantee the
direction of circulation.
3. Fit two stop valves d for service purposes.
4. Connect the circulation pipe to the T-piece on the drain valve g. See
Figure 3.4.
26Instruction manual DR-RS
Page 27
is
3.8Gas connection
Gas connection
Warning
Gas installation may only be carried out by an authorised installer in
compliance with the general regulations imposed by the gas company.
Refer also to paragraph 1.3 Regulations and documents.
cNote
Make sure that the diameter and length of the gas supply pipe are large
enough to supply sufficient capacity to the water heater.
See d in Figure 3.3.
1. Fit a gas valve h in the gas supply pipe.
2. Blow the gas pipe through before use, to be sure it is clean.
3. Close the gas valve.
4. Fit the gas supply pipe to the gas control.
Warning
Check for leaks after fitting.
3.9Air supply and flue
gas discharge
3.9.1Introduction
3.9.2Fitting flue gas discharge and air supply for DR-RS 25, 40, 65
Warning
The installation should be carried out by an authorised installer, in
compliance with the general and local regulations imposed by gas, water
supply and power supply companies and the fire service. Refer also to
paragraph 1.3 Regulations and documents.
The connections for the air supply and the flue gas discharge of the DR-RS 25,
40 and 65 differ from those of the DR-RS 85 and 105.
The DR-RS water heaters are approved for installation types C13 and C33.
This manual describes these installation types. If an explanation of other types
of installation is required, please contact Hamworthy.
cNote
Hamworthy prescribes the use of a roof or wall-mounted concentric terminal,
of a type approved for the water heater.
The following requirements must be fulfilled:
•The maximum chimney length allowed (A+B+C) is 7 metres.
•The maximum number of 45° or 90° bends allowed is 2.
•If you make use of horizontal piping, then this must slope towards the water
heater with a minimum of 5 mm per metre running length!
•Make sure that the chimney discharges into an area where this is permitted
for this category of water heater.
See Figure 3.5 Wall flue terminal and Figure 3.6 Roof flue terminal for example
installations.
1. No other wall flue terminal is permitted. The wall flue terminal set can be ordered using this article number from Hamworthy, the
manufacturer or from a trade supplier
(1)
Part No.DR-RS 25: 562702039
DR-RS 40: 562702040
DR-RS 65: 562702041
ConstructionConcentric
Flue gas discharge Thick-walled aluminium with lipped sealing ring
Air supplyThin-walled galvanised sheet steel
DR-RS 40: Ø100 mm
DR-RS 65: Ø130 mm
Air supplyDR-RS 25: Ø125 mm
DR-RS 40: Ø150 mm
DR-RS 65: Ø200 mm
IMD-0060
28Instruction manual DR-RS
Page 29
is
Air supply and flue gas discharge
3.9.2.2Concentric roof flue terminal for DR-RS 25, 40, 65
Hamworthy heating limited prescribes the roof flue terminal (installation type
C33) as specified in Tab l e 3. 7 .
Figure 3.6 Roof flue terminal
Tab le 3.7 Concentric roof flue terminal specifications
ItemDescription
Roof flue terminal
Tube materialConstructionConcentric
Tube diametersFlue gas discharge DR-RS 25:Ø80 mm
1. No other roof flue terminal is permitted. The roof flue terminal set can be ordered using this article number from Hamworthy, the
manufacturer or from a trade supplier
(1)
Part No.DR-RS 25: 562702043
DR-RS 40: 562702044
DR-RS 65: 562702045
ConstructionConcentric
Flue gas discharge Thick-walled aluminium with lipped sealing ring
Air supplyThin-walled galvanised sheet steel
DR-RS 40: Ø100 mm
DR-RS 65: Ø130 mm
Air supplyDR-RS 25: Ø125 mm
DR-RS 40: Ø150 mm
DR-RS 65: Ø200 mm
IMD-0061
Instruction manual DR-RS29
Page 30
3
a air supply
b flue gas discharge
Installation
is
3.9.3Fitting flue gas discharge and air supply for DR-RS 85 and 105
The air supply duct a and flue gas discharge duct b of the DR-RS 85 and 105
emerge separately from the top box, as shown in Figure 3.7. They must be
connected to the concentric wall flue terminal (see Figure 3.8) or roof flue
terminal (see Figure 3.9) via a transition piece.
a
b
Figure 3.7 Parallel connections on DR-RS 85 and 105
n Remark
Hamworthy prescribes the use of a roof or wall-mounted concentric terminal,
of a type approved for the water heater. See paragraphs 3.9.3.1 Concentric
wall flue terminal for DR-RS 85 and 105 and 3.9.3.2 Concentric roof flue
terminal for DR-RS 85 and 105. Use of an incorrect roof or wall-mounted
terminal can cause the installation to malfunction.
The following requirements must also be fulfilled:
•The maximum chimney length allowed (A+B+C) is 7 metres.
•The maximum number of 45° or 90° bends allowed is 2.
•If you make use of horizontal piping, then this must slope towards the water
heater with a minimum of 5 mm per metre running length!
•The transition piece, to convert the air supply and flue gas discharge from
parallel to concentric, must be placed immediately before the roof or wall flue
terminal.
•The duct length of the air supply must be approximately the same as that of
the flue gas discharge chimney.
•Make sure that the chimney discharges into an area where this is permitted
for this category of water heater.
See Figure 3.8 Wall flue terminal and Figure 3.9 Roof flue terminal for example
installations.
IMD-0252
30Instruction manual DR-RS
Page 31
is
Air supply and flue gas discharge
3.9.3.1Concentric wall flue terminal for DR-RS 85 and 105
Ta bl e 3 .8 shows the wall flue terminal prescribed by Hamworthy (installation
type C13).
IMD-0226
Figure 3.8 Wall flue terminal
Tab le 3.8 Specifications for transition piece and concentric wall flue terminal
ItemDescription
Wall flue terminal and transition
(1)
piece
Tube materialConstructionParallel
Tube diametersFlue gas dischargeØ130 mm
1. No other wall flue terminal is permitted. The wall flue terminal set can be ordered using this article number from Hamworthy, the
manufacturer or from a trade supplier
Part No.562702042
Construction:Concentric
Flue gas dischargeThick-walled aluminium with lipped sealing ring
Air supplyThick-walled aluminium with lipped sealing ring
Air supplyØ130 mm
Instruction manual DR-RS31
Page 32
3
Installation
is
3.9.3.2Concentric roof flue terminal for DR-RS 85 and 105
Hamworthy heating limited prescribes the roof flue terminal (installation type
C33) as specified in Table 3.9.
IMD-0239
Figure 3.9 Roof flue terminal
Table 3. 9 Specifications for transition piece and concentric roof flue terminal
ItemDescription
Roof flue terminal and
transition piece
Tube materialConstructionParallel
Tube diametersFlue gas dischargeØ130 mm
1. No other roof flue terminal is permitted. The roof flue terminal set can be ordered using this article number from Hamworthy, the
manufacturer or from a trade supplier
32Instruction manual DR-RS
(1)
Part No.562702046
ConstructionConcentric
Flue gas dischargeThick-walled aluminium with lipped sealing ring
Air supplyThick-walled aluminium with lipped sealing ring
Air supplyØ130 mm
Page 33
is
3.10 Electrical connections
3.10.1Introduction
3.10.2Preparation
Electrical connections
Warning
The installation should be carried out by an approved installer in compliance
with the general and local regulations imposed by the gas, water and power
supply companies and the fire service.
Refer also to paragraph 1.3 Regulations and documents.
Topics covered in this paragraph:
•3.10.2 Preparation;
•3.10.3 Mains;
Figure 3.10 shows a front view of the electrical connection block. Ta bl e 3. 1 0
shows the associated connections.
Tab le 3.10 Electrical connection block DR-RS
Mains powerVolt Free contact
Lock out
NL
123456789
Close Control
Thermostat
A
NOPNCNOPNC
Corex Anode
power
Time clock
Volt Free contact
power
Normal run
Time clock
connection
ALNLNLNLL
131415161718192021
Instruction manual DR-RS33
Page 34
3
Installation
is
3
Figure 3.10 Connection block (connections 1 through 10 explained in
Table 3.10)
In preparation, first remove the protective cover from the control column:
•Undo the 4 screws 1 and remove the protective cover 2 from the electrical
section. The connection block 3 is now visible.
2
1
IMD-0362
n Remark
Refer to A Electrical diagram DR-RS for the connection of electrical
components.
3.10.3Mains
The water heater is supplied without a power cable and isolator.
n Remark
In order to receive electrical power, the water heater has to be connected to
the mains by means of a permanent electrical connection. A double pole
isolator with contacts gaps of at least 3 mm must be fitted local to the water
heater. The power cable must have cores of at least 3 x 1.0 mm2.
1. Feed the power cable through the metric strain relief on the top of the control
column.
2. Connect earth (
terminals 1 through 3 of the connection block as indicated in Table 3.10.
3. Tighten the strain relief so that the cable is clamped.
4. If you do not need to make any more connections, then fit the protective
cover back on the control column.
A), phase (L
) and neutral (N) of the power cable to
1
34Instruction manual DR-RS
Page 35
is
3.11 Checking the supply
pressure and burner
pressure
Checking the supply pressure and burner pressure
5. Connect the power cable to the isolator.
Warning
Leave the water heater disconnected until you are ready to start it up.
cNote
Before you start up the water heater and/or begin to check the supply
pressure and burner pressure, you must first fill the water heater. Please
refer to paragraph 4.2 Filling the water heater for filling instructions.
cNote
Before starting up for the first time and following conversion, you must
always check the supply pressure and burner pressure. If necessary,
adjust these to be certain of optimum performance of the water heater.
cNote
The easiest way to check the gas pressures is by using two pressure
gauges. This procedure assumes that these two gauges are available.
Legend:
a burner pressure regulator
b burner pressure control cap
c burner pressure control
adjusting screw
d blank plate
e supply pressure test nipple
f gas control
g burner pressure test nipple
If the water heater must operate on a gas category other than that for which the
water heater has been set up at the factory (see rating plate), the water heater
will first have to be converted. See paragraph 3.12 Conversion to a different gas
category.
Gas control valve for DR-RS 25, 40, 65 and 85
e
c
f
g
a
b
d
IMD-0256
Figure 3.11 Gas control valve
Instruction manual DR-RS35
Page 36
3
Installation
is
Gas control valve for DR-RS 105
e
f
c
a
Figure 3.11 Gas control valve(Continued)
To check the supply pressure and burner pressure, proceed as follows:
1. Disconnect the water heater from the power supply. See paragraph
7.3.2 Isolate the water heater from the power supply.
2. There are two test nipples on the gas control (Figure 3.11):
-supply pressure test nipple e;
-burner pressure test nipple g.
Sealing screws are located inside the test nipples. Loosen both sealing
screws by a few turns. Do not loosen them completely; this makes them
difficult to tighten again.
3. Connect a pressure gauge to burner pressure test nipple g.
g
IMD-0257
n Remark
All gas pipes should be vented and free of leakage.
4. Open the gas supply.
5. Connect a pressure gauge to test nipple e.
6. Switch on the power to the water heater using the isolator on the water
heater.
7. Set the control thermostat to the highest position and start the water heater
running by putting the On/Off switch to position I.
8. The heating cycle will start and the burner tray will ignite after a short time.
9. After the burner tray has ignited, wait for approximately 1 minute before you
start reading the dynamic pressures.
10. Use the pressure gauge to read the supply pressure at the test nipple e.
Refer to Table 3.5.
n Remark
Consult the mains gas supply company if the supply pressure is not correct.
36Instruction manual DR-RS
Page 37
is
Checking the supply pressure and burner pressure
11. Use the pressure gauge to read the burner pressure at test nipple g. Refer
to Ta bl e 3 .5 .
n Remark
If the burner pressure is not correct and the water heater is fitted with a blank
plate, you will not be able to adjust the pressure. In this case, consult your
installer or supplier.
If the water heater is fitted with a burner pressure regulator, then the
pressure can be adjusted by following steps 12 through 16.
12. DR-RS 25, 40, 65 or 85:
Adjust the burner pressure by turning burner pressure control adjusting
screw c, depending on the correction required:
13. DR-RS 105
Adjust the burner pressure by turning burner pressure control adjusting
screw c (Pg) using the supplied Allen key, depending on the correction
required:
Adjusting screw Ps regulates the starting pressure. This need never AND
may never be adjusted!
14. Check the burner pressure against the value given in the table.
15. If the pressure setting is incorrect, then:
-For DR-RS 25, 40, 65 or 85 repeat steps 12 and 14 until the correct
pressure is achieved.
-For DR-RS 105 repeat steps 13 and 14 until the correct pressure is
achieved.
16. Shut down the water heater by putting the On/Off -switch to position 0.
17. Shut off the gas supply.
18. Disconnect the two pressure gauges and re-tighten the sealing screws in the
test nipples.
Instruction manual DR-RS37
Page 38
3
Installation
is
38Instruction manual DR-RS
Page 39
3.12 Conversion to a
different gas
category
Conversion to a different gas category
3.12.1Introduction
If the water heater must operate on a family of gas (LP gas or natural gas) or
other gas category than that for which the water heater has been set up at the
factory, the water heater will have to be adapted using a special conversion kit.
Warning
The conversion may only by carried out by an authorised installer.
Warning
After conversion, check the supply pressure and the burner pressure.
3.12.2Conversion
1. Disconnect the water heater from the mains. See paragraph 7.3.2 Isolate
the water heater from the power supply.
2. Shut off the gas supply.
3. Referring to Ta b le 3 . 5, compare the present gas category with the target gas
category and ascertain whether the diameter of the pilot flame orifice is
different. If this is the case, then the pilot flame orifice must be replaced. See
paragraph ’3.11.3 Replace orifice’.
4. Referring to Ta b le 3 . 5, compare the present gas category with the target gas
category and ascertain whether the diameter of the main orifice is different.
If this is the case, then the main orifices must be replaced. See paragraph
3.12.3 Replacing orifices.
5. Referring to Ta b le 3 . 5, compare the present gas category with the target gas
category and ascertain whether there is a different use of a flat plate or
burner pressure regulator. If this is the case, then these must be exchanged.
See paragraph 3.12.4 Replacing burner pressure regulator or flat plate
(DR-RS 25-40-65-85).
6. Referring to Ta b le 3 . 5, compare the present gas category with the target gas
category and make the appropriate adjustments. See paragraph
3.11 Checking the supply pressure and burner pressure.
n Remark
The present gas category is stated on the rating plate.
Instruction manual DR-RS39
Page 40
3.12.3Replacing orifices
Legend:
a strain relief
b lead for spark electrode
c lead for flame probe
d burner control
e gas control connector(s)
f gas control
g gas coupling
h burner tray
g
d
e
a
g
f
f
e
e
h
b
c
IMD-0254
Figure 3.12 Disassembled gas control
1. Detach the protective cap van the control column:
2. Remove the strain relief a and detach the leads of the spark electrode (b =
3. Unscrew the connector(s) e of the gas control f.
4. Detach the gas coupling g before the gas control.
5. Remove the ten screws holding the burner tray h in place.
6. Withdraw the burner tray from the water heater.
n Remark
Loosen the 4 screws and remove the protective cap by lifting it upwards. The
electrical section will now be visible.
red) and the flame probe (c = black) from the burner control d.
When exchanging the pilot flame orifice and/of orifices:
Lay the burner tray on its side and approach it from the underside.
40Instruction manual DR-RS
Page 41
Legend:
spark electrode
a
b flame probe
c pilot flame orifice socket
d pilot flame orifice
e main orifice
Conversion to a different gas category
d
e
Figure 3.13 Gas control
e
b
d
c
a
IMD-0255
7. If Ta bl e 3 . 5 Ga s d a ta indicates that the pilot flame orifice must be replaced:
a. Detach the spark electrode a from the retaining clip. This will give
clearance to disassemble the pilot flame orifice.
b. Turn the flame probe b to loosen it from the bracket and give more room.
c. Detach the pilot flame orifice socket c.
d. Replace the pilot flame orifice d with the pilot flame orifice of the correct
diameter from the conversion kit.
e. Fit the bracket, the flame probe and the spark electrode.
8. If Table 3.5 Gas data indicates that the main orifices of the burners must be
replaced:
a. Remove the main orifices e.
b. Fit the main orifices from the conversion kit. You can check the required
orifice diameter based on Tab le 3 . 5 Ga s da t a . The orifice diameter is
shown on the orifice by means of stamped figures.
9. If required, you must now also replace the burner pressure regulator or flat
plate. See paragraph 3.12.4 Replacing burner pressure regulator or flat
plate (DR-RS 25-40-65-85).
10. Return the burner tray to its place, tightening all the screws.
11. Re-fit the gas coupling before the gas control and screw the gas control
connector(s) back in place.
12. Connect the leads of the spark electrode and the flame probe to the burner
control and fit them in the strain relief.
13. Connect the gas.
Instruction manual DR-RS41
Page 42
14. Refit the protective cover.
n Remark
Refer to A Electrical diagram DR-RS for the connection of electrical
components.
3.12.4Replacing burner pressure regulator or flat plate
(DR-RS 25-40-65-85)
Referring to Tab l e 3. 5 G as d at a , ascertain whether the gas control needs to be
fitted with a burner pressure regulator or blank plate.
If necessary replace them:
1. Complete steps 7 through 9 of paragraph 3.12.3 Replacing orifices.
2. Detach the burner pressure regulator a or flat plate d. See Figure 3.11 Gas
control valve.
3. Fit the burner pressure regulator of flat plate from the conversion kit.
4. Complete steps 10 through 14 of paragraph 3.12.3 Replacing orifices.
5. Add a sticker to the Data Label.
n Remark
When you have completed replacing the necessary components, you must
adjust the supply pressure and burner pressure to match the target gas
category. See paragraph 3.11 Checking the supply pressure and burner
pressure.
42Instruction manual DR-RS
Page 43
gis
4Filling and draining
4.1IntroductionTopics covered in this chapter:
•Filling the water heater.
•Draining the water heater.
Instruction manual DR-RS43
Page 44
4
Legend
a pressure-reducing valve
(mandatory if the mains water
pressure exceeds 8 bar)
b expansion vessel (mandatory)
c T&P valve (mandatory)
ca) safety valve
d stop valve (recommended)
e non-return valve (mandatory)
ea) non-return valve
f circulation pump (optional)
g drain valve
h gas valve (mandatory)
i stop valve (mandatory)
j temperature gauge
(recommended)
k top to bottom recirculation
pump (optional)
l top box
m hot water draw-off points
n condensation drainage
o expension valve (mandatory)
p water tank
q float valve
r 3-way venting valve (optional)
s overflow pipe
a cold water supply
b hot water outlet
c circulation pipe
d gas supply
e flue gas discharge
Filling and draining
gis
The components referred to in these paragraphs are illustrated in Figure 4.1.
UNVENTED
m
e
l
d
f
e
d
h
d
c
VENTED
j
c
d
k
e
d
g
o
n
e
l
c
i
d
k
e
d
b
eia
j
b
a
IMD-0066
s
r
b
i
m
p
a
i
dfed
i
IMD-0065
Figure 4.1 Installation diagrams
c
g
d
h
4.2Filling the water
heater
4.2.1Filling unvented installations
To fill the water heater, proceed as follows.
1. Open the stop valve i in the hot water pipe and, if present, the stop valves
d for the circulation pump.
2. Shut drain valve g.
44Instruction manual DR-RS
Page 45
gis
Draining the water heater
3. Open the nearest hot water draw-off point m.
4. Open the supply valve i on the cold water side a so that cold water flows
into the water heater.
5. Completely fill the water heater (when cold water flows at normal pressure
from the nearest hot water draw-off point, the water heater is full).
6. Vent the entire installation of air, for example by opening all hot water drawoff points.
7. The water heater is now under water supply pressure. There should be no
water coming out of the expansion valve o nor the T&P valve c. If this does
happen, the cause might be:
-The water supply pressure is greater than the specified 3.5bar.
Rectify this by fitting a pressure-reducing valve a.
-The expansion valve in the protected cold supply setup is defective or
incorrectly fitted.
4.2.2Filling vented installations
To fill the water heater, proceed as follows.
1. Open the stop valve i in the hot water pipe and, if present, the stop valves
d for the circulation pump.
2. Shut drain valve g.
3. Open the nearest hot water draw-off point m.
4. Open the supply valve i on the cold water side a so that cold water flows
into the water heater.
5. Completely fill the water heater (when cold water flows at normal pressure
from the nearest hot water draw-off point, the water heater is full).
6. Vent the entire installation of air, for example by opening all hot water drawoff points.
7. The water heater is now under water supply pressure. There should be no
water coming out of the T&P valve c. If this does happen, the T&P valve
might be defective or incorrectly fitted.
4.3Draining the water
heater
4.3.1Draining unvented installations
4.3.2Draining vented installations
Some service activities require the water heater to be drained. The procedure
is as follows:
1. Shut the water heater down by putting the On/Off switch to position 0.
2. Disconnect the water heater by putting switching the mains isolator off.
3. Shut off the gas supply h.
4. Close the stop valve i in the hot water pipe.
5. Close the supply valve in the cold water supply a.
6. Open the drain valve g.
7. Vent the water heater (or installation) so that it drains completely.
Some service activities require the water heater to be drained. The procedure
is as follows:
1. Shut the water heater down by putting the On/Off switch to position 0.
2. Switch the mains isolation off.
3. Shut off the gas supply h.
Instruction manual DR-RS45
Page 46
4
Filling and draining
gis
4. Close the stop valve i in the hot water pipe.
5. Close the stop valve between the water tank and the cold water inlet.
6. Open the drain valve g.
46Instruction manual DR-RS
Page 47
gis
5Controls
5.1IntroductionTopics covered in this chapter:
•5.2 Control panel;
•5.3 Explanation of the symbols;
•5.4 ON/OFF switch;
•5.5 Control thermostat;
•5.6 Burner control reset button;
5.2Control panelFigure 5.1 shows the control panel The panel consists of:
•an ON/OFF switch;
•a reset button;
•a control thermostat with rotary knob;.
IMD-0363
Figure 5.1 The control panel
Instruction manual DR-RS47
Page 48
5
Controls
gis
5.3Explanation of the
symbols
5.4ON/OFF switchThe ON/OFF switch is used to put the water heater in the ON mode or OFF
Table 5.1 shows the meanings of the symbols on the control panel.
Table 5. 1 Icons and their meaning
SymbolNameExplanation
ON/OFF switch’ON mode’ / ’OFF mode’
Reset button with error
indicator
Temperature controlTo set water temperature (T
mode. The water heater remains live, even when in the OFF mode. This
ensures the frost protection remains activated.
Reset burner control
set
)
n Remark
To electrically disconnect the water heater, you must use the isolator
between the water heater and the mains power supply.
5.5Control thermostatUse the rotary knob on the control thermostat to set the desired water
temperature to between 40°C and 70°C. The rotary knob is continuous, over a
scale of 1 to 4. Table 5.2 shows the temperatures corresponding to each
position.
Table 5. 2 Temperature setting
5.6Burner control reset
button
PositionTemperature
1
2≈ 50°C
3≈ 60°C
4≈ 70°C
An error can cause the burner control to lock out. When this happens, the red
lamp in the reset button will light up. After eliminating the cause of the error, you
can reset the water heater using the reset button.
≈ 40°C
n Remark
Before resetting, always eliminate the cause of the error.
To identify the various errors, refer to chapter 6 Status of the water heater.
Chapter 8 Troubleshooting describes how to troubleshoot errors and problems.
48Instruction manual DR-RS
Page 49
gis
6Status of the water
heater
6.1IntroductionTopics covered in this chapter:
•6.2 Operating modes;
•6.3 Error conditions;
6.2Operating modesWhen running, the water heater has three basic operating modes, namely:
•DISCONNECTED
In this mode the water heater is off and all components are electrically dead.
The isolator (switch between the water heater and the power supply) is
turned off. On the control panel, the ON/OFF switch is at position 0.
•OFF
In this mode, the frost protection is activated. The isolator is set to position
I. On the control panel, the ON/OFF switch is at position 0.
•ON
In this mode the water heater continuously fulfils the demand for heat. On
the control panel:
-the ON/OFF switch is at position I;
-The water temperature can be set by turning the rotary knob on the
control thermostat, see paragraph 5.5 Control thermostat.
6.3Error conditionsIf the water heater has an error the heater will not operate. The frost protection
will also be out of operation.
If the water heater should go into an "error" state, you will be unable to
continuosly draw hot water. These error conditions are divided into three
groups:
•Lock out error in the burner control
When this happens, the red error lamp in the reset button will light up on the
control panel. The burner control is locked out.
After removing the cause, the reset button must be pressed to re-start the
water heater.
•The water heater cycles continuously
When this happens, the water heater continues to attempt to start-up, but an
error is causing the heating cycle to fail.
See paragraph 7.4 The water heater’s heating cycle.
After removing the cause, the water heater will start-up again by itself.
•Blocking errors
You can recognise this condition by the fact that the water heater makes no
attempt to start operation, despite the water temperature being lower than
the control thermostat setting (see 5.5 Control thermostat). These errors
disappear automatically once the cause of the error has been removed, after
which the water heater resumes by itself.
The cause of the error cannot be seen on the control panel. For a detailed
overview of error conditions, please refer to chapter 8 Troubleshooting.
Instruction manual DR-RS49
Page 50
6
Status of the water heater
gis
If, as end-user, you find the water heater in an error condition, you may attempt
to re-start the water heater by pressing the reset button once. However, should
the error return or become persistent, you should contact your service and
maintenance engineer.
50Instruction manual DR-RS
Page 51
gis
7Starting up and
shutting down
7.1IntroductionTopics covered in this chapter:
•Starting up;
•Shutting down;
•The water heater’s heating cycle.
7.2Starting upStart-up the water heater as follows:
1. Fill the water heater. See chapter 4 Filling and draining.
2. Open the manual gas valve (see Figure 4.1 Installation diagrams).
3. Switch on the power to the water heater using the isolator between the water
heater and the power supply.
4. Set the water heater in ’ON mode’ by switching the ON/OFF switch on the
control panel to position I.
5. Set the desired water temperature using the control thermostat. See
paragraph 5.5 Control thermostat
If there is a heat demand, the water heater will run through a heating cycle. See
paragraph 7.4 The water heater’s heating cycle.
7.3Shutting downYou can:
•Shut the water heater down for a brief period (’OFF mode’).
•Isolate the water heater from the power supply.
•Shut the water heater down for a longer period.
7.3.1Shut the water heater down for a brief period (’OFF mode’)
To shut the water heater down for a brief period, you must activate the frost
protection. Refer also to paragraph 2.3 The water heater’s heating cycle.
You can use the frost protection to prevent water freezing in the water heater.
Activate the frost protection by switching the ON/OFF switch on the control
panel to position 0.
7.3.2Isolate the water heater from the power supply
The water heater should only be isolated from mains power in the correct way.
The correct procedure is as follows:
1. Shut the water heater down by switching the ON/OFF switch to position 0.
2. Isolate the water heater by switching the isolator between the water heater
and the mains power supply to position 0.
7.3.3Shut the water heater down for a longer period
Drain the water heater, if you are shutting it down for a longer period of time.
Proceed as described in paragraph 4.3 Draining the water heater.
Instruction manual DR-RS51
Page 52
7
Starting up and shutting down
gis
7.4The water heater’s
heating cycle
The water heater’s heating cycle is activated as soon as the measured water
temperature (T
depends on the currently selected water heater operating mode. For example,
if the water heater is in the ’OFF mode’ (frost protection), then this value is 20°C.
If the water heater is in the ’ON mode’, then this threshold value is selectable,
for example, position 3 (60°C).
The heating cycle runs in turn through the following states:
1. Heat demand;
2. Zero state control by pressure switch;
3. Start fan;
4. Pressure difference in air supply;
5. Ignition of pilot flame;
6. Ignition of burner tray;
7. Running.
The complete cycle is explained in the example set out below.
) falls below the threshold value (T
water
). This threshold value
set
n Remark
The water heater runs through an identical cycle when frost protection is
activated.
1. The control thermostat sensor measures the water temperature. The water
temperature falls below the set temperature, e.g. 60°C, causing the control
thermostat to close. The burner control now detects a heat demand and
starts the heating cycle.
2. Once the heat demand is registered, the burner control runs a zero state
control on the pressure switch and the fan begins drawing air.
3. Once the air supply is guaranteed to be sufficient, the pilot flame is ignited.
4. Following ignition, once the pilot flame is verified by ionisation detection, the
burner tray is ignited: the water heater is now running. This means that
actual heating has started.
5. When the water is up to temperature, the heat demand cuts out. The gas
control closes and the pilot flame and the burner tray are extinguished.
With any subsequent heat demand, the heating cycle will resume from step 1.
52Instruction manual DR-RS
Page 53
gis
8Troubleshooting
8.1IntroductionThis chapter covers the following errors:
•Gas smell.
•Water leakage.
•Explosive ignition.
•Poor flame profile.
•No hot water
•Insufficient hot water.
If the water heater has gone into an error condition, then the heat demand will
be (temporarily) ignored and no hot water will be supplied. The frost protection
will also be out of operation. The error conditions are divided into three groups:
•Lock out error in the burner control
When this happens, the red error lamp in the reset button will light up on the
control panel. The burner control is locked out.
After removing the cause, the reset button must be pressed to re-start the
water heater.
•The water heater cycles continuously
When this happens, the water heater continues to attempt to start-up, but an
error is causing the heating cycle to fail.
See paragraph 7.4 The water heater’s heating cycle.
After removing the cause, the water heater will start-up again by itself.
•Blocking errors
You can recognise this condition by the fact that the water heater makes no
attempt to start operation, despite the water temperature being lower than
you have set with the control thermostat (see 5.5 Control thermostat). These
errors disappear automatically once the cause of the error has been
removed, after which the water heater resumes by itself.
n Remark
Footnotes referred to from within any table are shown at the bottom of the
last page of that table.
Instruction manual DR-RS53
Page 54
is
Immediately contact your installer or local gas company.
n Remark
Warning
Immediately close the main gas valve.
Warning
Maintenance may only be performed by a qualified service and maintenance engineer.
8.2Troubleshooting table for general errors
Table 8. 1 General errors (Sheet 1 of 2)
Gas smellGas leak
SymptomCauseSolutionRemark
Warning
Do not operate any switches.
Warning
No naked flames.
Warning
Ventilate the boiler room.
Tighten the threaded connection. If the leak persists, consult your installer.
Water leakageLeakage from one of
Trace the leak.
Leakage from another
(threaded).
nearby water water
the water connections
heater or pipe
segment.
Consult the supplier and/or manufacturer.
Leakage from the
water heater’s hot
the heater has reached the set temperature.
water tank.
CondensationBefore drawing off (too much) hot tap water, wait until the water in
Instruction manual DR-RS54
Page 55
is
If the error has not been rectified and no other cause can be found,
isolate the water heater from the power supply, shut off the gas
If ignition is not improved, consult your installer.
valve and alert your installer.
heater enough time to heat up the water.
thermostat is cutting in/out. If so, check that the circulation-
and/or top to bottom recirculation pump are working properly.
1. Reduce the rate of hot water consumption. Allow the water
Contaminated orifice.Clean the orifice. See 9.4.3 Cleaning the orifices
Improve the air supply.
Contaminated air
supply
8.3Troubleshooting table ’insufficient hot water’
If the water heater fails to supply any hot water, there are several possible causes.
Refer to Table 8.2 Insufficient hot water
Table 8. 2 Insufficient hot water
Set the correct supply pressure and/or burner pressure, see
3.11 Checking the supply pressure and burner pressure.
Incorrect supply
pressure and/or burner
pressure.
Contaminated burnerClean the burner. See 9.4.2 Cleaning the burners
Warning
Maintenance may only be performed by a qualified service and maintenance engineer.
SymptomCauseSolutionRemark
Explosive ignition
Table 8. 1 General errors (Sheet 2 of 2)
Poor flame profile
SymptomCauseSolutionRemark
Set the control thermostat to a higher setting. See paragraph
5.5 Control thermostat.
) is too low
set
setting (T
Insufficient hot waterThe water temperature
Hot water supply used
up.
2. If this error occurs regularly, check whether the high-limit
Instruction manual DR-RS55
Page 56
is
See appendix A Electrical diagram DR-RS. If you cannot resolve
the error, contact your installer.
If the error has been corrected, the water heater will automatically
If the error cannot be resolved or is persistent, contact your
resume running when there is a heat demand.
If the error cannot be resolved or is persistent, contact your
installer.
installer.
thermostats.
compliance with the directions. See paragraph 3.9 Air supply
1. Check that the chimney installation has been constructed in
Too much resistance in
the flue gas discharge
(the air pressure
Repeated starting of
the heating cycle
(cycling of water
and flue gas discharge.
switch opens during
heating).
heater)
Instruction manual DR-RS56
•Trace the blockage.
•Remove the blockage.
•Check the wiring of the air pressure switch.
•Check that the air pressure switch is working properly.
1. Check that the isolator is ON.
2. Check the voltage across the isolator.
3. Check the voltage on the electrical connector block.
4. Check the voltage on the burner control.
5. Check the fuse in the burner control.
The measured voltage must be 230 VAC +15% -10%.
1. Blockage in the flue gas discharge or air supply:
No voltage from power
If the water heater fails to supply any hot water, there are several possible causes.
Refer to table Table 8.3 No hot water.
Warning
Maintenance may only be performed by a qualified service and maintenance engineer.
8.4Troubleshooting table ’no hot water’
Table 8. 3 No hot water (Sheet 1 of 2)
supply.
SymptomCauseSolutionRemark
No attempt to start
the heating cycle
The air pressure
No attempt to start
switch does not close.
the heating cycle
(blocking error)
2. Defective air pressure switch
1. Check that the control thermostat is switched (closed).
Break in the
thermostat circuits.
2. Check the leads and sensors of the control and high-limit
Page 57
is
See paragraph 7.4 The water heater’s heating cycle
If the error cannot be resolved or is persistent, contact your
If the error cannot be resolved or is persistent, contact your
installer.
If the error cannot be resolved or is persistent, contact your
installer.
installer.
1. Check whether the control thermostat is working.
2. Check whether the high-limit thermostat is working.
1. Check whether the thermostat is defective.
2. Check whether the thermostat sensor is defective.
3. Check the wiring of the thermostat.
No gas:
1. Check that the gas valve is open.
2. Check that gas control opens (clicking of the gas control).
3. Check the gas control wiring.
No ignition:
1. Check whether the spark igniter sparks in the pilot flame cap.
2. Check the wiring of the hot surface igniter.
3. Check that the spark igniter is correctly fitted in the bracket.
No flame detection:
1. Check that the flame probe is not defective.
2. Check that the wiring to the flame probe is correctly connected.
There are 3 possible causes for this error: (a), (b) or (c). To determine the cause, you need
to make the error recur while checking which phase of the heating cycle this happens in.
1. Reset the water heater by pressing the reset button 1x;
2. Cause (a) occurs between steps 4 and 5 of the heating cycle;
3. Cause (b) occurs in step 5 or 6;
4. Cause (c) occurs in step 7.
(a) Constant
interruption in the
safety circuit
(b) Failed attempt to
start
Warning
Maintenance may only be performed by a qualified service and maintenance engineer.
Reset button
illuminated (lock out
Table 8. 3 No hot water (Sheet 2 of 2)
error in burner
control)
3. Check that the circulation pump (if present) is working.
(c) Interruption in the
safety circuit during
heating (the safety
thermostat has cut out)
Instruction manual DR-RS57
Page 58
is
Warning
Maintenance may only be performed by a qualified service and maintenance engineer.
Instruction manual DR-RS58
Page 59
s
9Maintenance
9.1Introduction
cNote
Maintenance may only by carried out by an approved service and
maintenance engineer.
At each service, the water heater undergoes maintenance both on the water
side and on the gas side. The maintenance should be carried out in the following
order.
1. Preparing for maintenance;
2. Water-side maintenance;
3. Gas-side maintenance;
4. Finalising maintenance.
9.2Preparing for
maintenance
n Remark
Before ordering spare parts, take a moment to write down the water heater
type and model and the full serial number of the water heater. Only by
ordering with this information can you be sure to receive the correct spare
parts. These details can be found on the rating plate.
To test whether all components are still working properly, you should complete
the following steps:
1. Put the ON/OFF switch on the control panel to position 0.
2. Set the control thermostat (note the original setting) to the highest position
and put the ON/OFF switch back to position I.
3. If there is no heat demand, draw some hot water off to initiate a heat
demand.
4. Check whether the heating cycle runs correctly. See paragraph 7.4 The
water heater’s heating cycle.
5. Set the control thermostat back to the original setting and put the ON/OFF
switch back to position I.
6. Check the supply and burner pressures and adjust these, where necessary.
See paragraph 3.11 Checking the supply pressure and burner pressure.
7. Check that all components of the flue gas system are properly attached.
8. Test the operation of the expansion valve of the cold supply setup. The water
should spurt out.
9. Test the overflow operation of the T&P valve. The water should spurt out.
10. Check the drain pipes from the discahrge points of any valve and remove
any lime buildup that may be present.
11. Drain the water heater. See paragraph 4.3 Draining the water heater.
Instruction manual DR-RS59
Page 60
9
9.3Water-side maintenance
9.3.1Introduction
9.3.2Checking the anodes
Maintenance
s
The following steps should be carried out on the water side:
1. Checking the anodes.
2. Descaling and cleaning the heater.
Timely replacement of the anodes extends the service life of the water heater.
The water heater’s anodes must be replaced as soon as they are 60% or more
used up (take this into consideration when determining the maintenance
frequency).
1. Remove the chimney attachments from the top box.
2. Detach the lid of the top box.
3. Detach the fan leads and remover the lead from the strain relief.
4. Undo the screws of the top box.
5. Remove the top box from the water heater.
6. Undo the screws of the cover on the top of the water heater.
7. Remove the cover from the water heater.
8. Remove the sealing ring from the hot water tank.
9. Loosen the anodes using suitable tools (27 mm A/F).
10. Check the anodes and if necessary, replace them.
11. Now also check the flue baffles. Replace them, if necessary. See paragraph
9.4.4 Checking the flue baffles.
12. Fit a new sealing ring around the edge of the hot water tank and replace the
cover.
13. Replace the top box.
14. Feed the fan lead through the strain relief and connect the lead to the fan.
See appendix A Electrical diagram DR-RS.
15. Fit the lid back on the top box.
9.3.3Descaling and cleaning the heater
Scale and lime buildup prevent effective conduction of the heat to the water.
Periodic cleaning and descaling prevents buildup of these deposits. This
increases the service life of the appliance, and also improves the heating
process.
Take the rate of scale formation into account when deciding on maintenance
frequency. Scale formation depends on the local water composition, the water
consumption and the water temperature setting. A water temperature setting of
maximum 60
To guarantee a good, watertight seal around the cleaning opening, the gasket ,
O-ring g, spring washers, bolts and if necessary, the lid c should be replaced
with new parts before reassembly. See Figure 9.1. A special set is obtainable
from Hamworthy for this purpose.
60Instruction manual DR-RS
O
c is recommended for prevention of excessive scale buildup.
Page 61
s
Gas-side maintenance
To simplify descaling and cleaning of the tank, the appliance is equipped with
two cleaning openings.
1
Figure 9.1 Cleaning opening
1. Remove the cover plate a on the outer jacket. See Figure 9.1.
2. Carefully remove the insulation b and set it to one side. This will be needed
3. Undo the bolts.
4. Remove the lid, the gasket and the O-ring.
5. Inspect the tank and remove the loose scale deposits and contamination.
6. If the scale cannot be removed by hand, then the appliance will need to be
7. Close the cleaning opening. To avoid damage to the tank, the bolts that
1
5
3
2
again later.
descaled using a suitable cleaner.
fasten the lid should be tightened with a torque no greater than 50 Nm. Use
suitable tools for this. To properly seal the cleaning opening, we recommend
tightening the bolts in the sequence shown in Figure 9.2.
5
6
3
4
7
4
6
2
Figure 9.2 Bolt tightening
sequence
9.4Gas-side maintenance
Take care
The burners may be
hot.
9.4.1Introduction
The following steps should be carried out on the gas side:
1. Cleaning the burners.
2. Cleaning the orifices.
3. Checking the flue baffles.
9.4.2Cleaning the burners
1. Detach the burners.
2. Carefully remove any contamination present on the burners.
3. Re-attach the burners.
Instruction manual DR-RS61
Page 62
9
9.4.3Cleaning the orifices
9.4.4Checking the flue baffles
Take care
The flue baffles may
be hot.
Maintenance
s
1. Remove the orifices.
2. Remove any contamination present in the orifices.
3. Re-attach the orifices.
1. Complete steps 1 through 8 of paragraph 9.3.2 Checking the anodes.
2. Remove the flue baffles from the water heater.
3. Check the flue baffles for rust and remove any which is present.
4. Check the flue baffles for wear and replace any worn flue baffles.
5. Complete steps 12 through 15 of paragraph 9.3.2 Checking the anodes.
9.5Finalising maintenance
To finalise the maintenance carry out the following steps:
1. Fill the water heater. See paragraph 4.2 Filling the water heater.
2. Re-start the water heater. See 7.2 Starting up.
62Instruction manual DR-RS
Page 63
is
AElectrical diagram
DR-RS
Instruction manual DR-RS63
Page 64
Legend
A Jacket
Brown
B Isolating transformer
Blue
Yellow / Green
C APDS (Air pressure differential switch)
Black
D Filter
E Reset button
White
Red
F Frost thermostat
G Control thermostat
H ON/ OFF switch
K Safety thermostat
L High-limit thermostat
M Burner control
N Connector clip strip
P Earthing strip
R Relay (Max. 250V, 10A)
OPTIONAL COMPONENTS:
S Clock
T Potentiostat
White / Orange
White / Purple
Black / Green
Black / Red
Black / White
Figure A.1 Electrical diagram DR-RS
Instruction manual DR-RS0307248 _R1.364