Door-Gard COMMAND AND CONTROL SERIES Programming Manual

FEATURES AND PROGRAMMING GUIDE
COMMANDANDCONTROLSERIES
DOOR-GARD COMMAND AND CONTROL SERIESDOOR-GARD COMMAND AND CONTROL SERIESkeypads offer field proven reliability and cost effective solutions anywhere limited control or access is desired. Designed for individual control of up to four devices, Door-Gard Command and Control Series keypads are the perfect choice for controlling electric locking devices, security systems, automatic operators or machinery. Door-Gards accept power from a 12 or 24V AC/DC Supply.
FEATURES:
• 4 INDEPENDENT OUTPUTS
• ALL OUTPUTS ASSIGNABLE BY CODE
• ON BOARD 8 AMP FORM C RELAY
• 120 USERS
• REMOTE TRIGGERING INPUT
• KEYPAD PROGRAMMABLE
MEMORY
Non-volatile EEPROM memory means your codes and instructions will be there whether you remove power for 5 minutes or 5 years.
PROGRAMMING
All programming is accomplished entirely from the front of the keypad. LED or Sounder guidance makes program­ming easy, and changing codes a matter of seconds for an authorized user.
CODES
The Door-Gard Command and Control keypads allow up to 120 individual user codes to be valid. Codes may be from 1-6 digits in length and digits may be repeated. The Master Code is always assigned to user location one (1)Master Code is always assigned to user location one (1).
MAIN RELAY
This is an 8 Amp (10 Amp surge) Form-C relay which can be toggled or timed from 1 to 90 seconds-by code.
AUXILIARY OUTPUTS
Auxiliary outputs can be individually timed from 1 to 90 seconds or act as a toggle switch, and may be triggered individually or in combination-by code. The Ruggedized(r), Sealed Environmental(se), Multipad and Xtreme style pro­vide these outputs in the form of 1 Amp Form-C relays, all other styles have negative voltage outputs with a 50mA sink.
REMOTE TRIGGERING INPUT (REX)
This normally open loop that by default operates the Main Relay upon activation and can be programmed to trigger any combination of outputs. Upon a momentary closure, the selected outputs will energize for their programmed time. The main relay (if selected) will energize for the same time period as the Master Code. This feature is especially useful when controlling an electric locking device.
KEYPRESS FEEDBACK / AUDIBLE KEYPRESS
The Command and Control Series Door-Gards will acknowl­edge a keypress by momentarily illuminating the yellow LED like on the indoor(i), or momentarily sounding the sounder like in the sealed environmental(se) style. This can be turned off through programming.
KEYPAD ACTIVE OUTPUT
The Command and Control Series Door-Gards can be programmed to energize a voltage output whenever a key is touched. This can be used to turn on accessories such as lights, CCTV camera, or notify a guard. This output is not available if the IEI 250 Printer Interface is used.
AUTO-ENTRY
This feature is used when the need for the code not to be followed by the * key is desired. The user only needs to enter their code number and the relay will activate for the programmed relay time. To use this feature, the user codes must be the same length as the master code.
AUDIT TRAIL * An accurate real-time audit trail can be provided by any Command and Control Series Door-Gard with the addition of an optional model 250 Printer Interface. The 250 can monitor up to 8 keypads simultaneously. The 250 comes with power supply and printer cable and connects easily to any parallel line printer (not included).
* This option is not available with some styles of keypads. Call IEI for a list of product, or visit us on the web!
605-0212 Rev 1.04
1 2
TESTING THE KEYPAD
1. 1. Connect the positive (+) lead of your power supply to the terminal strip (TS1) +V input.
2.2.Connect the negative (-) lead of your power supply to the terminal strip (TS1) -V input.
3. 3. Turn on your power supply.
4.4.Press 7890#123456*. If all 12 keypresses have
been verified, the keypad will enter self test mode. Either the LED’s will flash or the sounder will beep 3 times,.then light or sound continuously for 3 sec onds (except on the mullion). If these responses do not happen, try the test mode again and then call tech support. Note:Note:self test mode can be used when troubleshooting a keypad in the field. If you do not get the continuous light or sound then the mem ory has been corrupt and should be re-programmed with the 46 command (see option #19).
5. 5. Enterthe master code of 1234*. The relay will ener gize. Refer to programming section to program your keypad.
NOTE:NOTE:
The keypad may be programmed in your shop or at the installation site. Programmed information is stored in non­volatile memory so it will not be lost if power is removed.
COMMAND AND CONTROL DEFAULTS
The Door-Gard Command and Control Series keypads are designed for easy installation in a minimum amount of time. The following defaults have been factory programmed.
Master Code (user 1) 12341234 Main Relay will energize for 5 seconds5 seconds Auxiliary Outputs will energize for 5 seconds5 seconds Panic will energize Output 4Output 4 Keypad Active Output OffOff Remote Triggering Input will energize Main RelayMain Relay Keypress Feedback OnOn
Led on when powered up REDRED Led on when relay is activated GREENGREEN
If defaults must be changed or additional functions are desired, please refer to the PROGRAMMING
OPTIONSchart after you are familiar with the PROGRAMMINGsection.
PROGRAMMING
1. Enter programming mode Yellow LED
Press 99 # (master code)
2. To change master code
Press 1 # (new master code) *Flashes fast Repeat (new master code)
If main relay time must be changed, substitute option 2 from PROGRAMMING OPTIONSCHARTfor step above.
3. To add/change second code
Press 2 # (new user code) *Flashes fast Repeat (new user code)
4. To add/change third code
Press 3 # (new user code) *Flashes fast Repeat (new user code)
5. Up to 120 codes may be added in this fashion
6. Exit programming mode
Press
NOTES:
•User location represents one location in memory where an individual code is stored. A user code is stored in it’s own user location. There are 120 user locations available.
•1Some Door•Gard products contain a sounder in place of the yellow LED. In these products the flashing is replaced by a beeping.
• 2The master code is always in user location 1The master code is always in user location 1.
•The master code allows access to the
programming mode & activates the main relay.
•All codes must be followed by the **key
•Codes may be from 1-6 digits in length, and digits may be repeated.
If the master code is forgotten or does not seem toIf the master code is forgotten or does not seem to
be workingbe working, momentarily push SW1 on the circuit board, (see wiring diagram for location) to enter pro-
gramming mode and follow step two from above to program a new master code.
•If the yellow LED lights (or sounder sounds) solid while
in programming mode an error has occurred. Press to clear (yellow LED should flash or sounder sound) and start over from step 2 or 3 above.
**
**
2
*
*
*
Flashes slowly
Flashes slowly
Flashes slowly
Flashes slowly
Out
.
1
*
3
PROGRAMMING OPTIONS CHART
If the pre-programmed default values must be changed or additional functions are desired, the following options may be programmed.
1. Enter programming mode Press 99 # (master code)
2.Change master code/set main relay time
Example: Master code of 4321/relay time of 10 seconds Press 10 # 1 # 4321 * 4321 *
1 (SEEBELOW)
Press (Relay Time) # 1 # (new code) *(repeat code)
3. Add/change user code Press (user location) # (new code) *(repeat code)
4.Add/change user code with a different output Press (Relay Time) # (user location) # (new code)
time on main relay
1 (SEEBELOW)
(repeat code)
*
5. Delete user codes Press (user location) #
6. Set output 2 time
7. Set output 3 time
8. Set output 4 time
1 (SEEBELOW)
1 (SEEBELOW)
1 (SEEBELOW)
Press 12 # (Relay Time) # 0 # Press 13 # (Relay Time) # 0 # Press 14 # (Relay Time) # 0 #
9. Set outputs for Remote Triggering Input Press 17 # (outputs: .ie. 1, 2 or 2, 3 etc.) # 0 #
**
*
*
**
**
** **
**
Note: 0= no outputs
10. Set outputs for Panic
2 (SEEBELOW)
Press 18 # (outputs: i.e. 1, 2 or 2, 3 etc.) # 0 #
**
Note 0= no outputs
11.Turn keypress feedback/audible keypress on Press 30 # 0 # 1 #
12.Turn keypress feedback/audible keypress off Press 30 # 0 # 0 #
**
**
*
13. Turn yellow LED/sounder on with relay Press 30 # 1 # 1 #
14. Turn yellow LED/sounder off with relay Press 30 # 1 # 0 #
15.Turn auto entry on Press 30 # 2 # 1 #
16.Turn auto entry off Press 30 # 2 # 0 #
17. Turn keypad active output on
3 (SEEBELOW)
Press 43 # 0 # 99 #
18. Turn keypad active off Press 43 # 0 # 00 #
**
**
**
**
** **
19. Erase keypad memory/reset defaults Press 46 # 00000 # 00000 #
20. Energize selected output(s) with a user code
4
Press 59 # (outputs: i.e. 1, 2 or 2, 3 etc.) #
(user location) # (new code) * (repeat code) *
Example: User 2; code of 4321*; energize outputs 2 & 3 Press 59 # 23 # 02# 4321 * 4321 *
NOTES:
1 1
Relay time must always be represented by 2 digits. Example: 5 seconds = 05.
Latching /toggle is accomplished by entering a time of 00
22
If selected, panic will operate by pressing the * and # simultaneously.
Panic operates for 1 second and is defaulted to output 4.
33
Keypad active is a negative voltage output (sink) available
on terminal (or wire) marked WB (see wiring diagrams for location).
**
44
This feature is not available with the master code.
COMMAND& CONTROL STYLES:
212i-INDOOR STYLE
• Flushmount indoor design.
212w-WEATHER RESISTANT STYLE
• Flushmount outdoor design.
212r-RUGGEDIZED STYLE
• Weatherproof self-contained metal housing.
• Vandal resistant.
• Cast metal housing suitable for wall, post or gooseneck mounting.
• Available in White or Black.
• 4 On-Board relays.
212se-SEALED ENVIRONMENTAL STYLE
• Weatherproof self-contained metal housing.
• Vandal resistant.
• Small design suitable for residential, commercial
ACCESSORIES:
DATA LOGGING
• IEI-250 PRINTERINTERFACEprovides power, communication inputs and outputs for up to 8 Door•Gard Keypads. Interfaces with any parallel printer for user/door activity logging.
INSTALLATION
• IEI-280 WEATHERPROOFSURFACEBACKBOX.
• IEI-281 FLUSHMOUNTBACKBOX.
• IEI-290 12 VDC PLUG-INPOWERSUPPLY. 300MA.
• IEI-293 THREERELAYPLUG--INBOARDwith FORM C,1 amp relays. Converts transistor outputs to dry contacts (for use with Command and Control indoor, weather resistant and mullion styles).
and industrial applications.
• 4 On-Board relays.
212m-MULLION STYLE
• Weather resistant metal housing.
• Two-piece design with secured electronics.
• Narrow housing suitable for aluminum door frame mounting.
• Available in Bronze or Satin Aluminum
212mp MULTIPAD BACKLIT STYLE212mp MULTIPAD BACKLIT STYLE
• Weatherproof self contained housing.
• Illuminated keys.
• Contemporary design.
• 4 On-Board relays.
This list will change frequently. Be sure to check our web site!This list will change frequently. Be sure to check our web site!
TAMPER PROTECTION
• IEI-282 TAMPERSWITCHdetects faceplate removal.
• IEI-283 SECURITYMODULEresponds to tamper switch (included) and cuts all in/out power to the door lock. Wires can’t be crossed to unlock door. Must be reset from inside the protected area.
• IEI-289 TAMPERSCREWS- TRI-HEAD.
• IEI-267 1/4” DRIVER.
• IEI-270 ADAPTERSOCKET- TRI-HEAD.
• IEI-288 TAMPERSCREWS- ALLENWITHPIN.
• IEI-271 TAMPERWRENCH- ALLENWITHPIN.
OTHER DOOR-GARD PRODUCTS FROM IEI
CONTROL PANEL INTERFACE SERIES
210 – Programmable Keypad- Direct hardwire
keyswitch replacement.
240 – Battery Operated Keypad- Direct keyswitch
replacement (for indoor use).
262 – The Partitioner- Self-contained 2-zone control.
SELF-CONTAINED ACCESS CONTROL SYSTEMS
232i – Indoor keypad 232w – Weather-resistant 232se – Sealed environmental keypad 232r – Ruggedized keypad 232m – Mullion keypad 233 – Card Reader System 234 – Keypad/Card Reader System
If this product does not seem to operate properly, please call our Technical Department toll free at 1-800-343- 9502 (781-821-5566) Monday -Friday 8:00 am-7:00 pm EST. We understand your time is valuable, and we know that calling our Technical Support Department will ensure that you’ll make the most profit possible with your IEI product. Thank you for your purchase. We appreciate your business.
International Electronics,Inc.(IEI) warrants its products to be free from defects in material and workmanship, when they have been installed in accordance with the
manufacturer’s instructions, and have not been modified or tampered with. IEI does not assume any responsibility for damage or injury to person or property due to improper care, storage handling, abuse, misuse, normal wear and tear, or an act of God.
charges prepaid), after obtaining IEI’s Return Merchandise Authorization. IEI will not be liable to the purchaser or any one else for incidental or consequential damages aris­ing from any defect in, or malfunction of, its products.
er, including, without limitation to, the condition of its products, their merchantability, or fitness for any particular reason.
IEI’s sole responsibility is limited to the repair (at IEI’s option) the replacement of the defective product or part when sent to IEI’s facility (freight and insurance
This warranty shall expire two years after shipping date. Except as stated above, IEI makes no warranties, either express or implied, as to any matter whatsoev-
INTERNATIONAL
INTERNATIONAL ELECTRONICS, INC. 427TURNPIKE STREET, CANTON,MA02021 U.S.A. 800-343-9502, (781)-821-5566 (781)-821-4443 (FAX)
TM
ELECTRONICS, INC
FAX INFORMATION CENTER 781-821-0734 (FROM YOUR FAX MACHINE)
FEATURING
• Lock Release Relay • Propped Door Alarm Relay
• Lock Release Time • Timed Egress Input
• Alarm Zone Shunting Relay • Forced Door Alarm Relay
• Multiple User • Front Programmable
MADE IN U.S.A.
605-0212
REV. 1.04
www.ieib.com
Loading...