FEATURES AND PROGRAMMING GUIDE
SELF-CONTAINED ACCESS CONTROL SYSTEMS KEYPADS:
DOOR-GARD SELF-CONTAINED ACCESS CONTROL SYSTEMS offer field proven reliability and cost effective solutions for
residential, commercial and industrial installations. Elegant yet durable, Door• Gard systems blend with virtually any
decor. Designed for compatibility with virtually any electric locking device, Door• Gards accept power from a 12 or 24V
AC/ DC supply. No separate programmer is ever necessary.
FE ATURES :
•
LOCK RELEASE RELAY
•
LOCK RELEASE TIMER
•
FORCED DOOR ALARM RELAY
•
PROPPED DOOR ALARM RELAY
•
ALARM ZONE SHUNTING RELAY
•
TIMED EGRESS INPUT
•
120 USERS
•
FRONT PROGRAMMING
MEMORY
Non-volatile EEPROM memory means your codes and
instructions will be there whether you remove power for
5 minutes or 5 years.
CODES
The Door-Gard Self-Contained Access Control Systems
allow up to 120 individual user codes to be valid. Codes
may be from 1-6 digits in length and digits may be
repeated. The Master Code is always user one (1)
FORCED DOOR RELAY
Assisted by the Door Positition Sensor Input, this 1 Amp
Form-C relay will energize if the door is opened without a
valid user entry or egress input. This output can be programmed to energize for up to 15 minutes or latch. It
can be reset by a valid code entry.
PROPPED DOOR RELAY
Programming a 1 to 15 minute open door time allows the
Door-Gard to alert you to a propped door by energizing a 1
Amp Form-C relay. Assisted by the Door Position Sensor
Input, this relay will deenergize upon closure of the door.
ALARM ZONE SHUNT RELAY
Assisted by the Door Position Sensor Input, this 1 Amp
Form-C relay is energized simultaneously with the lock
release relay providing an easy means of shunting existing
door contacts. The relay will continue shunting until the
Door• Gard sees the door close; preventing nuisance
alarms (annunciate with the Propped Door Relay instead).
LOCK RELEASE RELAY
This is an 8 Amp (10 Amp surge) Form-C relay which can
be toggled (by code) or timed from 1 to 90 seconds.
DOOR POSITION SENSOR INPUT
By simple adding a normally closed magnetic door
switch, the Door• Gard system will monitor the position
of the door and immediately relock it after valid access
has been gained, preventing unwanted “tailgate” entries.
PROGRAMMING
All programming is accomplished entirely from the front
of the keypad. LED guidance makes programming easy,
and changing codes a matter of seconds for an authorized user.
TIMED EGRESS INPUT
Upon a momentary closure, this normally open loop will
trigger the main relay for the same time period as the
Master Code.
KEYPRESS FEEDBACK /
Door-Gard Self Contained Access Control Systems
will acknowledge a keypress by momentarily illuminating
the yellow LED on the indoor(i), weather resistant(w),
mullion(m) styles or momentarily sounding the sounder
in the ruggedized(r) and sealed environmental(se) styles.
This can be turned off through programming.
KEYPAD ACTIVE OUTPUT
Door-Gard Self Contained Access Control Systems can be
programmed to energize a voltage output whenever a
key is touched. This can be used to turn on lights, CCTV
camera, or notify a guard. This output is not
available if the IEI 250 Printer Interface is used.
AUDIT TRAIL
An accurate real-time audit trail can be provided by any
Access Control Series Door-Gard (except 233/ 234) with
the addition of a model 250 Printer Interface (not included). Up to 8 keypads can be monitored simultaneously.
The 250 comes with power supply and printer cable and
easily connects to any parallel printer (not included).
AUDIBLE KEYPRESS
TESTING THE KEYPAD
1. Connect the positive (+) lead of your power
supply to the terminal strip (TS1) +V input.
2. Connect the negative (-) lead of your power
supply to the terminal strip (TS1) -V
input.Turn on your power supply.

4. Press 7890#123456*. If all 12 keypresses have
been verfied, the keypad will enter self test mode.
Either the LED’s will flash or the sounder will beep 3
times,.then light or sound continuously for 3 seconds
(except on the mullion). If these responses do not
happen, try the test mode again and then call tech
support. Note: self test mode can be used when troubleshooting a keypad in the field. If you do not get the
continuous light or sound then the memory has been
corrupt and should be re-programmed with the 46
command (see option #16).
5.
Enter the master code of 1234*. The relay will
energize. Refer to programming section to program
your keypad.
NOTE:
The keypad may be programmed in your shop or at the
installation site. Programmed information is stored in nonvolatile memory so it will not be lost if power is removed.
ACCESS CONTROL DEFAULTS
Door-Gard Self-Contained Access Control Systems
are designed for easy installation in a minimum
amount of time. The following defaults have been factory programmed.
Master Code (user 1) 1234 *
Lock Release Relay will energize for 5 secs.
Keypad Active Output Off
Keypress Feedback On
Propped door relay will energize after 30 secs.
Forced door relay will energize for 10 secs.
If defaults must be changed or additional functions
are desired, please refer to the PROGRAMMING
OPTIONS Chart after you are familiar with the
PROGRAMMING section.
PROGRAMMING
1. Enter programming mode
Press 99 # (master code) * Flashes slow-
ly
1
Yellow LED
2. To Change master code
Press 1 # (new master code) * Flashes fast
Press (new master code) * Flashes slowly
If main relay time must be changed,
substitute option 2 from Programming
Options chart for step 2 above.
3. To Add/change second code
Press 2 # (new user code) * Flashes fast
Press (new user code) * Flashes slowly
4. To Add/change third code
Press 3 # (new user code) * Flashes fast
Press (new user code) * Flashes slowly
5. Up to 120 codes may be added in this fashion
6. Exit programming mode
Press * Out
3
NOTE:
• 1 Door•Gard Self-Contained Access Control
Systems are factory programmed with a
master code of 1234 *.
• 2 Some Door•Gard products contain a sounder in
place of the yellow LED. In these products the
flashing is replaced by a beeping.
• 3 The master code is always user 1.
• The master code allows access to the
programming mode & activates the main relay.
• All codes must be followed by the *.
• Codes may be from 1-6 digits in length, and digits
may be repeated.
• If the master code is forgotten or does not seem to
be working, momentarily remove the programming
jumper (or push SW1 on the SE style, see wiring
diagram for location) to enter programming mode
and go to option #16 and default keypad.
• If the yellow LED lights (or sounder sounds) solid
while in programming mode an error has occurred.
Press * to clear (yellow LED should flash or sounder
sound) and start over from step 2 or 3 above.
PROGRAMMING OPTIONS CHART
2
If the pre-programmed default values must be changed
or additional functions are desired, the following
options may be programmed

.
1. Enter programming mode
2. Change master code/set main relay time
1
( time) # 1 # (new code) * (new code)
*
Example: Master code of 4321/relay time of 10 seconds Press 10 # 1 # 4321 * 4321 *
(user number) # (new code) * (new code)
*
4. Add/change user code to toggle main relay
1
(00) # (user number) # (new code) * (new code)
*
6. Turn keypress feedback/audible keypress on
7. Turn keypress feedback/audible keypress off
8. Turn yellow LED/sounder on with relay
9. Turn yellow LED/sounder off with relay
12. Turn keypad active on
2
13. Turn keypad active off
14. Set propped door time
3
15. Set forced door relay time
3
16. Erase keypad memory/reset defaults
NOTES:
1
Time must always be represented by 2 digits. Example: 5 seconds = 05.
Latching /toggle is accomplished by entering a time of 00
2
Keypad active is a negative voltage output (sink) available
on terminal (or wire) marked WB (see wiring diagrams for location).
3
Propped Door and Forced Door times must be programmed in intervals of
10 seconds. ie. 10, 30, 60, ... up to 900 seconds.Forced door time of 00 will latch output, until reset by code.

INTERNATIONAL ELECTRONICS, INC.
427 TURNPIKE STREET, CANTON, MA
800-343-9502 , 617-821-5566
SELF CONTAINED ACCESS CONTROL SYSTEM STYLES:
232i-INDOOR STYLE
• Flushmount indoor design.
232w-WEATHER RESISTANT STYLE
• Flushmount outdoor design.
232r-RUGGEDIZED STYLE
• Weatherproof self-contained metal housing.
• Vandal resistant.
• Cast metal housing suitable for wall, post or
gooseneck mounting.
• Available in White or Black.
232se-SEALED ENVIRONMENTAL STYLE
• Weatherproof self-contained metal housing.
• Vandal resistant.
• Small design suitable for residential, commercial
and industrial applications.
232m-MULLION STYLE
• Weather resistant metal housing.
• Two-piece design with secured electronics.
• Narrow housing suitable for aluminum
door frame mounting.
• Available in Bronze or Satin Aluminum.
233 CARD READER SYSTEM
• Weatherproof metal housing.
• Two-piece design with secured electronics.
• Narrow style suitable for aluminum door frame mount-
ing.
• Uses any ABA standard track II magstripe card.
• 120 users.
234 KEYPAD CARD READER SYSTEM
• Weatherproof metal housing.
• Uses any ABA standard track II magstripe card.
• Access via card, keypad or both.
• 60 users.
ACCESSORIES:
DATA LOGGING
• IEI-250 P
tion
inputs and outputs for up to 8 Door•Gard
Keypads. Interfaces
with any parallel printer for user/door activity logging.
INSTALLATION
•
IEI-280 WEATHERPROOF SURFACE BACK BOX.
• IEI-281 F
• IEI-290 12 VDC
• IEI-293 T
relays.
Converts transistor outputs to dry contacts (for use
with
Command and Control indoor, weather resistant and
mullion
styles).
OTHER DOOR-GARD PRODUCTS FROM IEI
CONTROL PANEL INTERFACE SERIES
COMMAND & CONTROL SERIES KEYPADS
Please call to request more information.
LIMITED WARRANTY
International Electronics, Inc. (IEI) warrants its products to be free from defects
in material and workmanship, when they have been installed in accordance with
the manufacturer’s instructions, and have not been modified or tampered with.
IEI does not assume any responsibility for damage or injury to person or property due to improper care, storage, handling, abuse, misuse, normal wear and tear,
or an act of God.
IEI’s sole liability is limited to the repair or (at IEI’s option) the replacement of
the defective product or part when sent to IEI’s facility (freight and insurance
RINTER INTERFACE
provides power, communica-
LUSH MOUNT BACK BOX
PLUG-IN POWER SUPPLY
HREE RELAY PLUG--IN BOARD
.
FAX INFORMATION CENTER 617-821-0734 (FROM YOUR FAX MACHINE)
. 300MA.
with FORM C, 1 Amp
MAGNETIC STRIPE CARDS –
Track II encoded, low coercivity cards.
• IEI-2010 – Pack of 10 cards.
• IEI-2025 – Pack of 25 cards.
TAMPER PROTECTION
• IEI-282 T
• IEI-283 S
(included)
AMPER SWITCH
ECURITY MODULE
detects faceplate removal.
responds to tamper switch
and cuts all in/out power to the door lock. Wires can’t
be
crossed to unlock door. Must be reset from inside the
protected area.
• IEI-289 T
• IEI-267 1/4”
• IEI-270
ADAPTER SOCKET
• IEI-288 T
charges prepaid), after first obtaining IEI’s Return Merchandise Authorization.
IEI will not be liable to the purchaser or anyone else for incidental or conse-
quential damages arising from any defect in, or malfunction of, its products.
This warranty shall expire two years after shipping date for DOOR-GARD
keypads.
Except as stated above, IEI makes no warranties, either express or implied,
as to any matter whatsoever, including, without limitation to, the condition of its
products, their merchantability, or fitness for any particular purpose.
AMPER SCREWS
DRIVER
.
AMPER SCREWS
- TRI-
HEAD
- TRI-
HEAD
- A
LLEN WITH PIN
.
.
.
MADE IN U.S.A.
605-0232
REV. 1.04