THIS PAGE INTENTIONALLY BLANK
2 77144 Issue 8 August 2009
DOMINO C-SERIES plus PRINTER
MANUAL
This manual, Part No. 77144, is for use with the Domino C6000, C6000(i,) C6000MF, C6000v, C3000, C3000X, C1000, C1000X
For further printer maintenance information, call Domino.
For sales, service and inks enquiries, please contact:
Domino Printing Sciences plc Domino Amjet Inc
Bar Hill 1290 Lakeside Drive
Cambridge CB3 8TU Gurnee IL. 60031
Tel: +44 1954 782551 Tel:+1 847 244 2501
Fax: +44 1954 782874 Fax:+1 847 244 1421
All rights reserved. No part of this publication may be reproduced, stored on a retrieval system, or transmitted in any form, or by any means, electronic, mechanical, photocopying, recording or otherwise, without the prior permission of Domino Printing Sciences plc.
Domino Printing Sciences plc has a policy of continuous product improvement, the Company therefore reserves the right to modify the specification contained in this manual without notice.
© Domino Printing Sciences plc 2009
plus Printers.
77144 Issue 8 August 2009 3
C-SERIES plus

EC DECLARATION OF CONFORMITY

(in accordance with ISO/IEC 17050-1)
No. 77144/1
Issuer’s name: Domino UK Ltd.
Issuer’s Address: Bar Hill, Cambridge CB3 8TU
Object of the declaration: Domino C1000, C1000X, C3000, C3000X,
C6000, C6000(i,) C6000v and C6000MF Printers
The object of the declaration described above is in conformity with the requirements of the following documents:
EN 61000-6-4:2007 Electromagnetic Compatibility (EMC). Generic Standards. Emission standard for industrial environments.
EN 61000-6-2:2007 Electromagnetic Compatibility (EMC). Generic Standards. Immunity Standard for industrial environments.
EN 55022-1 1998 Class A : Electromagnetic Compatibility (Radiated).
EN 60950:2000 Safety of Information Technology Equipment.
2006/95/EC : Low Voltage Directive.
2004/108/EC : EMC Directive.
Signed for and on behalf of:
Domino UK Ltd. Bar Hill, Cambridge,
August 2009
Pete Jakes
OCC Technical Manager
4 77144 Issue 8 August 2009

CONTENTS

Page
EC DECLARATION OF CONFORMITY . . . . . . . . . . . . . . . . . . . . . . . . . 4
SAFETY INFORMATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Safety Recommendations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Fire safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Ink . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Eye contact . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Skin contact . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Ingestion . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Inhalation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Storage and Disposal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
INTRODUCTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
PRINTER SPECIFICATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Print Head (Remote) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Control Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Base . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Data Input . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Environment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Base Unit Connectors (MHB) . . . . . . . . . . . . . . . . . . . . . . . . 15
BASIC OPERATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Base Unit Mounting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
Dual Mounting Bracket . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
Control Unit Head Mounting . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
Control Unit Height Adjustment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
Rotating the Remote Head 90° - C3000X and C1000X Only . . . . . . . . . 28
Printing at Angles - C6000I Only . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
PRINT HEAD SETUP – C6000v ONLY . . . . . . . . . . . . . . . . . 32
Setup Procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
Printing at Angles - C3000X and C1000X Only . . . . . . . . . . . . . . . . . . . 34
Head Mounted Box Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
Ship Cap Attachment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
Releasing the Air Flow Vent . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
77144 Issue 8 August 2009 5
Replacing an Ink Bottle . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .39
200ml Base . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .40
2 Litre Base . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .41
Interconnections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .43
Base Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .43
Control Units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .45
Powering Up . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .47
Priming the Print Head(s) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .49
C6000v Priming . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .50
Priming a Rotated Head - C3000X and C1000X only . . . . . . . . . .51
Auto Prime . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .52
Number of Prints . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .52
Duration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .52
Timed . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .52
Event Driven . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .52
Control Unit Keypad Layout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .53
Basic Interface Controls . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .55
Functions and Menus . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .56
Keypad Functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .57
Function Keys - C6000 MF Only . . . . . . . . . . . . . . . . . . . . . .58
LCD Screen Icons - C6000 MF Only . . . . . . . . . . . . . . . . . . . .58
LCD Screen Icons . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .60
Interface Map . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .63
Setting a Print Job . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .65
Printing a Default Test Message . . . . . . . . . . . . . . . . . . . . . . . . . . .68
Printing a Saved Message . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .69
Deleting a Saved Message . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .71
PROGRAMMING THE PRINTER . . . . . . . . . . . . . . . . . . . . . . . . . . . . .72
Selecting a Language . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .72
Setting the Clock . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .73
Rollover Time . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .75
Enter Number of Shifts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .76
Checking Current Box Count . . . . . . . . . . . . . . . . . . . . . . . . . . .78
Erasing the Control Unit Memory . . . . . . . . . . . . . . . . . . . . . . . .79
6 77144 Issue 8 August 2009
Print Direction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 80
Orientation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 81
Ink Cost Calculator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 81
Variables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 82
Prompted Variable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 82
External Variable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 82
External Setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 83
Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 85
Message Revert . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 85
Communications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 85
Action Comms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 85
Echo Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 85
Satellite Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 85
Switches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 85
Shaft Encoder . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 85
Shaft Encoder Test . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 86
Screen Saver . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 86
Acknowledgement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 86
Record Change . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 86
Bottle Out . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 86
Extra Port . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 87
Retrieve Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 87
Sensor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 87
Auto Prime . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 87
IP Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 87
FORMATTING MESSAGES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 88
Creating a Message . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 88
Edit Which Message? Sub-Menus . . . . . . . . . . . . . . . . . . . . . . 90
Select Alternative Font . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 91
Entering Text . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 92
Message Layout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 97
Adding Spaces . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 99
Saving a Message . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 100
Message Attributes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 101
Edit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 101
Entering a Sell By Date . . . . . . . . . . . . . . . . . . . . . . . . . . . . 101
77144 Issue 8 August 2009 7
Real Time Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 103
Counting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .107
Character Map . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .109
Bar Codes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .110
Creating a Bar Code . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .114
Data Matrix Codes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .115
QR Codes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .116
Logos (Graphics) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .118
ADJUSTING PARAMETERS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 120
Message Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 120
MAINTENANCE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 129
Routine Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 129
Daily Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 130
Changing the Ink Collection Sponge . . . . . . . . . . . . . . . . . . . . . .131
Every 6 Months . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .133
Cleaning the Nozzle Plate . . . . . . . . . . . . . . . . . . . . . . . . . . . . .135
C6000v Head Cleaning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .135
Relocating the Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 136
C1000X & C3000X PRINT HEAD POSITIONING . . . . . . . . . . . . . . . . 137
DIMENSION DRAWINGS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 139
TROUBLESHOOTING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 159
OPERATOR NOTES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 164
Message Notes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 164
INDEX . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 167
8 77144 Issue 8 August 2009

SAFETY INFORMATION

SAFETY INFORMATION

SAFETY RECOMMENDATIONS

Before proceeding with installation, using or maintaining the printer, please read this section of the manual carefully.
Domino UK Ltd. shall not be liable against any damage or problems that arise from the use of any options or consumable products other than those designated as original Domino UK Ltd. or Domino UK Ltd. approved products.

Fire safety

The C-Series range of inks are not classed as flammable. In the event of an electrical fire, combustion of the ink may produce toxic and irritating vapours. Locating the printer in a well ventilated location is highly recommended. The inks are also sensitive to ignition by electrostatic discharge, precautions must be taken to prevent this form of ignition occurring.
Please refer to the Domino Safety Data Sheet (SDS) for further details.

Maintenance

WARNINGS: (1)When performing any maintenance tasks that
involve the disassembly of any part, ensure the mains power is removed.
(2)Ink contact with the eyes must be avoided,
therefore eye protection must be worn whenever there is risk of ink splashing or misting.
CAUTION: The printer must always be kept upright, with the keyboard facing
upwards. During transit and in general handling, the printer should not be tilted by more than 15 degrees. When installed, the underside of the printer should be as close to horizontal as possible, so that the printing nozzles are in a vertical line (not applicable to remote heads). The printer should never be subjected to knocks or vibration.
If damage occurs to the mains plug or cable, replace immediately by contacting your local Domino office.
77144 Issue 8 August 2009 9
SAFETY INFORMATION
INK
The use of ink other than supplied by Domino UK Ltd.will almost certainly result in the damage of the print head.
When handling ink or cleaning ink spillages, care should be taken to avoid contact with skin or eyes.
Protective glasses and gloves must be worn. In the event of contact with skin, eyes, or ingestion, follow the first aid instructions below and refer to the relevant Safety Data Sheet (SDS).

Eye contact

Flood the affected eye for 15 minutes with saline solution (or clean water if saline solution is not available), taking care not to allow the water to run into the unaffected eye. Medical aid must be obtained immediately.

Skin contact

Remove contaminated clothing. Wash skin with water. If symptoms develop, obtain medical attention.

Ingestion

Wash out mouth with water and give 200-300ml of water to drink. Do not induce vomiting. Obtain medical advice.

Inhalation

Remove patient from exposure, keep warm and at rest. Obtain medical attention if ill effects occur.

Storage and Disposal

If storing any ink, containers should be tightly closed. Keep ink away from oxidising agents and precautionary measures should be taken against contact with static discharges.
Disposal of any ink containers or ink spillage’s should be in accordance with local, state or national authority legislation.
10 77144 Issue 8 August 2009

INTRODUCTION

INTRODUCTION
The C6000(i), C6000v, C3000(X) and C1000(X) are the latest in high resolution ink jet case coders, capable of printing up to 8 lines of text, graphics, various barcodes, box counts and time/date functions, all from its stand alone unit. The text ranges from a maximum character height of:
C6000(i): 70mm to a minimum of 8mm
C3000(X): 35mm to a minimum of 4mm and
C1000(X): 17mm to a minimum of 2mm,
and is editable with various formats.
The (X) designates that the printer has a remote print head (attached to the control unit via a conduit). The (i) designates a remote inclined print head (also attached to the control unit via a conduit), this can be used where a conveyor is not horizontal. Unless otherwise stated in this manual, the information refers to all variants.
The maximum recommended printing speed is up to 144 metres per minute with four different font heights available.
77144 Issue 8 August 2009 11
INTRODUCTION
THIS PAGE INTENTIONALLY BLANK
12 77144 Issue 8 August 2009

PRINTER SPECIFICATION

PRINTER SPECIFICATION

Print Head (Remote)

Standard Finish: Grained 304 Stainless Steel
Dimensions: (width x height x depth):
Conduit Length: (128 & 256 dot): 1.0m

Control Unit

Standard Finish: Grained 304 Stainless Steel
Dimensions: (width x length x height):
Control Panel Material: Polyester Membrane Touch Panel
(128 dot): 39.5mm x 71.5mm x 65mm
(256 dot): 59.5mm x 90mm x 90mm
(500 dot inclined): 79mm x 114mm x 187mm
(500 dot): 79mm x 170mm x 114
(500 dot only): 1.5m
(128 dot): 113mm x 295mm x 125mm
(256 dot): 113mm x 295mm x 146mm
(500 dot): 113mm x 370mm x 160mm
77144 Issue 8 August 2009 13
PRINTER SPECIFICATION

Base

Standard Finish: (200ml) Grained 304 Stainless Steel
(2 litre) Grained 304 Stainless Steel
Grained 304 Stainless Steel
Dimensions: (width x
(200ml): 152mm x 360mm x 108mm
length x height):
(2 litre): 228mm x 507mm x 139mm
Dimensions (incl. bracket):
289mm x 520mm x 252mm
(width x height x depth):
Weight (no fluids): 16.3kg

Data Input

Interface Rate
RS232: 300 - 115200 Baud Software Configurable
TCP/IP: 10BaseT

Environment

Temperature Range (working):
Humidity: 10 - 90% RH
Electrical Supply: Single Phase, 90-240V @ 50-60 Hz
+10
ºC to +40ºC (50ºF to 104ºF)
14 77144 Issue 8 August 2009
PRINTER SPECIFICATION

Base Unit Connectors (MHB)

Power Connector: IEC
Product Detector Connector: DIN 5-way 180
Shaft Encoder Connector: DIN 4-way
Shaft Encoder Input: PNP
RS232 Connector: 9-way D
Bottle Empty Alarm Connector: DIN 5-way 240
Ink Out Alarm Connector: DIN 5-way 240
Base and Head Connections
Product Detector Connector: DIN 5-way 180
TCP/IP Connector: RJ45
“Bottle Out” Alarm Connector: DIN 5-way 240 (2 litre base only)
Shaft Encoder Connector (via Accessory Connection Box (ACB)): DIN 4-way
Shaft Encoder Input: PNP
RS232 Connector (via ACB) 9-way D
Ink Out Alarm Connector (via ACB) DIN 5way 240
Power Connector IEC
77144 Issue 8 August 2009 15

BASIC OPERATIONS

Door Latch
Power Switch
Multi-head Base Unit
Ink Bottle (behind door)
Mounting Bracket
BASIC OPERATIONS
16 77144 Issue 8 August 2009
2 Litre Base Unit
BASIC OPERATIONS
77144 Issue 8 August 2009 17
BASIC OPERATIONS
200ml Base Unit
18 77144 Issue 8 August 2009
Alphanumeric
keypad
LCD display
Control unit
Control unit
power cable
C6000(i) Control Unit
C6000i Control Unit and Print Head
Conduit
Control unit
Print head
Product
Detector
BASIC OPERATIONS
77144 Issue 8 August 2009 19
Keypad
LCD display
Control unit
Control unit
power cable
C6000MF - Control Unit
Product
Detector
BASIC OPERATIONS
20 77144 Issue 8 August 2009
LCD display
Control unit
Control unit power cable
C3000(X) Control Unit
C3000X Control Unit and Print Head
Conduit
Print head
Control unit
Alphanumeric
keypad
BASIC OPERATIONS
77144 Issue 8 August 2009 21
Alphanumeric
keypad
LCD display
Control unit
Control unit
power cable
C1000 (X) Control Unit
C1000X Control Unit and Print Head
Conduit
Print Head
Control unit
Product
Detector
BASIC OPERATIONS
22 77144 Issue 8 August 2009
Stand
Multi-head Base Stand
BASIC OPERATIONS

BASE UNIT MOUNTING

The base unit and control units must be mounted either on a stand or onto the conveyor.
77144 Issue 8 August 2009 23
BASIC OPERATIONS
Conveyor
24 77144 Issue 8 August 2009
BASIC OPERATIONS
Dual Mounting
Bracket
Stand

DUAL MOUNTING BRACKET

Domino can supply a mounting bracket to enable two print heads to be mounted next to each other on the stand.
77144 Issue 8 August 2009 25
BASIC OPERATIONS
Views show C6000

CONTROL UNIT HEAD MOUNTING

Note: It is recommended that control units are mounted on stands.
(1) To mount or dismount the control unit head,
loosen the fixing knob on the top of the vertical mounting post.
(2) Mount the control unit by gently moving the
unit’s slide bar over the loosened clamping plate. Ensure that the unit is well supported during this operation.
(3) Ensure the front of the unit is facing the
conveyor belt as shown. To dismount the unit, move the slide bar back off the loosened clamping plate, ensuring that all connections to the control unit are unplugged.
(4) When the control unit has been moved to
the required position, tighten the fixing knob at the top of the vertical mounting post.
26 77144 Issue 8 August 2009
BASIC OPERATIONS
Base of Head and Base of
Control Unit must be at
same height when printing
vertically

CONTROL UNIT HEIGHT ADJUSTMENT

(1) The vertical mounting post on the printer
base unit can be adjusted up or down to the required height. This operation should be carried out with the control unit in place.
Note: Picture shown with control unit removed for
clarity.
(2) Tighten the fixing knob on the front of the
vertical column so that it is holding the vertical mounting post securely in place.
CAUTION: The C6000i print head and
control unit must be adjusted to the same height (bases) and must be kept in the same environment. Refer to page 30 for printing at angles.
(3) To Adjust the C6000i print head, slacken the
fixing knob and adjust to the required height.
77144 Issue 8 August 2009 27
BASIC OPERATIONS
ROTATING THE REMOTE HEAD 90° ­C3000X AND C1000X ONLY
(1) To set a remote head to print down, the head
must be set to the correct height to provide adequate tolerance for the print surface to pass beneath it. By adjusting the length of the bracket arm, the position of the message can be placed accurately on the print surface.
(2) Before setting the print the head must be
rotated. The pivot point of the head will need switching as follows; release the bracket screws on either side of the head, ensure that the head is held securely and the ship cap is attached.
(3) Whilst holding the head, gently rotate it to
the position indicated.
(4) There are two sets of fixings on either side of
the head, use the ones shown.
28 77144 Issue 8 August 2009
BASIC OPERATIONS
(5) There are two pivot points on the remote
head bracket. The top right position is for forward and angled printing. The lower left pivot point (indicated) is the mounting position for printing down.
(6) Align the fixing holes and the pivot point on
the mounting bracket and refit the screws enough to secure the head. Do not over tighten.
(7) The sensor must also be inverted by
slackening the bottom left screw on the sensor bracket and pushing the sensor up so that it is facing down, ensuring that the sensor is not triggered by the conveyor.
(8) The remote head mounting plate must be
removed and turned over to compensate for the drop in height due to the new pivot point. The mounting plate has a bend on one side that increases the head height by 9mm, see step (3) on page 34. To do this, dismount the control unit, remove and flip the plate and remount the unit to the vertical pillar.
77144 Issue 8 August 2009 29
BASIC OPERATIONS
0o TO +25
o
0o TO +25
o
Controller
Print head

PRINTING AT ANGLES - C6000i ONLY

When printing horizontally, the controller should be mounted so that the bottom face is level with the bottom face of the print head.
The print head can print up to a maximum angle of 25 angle is maintained - i.e. the bottom dot position should be higher than the bottom of the controller face. To achieve this, the print head should be mounted on either side of the mounting post as follows:
Note: Before repositioning the mounting
brackets, ensure the ship cap has been fitted and the vent valve is shut. Ensure that the conduit does not become twisted whilst the print head is removed from its mounting.
(1) Remove the bracket and print head
from the mounting post, then remove the bracket from the print head. Take care to retain screws and nuts.
(2) Mount the bracket on the other
side of the print head and refit to the mounting post. Adjust the print head to the required angle (up to a maximum of 25
º as long as a positive
º).
30 77144 Issue 8 August 2009