Please read this instruction manual carefully before installation and first
use, and store it in a safe place. If you pass on the product to another
person, hand over this instruction manual along with it.
NOTE
You can find details on the operation in the manual.
Safety instruction: Failure to observe this instruction can cause fatal or
serious injury.
CAUTION!
Safety instruction: Failure to observe this instruction can lead to injury.
!
NOTICE!
A
Failure to observe this instruction can cause material damage and impair
the function of the product.
NOTE
Supplementary information for operating the product.
I
2Safety instructions
The manufacturer accepts no liability for damage in the following cases:
•Faulty assembly or connection
•Damage to the product resulting from mechanical influences and excess voltage
•Alterations to the product without express permission from the manufacturer
•Use for purposes other than those described in the operating manual
4
EN
RMLT9xxxSafety instructions
2.1General safety
WARNING!
!
•Never open the absorber unit. It is under high pressure and can cause
injury if it is opened.
•Ensure clean and residue-free handling if silicon sealant or similar is
used. There is a risk of fire if silicone filaments come into contact with
hot parts or naked flames.
•Do not operate the device if it is visibly damaged.
•If the AC power cable for this device is damaged, it must be replaced
by the manufacturer, customer service or a similarly qualified person in
order to prevent safety hazards.
•Never use a naked flame to check the device for leaks.
•This device may only be repaired by qualified personnel. Inadequate
repairs may cause serious hazards.
•Only use propane or butane gas (not natural gas).
•Always operate the device at the pressure shown on the type plate.
Use a DIN-DVGW-approved pressure regulator with a fixed setting in
accordance with DIN EN 12864.
•Dismantle all doors for the disposal of the old device and leave the
shelves in the device to prevent accidental enclosure and suffocation.
!
CAUTION!
•Danger of crushing! Do not put your fingers into the hinge.
•Before starting the device, ensure that the power supply line and the
plug are dry.
5
EN
Scope of deliveryRMLT9xxx
NOTICE!
A
•Only hold the device at the body of the refrigerator during transport.
Never hold the device on the oven, the cooling fins, the gas pipes, the
door or the control panel.
•Make sure that the refrigerator circuit is not damaged during transpor-
tation. The refrigerant in the refrigerator circuit is highly flammable.
In the event of any damage to the refrigerator circuit:
–Avoid naked flames and sparks.
–Air the room well.
•Do not install the device near naked flames or other heat sources
(heaters, direct sunlight, gas ovens etc.).
•Danger of overheating!
Always ensure sufficient ventilation so that the heat generated during
operation can dissipate. Make sure that the device is sufficiently far
away from walls and other objects so that the air can circulate.
•Check that the voltage specification on the type plate is the same as
that of the power supply.
•Do not open the refrigerant circuit under any circumstances.
•Only use the AC connection cable supplied to connect the device to
the AC mains.
•Only use cables with a suitable size.
•Never pull the plug out of the socket by the connection cable.
•The device may not be exposed to rain.
3Scope of delivery
•Refrigerator-oven combination
•Ice-cube tray
•Operating manual
•Installation manual
6
EN
RMLT9xxxAccessories
4Accessories
Available as accessories (not included in the scope of delivery):
Description
Fan kit for boosting the cooling capacity at high ambient temperatures
Ventilation grille
Winter cover for the ventilation grille
Truma AK3 roof flue
Truma flue pipe
Divider, bottle finger (RMLT9430/9431/9435 only)
Shelf with safety edges (RMLT9430/9431/9435 only)
Door shelf locking
Bottle holder for door shelf locking
Shelf locking
All the accessories are available from specialist dealers. If you have any questions,
please contact the dealer or your service partner directly.
5Intended use
This refrigerator-oven combination is designed for installation in caravans or motorhomes.
The refrigerator is only suitable for cooling, freezing and storing foodstuffs. The
refrigerator is not intended for the proper storage of medicine.
The refrigerator is designed to be operated on a DC power supply and an AC socket
and can be independently powered by liquid gas (propane or butane). The refrigerator may not be run on natural gas or city gas.
The oven is only suitable for cooking and baking foodstuffs.
The oven is designed to be run on liquid gas (propane or butane). The oven may not
be run on natural gas or city gas.
7
EN
Installing the refrigerator-oven combinationRMLT9xxx
420 mm615 mm
1605 mm
312 mm1293 mm
RMLT9330, RMLT9331, RMLT9335
1
6Installing the refrigerator-oven
combination
6.1Preparing the installation
When installing the refrigerator-oven combination, note the following:
•To enable the refrigerant to circulate properly, the refrigerator may not exceed an
angle of 3°.
To do this, park the vehicle on a level surface and check to see if the ice-cube tray
is flat in the refrigerator.
•The refrigerator-oven combination must be installed so that it is easily accessible
for service work, easy to de-install and install, and easily removed from the
vehicle.
•The distance between the refrigerator-oven combination and the rear wall must
be min. 15 mm – max. 25 mm.
•The refrigerator-oven combination must be installed in a recess so that it stands
firm when the vehicle is in motion. Note the following dimensions here
(HxWxD inmm):
–RMLT9330/9331/9335: 1605 x 420 x 615 (fig. 1)
8
EN
RMLT9xxxInstalling the refrigerator-oven combination
2
RMLT9430, RMLT9431, RMLT9435
468 mm
312 mm1293 mm
1605 mm
555 mm
–RMLT9430/9431/9435: 1605 x 468 x 555 (fig. 2)
9
EN
Installing the refrigerator-oven combinationRMLT9xxx
6
2
3
4
5
1
10 mm
≥ 170 mm
min.15 mm –
max. 25 mm
3
•The outer wall must be fitted with an air inlet vent (fig. 3 1) and an outlet vent
(fig. 3 2) with ventilation grilles so that the heat generated can be easily
released to the outside:
–Air inlet vent: Fit the ventilation grille as flush as possible to the floor of the
installation niche with a minimum cross-section of 400 cm².
–Outlet vent: fit as far above the refrigerator as possible.
10
EN
RMLT9xxxInstalling the refrigerator-oven combination
≥ 1050≥ 250
< 1050
< 250
4
–The distance between the air inlet and outlet vents must be at least 1050 mm
(fig. 4).
•Fit a heat conduction plate (fig. 3 3, page 10) above the refrigerator so that the
heat does not accumulate in the vehicle.
•If the ventilation grille of the air inlet vent cannot be installed flush to the ground,
an additional inlet vent (fig. 3 6, page 10) must be provided in the floor for
releasing leaked gas.
•The distance between the top of the oven and the ceiling must be at least
170 mm (fig. 3, page 10).
•If a roof flue (fig. 3 4, page 10) is being used: Fit a detachable panel (fig. 3 5,
page 10) above the oven so that you can always reach the flue pipe.
11
EN
Installing the refrigerator-oven combinationRMLT9xxx
7
6
2
3
1
min.15 mm –
max. 25 mm
≥ 170 mm
5
•If you do not have a roof flue: Fit a panel with a ventilation grille (fig. 5 7) above
the oven.
•The distance between the top of the oven and the flue outlet of the roof flue must
be between 250 mm and 1500 mm (fig. 4, page 11).
12
Loading...
+ 28 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.