Dometic 3312026, 3312024 User Manual

Comfort Control Center 2 Thermostat
Operating Instructions
Programmable Thermostat
MODEL
3312026.XXX With Dehumidify
3312024.XXX With Out Dehumidify
TABLE OF CONTENTS
About your new thermostat
Features .....................................................................................................................2
System Conguration & Initialization ..........................................................................2
Factory preset settings ...............................................................................................3
Quick reference to control buttons..............................................................................3
Quick reference to LCD icons.....................................................................................3
Programming & Operations
ON/OFF ......................................................................................................................3
Clock setting ...............................................................................................................4
Temperature format ºF/ºC ...........................................................................................4
Inside Temperature .....................................................................................................4
Outside Temperature .................................................................................................. 4
Zone Selection............................................................................................................5
Mode Selection ...........................................................................................................5
Fan Speed .................................................................................................................. 5
Temperature Set-Point................................................................................................5
Dehumidify Setting (Select Models) ...........................................................................6
Mode description
OFF ............................................................................................................................6
Cool ............................................................................................................................ 6
Heat Pump..................................................................................................................6
Heat Strip....................................................................................................................7
Fan ............................................................................................................................7
Furnace/Aqua ............................................................................................................. 7
Auto Change Over ......................................................................................................7
Special Features
Auto Fan ..................................................................................................................... 8
Zone Control ...............................................................................................................8
Dehumidify (Select Models)........................................................................................8
Program 1 & 2 ............................................................................................................8
CANbus ......................................................................................................................9
Auxiliary Heat (Heat Pump Models Only) ................................................................... 9
Stage Select (Two Air Conditioners/Heat Pump Units)...............................................9
Stage Select (Models Equipped With Two Compressor) ............................................9
Automatic Generator Start ..........................................................................................10
Load Shed ..................................................................................................................10
Defrost Cycle (Heat Pump Models Only)....................................................................10
Compressor Time Delay .............................................................................................10
Power Interruption ......................................................................................................10
LCD Error Codes ........................................................................................................ 10
System Reset Procedure .........................................................................................11
General Information .................................................................................................12
Maintenance ..............................................................................................................12
Service .......................................................................................................................12
Congratulations! Your recreational vehicle manufacturer has equipped your RV with the most advanced RV thermostat. Your Dometic Comfort Control Center 2 thermo­stat (hereinafter referred to as the CCC 2 thermostat) has been designed for ease of operation and for many years of reliable service.
Features
Liquid Crystal Display
2 operation programs
Outdoor temperature sensing (select models)
Constant time of day display
Remote Sensor (Precise comfort control within 1º F. of set-point)
Display reminder lets you know when to service or replace lters
Up to 4 independent zones To help familiarize yourself with the operation of the CCC 2 thermostat, review the following diagrams and accompanying text that explain the functional characteristics of this system. Your CCC 2 thermostat is equipped with a liquid crystal display (LCD) that identies the mode of operation (OFF, Cool, Heat Pump, Fan, Heat Strip, Auto, & Furnace or Aqua), temperature set-point, zone identication (1, 2, 3, 4), fan speed (Auto, Low, Med, High), program 1 and 2, inside temperature, outside temperature, clock, ºF/ºC, compressor delay, lter maintenance, and dehumidify operation with humidity set point. The modes of operation viewed in the LCD will vary depending on the system installed in your RV.
System Conguration & Initialization
The installer of your system will set the required system DIP switches to the ON position. In order for the CCC 2 thermostat to recognize the system zones, type of units installed and their options, a system reset must be done. Once the system is completely installed, do a system reset.
Make sure the CCC 2 thermostat is in the OFF condition. See page 3, Quick reference to control buttons.
Simultaneously press and hold the MODE and ZONE buttons. See page 3, Quick reference to control buttons.
The LCD will display “IniT” and all available zones.
Release the MODE and ZONE buttons.
Press the ON/OFF button to exit system set up.
The furnace ON/OFF temperature differential should be set at this time. See “Pro- gramming & Operations” on page 7 for further information on furnace mode dif­ferential setting. Any time a system reset occurs, the factory default settings are restored. See “Fac- tory Preset Settings” on page 3. In the unlikely event of CCC 2 system memory loss or dip switch setting change, the CCC 2 thermostat will require a system reset. Refer to page 11 for system reset procedure.
2
Your Dometic CCC 2 thermostat has been pre-programmed. Review settings below and adjust the settings to your personal comfort level. Note: Any time the CCC 2 is in an idle stage (not illuminated) you will need to wake it up by pressing any button on the CCC 2 before it will recognize a new setting at-
tempt.
Factory Preset Settings
All Zones
Function Setting
Time of Day (Clock) — — —
Each Zone
Relative Humidity 50%
Heating 68ºF / 20ºC
Cooling 72ºF / 22ºC
Automatic 70ºF / 21ºC
Fan Speed Auto
Mode Off
Humidity (select models) Off
Factory Preset Settings Each Zone
Program 1
Function Setting
Heating 68ºF / 20ºC
Cooling 72ºF / 22ºC
Automatic 70ºF / 21ºC
Fan Speed Auto
Mode Off
Time 8:00 AM
Program 2
Heating 68ºF / 20ºC
Cooling 72ºF / 22ºC
Automatic 70º / 21ºC
Fan Speed Auto
Mode Off
Time 10:00 PM
Quick reference to LCD icons
Zone
Temperature, Humidity Set-Point or Error Code
Fan Speed
Compressor Delay
Programming & Operations
ON/OFF
Operation Mode
Humidity Set-Point Percent
Time of Day
Dehumidify Icon
Program
Clean or Replace Filter
Quick reference to control buttons
Press to select zone
Press to select On and OFF
Press to select fan speed
Press to set clock
Press to select mode
Press to select program 1 or 2
Press to increase temperature or humidity set-point
Press to display rela­tive humidity set-point (Select Models)
To turn ON the CCC 2 thermostat rst press any button to wake up the CCC 2 ther­mostat. Then press and release the ON/OFF button. The LCD will display the last programmed settings. To turn OFF the CCC 2 thermostat press the ON/OFF button and release. Only the time of day will display when the CCC 2 thermostat is in the OFF condition.
Press to display inside temperature
Press to display outside temperature
Press to select temperature format
Press to decrease temperature or humidity set-point
3
Clock Setting
Inside Temperature
Press the CLOCK button to initiate the clock setting sub-menu on the CCC 2 ther­mostat. When in this menu, the hour digits will ash rst. The hour can be adjusted using the or buttons. Press the CLOCK button again and the minute digits will ash, allowing the minute setting to be adjusted using the or buttons. Press it a third time and the AM or PM icon will ash, allowing the AM or PM setting to be adjusted using the or buttons. Press it one more time to store the new time in memory and exit the clock setting sub-menu.
Temperature format ºF / ºC
Press and hold the INSIDE TEMP button and the LCD will display the current inside temperature recorded at the CCC 2 Thermostat (or at the optional remote indoor temperature sensor) instead of the temperature set-point. The LCD will also display
“IN” to indicate that the inside temperature is being displayed. When the INSIDE TEMP button is released, the LCD will return to the programmed temperature set-
point.
Outside Temperature
Press the ºF / ºC button to switch between Fahrenheit and Centigrade format. ºF indicates Fahrenheit and ºC indicates Centigrade
Press and hold the OUTSIDE TEMP button and the LCD will display the current outside temperature recorded at the outdoor temperature sensor in place of the tem­perature set-point. The LCD will also display “OUT” to indicate the outside tempera­ture is being displayed. When the OUTSIDE TEMP button is released, the LCD will return to the programmed temperature set-point.
4
Loading...
+ 8 hidden pages