Doepke DWS 1 Operating Instructions Manual

Doepke
1. Allgemeines ..........................................2
2. Wichtige Hinweise vorab.......................2
3. Kodierung .............................................2
4. Montage................................................2
5. Inbetriebnahme.....................................3
6. Garantie................................................3
7. Technische Daten.................................3
15.Anschlussschema / Conn. Diagram......6
Table of Contents
8. General Information..............................4
9. Important Notes in Advance .................4
10.Coding ..................................................4
11.Installation ............................................4
12.Putting into Service...............................4
13.Guarantee.............................................5
14.Technical Data......................................5
15.Anschlussschema / Conn. Diagram .....6
Dupline
Wasserstoppsensor DWS 1
DWS 1 Water Stop Sensor
Bedienungsanleitung
Operating Instructions
3931247/2009.03/B
Doepke
Bedienungsanleitung
Wasserstoppsensor DWS 1

1. Allgemeines

Der Wasserstoppsensor DWS 1 ist eine Ko mponente des Dupline Installationssystems und ermöglicht die Erkennung von Wassereinbruch und die Übertragung des Alarms auf dem Dupline-Bus. Der Sensor verfügt über zwei Dupline-Kanäle: dem Alarmkanal u nd ein em Kan al für d ie
Deutsch
Übertragung eines Lebenszeichens. Während der Alarmkanal nur im Falle eines Was­sereintritts aktiviert wird, ist das Lebenssignal permanent eingeschaltet .

2. Wichtige Hinweise vorab

• Die Installation darf nur von einer autorisierten Fachkraft vorgenommen werden.
• Dieses Gerät ist ausschließlich für den Betrieb an den Signalleitern des Dupline-Bus­systems geeignet, die nach den Bedingungen für Schutzkleinspannung (siehe VDE 0100, Teil 410 sowie EN 50090-9-1) installiert wurden. Andere Signalspannun­gen können - trotz umfangreicher Schutzmaßnahmen im Gerät - zur Zerstörung des Gerätes und Gefährdung von Menschen führen. Weitere Hinweise finden Sie in der Dupline Planungshilfe.
• Der Sensor erfüllt die Norm IP 67, ist also gegen kurzzeitiges Eintauchen ge­schützt. Er darf jedoch weder längere Zeit in Wasser eingetaucht noch zur Erkennung an­derer Flüssigkeiten eingesetzt werden.

3. Kodierung

Mit dem Handkodiergerät DHK 1 kann über den Stiftleistenanschluss jedem Eingangs­kanal jede beliebige Adresse zwischen A1 und P8 zugeordnet werden. Stecken Sie dazu die beigelegte Stiftleiste zusammen mit dem Flachstecker-Programmierkabel des DHK 1 auf den Stiftleistenanschluss und stellen Sie - ggf. durch schräghalten der Stifte
- einen ausreichenden Kontakt sicher. Die Kanalzuordnung ist wie folgt:
Kanal Beschreibung Kanal Beschreibung
1 Wasseralarm 3..8 Nicht belegt 2 Lebenszeichen (immer „Ein“)
Funktionen, die nicht benötigt werden, sollten unkodiert bleiben. Die Kodierung des DWS 1 kann ohne Versorgungsspannung sowie ohne Dupline-Signal vorgenommen werden. Sie bleibt dauerhaft erhalten, kann aber jederzeit überschrieben werden.

4. Montage

Die Montage des DWS 1 erfolgt an der Wand. Lösen Sie zunächst die abnehmbare Mon ­tageplatte (B) von der Platine (siehe K apitel15 “Anschlussschema / Conn. Diagram” auf Seite 6). Befestigen Sie dann die Montageplatte mittels zweier Schrauben so, dass de­ren Abstandslaschen den Boden berühren.
1-Inhaltsve rzeichnis
2
3931247/2009.03/B - Technische Änderungen vorbehalten!
Doepke

5. Inbetriebnahme

Bei der Installation ist das Anschlussschema zu beachten. Alle anzuschließenden Lei­tungen müssen spannungsfrei sein. Verbindungen zwischen dem Dupline-Signal und dem Erdpotenzial führen zu Störungen und sind nicht zulässig. Auf die richtige Polarität des Dupline-Signals ist zu achten. Folgende Tabelle zeigt die Anschlussbelegung:
Klemme Beschreibung Klemme Beschreibung
1 / D+ Dupline Signalleiter + (D+) 2 / D- Dupline Signalleiter - (D-)

6. Garantie

Für fachgerecht montierte, unveränderte Geräte gewähren wir ab Kauf durch den End­verbraucher die gesetzliche Gewährleistungsfrist. Die Garantie bezieht sich nicht auf Transportschäden sowie Schäden, die durch Kurzschluss oder Übe rlast ung entst ande n sind. Bei Fertigungs- und Materialfehlern, die innerhalb der Gewährleistungsfrist er­kannt werden, leistet unser Werk kostenlosen Ersatz.

7. Technische Daten

Dupline
Stromaufnahme 1,3 mA Eingangskanäle 2 Eingangssignale (Alarm/Lebenszeichen)
Ausgangskanäle Keine
Eingang
Art integriert
Nennspannung 8 VDC
Trigger-Widerstand 150 k 470 k
Betriebsspannung
Nennbetriebsspannung nicht erforderlich (aus Dupline-Signalleiter)
Anschlüsse
Art Schraubklemmen
Klemmbereich 0,4 mm 0,8 mm²
Gehäuse
Art Weißes Aufputzgehäuse
Maße 70 x 40 x 16 (B x H x T in mm)
Material ABS
Allg. technische Daten
Betriebstemperatur -20°C +50°C Schutzart / Normen IP 67
Bestellnummer, -bezeichnung 09 501 197, Wassersensor DWS 1
Min. Typ. Max.
Deutsch
3931247/2009.03/B - Technische Änderungen vorbehalten!
3
Doepke
Operating Instructions
DWS 1 Water Stop Sensor

8. General Information

The DWS 1 water stop sensor is a component of the Dupline installation system and per­mits the detection of water leakage and the transmission of the ala rm via the Dupline bus. The sensor is equipped with two Dupline channels: the alarm cha nnel and a cha nnel for the transmission of a live signal. While the alarm ch annel is activated only in the event of water penetration, the live signal is permanently switched on.

9. Important Notes in Advance

• The installation may only be carried out by an authorised technician
• This device is suitable exclusively for operating through the signal conductors of the Dupline bus system, which have been installed in accordance with the requirements for protective low voltage (see VDE 0100, Part 410, or EN 50090-9-1). Other signal voltages - even if extensive protective measures are taken - may lead to irreparable damage to the device as well as danger to people. For further guidelines refer to the Dupline Planning Aid.
• The sensor meets the requirements of the IP 67 standard and is thus protected
English
against temporary immersion. It may not, however, be immersed in water for longer periods or used for the mo­nitoring of other fluids.

10. Coding

With the DHK 1 hand encoder each channel can be assigned any address between A1 and P8 via the pin strip. To do this, plug the supplied pin strip together with the flat-plug programming cable of the DHK 1 on to the pin strip connector and ensure that sufficient contact is provided - if necessary by holding the positioning at an angle. The channe l al­location is as follows:
Channel Description Channel Description
1 Water alarm 3 ..8 not assigned 2 Life signal (always „On“)
Functions which are not required should remain uncoded. Encoding the DWS 1 requires neither a power supply nor the Dupline signal. Although the coding is permanently re­tained, it may always be overwritten.

11. Installation

The DWS 1 should be wall-mounted. First remove the mounting plate (B) from the PCB (see chapter 15 “Anschlussschema / Conn. Diagram” on page 6). Fasten the mounting plate with two screws in such a way that its spacer lugs are touching the floor.

12. Putting into Service

Observe the connection diagram when installing. All leads to be connected must be
1-Table of Contents
4
3931247/2009.03/B - The right to make technical changes reserved!
Doepke
dead. Connections between the Dupline signal and earth potential will cause malfunct ions and are not permissible. In addition check for correct polarity of the Dupline signal. The following table illustrates the connection configuration:
Terminal Description Terminal Description
1 Dupline signal conductor + (D+) 2 Dupline signal conductor - (D-)

13. Guarantee

All professionally installed, unaltered devices are covered by warranty during the statu­tory guarantee period from the day of purchase by the end user. The guarantee is not applicable to damage incurred during transport or caused by short-circu it or overloading. In the event of defects in workmanship or material, which are discovered within the guar­antee period, the company will provide a replacement free of charge.

14. Technical Data

Dupline
Current input 1,3 mA
Input channels 2 input signals (alarm / live Signal)
Output channels None
Inputs
Type integrated
Rated voltage 8 VDC
Trigger resistance 150 k 470 k
Operating Voltage
Rated operating voltage Not required (supplied by Dupline signal line)
Terminals
Type Screw terminals
Contact area 0.4 mm 0.8 mm²
Housing
Type White surface-mounted housing
Dimensions 70 x 40 x 16 (W x H x D in mm)
Material ABS
General technical data
Ambient temperature -20°C +50°C
Encl. protection type /
standards
Order number, description 09 501 197, Water sensor DWS 1
Min. Typ. Max.
IP 67
English
3931247/2009.03/B - The right to make technical changes reserved!
5
Doepke
A B

15. Anschlussschema / Conn. Diagram

Zeichnungen / Drawings
Sollten Sie Fragen zu diesem Produkt oder zum Dupline-System haben, wen­den Sie sich bitte an:
Doepke
Schaltgeräte GmbH & Co. KG Stellmacherstraße 11 D-26506 Norden, Germany Tel.: +49 (0) 4931/1806-0 Fax: +49 (0) 4931/1806-101
6
3931247/2009.03/B - The right to make technical changes reserved!
In case of queries concerning this product or the Dupline system please contact:
E-mail:
Internet:
info@doepke.de
http://www.doepke.de
Loading...