Doepfer A-197 User Manual

doepfer
System A - 100
1. Introduction
Analog Meter
A-197
A-197
In
Neg. Indicator
VU Meter
Met er
Meas . Mode
Module A-197 serves to display DC or AC voltages by means of an illuminated moving coil meter with mirror scale.
The display range is 0...+10V (resp. -5V...+5V in the offset mode).
The module features 3 different measuring methods that are selected by a toggle switch.
A LED is used as an indicator for negative voltages.
1
A-197
Analog Meter
System A - 100
doepfer
2. Overview
Controls:
1 Meter : Moving coil meter
2 Meas. Mode : Measurment mode switch
3 LED : Indicator for negative voltages at
input !
Inputs / Outputs:
! In : Measuring voltage input
(3-fold multiple)
2
doepfer
System A - 100
Analog Meter
A-197
3. Controls
1 Meter
The illuminated moving coil meter with mirror scale is used as readout for the voltage applied to socket !.
2 Measurement Mode
This switch is used to select the desired measurment mode:
Full wave rectifier
In this mode the incoming signal is rectified and smoothed with a low pass filter.
This mode is normally used to display audio si­gnals resp. AC voltages. But even DC voltages
can be measured in this mode. The display shows however the absolute value (i.e. positive voltages remain unchanged, negative voltages - e.g. -3V ­are converted into the corresponding positive vol­tages - e.g. +3V). To distinguish between positive and negative input signals LED 3 is available that lights up in case of a negative signal.
Direct mode
In this mode the incoming voltage is lead to the meter without additional electronic modifica- tion.
This mode is intended to display positive DC voltages, e.g. ADSR (A-140/141/A142), MIDI-to­CV (A-190/191), positive analog or digital random voltages (A-149-1, A-149-2), foot controller (A-177) or slowly changing Gate/Clock signals.
Offset mode (+5V Offset):
In this mode +5V are added to incoming voltage before it reaches the meter. Zero volt input corre­spond to the middle position of the display needle (i.e. +5V read out).
This mode can be used to display positive and negative voltages, e.g. a slowly swinging LFO (A-145/146/147), S&H (A-148), bipolar random vol­tages (A-118), joy stick (A-174), Theremin (A-178), light controlled CV source (A-179).
3
A-197
Analog Meter
System A - 100
doepfer
3 Neg. Indicator
The LED lights up if a negative voltage appears at the measurement input !.
4. Inputs / Outputs
! In
This socket is the measurement input of the module. It is available as a triple multiple so that the signal to be measured can be used elsewhere in the system simul­taneously.
4
Loading...