DOC Stream Motion User Manual

Page 1
Stream Motion measuring bed.
August 2015
Page 2
150828_BA STREAM-motion_DE_V15-1_2015­08-28.doc
STREAM Motion
User Manual
DOC Sleep Systems St.Gallen
Page 3
Page 2
150828_BA
STREAM-motion_DE_V15-1_2015-
08-28.doc
User Manual
Source
Version
Date
Author
Status / Changes
1
2011-06-06
SG/BM
BA_Messbett_ DE_V01_11.do c
V15_2015
-08-03
2015-08-03
TS
Changes version V15, provisional issue
V15.1
2015-08-27
TS / M. Kräutle
Changes / additions as per meeting on 2015-08­26
STREAM Motion Measuring and Adjusting Bed DOC Sleep Systems
Copyrightby TBM AutomationAG
Bahnhofstrasse 48 CH-9443 Widnau Switzerland
Tel.: +41 71 727 00 30 Fax: +41 71 727 00 39
Authors: M. Schadegg / S. Tribus / M. Kräutle Version V15.1 2015-08-27 Order No. BA_Messbett_DE_V15-1_2015-08-27.doc Subject to changes and errors
Previous issues:
Page 4
150828_BA STREAM-motion_DE_V15-1_2015­08-28.doc
User Manual Stream Motion
Purpose of User Manual
This user manual serves as a guide for the installation, parametrisation, start-up, operation and maintenance of the control system for the STREAM Motion by DOC AG.
The user manual contains parametrisation, operational and technical data for the measuring bed and the control system.
Please carefully read this user manual before installation and start-up. We accept no liability for damages caused by inappropriate handling and/or failure to observe the user manual.
This user manual was originally compiled in German.
Target Group
This user manual is designed for specialised personnel. The selection and training of the personnel who deal with the control system will be subject to particular requirements. The system may only be operated by people who have been instructed accordingly (see also safety instructions “1.4. Selection and qualifications of personnel”).
Note on Trademark
WINDOWS is a registered trademark of theMicrosoft Corporation.
Page 5
Page 4
150828_BA
STREAM-motion_DE_V15-1_2015-
08-28.doc
Contents
Inhalt
1 Safety Instructions................................................................................................................................. 5
1.1 Representation of warning signs and symbols.......................................................................... 5
1.2 Basic safety instructions ............................................................................................................... 6
1.3 Intended usage............................................................................................................................... 6
1.4 Selection and qualifications of personnel .................................................................................. 7
1.5 Servicing and maintenance.......................................................................................................... 8
1.6 Danger caused by electrical power............................................................................................. 8
2 First Start-Up with the Customer.......................................................................................................... 9
2.1 Mechanical check........................................................................................................................... 9
2.2 Electrical check and assembly of the control system ............................................................ 11
2.2.1 Connecting the control system to the touch panel and printer...................................... 12
2.3 Starting up the measuring bed.................................................................................................... 13
2.3.1 Start screen ........................................................................................................................... 13
2.3.2 Starting the initialisation cycle ............................................................................................ 14
2.3.3 Changing to system mode .................................................................................................. 17
2.3.4 System mode options menu ............................................................................................... 18
2.3.5 System parameters .............................................................................................................. 18
2.3.6 Offset parameters................................................................................................................. 19
2.3.7 Checking the pairs of slats in step 9 (neutral position) .................................................. 19
2.3.8 Initialising the sensors.......................................................................................................... 20
3 Measurement Procedure..................................................................................................................... 21
4 Faults...................................................................................................................................................... 25
4.1 Communication fault from touch panel à control system ...................................................... 25
4.2 Communication fault from control system à measuring bed ................................................ 26
4.3 Fault: one pair of slats only goes in one direction, one time ................................................ 27
4.4 Fault: one pair of slats is not moving........................................................................................ 27
5 Caring for Your Measuring Bed.......................................................................................................... 28
6 Index....................................................................................................................................................... 29
Page 6
150828_BA STREAM-motion_DE_V15-1_2015­08-28.doc
Page 5
1 Safety Instructions
Danger
Warning
Attention
Please note
Important
1.1 Representation of warning signs and symbols
In this user manual, safety instructions are highlighted using special markers:
This means that death, severe injuries or significant damage to property will result if the respective precautionary measures are not taken.
This means that death, severe injuries or significant damage to property may result if the respective precautionary measures are not taken.
This means that minor injuries or damage to property may resultif the respective precautionary measures are not taken.
This means that the equipment, the control system or other objects may be damaged if the respective notices are not heeded.
This highlights important information concerning the handling of the control system or the respective section of the user manual.
Page 7
Page 6
150828_BA
STREAM-motion_DE_V15-1_2015-
08-28.doc
1.2 Basic safety instructions
The control system was developed and manufactured as per the 2006/42/EG machinery directive and the 2006/95/EG low voltage directive.
Here the following harmonised standards were applied:
- EN 60204-1:2006
- EN 60439-1+A1:2004
- EN ISO 13849-1
- EN 12100:2010 In normal cases, intended usage and proper maintenance of the
control system will not present any dangers to property or people’s health. However, improper installation, maintenance and operation of the whole system or machine, failure to follow the instructions in this user manual, or the involvement of insufficiently qualified personnel, may result in connected actuators such as motors presenting a danger.
1.3 Intended usage
The control system and the equipment have been built using state-of­the-art technology in accordance with approved safety regulations. However, their usage may present a danger to the life and/or health of the user or third parties, or cause damage to machines, equipment or other material property.
The control system and the equipment may only be used as intended, in a technically impeccable condition, with an awareness of the associated dangers, and with due regard to safe usage as per the user manual. The proper and safe operation of the control system requires appropriate transportation, proper storage and assembly as well as careful servicing and maintenance. Any faults which may impair safety must be immediately resolved.
The control panel and the equipment are exclusively designed for the ergonomic measurement of the human body in a lying position. Any usage which deviates from this purpose does not qualify as intended usage.
For intended usage of the control system, the instructions on mechanical and electrical layout, start-up, operation, and troubleshooting described in this user manual must be followed.
Page 8
150828_BA STREAM-motion_DE_V15-1_2015­08-28.doc
Page 7
1.4 Selection and qualifications of personnel
Warning
Warning
Any works carried out on the control system as regards parametrisation, installation, start-up, operation and maintenance may only be done by trained personnel (e.g. qualified electricians, electrical engineers).
Personnel working on start-up and maintenance must be familiar with the safety concepts of the automation technology.
Operating personnel must be instructed in the use of the control system and know the operating instructions.
The installation, start-up and maintenance personnel must hold a qualification which entitles them to operate the control system.
Safety equipment must not be manipulated or removed! Failure to observe this could result in damage to property or risk to personal health!
Page 9
Page 8
150828_BA
STREAM-motion_DE_V15-1_2015-
08-28.doc
1.5 Servicing and maintenance
Warning
Warning
Warning
If measurement or test works are required at the live supply voltage, the specifications and practice directives of the applicable legal and country-specific accident prevention regulations must be observed. Suitable power tools should be used.
Repairs to control system components may only be carried out by trained personnel. Unauthorised opening of the control cabinet and improper interference or repairs may result in personal injuries or damage to property. Components may only be replaced like-for-like.
When replacing fuses, only types specified in the technical data may be used.
When replacing batteries, only types specified in the technical data may be used. Batteries may only be disposed of as hazardous waste, without exception.
Defective parts may only be replaced with parts which come from the same manufacturer as the defective part and which have been declared by said manufacturer as equivalent in terms of safety and performance. Should this not be observed, the person who made
the change to the equipment will take on the status of equipment manufacturer.
1.6 Danger caused by electrical power
After opening the switchboard and removing the covering or housing of system components, certain parts of the control system can be accessed which may be at a dangerous voltage.
Before maintenance or repair works can be started, the power cable must be plugged out!
The operator must ensure that unauthorised and improper interference is prevented (e.g. by locking the switchboard).
The personnel must be familiar with all sources of danger and procedures for start-up, maintenance and operation as per the information in the user manual.
Page 10
150828_BA STREAM-motion_DE_V15-1_2015­08-28.doc
Page 9
2 First Start-Up with the Customer
Important
2.1 Mechanical check
Step 1: Unpack the measuring bed, check for any mechanical damages or damage caused
during transportation.
Step 2: Check the following points:
Gently push down on the lower longitudinal profile. The profile should not budge.
Visually inspect the vertical and horizontal profiles – they must be in close-fitting contact with each other. Check the screws as well.
Check to see that all 11 sensor plates are firmly fitted.
Page 11
Page 10
150828_BA
STREAM-motion_DE_V15-1_2015-
08-28.doc
Check to see that all 11 limit switch plates are firmly fitted (brass casing and plate).
Check all 11 actuators to see if the lower and the upper cogwheels interlock cleanly and free from backlash.
Corrections can be made by shifting the axis of the cogwheel console.
During subsequent use the actuators will need to be able to be moved both smoothly and silently.
Page 12
150828_BA STREAM-motion_DE_V15-1_2015­08-28.doc
Page 11
2.2 Electrical check and assembly of the control system
Important
The control system comprises the following components:
Touch panel Control box Control box to
measuring bed connector cable
The serial numbers on
- the touch panel
- the printer
- the control box (no picture)
- and the measuring bed (no picture)
Touch panel power supply unit Printer
Power cable for printer USB cable for printer Ethernet patch cable Power cable
control box
must correspond!
All components have been labelled with IP numbers and cannot be swapped or individually replaced.
The following ports and switches can be found on thetouch panel:
ATX/AT
Power supply
Ethernet port Ports marked with in the image are not
used.
Auto start or manual start selector switch
The switch should always be set to AT.
On / Off switch
2 x USB ports
Page 13
Page 12
150828_BA
STREAM-motion_DE_V15-1_2015-
08-28.doc
The following ports can be found on the control box and on the measuring bed:
Power supply 230 VAC / 50 Hz Electrical socket 220 V (depending on requirements, e.g. for the touch panel power supply unit)
Ethernet port (connection to
touch panel)
Multipole socket for connecting
control box to measuring bed
2.2.1 Connecting the control system to the touch panel and printer
Connect the elements of the control system as per the following image:
Plug in the touch panel power adapter
Plug the Ethernet cable into the control box and the touch panel
Control box power cable for power supply (final step)
Connect control box to measuring bed
The whole system should ideally be run via a switchable electrical socket so that all components can be switched on/off simultaneously.
Plug the USB cable into the touch panel and the printer
Connect printer power supply cable to an external electrical socket and to the printer
Page 14
150828_BA STREAM-motion_DE_V15-1_2015­08-28.doc
Page 13
2.3 Starting up the measuring bed
Warning
Please note
The control system must only be connected to the power supply and started up if the measuring bed’s mechanical system has been mounted in the specially-designed bed frame and the mattress has been placed on the slat frame. (Finger-safe assembly – no moving mechanical parts exposed). Exposed moving parts, e.g. cogwheels,
screw drives or chain drives may present a risk of injury!
Important: the measuring bed’s pairs of slats automatically move upwards after the touch panel has been switched on.
For start-up please proceed as follows:
Plug a mouse into the free USB port on the touch panel.Plug the control system and the printer into a power socket (230 VAC 50 Hz).The touch panel will start automatically.The measuring bed will automatically move to the neutral position = step 9 (highest setting)The following start screen will be displayed on the panel:
2.3.1 Start screen
Start screen
After booting up, the pictured start screen will appear.
Page 15
Page 14
150828_BA
STREAM-motion_DE_V15-1_2015-
08-28.doc
2.3.2 Starting the initialisation cycle
1. Press “Run measurement” on the start screen
2. “First measurement” will appear on the screen
Press “Continue”
The pairs of slats will move down and the control system will perform an internal measurement cycle. During this procedure, “Running setup” will appear on the screen.
3. “Return to neutral position” will appear on the screen
Press “Continue”
The pairs of slats will return to the neutral position (step 9). During this procedure, you will see “Moving to neutral position” on the screen.
Run measurement
Continue
First measurement
Continue
Return to neutral
After it has been turned on, the control system requires an initialisation cycle.This is always done while “empty”, i.e. free of any loads and without a person on the measuring bed. Start the initialisation cycle as follows:
Page 16
150828_BA STREAM-motion_DE_V15-1_2015­08-28.doc
Page 15
4. “Second measurement” will appear on the screen
Press “Continue”
The pairs of slats will move down and the control system will perform a further internal measurement cycle. During this procedure, “Running setup” will appear on the screen.
5. “Return to neutral position” will appear on the screen
Press “Continue”
The pairs of slats will return to the neutral position (step 9). During this procedure, you will see “Moving to neutral position” on the screen.
6. “Move to calculated values” will appear on the screen
Press “Continue”
The pairs of slats will now move to their calculated starting position. During this procedure, you will see “Setting values” on the screen.
7. The prompt “Setting OK?” will appear on the screen
Press “Continue”
Second measurement
Continue
Return to neutral position
Continue
Move to calculated values
Continue
Setting OK?
Neutral position
Continue
Step
Page 17
Page 16
150828_BA
STREAM-motion_DE_V15-1_2015-
08-28.doc
8. The prompt “Print data?” will appear on the screen
Press “No”
9. The prompt “Exit?” will appear on the screen
Press “Yes”
This closes the initialisation cycle. The measuring bed is now ready for measurements. “First measurement” will appear on the screen. If no measurement is started within 2 minutes, the display will return to the start screen.
By pressing “No” you will return to the “Setting OK?” page
Print data?
No
Yes
Exit?
No
Yes
Exit?
Continue
After exiting program, remove
load from measuring bed before
next measurement!
You can return to the “First measurement” screen at any time using the blue home key in the
top left-hand corner of the screen.
Page 18
150828_BA STREAM-motion_DE_V15-1_2015­08-28.doc
Page 17
Second measurement
2.3.3 Changing to system mode
1. Start a measurement cycle as described in the previous chapter
2. When you get to the “Second measurement” screen, use the mouse to navigate to the “philrouge” logo and then click the left mouse button for 10 seconds
This can only be done with a connected mouse, and not via the touchscreen.
The display will return to the start screen
3. Press “Run measurement”
This will again bring you to the “Second measurement” screen
4. Once again, navigate to the “philrouge” logo with the mouse and click the left mouse button for 10 seconds
The display will now change to the system menu
Continue
Run measurement
Second measurement
Continue
System mode is only intended for specialised start-up personnel for installation works on the measuring bed.
Page 19
Page 18
150828_BA
STREAM-motion_DE_V15-1_2015-
08-28.doc
2.3.4 System mode options menu
Offset
System
Back
Pressing the “Exit” key will close the program and bring you to the Windows desktop.
Pressing the “Offset” key will bring you to the offset parameters page.
Pressing the “System” key will bring you to the system parameters page.
Pressing the “Back” key will bring you back to the “Second measurement” page.
2.3.5 System parameters
The system parameters menu allows the motors to be moved individually or collectively in manual mode. Here the motor positions can be checked against the final values of the sensors, and the sensor values can be initialised. The motor numbers start on the headboard with 1 (foot section = 11).
Selection of rotational direction of motors (up/down)
Selection of motors 1 to 11
Reserve, currently no function
Move all motors collectively
Move all motors to basic position
Press button for 10 sec to initialise the distance sensors to their base value
Sensor values (always 1150 in the basic top position)
Exit system parameters
Page 20
150828_BA STREAM-motion_DE_V15-1_2015­08-28.doc
Page 19
2.3.6 Offset parameters
Offset input for detected setting
Offset in steps + or -
Current status
In the offset parameters menu, offset values can be entered (in steps) for the pairs of slats. The numbers of the pairs of slats start on the headboard with 1 (foot section = 11).
Chosen offset Increase offset Reduce offset
Exit offset parameters
2.3.7 Checking the pairs of slats in step 9 (neutral position)
In step 9, 5 locking positions should be visible above the clip plate, both left and right
Otherwise the heights can be manually set by adjusting the spindles
Setting the limit switch, see point 4.4
Page 21
Page 20
150828_BA
STREAM-motion_DE_V15-1_2015-
08-28.doc
2.3.8 Initialising the sensors
Move pairs of slats to horizontal neutral position. The red distance measurement spot must hit
the middle of the measurement plate. The adhesive tape is important for the correct
functioning of the sensor.
Switch to the “System parameters” image on the touchscreen, see point 2.3.5.
1. Bring all motors to basic position (top) by selecting UP rotational direction and moving the motors using the “Motor position all” key. Keep the key pressed until all pairs of slats have reached their end position.
2. Now press the “Initialise” key for 10 seconds
The distance sensors will now be initialised and the value 1150 will appear for all sensors
3. Press “Close” to exit the menu.
This concludes the start-up. You can now carry out measurements.
Page 22
150828_BA STREAM-motion_DE_V15-1_2015­08-28.doc
Page 21
3 Measurement Procedure
Depending on how long the system has been idle, the touch panel will either display the start screen or the “First measurement” screen (step 2).
1. Press “Run measurement” on the start screen
2. “First measurement” will appear on the screen
Press “Continue”
The pairs of slats will move down and the control system will perform a measurement cycle. During this procedure, “Running setup” will appear on the screen.
Run measurement
Current values
Continue
First measurement
The measuring bed may never be operated without a mattress!
When restarting, the system will initialise itself and will simultaneously move all pairs of slats to the neutral position, i.e. step 9 = highest step.
When the STREAM Motion has reached the neutral position, wait at least 10 seconds before carrying out the first measurement. This also applies to consecutive measurements, see reminder on screen step 9.
The program can be stopped at any time by cutting the power supply.However, you should wait at least 60 seconds before turning the power supply back on again.
Page 23
Page 22
150828_BA
STREAM-motion_DE_V15-1_2015-
08-28.doc
3. “Return to neutral position” will appear
4. “Second measurement” will appear on the screen
Press “Continue”
The pairs of slats will move down and the control system will perform a further measurement cycle. During this procedure, “Running setup” will appear on the screen.
5. “Return to neutral position” will appear on the screen
Press “Continue”
The pairs of slats will return to the neutral position (top). During this procedure, you will see “Moving to neutral position” on the screen.
Return to neutral
Continue
Second measurement
Continue
Return to neutral position
Continue
on the screen
Press “Continue”
The pairs of slats will return to the neutral position (top). During this procedure, you will see “Moving to neutral position” on the screen.
Page 24
150828_BA STREAM-motion_DE_V15-1_2015­08-28.doc
Page 23
6. “Move to calculated values” will appear on the screen
Press “Continue”
The pairs of slats will now move to their calculated lying profile. During this procedure, you will see “Setting values” on the screen.
7. The prompt “Setting OK?” will appear on the screen
Press “Continue”
The lying profile can be customised by manually adjusting the pairs of slats, from 1 (head) to 11 (foot), using the “+” and “–” keys. The 12th pair of slats always moves in tandem with pair 11, which is why it is not displayed on the screen.
Manual control of individual motors in step 7 may only be done incrementally. Before moving to the next step wait until the pair of slats has reached the respective step, otherwise incorrect grid spacing will result.
8. The prompt “Print data?” will appear on the screen
Press “Yes” to get a measurement report
Return to neutral position
Continue
Setting OK?
Continue
Neutral position
Print data?
No
Yes
Important
Page 25
Page 24
150828_BA
STREAM-motion_DE_V15-1_2015-
08-28.doc
9. The prompt “Exit?” will appear
Exit?
YesNoFirst measurement
Continue
After exiting program, remove
load from measuring bed before
next measurement!
on the screen
Press “Yes”
This completes the measurement cycle.“First measurement” will again appear on the screen. If no measurement is started within 2 minutes, the display will return to the start screen.
By pressing “No” you will return to the “Setting OK?” page
You can return to the “First measurement” screen at any time using the blue home key in the
top left-hand corner of the screen.
Page 26
150828_BA STREAM-motion_DE_V15-1_2015­08-28.doc
Page 25
4 Faults
4.1 Communication fault from touch panel à control system
Fault:
After starting the touch panel, a fault message appears.
No communication with control system
Troubleshooting:
Check to see that the Ethernet cable
is properly connected
Check the cable for damageIs the cable plugged into the correct
port?
Is the power supply connected?
Plug out power supply before opening the switchboard
Check to see if main fuse is activeCheck to see if the cable is properly
plugged in inside the control box (to the feed-through and to the CPU)
If you have corrected the source of the fault, reboot the control system and the touch panel.
Page 27
Page 26
150828_BA
STREAM-motion_DE_V15-1_2015-
08-28.doc
4.2 Communication fault from control system à measuring bed
First measurement
Fault:
After start-up, the “Continue” button is missing
Troubleshooting:
Check the connecting cable between the control box and the measuring bed
Is the cable plugged in and fastened?
Check cable for damage
Connection to measuring bed
Page 28
150828_BA STREAM-motion_DE_V15-1_2015­08-28.doc
Page 27
4.3 Fault: one pair of slats only goes in one direction, one time
Danger
Danger
Fault:
Limit switch defect or wire disconnected
Troubleshooting:
Unplug the power plug from the control box. Check the wiring and replace the limit switch if
necessary
4.4 Fault: one pair of slats is not moving
Fault:
Faulty fuse (indicated via a red LED on the fuse’s disconnect terminal in the control box)
Troubleshooting:
Plug out the control box power plug Replace the faulty fuse (2x spare 5 x 20 mm
4AT
microfuses
switchboard) Replace fuse
-
Swivel the fuse’s disconnect terminal upwards
-Open the fuse compartment at the side
-Replace the fuse
Resolve the cause of the faulty fuse (actuator is blocked or stiff)
can be found in the
Page 29
Page 28
150828_BA
STREAM-motion_DE_V15-1_2015-
08-28.doc
5 Caring for Your Measuring Bed
Check the functions of the measuring bed
(as per point 2) every 3–6 months.
Clean the sensors with a soft, dry,
dust-free cloth
Apply commercially-available
machinery lubricant to the lifting
spindles Visual check The limit switch’s cogwheels and threaded
spindles do not require any lubrication.
Page 30
150828_BA STREAM-motion_DE_V15-1_2015­08-28.doc
Page 29
6 Index
Ports, sockets & connections ....................................11, 12
Intended usage ................................................................6
Electrical check .............................................................11
First start-up....................................................................9
Dangers...........................................................................8
Motors – manual mode.................................................18
Start-up.........................................................................13
Contents.........................................................................4
Initialising the sensors.................................................. 20
Initialisation cycle ........................................................14
Maintenance...................................................................8
Checking the slats........................................................19
Machine guidelines........................................................ 6
Mechanical check ..........................................................9
Measurement procedure...............................................21
Moving the motors.......................................................18
Offset parameters .........................................................19
Parameters..................................................................... 19
Selection and qualifications of personnel ..................... 7
Care............................................................................... 28
Safety instructions .......................................................... 5
Start screen ................................................................... 13
Limit switch fault.......................................................... 27
Communication fault from control system
measuring bed …………………………………....... 26
Communication fault from touch panel
control system........................................................... 25
Fuse fault ...................................................................... 27
Faults............................................................................. 25
System mode ................................................................. 17
System mode options menu............................................ 18
System parameters........................................................ 18
Accident prevention regulation....................................... 8
Warnings......................................................................... 5
Maintenance.................................................................... 8
Control system assembly............................................... 11
Loading...