The ST100 UNIVERSAL Controller provides low cost control over a wide range of RS422 VTR
and DDR formats and brands in your facility.
Simple and easy to use.
No complicated menus to search through.
All the functions you need at the press of a button. Eliminates the need for multiple remote
controllers and the associated clutter of several pieces of control hardware.
a. FEATURES
Timecode/tape time display; Jog/Shuttle Wheel.
12-function keypad provides the functions you need at the press of a button.
Small footprint desktop unit, 8 ½” x 5 ½”.
Can be easily customized for your specific needs. Customize the ST100 with the
transport control functions and status indicators you require for your specific
applications.
Can be used through your facility’s existing RS422 Control router, RS422 patch bay or
9-pin switch box.
b. TIME CODE DISPLAY
Display Timecode or CTL Tape Timer per the mode selector switch on the front panel of
the VTR. The Time Mode can be selected manually by pressing the [SHIFT] + [JOG]
keys, each press will step to the next Time Mode: CTL Tape Time, Timecode, VITC.
c. STANDARD FUNCTIONS
RECORD
PLAY
STOP
REWIND
FAST FORWARD
JOG/SHUTTLE MODE SELECT
NOTE: JOG & SHUTTLE WHEEL - Active ONLY from STOP/STILL or
JOG/SHUTTLE modes.
d. REAL-TIME STATUS INDICATORS: ACTIVE ON
RECORD
PLAY
STOP/STILL
REWIND/REVERSE
FAST FORWARD/FORWARD
JOG MODE SELECTED
ST100 VTR Controller
33
3. INSTALLATION
a. Plug one end of a 9-conductor, RS422 serial cable into the 9-pin connector on the rear of
the ST100. Plug the other end of the cable into the 9-pin remote connector on the VTR.
b. Plug the 9-pin D-female connector on the POWER SUPPLY into the male 9-pin
connector on the rear of the ST100.
Plug the AC connector into a wall outlet, 90 VAC - 265 VAC, 50-60 Hz.
c. Select REMOTE operation on the VTR's front panel.
d. Set the RECORD SELECTOR SWITCHES, located on the rear panel of the ST100, to
the desired record mode per the “RECORD SELECTOR CHART.”
Installation is completed.
NOTE: For AMPEX 1-inch and D2 VTRs, set VTR ID to 0001.
Connection Diagram
NOTE: Rack mount version shown with Optional User Supplied external GPI switch inputs and tally
outputs. Tabletop version uses the same connections.
ST100 VTR Controller
44
4. OPERATION
Select the desired transport function by pressing the appropriate switch on the front of the ST100.
The Real-Time Status Indicators will light to indicate the VTRs current tape transport mode.
For example: Pressing [PLAY] will put the VTR into the PLAY mode.
The PLAY Status Indicator will light when the VTR is in PLAY mode.
Loss of serial communication with the VTR is indicated by ALL status LEDs turning ON.
Selecting LOCAL control on the VTR's front panel will turn OFF all status LEDs.
a. RECORD MODE
Four (4) record modes are available:
Crash Record (Full Record), Assemble Record, Insert Record and Record Lockout.
Press only the [RECORD] switch to activate the selected Record mode.
The Record Status Indicator will light when the VTR is in RECORD mode.
NOTE: The VTR will not go into Record mode if “Record Inhibit” is enabled on the
VTR or tape cassette.
b. RECORD SELECTOR SWITCHES
S1 S2 S3 S4 S5 S6
Mode
Record Lockout OFF OFF OFF OFF OFF OFF
Assemble Record ON OFF OFF OFF OFF OFF
Crash Record OFF ON OFF OFF OFF OFF
Insert Record ON VID AUD1 AUD2 AUD3 AUD4 Active On
NOTE: AUD3 & AUD4 should be ON ONLY
audio, i.e.: D1-, D2- and D3-type VTRs.
c. TIME CODE DISPLAY
Display Timecode or CTL Tape Timer per the mode selector switch on the front panel of
the VTR. The Time Mode can be selected manually by pressing the [SHIFT] + [JOG]
keys, each press will step to the next Time Mode: CTL Tape Time, Timecode, VITC.
for VTRs that support 4 channels of
ST100 VTR Controller
55
5. ST100-SXD FUNCTIONS
The ST100-SXD is designed to work specifically with the Sony XDCAM. The ST100-SXD
includes support for clip access commands.
a. GO TO FIRST CLIP
Press [SHIFT] + [PLAY] to go to the beginning of the first clip.
b. GO TO LAST CLIP
Press [SHIFT] + [STOP] to go to the end of the last clip.
c. GO TO PREVIOUS CLIP
Press [SHIFT] + [REWIND] to go to the beginning of the previous clip.
d. GO TO NEXT CLIP
Press [SHIFT] + [FFWD] to go to the beginning of the next clip.
ST100 VTR Controller
66
Reference . . .
6. SPECIFICATIONS
FRONT PANEL
6 Status LEDs Record, Play, Stop, Rewind, FFwd, Jog
1 Power LED
3 Direction LEDs Indicates direction of Jog Shuttle
Switches Record, Play, Stop, Rewind, Fast Forward, Jog, Shift, Reset
DIP Switches RECORD MODE: Lockout, Crash, Insert, Assemble
Display 2-Line LCD, back-lit with adjustable contrast
Jog/Shuttle Wheel
Size 19” x 5” x 1-3/4” (Rack mount)
7” x 5” x 1-1/2” (Tabletop)
Weight 2 lbs.
REAR PANEL CONNECTORS
RS422 Serial Out 9-pin D-type connector, female (DB9-F)
Power: 5 volt D.C., 500 ma. 90-265 VAC,
50/60 Hz converter supplied (Rack mount or tabletop)
15-Pin D-Type, Female (DB15-F)
Version 6.x Software (Rev. 4.x Hardware) ONLY
Pin # Function Note _
1 +5VDC Power for Status External Indicators
2 Switch #7, Shift Mode Select Active Low (+5 Pull Up)
3 Led #1 drive, Record Status Indicator Active Low, Open Collector Output
4 Led #2 drive, Play Status Indicator “ “ “
5 Led #3 drive, Stop Status Indicator “ “ “
6 Led #4 drive, Rewind Status Indicator “ “ “
7 Led #5 drive, Fast Forward Status Indicator “ “ “
8 Led #6 drive, Jog Mode Indi cator “ “ “
9 Command Common
10 Switch #1, Record Command Active Low (+5 Pull Up)
11 Switch #2, Play Command Active Low (+5 Pull Up)
12 Switch #3, Stop Command Active Low (+5 Pull Up)
13 Switch #4, Rewind Command Active Low (+5 Pull Up)
14 Switch #5, Fast Forward Command Active Low (+5 Pull Up)
15 Switch #6, Jog Mode Select Activ e Low (+5 Pull Up)
ST100 VTR Controller
88
GPI CONNECTOR – Version 7.x Software
26-Pin D-Type, Female (DB26F)
Version 7.x software (Rev. 5.x Hardware) ONLY
Pin # 1 GPI 1 Out, Record tally Pin # 14 GPI 5 In, Fast Forward Command
2 GPI 2 Out, Play tally 15 GPI 6 In, Standby ON Command
3 GPI 3 Out, Stop tally 16 GPI 7 In, Pause Command
4 GPI 4 Out, Rewind tally 17 GPI 8 In, None
5 GPI 5 Out, Fast Forward Command 18 Common Ground
6 GPI 6 Out, Standby 19 + 5 VDC
7 GPI 7 Out, Pause 20 + 5 VDC
8 GPI 8 Out, None 21 No Connection
9 Common Ground 22 No Connection
10 GPI 1 In, Record command 23 No Connection
11 GPI 2 In, Play command 24 No Connection
12 GPI 3 In, Stop Command 25 No Connection
13 GPI 4 In, Rewind Command 26 No Connection
POWERSUPPLYCONNECTOR
9-Pin D-Type, Male (DB9M)
Pin # 1 +5Vdc Pin # 6 +5Vdc
2 +5Vdc 7 Ground
3 Ground 8 Ground
4 No connection 9 Ground
5 No connection
ST100 VTR Controller
99
7. TABLE TOP REAR AND TOP VIEW
Table Top Rear View
Table Top Top View
ST100 VTR Controller
1100
RACKMOUNT FRONT AND REAR
VIEW
ST100 VTR Controller
1111
8. DNF CONTROLS LIMITED WARRANTY
DNF Controls warrants its product to be free from defects in material and workmanship for a period of one
(1) year from the date of sale to the original purchaser from DNF Controls.
In order to enforce the rights under this warranty, the customer must first contact DNF’s Customer Support
Department to afford the opportunity of identifying and fixing the pr oblem without sending the unit in for
repair. If DNF’s Customer Support Department cannot fix the problem, the customer will be issued a
Returned Merchandise Authorization number (RMA). The customer will then ship the defective product
prepaid to DNF Controls with the RMA number clearly indicated on the customer’s shipping document.
The merchandise is to be shipped to:
DNF Controls
12843 Foothill Blvd., Suite C
Sylmar, CA 91342
USA
Failure to obtain a proper RMA number prior to returning the product may result in the return not being
accepted, or in a charge for the required repair.
DNF Controls, at its option, will repair or replace the defective unit. DNF Controls will return the unit
prepaid to the customer. The method of shipment is at the discretion of DNF Controls, principally UPS
Ground for shipments within the United States of America. Shipments to international customers will be
sent via air. Should a customer require the product to be returned in a more expeditious manner, the return
shipment will be billed to their freight account.
This warranty will be considered null and void if accident, misuse, abuse, improper line voltage, fire, water,
lightning or other acts of God damaged the product. All repair parts are to be supplied by DNF Controls,
either directly or through its authorized dealer network. Similarly, any repair work not performed by either
DNF Controls or its authorized dealer may void the warranty.
After the warranty period has expired, DNF Controls offers repair services at prices listed in the DNF
Controls Price List. DNF Controls reserves the right to refuse repair of any unit outside the warranty
period that is deemed non-repairable.
DNF Controls shall not be liable for direct, indirect, incidental, consequential or other types of damage
resulting from the use of the product.
# # #
ST100 VTR Controller