DNF Controls RPC-HOR-PESA User Manual

Page 1
12843 Foothill Blvd.,
Suite D
818 898 3380 voice
818 898 3360 fax
www.dnfcontrols.com
Model No. RPC-HOR-PESA
Horizon Protocol
To
PESA
1 RPC-HOR-PESA
USER MANUAL
Page 2
Table of Contents
1. REVISION HISTORY 3
2. DESCRIPTION 4
DEFINITIONS 4
3. INSTALLATION 5
4. MASTER ROUTER - PESA 6
SETTING NUMBER OF LEVELS 6
5. MASTER ROUTER - PESA MAPPING LEVELS 6
6. RPC STATUS DISPLAY 6
7. TEST COMMUNICATION BETWEEN MASTER ROUTER AND RPC 7
8. TEST COMMUNICATION BETWEEN PESA AND RPC 7
9. SPECIFICATIONS 8
FRONT PANEL 8 REAR PANEL 8 POWER SUPPLY CONNECTOR 8 MASTER ROUTER RS422 SERIAL CONNECTOR 8 SLAVE ROUTER RS232 SERIAL CONNECTOR 9 HORIZON (MASTER ROUTER) TO RPC WIRING INTERFACE 9 RPC TO PESA WIRING INTERFACE 9
10. DNF CONTROLS LIMITED WARRANTY 10
Manual Version ..........................................................2.4 120403
Document ID:...............……RPC-HOR-PESA_User_Manual.doc
2 RPC-HOR-PESA
Page 3
1. REVISION HISTORY
Rev. 2.3 063003 Reformatted.
Corrected Section 3. INSTALLATION.
Rev. 2.4 120403 Company header information revised.
Added DNF Controls Limited Warranty.
3 RPC-HOR-PESA
Page 4
2. DESCRIPTION
Maintain control of your routers with DNF’s Router Protocol Converter (RPC) - the missing link for control integration of routers from different manufacturers. The RPC lets routers from different manufacturers communicate with each other. Instead of using a different control system for each router in your facility, consolidate control under your main router. The other routers “look like” levels on your main system.
Allows any router that “speaks” Horizon protocol to control the PESA Routers.
The PESA looks like one or more levels on the Master Router.
Fast and Easy to set up and use.
Map PESA router levels to desired levels on the Master Router.
DEFINITIONS
Words surrounded by brackets, for example, [ENTER], are keys on the RPC. [XXX] + [XXX] means hold the two keys down simultaneously. XXX = Key name.
The Horizon inputs and outputs start numbering at “0.” The PESA inputs and outputs start numbering at “1.” Horizon Levels are 0, 1, 2 and 3.
4 RPC-HOR-PESA
Page 5
3. INSTALLATION
a. Connect the MASTER ROUTER RS232 connector on the back of the RPC to the
connector on the Master Router (router that “speaks” Horizon protocol).
Communication format: 38400, Even, 8, 1.
b. Connect the SLAVE ROUTER RS232 connector on the back of the RPC to the connector
on the PESA Router labeled •COM 1• (see wiring information below). Communication format: 9600, N, 8, 1. Use a Null Modem Cable. Refer to wiring information at the end of the Manual.
c. Connect power.
Installation is complete.
Connection Diagram
5 RPC-HOR-PESA
Page 6
4. MASTER ROUTER - PESA
SETTING NUMBER OF LEVELS
a. Press [SHIFT] + [LEVEL] on the RPC.
b. The display shows “Set No. Of Levels.”
c. Press [ENTER] to enter the number of PESA Levels.
d. The Display shows the number of levels on the PESA Router.
e. Use [Î] or [Í] to select the number of levels corresponding to the PESA Router’s
configuration.
f. Press [ENTER] at anytime to exit.
5. MASTER ROUTER - PESA MAPPING LEVELS
1. Press [SHIFT] + [LEVEL] on the RPC.
2. Press [Î] or [Í].
The display shows “Map PESA Levels.”
Press [ENTER].
3. The display shows “PESA=xx, HOR=yy,” where: xx - level on the PESA router, yy - corresponding to the level on the Master Router.
4. Press [Í] to scroll through all the existing PESA levels and view Master Router
levels associated with them.
5. Press [Î] to change Master Router level for the selected PESA level or turn it off.
6. Press [ESC] twice when done.
Setup is complete. Now the PESA router behaves as a matrix of the Master Router.
6. RPC STATUS DISPLAY
The RPC Display shows the communication status.
If the communications with the Master Router is established, then the first line of the display shows “Master: OK.”
Otherwise, it shows “Master: Error.”
The second line of the display shows “PESA=OK” if communication with PESA is successful. Otherwise, it shows “PESA: ERR.”
6 RPC-HOR-PESA
Page 7
7. TEST COMMUNICATION BETWEEN MASTER ROUTER AND RPC
a. Press [SHIFT] + [MENU].
b. Press [Î] or [Í] until the display says “MASTER TEST.”
c. Press [ENTER].
d. The first line of the display says “MASTER DATA.”
e. The second line of the display shows data received from the Master Router. The data
is represented as standard ASCII characters.
f. Press [ESC] to exit test mode.
8. TEST COMMUNICATION BETWEEN PESA AND RPC
a. Press [SHIFT] + [MENU].
b. Press [Î] or [Í] until the display says “PESA TEST.”
c. Press [ENTER].
d. The first line of the display says “PESA TEST.”
e. If communication is established between the RPC and the SVS, the second line of the
display shows version information for the Sierra Video Router. If there is an error, the display says “Comm. Error.”
f. Press [ESC] to exit test mode.
7 RPC-HOR-PESA
Page 8
9
. SPECIFICATIONS
FRONT PANEL
1 LED POWER 6 switches Enter, Level, Menu, <, >, Shift/ESC Reset Switch Recessed momentary switch Display 2-Line LCD, back-lit with adjustable contrast
REAR PANEL
Connectors: Master Router, Slave Router (DB9F)
POWER (DB9M)
Size: 19” x 5” x 1-3/4” (Rackmount)
Weight: 7 lbs.
Power: 5 volt D.C., 1500 ma. 90-265 VAC
50/60 Hz converter supplied
POWER SUPPLY CONNECTOR
9-Pin D-Type, Male (DB9M)
Pin# 1 +5Vdc Pin# 6 +5Vdc
2 +5Vdc 7 Ground 3 Ground 8 Ground 4 nc 9 Ground 5nc
MASTER ROUTER RS422 SERIAL CONNECTOR
(Device configuration) 9-Pin D-Type, Female (DB9F)
Pin # 1 Frame Ground Pin# 6 Common
2Transmit A Î 7Transmit B Î 3 Receive B Í 8 Receive A Í 4 Common 9 Frame Ground 5Spare
8 RPC-HOR-PESA
Page 9
SLAVE ROUTER RS232 SERIAL CONNECTOR
(Controller Configuration) 9-Pin D-Type, Female (DB9F)
Pin# 1 Not Used Pin# 6 Not Used
2 Receive 7 Ready to Send 3 Transmit 8 Clear to Send 4Not Used 9Not Used 5 Signal Ground Common
HORIZON (MASTER ROUTER) TO RPC WIRING INTERFACE
Master Router (RS422 Controller) RPC (RS422 Device)
Pin#
1 Frame Ground 2 Receive A Í 2Transmit A Î 3Transmit B Î 3 Receive B Í 4 Common 4 Common 5Spare 5Spare 6 Common 6 Common 7 Receive B Í 7Transmit B Î 8Transmit A Î 8 Receive A Í 9 Frame Ground 9 Frame Ground
Pin#
1 Frame Ground
RPC TO PESA WIRING INTERFACE
RPC (RS232 Controller) PESA (RS232 Device)
Pin#
1Not Used 2 Receive 3 Transmit 3 Transmit 2 Receive 4Not Used 4Not Used 5 Frame Ground 5 Frame Ground 6Not Used 6Not Used 7RTS 7RTS 8CTS 8CTS 9Not Used 9Not Used
Pin#
1Not Used
9 RPC-HOR-PESA
Page 10
10. DNF CONTROLS LIMITED WARRANTY
DNF Controls warrants its product to be free from defects in material and workmanship for a period of one (1) year from the date of sale to the original purchaser from DNF Controls.
In order to enforce the rights under this warranty, the customer must first contact DNF’s Customer Support Department to afford the opportunity of identifying and fixing the problem without sending the unit in for repair. If DNF’s Customer Support Department cannot fix the problem, the customer will be issued a Returned Merchandise Authorization number (RMA). The customer will then ship the defective product prepaid to DNF Controls with the RMA number clearly indicated on the customer’s shipping document. The merchandise is to be shipped to:
DNF Controls 12843 Foothill Blvd., Suite D Sylmar, CA 91342 USA
Failure to obtain a proper RMA number prior to returning the product may result in the return not being accepted, or in a charge for the required repair.
DNF Controls, at its option, will repair or replace the defective unit. DNF Controls will return the unit prepaid to the customer. The method of shipment is at the discretion of DNF Controls, principally UPS Ground for shipments within the United States of America. Shipments to international customers will be sent via air. Should a customer require the product to be returned in a more expeditious manner, the return shipment will be billed to their freight account.
This warranty will be considered null and void if accident, misuse, abuse, improper line voltage, fire, water, lightning or other acts of God damaged the product. All repair parts are to be supplied by DNF Controls, either directly or through its authorized dealer network. Similarly, any repair work not performed by either DNF Controls or its authorized dealer may void the warranty.
After the warranty period has expired, DNF Controls offers repair services at prices listed in the DNF Controls Price List. DNF Controls reserves the right to refuse repair of any unit outside the warranty period that is deemed non-repairable.
DNF Controls shall not be liable for direct, indirect, incidental, consequential or other types of damage resulting from the use of the product.
# # #