Description
The XR5 fire system has been designed with your safety in mind using the latest in computer technology. The system combines ease of use with a simple to understand LCD (Liquid Crystal Display) keypad to offer the full range of features demanded by today’s fire professionals.
About the keypad
Power
LED
SELECT keys
Data Entry
keys
POWER
ABC PRINTING
SYSTEM NORMAL
234
1
AABBCC DDEEFF GGHHII JJ KK LL
5678
90
YYZZ
COMMAND
VVWWXXMMNNOO PPQQRR SS TTUU
LCD Keypad
The SELECT keys
These keys allow you to choose an option by pressing the SELECT key under the choices shown in the display.
Lighted display
The keypad uses a backlit display and plain English text to show events occurring on your system.
Data Entry keys
These keys allow you to enter the code number when using the system.
The ARROW key
The ARROW key allows you to back up through the list of functions in the User Menu, or make corrections when entering information.
The COMMAND key
The COMMAND key allows you to advance through the options on the keypad display, and enter information into the system.
Power LED
This remains on steady as long as your fire system is connected to its AC power supply. Should there be an interruption, the green LED will turn off. The system's backup battery maintains normal operation for a time allowing you to contact our service department. Should the battery power become low, the Power LED flashes.
Lighted Display
ARROW key
COMMAND
key
Special Fire Command Messages
SYSTEM NORMAL
This display indicates that fire protection devices, phone lines to the panel, and the panel itself, are in good condition.
ALARM
A fire, supervisory, or auxiliary zone has been tripped. Your system may sound the fire bells, strobes, and any other response programmed into the system.
ALARM SILENCED
A user has silenced the fire bells by entering the code or by using the Alarm Silence function in the User Menu. Even though the bells are silenced, the system is still in a state of alarm and, depending on the keypad model, the keypad keys will glow red or a red LED on your keypad will flash until a System Reset is performed (see page 2).
BYPASS
A zone has been disabled by the system due to repeated trips. If the zone remains normal for one hour it can be restored into the system.
ENTER CODE
The system requires you to enter the user code. As you enter the code, the display shows an asterisk (*) in place of each digit pressed.
TRY AGAIN
The user code you've entered is not recognized by the system. Check the code and try again.
INVALID CODE
You receive this message if you enter an incorrect user code a second time, after receiving the Try Again message.
PH LINE 1 TRBL
There is a problem with the phone line connected to your system. Call for service as soon as possible.
TROUBLE
There is a problem with a protection device or system component. This display is accompanied by a description of the problem.
SERVICE REQUIRED or SYSTEM TROUBLE
There is a problem on the system. Call for service.
Special Fire Command Tones
Your keypad also contains a small speaker that alerts you to events as they occur on your system. Below are brief descriptions of the different tones you'll hear from the keypad:
Key press tone: A short beep when you press a key on the keypad. Trouble tone: A steady tone indicating a trouble condition on
your system. Press a top row key and then enter the user code to silence the trouble tone.
Fire Alarm Tone: Your LC D keypad, your keypad sounds a siren-like tone in one second intervals. This is in addition to other bells or sirens you may have on your system.
LT-0296 (1/01)
Understanding Fire System Terms
Zone
A zone refers to a group of one or more protection devices. For example, smoke detectors on the east side of the premises can be grouped together under the zone name
EAST SMOKES.
Central Station Monitoring
Your system can also be programmed to send alarm and trouble reports to a central station where operators can dispatch the appropriate authorities.
Status List
Status is a feature that automatically displays the status of your system on the keypads. The Status List displays alarm or trouble conditions on zones and trouble conditions that occur with AC or battery power or the phone lines. If more than one alarm or trouble condition occurs at the same time, the keypad sequences this information on its display.
Silencing the Bells During an Alarm
Silencing the keypad trouble sounder
To silence the trouble sounder in the keypad, press any top row SELECT key on the keypad. To silence the keypad sounder when a Supervisory zone is in alarm, you must enter the user code.
Keypad User Menu
Many of the features of your system have been put into a User Menu you can access from the keypad. The menu requires you to enter the user code before you can access any functions.
To access the User Menu:
1. Press the COMMAND key until MENU? NO YES displays.
2. Select YES. The keypad displays ENTER CODE: –. Enter the user code and press the COMMAND key. You can now scroll down through the list of system features.
The functions available in the User Menu are detailed below.
Sensor Reset
Function: Sensor Reset momentarily removes power to smoke detectors allowing them to reset after they have tripped. The detectors must be reset before they can detect any additional alarm conditions.
Make sure all smoke is cleared from around the smoke detectors before performing a Sensor Reset to prevent the alarm from occurring again.
1. Access the User Menu.
2. When SENSOR RESET? displays, press any top row SELECT key. The keypad displays SENSORS OFF for five seconds followed by SENSORS ON.
3. The keypad returns to the status display.
Enter the user code to reset sensors
You can also just enter the user code and press COMMAND to reset the sensors without having to enter the User Menu.
System Test
Function: Tests the battery, alarm bell or siren, and communication to a central station. The System Test function begins automatically as soon as you select it.
1. Access the User Menu. Press the COMMAND key until SYSTEM TEST? displays.
2. Press any SELECT key. The system test begins automatically and the keypad displays:
1) BELL SOUNDING during a two second bell test,
then:
2) BATTERY - OKAY or BATTERY - TRBL to
indicate the condition of the battery, then:
* 3) TRANSMIT TEST and ATTEMPT NO : 1 during the
transmit test, then:
* 4) TRANSMIT OKAY or TRANSMIT FAILED to show
the results of the transmit test, then:
5) TEST END to indicate the System Test is complete.
6) You can cancel the transmit test by pressing the
ARROW key.
* The transmit tests are not applicable for local systems.
Fire Drill
Function: Allows you to practice fire drill evacuations.
1. Access the User Menu. Press COMMAND until FIRE DRILL displays.
2. Press any top row key. The keypad displays SURE? NO YES. Press the SELECT key under YES. The system rings the bells until you enter the user code or until the programmed bell time expires.
User Codes
Function: Allows you to change the user code number you enter at the keypad. NOTE: The user code must always have four digits.
1. Access the User Menu. Press COMMAND until CODE NO: * * * * displays. Press any SELECT key. The keypad displays CODE NO: –.
Enter a new 4-digit user code. If the code you entered is a special service code used internally by the system, the keypad displays ALREADY IN USE. You must enter a different user code.
Display Events
Function: Allows you to review up to 16 past events that occurred on your system in the order of their occurrence.
The system records two event types: Zone Events - Records zone alarms, troubles, restorals, and
service. Supervisory - Records problems with the system’s hardware
components. The system’s memory can hold up to 16 events. After 16
events are in memory,any new event causes the oldest event to be cleared.
1. Access the User Menu.
2. Press COMMAND until DISPLAY EVENTS? appears.
3. Press any SELECT key. The keypad displays the first recorded event. Use COMMAND to scroll down through the event displays.
Use the ARROW key to scroll back up through the event displays. If you press the ARROW key when you first enter Display Events, the keypad returns to the Status List.