Dixon FloTech FT201-12, FloTech FT201, FloTech FT201-18, FloTech FT202, FloTech FT202-12 Maintenance & Operating Instructions

...
5204 ...................... fixed handle, with sight glass
5204C .................... detachable handle, with sight glass
5204NGC .............. detachable handle, no sight glass
5204T .................... fixed handle, with sight glass, Teflon seals, SS spring
5204TC ................. detachable handle, with sight glass, Teflon seals, SS spring
5204NGT .............. fixed handle, no sight glass, Teflon seals, SS spring
5204NGTC ............ detachable handle, no sight glass, Teflon seals, SS spring
5204B .................... fixed handle, sight glass, Bayloy nose ring
5204BC ................. detachable handle, with sight glass, Bayloy nose ring
5204BNG .............. fixed handle, no sight glass, Bayloy nose ring
5204BNGC ........... detachable handle, no sight glass, Bayloy nose ring
5204SNG……fixed handle, no sight glass, stainless steel main spring 5204NGV……fixed handle, no sight glass, Poppet O-ring, for B100
5204NGCV ........... detachable handle, no sight glass, Poppet O-ring, for B100
5204BNGV......... fixed handle, no sight glass, Bayloy nose ring, Poppet O-ring, for B100
5204BNGCV ...... detachable handle, no sight glass, Bayloy nose ring, Poppet O-ring, for B100
5204SNGV fixed handle, no sight glass, stainless steel main spring, Poppet O-ring, for B100
5204P .................... fixed handle, with sight glass, drain plug
Maintenance & Operating Instructions
For
FloTech
Red & Black 2 Wire Retain / Overfill Compatible Optic Sensors
Part Numbers
FT201 FT201-12 FT201-18 FT202 FT202-12 FT202-18 FT206
USA:
Dixon Bayco USA
Chestertown, Maryland Phone: 410-778-2000 Fax: 410-778-4702 Toll Free: 800-355-1991 E-mail: dixonbayco@dixonvalve.com
www.dixonbayco.com
Canada:
Dixon Group Canada Limited
Innisfil (Barrie), Ontario Phone: 705-436-1125 Fax: 705-436-6251 Toll Free: 877-963-4966 E-mail: isales@dixongroupcanada.com
www.dixongroupcanada.com
Mexico:
Dixva, S. de R.L. de C.V.
Monterrey, N.L Phone: 01-800-00-DIXON (34966) Fax: 01-81-8354-8197 E-mail :contactenos@dixonvalve.com.mx
www.dixonvalve.com
Europe:
Dixon Group Europe Ltd
Preston, England Phone: +44 (0)1772 323529 Fax: +44 (0)1772 314664 E-mail: enquiries@dixoneurope.co.uk
www.dixoneurope.co.uk
Asia Pacific:
Dixon (Asia Pacific) Pty Ltd
Wingfield, South Australia Phone: +61 8 8202 6000 Fax: +61 8 8202 6099
E-mail:enquiries@dixonvalve.com.au
www.dixonvalve.com.au
For Sales & Service Contact
10154 Feb 2010
PRODUCT DESCRIPTIONS:
These instructions cover the following FloTech product: FT201 Replacement 2 wire Optic Overfill Probe FT202 2 wire Optic Overfill Sensor with 2”NPT Probe Holder FT206 2 Wire Optic Retain Sensor with ½” NPT Probe Holder
FloTech FT201 and FT202 are mechanically and functionally compatible with Civacon R/M models 1350 and 1050 ROM 2 wire optic sensors. FloTech FT206 sensor is compatible with Civacon ROM models 1000 series. “Civacon” and “ROM” are registered trademarks of
Civacon / Dover Corporation.
INSTALLATION INSTRUCTIONS:
FloTech model FT202 can be mounted in a 2”NPT female pipe coupling or through a 2 3/8”
hole. When mounting in a 2 3/8” hole the gasket and lock nut provided are used to retain the
probe holder in the tank shell or manhole. After the sensor is mounted remove the cap.
Loosen the probe clamp screw and adjust the probe to the correct level point. This is typically 3% of compartment volume. It is not recommended cutting the standard 7” sensor to a shorter length. This will cause insufficient time to stop the flow of product within the load racks reaction time.
IMPORTANT: The actual sensing point adjustment should be determined by the total response time required to prevent a tank overfill condition. The FloTech sensor reaction time is one half second. The loading rack will also have a reaction time. Once the probe is adjusted to the proper height, tighten the clamp screw.