Dixon Electric Test Pump User Manual

Portable
Hydrostatic Electric
Test Pump
Procedure
Dixon
800 High Street • Chestertown, MD 21620
800-355-1991 • Fax: 800-283-4966
dixonvalve.com
Dixon's Portable Electric Hydrostatic Test Pump (E.T.P.)
Features:
Campbell Hausfeld 110 volt Portable Hydrostatic Electric Pump - Model (ETP)
2000 psi maximum test pressure
1.3 gpm ll rate (at 60 psi inlet water pressure)
Quick connect garden hose coupler for water supply line
1/2" x 15 ft. Intermediate hose with brass Straight-Thru Quick Coupler x NPSM swivel connection.
1/2" brass Straight-Thru plug on pressure outlet
0 – 5000 psi bottom mount liquid lled pressure gauge
Test caps, test plugs and pressure relief valves available. Consult the current Dixon Price List (DPL) for part numbers and pricing.
Recommendations
If an extension cord is needed, the following wire sizes must be used:
25' Cord - not less than 14GA wire 50' Cord - not less than 12GA wire 100' Cord - not less than 10GA wire
Electric damage or personal injury can result from using improperly grounded outlets. Only a properly grounded 115 Volt outlet accepting three pronged plug should be used.
Serious damage can result from improper or inadequate electric set up. Fuses, wiring and electrical codes for proper amperage and grounding should be checked.
Make sure that no water / liquid is anywhere that could cause electric shock to the operator (i.e. on the oor or pump where it could come in contact with electric connection).
2Electric Test Pump Dixon 800.355.1991
Safety Precautions
Electric
1. Pump is designed for the testing of rubber hose. We do not recommend it for any other application.
2. Adequate steps should be taken to protect property and personnel in the event of a failure during a test. These steps should include, but are not limited to the
following:
a) Only trained personnel should conduct hydrostatic testing. b) Use of safety glasses or shields for personnel conducting test and
witnessing test.
c) All personnel should be perpendicular to the test sample and at least
15 feet away.
d) Place test sample in a protective enclosure. e) Restrain both ends of the test sample to prevent hose from whipping in
case of a failure.
f) If testing is done outside of a protective enclosure, restrict the movement
of the couplings by the use of sandbags or other means.
g) Use only water as a test uid.
3. All incidental ttings, intermediate hose and piping should be rated at 3000 psi
minimum.
4. Before removing or adjusting any part of the pumping system or test sample the
following precautions should be exercised:
a) Shut off pump. b) Shut off water supply.
c) Release pressure inside the test specimen (hose) through bleed valve.
3Electric Test Pump Dixon 800.355.1991