4040RD — Molded Flapper Seat Swing Check 4” Manifold with Round Flange 4040TE — Molded Flapper Seat Swing Check 4” Manifold with Threaded Ends
4041RD — Metal Seat Swing Check 4” Manifold with Round Flange 4041TE — Metal Seat Swing Check 4” Manifold with Threaded Ends
4042RD — Silicone Seat Swing Check 4” Manifold with Round Flange 4042TE — Silicone Seat Swing Check 4” Manifold with Threaded Ends
Dixon Bayco USA
Chestertown, Maryland Phone: 410-778-2000 Fax: 410-778-4702 Toll Free: 800-355-1991 E-mail: dixonbayco@dixonvalve.com
www.dixonbayco.com
Dixva, S. de R.L. de C.V.
Monterrey, N.L Phone: 01-800-00-DIXON (34966) Fax: 01-81-8354-8197 E-mail: contactenos@dixonvalve.com.mx
www.dixonvalve.com
Dixon (Asia Pacific) Pty Ltd
Wingfield, South Australia Phone: +61 8 8202 6000 Fax: +61 8 8202 6099
E-mail: enquiries@dixonvalve.com.au
www.dixonvalve.com.au
For
Part Numbers:
For Sales & Service Contact
Canada:
Dixon Group Canada Limited
Innisfil (Barrie), Ontario Phone: 705-436-1125 Fax: 705-436-6251 Toll Free: 877-963-4966 E-mail: isales@dixongroupcanada.com
www.dixongroupcanada.com
Europe:
Dixon Group Europe Ltd
Preston, England Phone: +44 (0)1772 323529 Fax: +44 (0)1772 314664 E-mail: enquiries@dixoneurope.co.uk
www.dixoneurope.co.uk
1 090093 R6
Important: To properly operate and maintain your Bayco 4040 / 4041 / 4042 swing check valve,
the following instructions are provided. Please read with care as improper handling or maintenance may cause a hazardous condition.
Caution
: Do not modify your Bayco Swing Check Valve for any reason. It could result in a
hazardous condition causing operating difficulties or malfunction. Disassembly or tampering will void the product warranty.
Installation
: Bayco swing check valves are properly adjusted, tested and ready to use upon leaving the factory. Swing check valves are designed to be tough and to provide long service with reasonable care and handling. Ensure arrow is pointing downstream of product flow when installing. Apply appropriate gasket for round-flanged model (4040RD / 4041RD / 4042RD).
Temperature
: Bayco 4040 swing check valve is not recommended for direct blower mounted service. For direct blower mounted service use either the 4041 swing check valve (metal-to­metal seat) or the 4042 swing check valve (silicone-to-metal seat).
INSPECTION / MAINTENANCE
: Swing check valves can fail to operate if not properly
maintained. Frequently check for damage, loose or missing parts. Swing check valves assure one-way airflow during the off loading or unloading of product. Swing check valves prevent back flow of product into the blower or piping system. These safety devises consist of a simple flapper valve that swings clear of the air stream during the normal off-loading operation, but will immediately close when there is an air stoppage or airline pressure reversal. Once installed, the valves are often ignored. However, they are a crucial element in the proper operation of the dry bulk air transfer systems and the protection of expensive blower equipment.
Swing check valve simplicity and historical durability are probably the reason for inspection complacency. But, swing checks are subject to temperature extremes and vibration fatigue that can affect wear and longevity. Wear in particular can result as flapper and hinge mechanisms vibrate constantly during road travel. Also remember that blowers raise intake air temperatures by as much as 200F. That means if the outside is 100F, then airline plumbing (including swing checks) can reach 300F. High temperatures combined with pulsation stress from the blower and road travel vibration creates a hostile working environment that warrants performance inspections on a regular basis.
There are two basic ways to inspect swing checks: (a) visual/manual, on the tanker and (b) removed from tanker, on a test stand.
NOTE: 4041RK1 and 4042RK1 flapper replacement kits will normally not be compatible with 4040 style bodies that were manufactured prior to March 2007. Any 4040 style bodies manufactured after March 2007 will be compatible with these 4041RK1 and 4042RK1 flapper replacement kits.
To achieve compatibility a sub kit is included in 4041RK1 and 4042RK1 that includes shorter axial shafts and smaller torsion springs that will enable the 4041 and 4042 style flappers to fit inside 4040 bodies that were manufactured prior to March
2007.
2 090093 R6
WARNING: THE SMALLER TORSION SPRINGS WILL NOT ALLOW THE 4041 AND 4042 STYLE FLAPPERS TO FULLY SEAT IF THE VALVE IS MOUNTED VERTICALLY UPSIDE DOWN. ENSURE THAT THIS MOUNTING ORIENTATION IS AVOIDED IF THE SMALLER TORSION SPRINGS ARE USED.
Inspection Procedure:
The complete valve assembly may be removed and replaced without removing the valve body from the system. Please note that the shafts and springs are designed for left and right orientation, ensure that these components are located correctly. The colored spring should be used in conjunction with the right hand threaded shaft.
a) Remove the inspection cap/cover and hand operate valve to ensure springs are in good
working order and flapper seats properly without restriction.
b) Whilst pulling the flapper forwards, pull upwards on the valve yoke to withdraw the
complete flapper assembly (take care to ensure that springs are secure during valve withdrawal).
c) Inspect valve seat and valve for wear or gaps. d) Inspect for product stuck in flapper assembly or valve seat causing the flapper to hang open.
Should problems be encountered, replace valve immediately.
If springs are replaced, please ensure that, after replacement, the valve assembly is free to swing to the fully open position (90°) without excessive resistance. If excessive resistance is
felt:
1. Ensure that the springs are fully pressed onto the shaft
2. Reduce spring pre-load by moving torsion spring legs to alternative pre-load stop. The
correct amount of pre-load allows the valve to be freely opened to 90°.
IMPORTANT: Your Bayco 4040 / 4041 / 4042 swing check valve is designed for minimal flow
restriction and low pressure drop during operation. The valve return springs are designed to provide sufficient pre-load to return the valve to the closed position with only limited pre­load. Excessive pre-loading of the return springs may lead to premature failure.
Inspection Frequency
: Swing check valves should be routinely inspected as part of a preventative maintenance schedule for dry bulk tankers. The units should be given, at a minimum, a visual/manual inspection e very 2-3months. Do not use anything other than genuine Bayco parts in your Bayco swing check valve. Repair kits are available for all replaceable parts (refer to parts breakdown for details). Use of non-approved or modified parts can result in a hazardous condition due to operating difficulties or operation malfunction. Modification or tampering will void the product warranty.
CAUTION: Do not attempt to inspect the valve while in use; this may result in severe damage
or injury.
DIXON BAYCO WARRANTY: For complete Warranty information, please refer to the inside back cover of the latest Dixon Catalogue.