Dixon 4530SG, 4540SG Operating Instructions Manual

1
Maintenance & Operating Instructions
For
4530SG & 4540SG Sight Glass Kit
Part Numbers:
4540SG-RK1 & 4540SGV-RK1
USA:
Dixon Bayco USA
Chestertown, Maryland Phone: 410-778-2000 Fax: 410-778-4702 Toll Free: 800-355-1991 E-mail: dixonbayco@dixonvalve.com
www.dixonbayco.com
Canada:
Dixon Group Canada Limited
Innisfil (Barrie), Ontario Phone: 705-436-1125 Fax: 705-436-6251 Toll Free: 877-963-4966 E-mail: isales@dixongroupcanada.com
www.dixongroupcanada.com
Mexico:
Dixva, S. de R.L. de C.V.
Monterrey, N.L Phone: 01-800-00-DIXON (34966) Fax: 01-81-8354-8197 E-mail: contactenos@dixonvalve.com.mx
www.dixonvalve.com
Europe:
Dixon Group Europe Ltd
Preston, England Phone: +44 (0)1772 323529 Fax: +44 (0)1772 314664 E-mail: enquiries@dixoneurope.co.uk
www.dixoneurope.co.uk
Asia Pacific:
Dixon (Asia Pacific) Pty Ltd
Wingfield, South Australia Phone: +61 8 8202 6000 Fax: +61 8 8202 6099
E-mail: enquiries@dixonvalve.com.au
www.dixonvalve.com.au
For Sales & Service Contact
090110 Rev1
2
4540SG / 4530SG SIGHT GLASS REPLACEMENT GUIDE
DISASSEMBLY
CAUTION: SAFETY GLASSES MUST BE WORN DURING DISASSEMBLY AND SERVICE.
Figure 1 - Tools required for maintenance and part replacement
1. Remove the retaining ring from assembly.
2. Drill two holes in the sight glass in the uppermost location as shown in figure 2. Holes should be aligned
Figure 2 Hole Drilling Location
090110 Rev1
3
3. It is recommended to apply penetrating oil to ease removal of the sight glass.
4. Refer to figure 3-4 and insert the screw driver or round bar through the holes and push down on the sight glass until it is free from the first o-ring. Once the sight glass passes the first o-ring, push the sight glass at the top portion of the adapter body with the screw driver. See Figure 4.
5. After the sight glass and o-ring have been removed, thoroughly clean the o-ring groove to remove any debris and penetrating oil.
Figure 3 – Sight glass removal
Figure 4 – Sight glass removal
090110 Rev1