Dixon 25 TON RAM User Manual SEC06

25 Ton Ram Operating Instructions
Section 6
Internal Expansion of Steel & Stainless Steel Stems
Dixon Valve & Coupling Company
800 High Street Chestertown, MD 21620
ph: 8003551991 fax: 8002834966
www.dixonvalve.com
25 Ton Ram Instruction Manual Internally Expanded Steel & Stainless Steel Stems
(refer to Converting Swaging to Expansion section). Before you begin make sure the ram is fully retracted. Select the proper Pull Rod.
For 1” thru 1 1/2” use Part Number
25RODSMALL
For 2” thru 4” use Part Number 25RODLARGE (note that picture is showing 25RODLARGE)
Screw the short threaded end of the rod into the face plate of the 25IXATTACH.
Select the corresponding Adapter Plate (s) for the size and type of fitting you are installing.
The 2” thru 4” adapters have two recesses. The small diameter recess is to be used with stems having NPT*, Victaulic or a plain end. The larger diameter recess is used for stems with the “Heavy Duty/California Style” end. * See note on page 4.
1
2
Assuring that the recesses are facing outward towards the operator, slide the adapter plate over the pull rod until it reaches the base of the 25IXATTACH. Tighten the set screws to secure the adapter.
Lubricate the I.D. of the stem with Crisco® (recommended) or a high viscosity oil or heavy duty grease.
3
4a
1Section 6