25 Ton Ram Operating Instructions
Section 6
Internal Expansion of Steel & Stainless Steel Stems
Dixon Valve & Coupling Company
800 High Street • Chestertown, MD 21620
ph: 800•355•1991 fax: 800•283•4966
www.dixonvalve.com

25 Ton Ram Instruction Manual Internally Expanded Steel & Stainless Steel Stems
(refer to Converting Swaging to Expansion section).
Before you begin make sure the ram is fully
retracted. Select the proper Pull Rod.
• For 1” thru 1 1/2” use Part Number
25RODSMALL
• For 2” thru 4” use Part Number 25RODLARGE
(note that picture is showing 25RODLARGE)
Screw the short threaded end of the rod into the face
plate of the 25IXATTACH.
Select the corresponding Adapter Plate (s) for the
size and type of fitting you are installing.
The 2” thru 4” adapters have two recesses. The small
diameter recess is to be used with stems having NPT*,
Victaulic or a plain end. The larger diameter recess is
used for stems with the “Heavy Duty/California Style”
end. * See note on page 4.
1
2
Assuring that the recesses are facing outward towards
the operator, slide the adapter plate over the pull rod
until it reaches the base of the 25IXATTACH.
Tighten the set screws to secure the adapter.
Lubricate the I.D. of the stem with Crisco®
(recommended) or a high viscosity oil or
heavy duty grease.
3
4a
customer service 800•355•1991
1Section 6

25 Ton Ram Instruction Manual Internally Expanded Steel & Stainless Steel Stems
Lubricate the O.D. of the small half (tapered end) of
the corresponding IX plug with Crisco®
(recommended) or a high viscosity oil or heavy duty
grease.
Slide the stem over the pull rod and into the recess of the
adapter plate with the connection side of the stem facing
the ram. Screw on (or slide) the IX plug, small end first,
onto the pull rod and into the shank of the stem. For 2” and
above screw the retaining nut on until it contacts the plug.
Note: 25RODLARGE is shown. Move the stem slightly to
allow for slack and hand tighten the plug or nut until it is
snug. Lubricate the rest of the O.D. of the plug.
Hint: When doing more than 1 hose assembly of the same
I.D. size take the time to screw the pull rod further into the
face plate of the 25IXATTACH. This will allow for a
shorter cycle time.
4b
4c
Accurately measure the hose O.D. with a diameter tape.
Select the correct IX ferrule from the DPL based upon
the hose O.D. just measured.
Note: Always measure both hose ends for accurate
ferrule selection.
Make sure the hose end is cut square. Slide the ferrule
over the hose until the turned over end of the ferrule
contacts the end of the hose. Place a mark on the hose
at the junction of the ferrule and hose. Move the ferrule
away from the hose end 1/4” and place another mark at
the junction of the hose and ferrule. This will ensure that
the proper rubber displacement or pocket is maintained
during the expansion process.
5
6
customer service 800•355•1991
2Section 6

25 Ton Ram Instruction Manual Internally Expanded Steel & Stainless Steel Stems
Slide the hose with the ferrule on over the shank until
the ferrule contacts the shoulder of the stem. Make
sure you align the ferrule with the second mark from
step 6. Make sure the pocket has been maintained.
Important! If there is an insufficient pocket for the
rubber to displace into, damage may occur to the stem,
ferrule and/or hose.
While holding the hose and ferrule firmly against the
stem shoulder, engage the Ram by stepping on the foot pedal
(or depressing the “ON” button on the remote control.) The
internal expansion operation is complete when the hose and
stem assembly is pushed completely over the internal expansion plug. Release foot pedal or “ON” switch.
Note: If the gauge reads 10,000 PSI before internal expansion is
complete, stop. Contact Dixon for further assistance. During
internal expansion never stand directly in front of the Ram.
V isually inspect the coupling and clean excess
lubricant from the stem I.D.
7
8
* ASSEMBLY PROCEDURE For 2 1/2” THREADED MALE STEMS:
In order to prevent possible thread collapse on 2 1/2” Male NPT Stems during installation, it is recommended that a female threaded adapter be installed prior to installation. The adapter part # is M011-384 for
the 2 1/2” male stem. Following is the procedure for installation:
1. Lubricate stem ID and small end of expansion plug.
2. Thread M011-384 onto threads of the male stem hand tight ONLY!
3. Slide stem over pull rod thread adapter end first.
4. Seat M011-384 onto OUTER recess of the adapter.
5. Follow normal IX procedure.
6. When the assembly is removed from the pull rod, remove M011-384 and clean the stem ID of
excess lubricant.
If you have any questions, please feel free to contact our Engineering Department.
Dixon Valve sells Steel Internal Expansion Fittings and Stainless Steel. Verify that the correct plug and
adapter plates are being used when installing fittings. Also note that with food grade fittings a different
lubricant may be needed. If you need assistance please contact your Dixon Representative or call any
Dixon Branch.
Dixon Valve and Coupling Company recommends that all
hose assemblies be tested as recommended by the Rubber Manufacturers Association.
customer service 800•355•1991
3Section 6

25 Ton Ram Instruction Manual Internally Expanded Steel & Stainless Steel Stems
Typical Setup - 25 Ton Ram, Internal Expansion
customer service 800•355•1991
4Section 6