12 Indoor and Outdoor installations
14 Flex Joint and Drain Hose diagrams
16 Line Set con guration
17 Air Handler installations
Sizing Chart
21 Dimensions and Capacities
Technical Information
22 General data and safety information
Mini Component Guide
23 Product information and product layout
DiversiTech SpeediChannel™ System
DiversiTech SpeediChannel™ is an innovative channel system used to
cover air conditioning line sets. The two part system has a base and a
cover. The base is fastened to a wall or ceiling, then a clever little plastic
clip (SpeediClip™) snaps into a channel already molded into the base.
SpeediClip™ is the fastest, most convenient way to complete a line set
cover installation. Then, using standard cable ties, the line set, cables, control wires, and/or condensate drain line are fastened in place. The cover
then simply snaps on top of the base.
The SpeediChannel™ system is available in three widths – 3”, 4”, and 6”.
Each piece of SpeediChannel™ is 6-1/2 feet long. A complete line of couplings, elbows, and tees are available for the SpeediChannel™ system.
Manufactured from rigid PVC, the SpeediChannel™ system is a natural
color that is a very close match to the typical mini split condensing unit
case. However, the SpeediChannel™ system can be painted as desired
to match any wall color. The PVC used in the SpeediChannel™ system is
resistant to UV light, and is UL rated.
DiversiTech recommends attaching the
base to the wall or ceiling and the line
sets to the system every 15” to allow for
the system to carry the full weight of the
line sets.
The SpeediChannel™ system can also
be used inside.
I
N
T
R
O
D
U
C
T
I
O
N
23
Page 3
Features and Bene ts
I
N
SpeediClip™
T
R
O
D
U
Paintable
C
T
Natural color
I
O
N
Large size
• SpeediClip™ simply slides into place on a railing molded
into the inside of the SpeediChannel™ allowing for
single person installation. Competitive products must be
screwed in place
• The SpeediChannel™ can be easily customized to any
wall construction.
• The original natural color blends well with almost any wall
construction aesthetic.
• DiversiTech’s large SpeediChannel™ size is a full 6” channel — unlike competitors’ products which are only 5-1/2”.
which is extremely time consuming.
Features and Bene ts
Single piece wall sleeve
20mm drain line with
double connections
True Y connection
English packaging
• Competitive products are multi-part which is cumbersome.
• Versatile — fits 16, 18, or 20mm drain line.
• Drainline Y is inline. It does not branch.
• Competitive products have Japanese on the boxes, potentially leading to product selection errors.
I
N
T
R
O
D
U
C
T
I
O
N
Tight t corner and at
bottom channel design
Stainless steel screws
Flat wall escutcheon
Integrated ex joint
Long radius 90º bend
45
• The flat bottom channel sits on surfaces easier and fits into
corners better. It can be silicone sealed against the wall.
• Stainless steel screws will not rust.
• Competitive products have a larger escutcheon that is not
aesthetically pleasing and wastes space.
• Competitive products require a joiner piece to couple
the flex joint to their systems. The DiversiTech flex joint
slides right into the end of the SpeediChannel™ with no
additional joiner piece.
• DiversiTech’s long radius 90º bend allows for a larger
bending radius for the line set, making installation easier.
Page 4
Step 1
S
Y
Attach the SpeediChannel™ base to the wall about every 15 inches
S
with screws suitable for the wall construction (siding, stucco, brick, etc.).
T
Screw through the center of the molded rail. Slide the
E
connecting piece (elbow, union, tee, etc.) under the
M
SpeediChannel™ before attaching the end of the
channel to the wall. When cutting lengths of
I
SpeediChannel™, allow 1/8” gap between
the end of the SpeediChannel™ and the
N
stop inside the fi tting to allow for
S
thermal expansion.
T
A
L
L
A
T
I
O
N
Step 2
Slide one SpeediClip™ with cable tie about every 20 inches along the inside sliding rail.
S
Y
S
T
E
M
I
N
S
T
A
L
L
A
T
I
O
N
6
7
Page 5
Step 3
S
Y
Install the line set, drain line, and wires inside the SpeediChannel™. Test the equipment
S
installation prior to tightening the cable ties. Tighten the cable ties snug, but not so tight they
T
damage the tubing insulation or kink the drain line. Trim excess length from the cable tie.
E
M
Step 4
Attach the SpeediChannel™ to the base.
S
Y
S
T
E
M
I
N
S
T
A
L
L
A
T
I
O
N
89
I
N
S
T
A
L
L
A
T
I
O
N
Page 6
Step 5
S
Y
Attach the fi tting covers with the screws provided.
S
T
E
M
Step 6
When complete, paint the SpeediChannel™
to match surface of installation (if desired).
S
Y
S
T
E
M
I
N
S
T
A
L
L
A
T
I
O
N
1011
I
N
S
T
A
L
L
A
T
I
O
N
Page 7
I
N
S
T
A
L
L
A
T
I
O
N
Typical Detail of Indoor InstallationTypical Detail of Outdoor Installation
A
B
A
C
H
I
N
S
T
A
L
L
A
T
I
O
N
D
I
A
G
R
A
M
S
E
D
C
A
C
1213
A
F
D
I
A
G
R
A
M
S
Page 8
I
N
S
T
A
L
L
A
T
I
O
N
Typical Detail of Flex Joint Application
Typical Detail of Cut-out for Drain Hose
I
N
S
T
A
L
L
A
T
I
O
N
D
I
A
G
R
A
M
S
G
A
1415
A
Notch bottom half as
shown here.
D
I
A
G
R
A
M
S
Page 9
I
N
S
T
A
L
L
A
T
I
O
N
D
I
A
Insulated
G
Refrigerant
R
A
M
S
Drain Hose
Line
Typical Line Set, Cable, and Drain
Hose Con guration
SpeediChannel™
SpeediClip™
SpeediChannel™
Top
Bottom
Basic Application - 1 Air Handler
C
A
B
A
J
I
N
S
T
A
L
L
A
T
I
O
N
D
I
A
G
R
A
A
M
S
K
1617
Page 10
I
N
S
T
A
L
L
A
T
I
O
N
D
I
A
G
R
A
M
S
Vertical Dual Air Handler
System Application
C
C
A
J
A
Horizontal Dual Air Handler
System Application
A
L
A
A
J
A
I
N
S
T
A
L
L
A
T
I
O
N
C
D
I
A
G
R
A
M
S
K
1819
K
Page 11
I
N
Building with Di erent Wall
Thickness Application
S
T
A
L
L
D
A
T
I
O
N
D
I
E
A
A
A
G
Sizing Chart and Selection Information
Maximum Line Set, Drain Pipe, and Cable Capacity using 3/8” Insulation
Model 230-D3 230-D4 230-D6
Dimensions 3” x 2-1/2” 4” x 2-3/4” 6” x 3”
Length 78” 78” 78”
Mini Split Systems – Liquid and Suction Line with 3/8” Insulation
Liquid Line 3/8” 2 x 1/4” 1 x 1/4” + 2 x 3/8”
Suction Line 5/8”2 x 3/8” 1 x 1/2” + 2 x 5/8”
Drain Hose 3/4” OD 2 x 3/4” OD 3 x 3/4” OD
Power Cable 1 x UF 14-3 2 x 1/2” SealTite 3 x 1/2” SealTite
Control Cable 1 Pair 18 AWG 2 Pairs 18 AWG 3 Pairs 18 AWG
Nominal Tonnage 1–3 Tons 1x3 Ton or 2x1 Ton 1x3 Ton or 2x2 Ton
S
I
Z
I
N
G
C
H
A
R
T
R
A
M
S
G
Conventional Split Systems – Liquid Line Plain, Suction Line with 3/8” Insulation
Liquid Line 3/8” 3/8” 3/8”
A
K
Suction Line 3/4” or 7/8” 1-1/8” 1-1/8”
Drain Hose 3/4” PVC 3/4” PVC 3/4” PVC
Power Cable 1 x UF 14-2 1 x 1/2” SealTite 1 x 1/2” SealTite
Control Cable 1 Pair 18 AWG 1 Pair 18 AWG 1 Pair 18 AWG
Nominal Tonnage Up to 3.5 Tons 4–5 Tons 7.5 Tons and up
2021
Page 12
Technical Data
T
E
C
H
N
I
ColorNatural
Size
C
Material Weather Resistant PVC, UV Stabilized and Fire Resistant
A
Fire Rating Meets UL 94V.-0
L
Temperature Range -4˚F TO 140˚F
Weather Resistance Tested to over 2,000 hours
Fixing Screws Stainless Steel
S
230-D3: 3” x 2 -1/2” OD 230-D4: 4” x 2-3/4” OD 230-D6: 6” x 3-1/8” OD Standard Length: 78”
P
SpeediChannel™
CATALOG NO. DESCRIPTION QTY. NEEDED
2 30-D3 3” SpeediChannel™ – 6-1/2’ long
2 30-D4 4” SpeediChannel™ – 6-1/2’ long
2 30-D6 6” SpeediChannel™ – 6-1/2’ long
DiversiTech Corporation is North America’s
largest manufacturer of equipment pads and a
leading manufacturer and supplier of components and related products for the heating,
ventilating, air conditioning, and refrigeration
(HVACR) industry.
Headquartered in the Atlanta, GA metropolitan
area, DiversiTech manufactures a suite of
products which includes a wide range of
mechanical, electrical, chemical, and structural
parts for HVACR and electrical systems, and
swimming pool installations. The company
maintains manufacturing and distribution
facilities in key U.S. locations, Europe, and in the
Far East. DiversiTech has enjoyed a continued
history of successful growth and has acquired
industry-recognized names including Devco®
Enterprises, Wagner® Manufacturing, The Black
Pad®, Hef-T-Pad™, and Specialty Chemical.
Send edits / corrections / comments on this
catalog to [email protected]