DIVERSITECH CP-16, CP-16-230 Installation And Safety Instructions

Condensate Pump
Installation and Safety Instructions
CP-16 CP-16-230
CP-16
CP-16-230
Rated Voltage
Rated Current Draw
Input Type
Head Height
Flow Rate at Zero Head
Temperature Rating
Product Dimensions (LxWxH)
Product Weight
120 Volts / 60 Hz
1.9 Amps
USA 3-prong plug
16 . maximum
1.2 GPM
• Continuous duty 140F°
• Max inlet temperature 160F°
• Not suitable for contact with steam or gasses that exceed 160F°
4.5” x 10.75“ x 6.5”
3.8 lbs.
220 Volts / 60 Hz (208-230)
1.0 Amps
NEMA 6-15 plug
16 . maximum
1.2 GPM
• Continuous duty 140F°
• Max inlet temperature 160F°
• Not suitable for contact with steam or gasses that exceed 160F°
4.5” x 10.75“ x 6.5”
3.8 lbs.
Inlet Height from Base
Included Accessories
Wiring Color References
3.5”
• Instruction Sheet
• Hang Tabs
• Plug Protector
• 4’ Remote Shuto Leads
• Inlet Cover
Black - Live/Hot White - Neutral Green - Ground
All installations must conform to NEC requirements
3.5”
• Instruction Sheet
• Hang Tabs
• Plug Protector
• 4’ Remote Shuto Leads with Insulated Terminals
• Inlet Covers (3)
Brown - Live/Hot Blue - Neutral Green/Yellow - Ground
All installations must conform to NEC requirements
Limited Warranty
All pumps manufactured by or for DiversiTech Corporation (the Compa­ny) and sold by the Company under the DiversiTech brand are warrant­ed to be free of defects in workmanship and materials for a period of 24 months from date of sale from the distributor to the contractor. The Company will credit, repair or replace, at its option, any Pump if deemed defective within this time period. All products returned to the Company must include a return authorization issued by the Company. The returned product should be suitably packaged and shipped prepaid from the point of shipment to the point designated in the Company's return authorization.
This warranty is a limited warranty and shall be in lieu of any other warranties, expressed or implied, including, but not limited to, any implied warranty of merchantability or tness for a particular purpose. There are no other warranties that extend beyond the description of the face hereof. The liability of the Company arising out of it's supply of said products, or their use shall not in any case exceed the cost of correcting defects in the products as set forth above. The Company shall not be liable for any costs or damage incurred by its customers in the removal or replacement of defective products from units in which the products have been assembled. In no event shall the company be liable for loss of prots, indirect, consequential, or incidental damages.
SAFETY WARNING
FOLLOW ALL SAFETY INFORMATION TO REDUCE POTENTIAL ELECTRICAL SHOCK.
DISCONNECT POWER BEFORE SERVICING UNIT. PUMP MUST BE PROPERLY GROUNDED.
NEVER USE THE PUMP TO MOVE FLAMMABLE LIQUIDS.
NEVER USE THE PUMP IN AN EXPLOSIVE GAS ENVIRONMENT,
OR WHERE GAS FUMES OR VAPOR MAY BE PRESENT.
ALWAYS DISCONNECT THE POWER PRIOR TO MOVING,
ADJUSTING OR SERVICING THE PUMP OR ATTACHED SYSTEMS.
WARNING: RISK OF ELECTRIC SHOCK
THIS PUMP MUST BE PROPERLY CONNECTED TO POWER FOLLOWING THE NATIONAL
ELECTRIC CODE NEC. FAILURE TO FOLLOW THESE WARNINGS WILL VOID WARRANTY AN
COULD RESULT IN AFATAL ELECTRIC SHOCK. A GREEN LED WILL INDICATE IF POWER IS
AVAILABLE. THIS PUMP IS SUPPLIED WITH A GROUNDING CONDUCTOR AND GROUND
INGTYPE ATTACHMENT PLUG. TO REDUCE THE RISK OF ELECTRIC SHOCK, BE CERTAIN THAT
IT IS CONNECTED ONLY TO A PROPERLY GROUNDED, GROUNDINGTYPE RECEPTACLE.
DiversiTech Corporation 6650 Sugarloaf Parkway
©2019 DiversiTech Corporation PRINTED IN VIETNAM
Suite 100
Duluth,GA 30097
800.995.2222
FAX 770.593.8600
General Information
Thank you for the purchase of this DiversiTech condensate pump. This pump is designed to automatically remove the condensate water that collects from appliances such as air conditioners and de-humidiers.
The pump has a built-in tank that collects the water from the appliance. When the water collected reaches sucient level inside the pump tank, the pump switches on and pumps the water to a remote location for disposal. When the tank is suciently empty the pump automatically switches o.
The pump is capable of liing water to its rated height and is equipped with a check valve that prevents water from owing back into the tank when the pump shuts o.
The pump is also equipped with a switch that activates when the water in the tank reaches an overow condition. The overow safety switch may be connected to turn o the appliance if the high water condition occurs.
Pump should be stored indoors. The chosen location should be clean and dry.
Unpacking
Carefully open the carton to avoid damage to the pump. Do not use a knife or other sharp object that may scratch the pump’s cover. Aer opening the carton, look for damage. If damage is found le a claim with the freight carrier.
CHECK FOR
SHIPMENT
DAMAGE
Power Source
Connect power cord to a supply voltage and frequency that matches what is shown on the pump nameplate. Source voltages lower than the rated supply can reduce performance and cause the pump to overheat.
Pump Installation
The pump must be level and should be placed on a solid surface or oor. The pump has rubber feet to reduce noise and keep it in place during operation.
Do not use this pump in the presence of spraying or standing water, it may cause a shock. This pump is not suitable for use in Class I or Class II locations (explosive gas or dust).
Do not cover the pump air vents. The pump is air cooled. Do not cover the vent holes located on the top or sides of the pump housing. The pump may be operated continuously as long as the air vents are not covered.
Mounting
The condensate pump is equipped with optional mounting tabs which allow the tank to be screwed to a wall or equipment side panel. The screw-to-screw distance is 10-1/16”. When mounting into drywall or concrete walls the screws must have anchors which provide the necessary support in the wall material.
Inlets
4 inlet holes are located in the top deck of the pump. Flexible vinyl tubing or PVC may be connected to any of the pump inlets. Knock out covers are provided to cover unused inlets. Be sure to knock out only the hole used for the inlet pipe to prevent the pump from collecting debris or insects.
Tubing installed into the inlet holes must be straight. The tubing must not bend inward where it will interfere with the pump or oat mechanism.
When using rigid tubing such as PVC, be sure to cut the end at an angle. This will allow the condensate water to drain freely and keep the tubing end from being blocked by the tank bottom.
It may be desirable to use a “P” or “U” trap between the AC unit and the condensate pump to provide a liquid barrier to air ow from the air condi­tioner. These types of “traps” always contain some water which blocks the ow of air from the AC unit which is wasteful and can cause other prob­lems such as accelerated algae growth.
Outlets and Tubing Connections
The pump is equipped with a combination barb-type tting and check valve. The tting allows the connection of 3/8” exible vinyl tubing such as DiversiTech “CVT” clear vinyl. Attach the tubing by pressing it over the barb tting and secure with a screw type hose clamp.
Route the tubing up and away from the pump; avoid compressing or kinking the tubing. The tube route should be the shortest possible distance from the pump to the building exterior or other drain location. For best results the distance that the water must go UP should be shorter than the distance that it goes DOWN. With the longer DOWN tubing, the length will help siphon the condensate from the tank, speeding the pump out time.
Pump Electrical Connections
Connect the pump power to a properly grounded outlet capable of providing power that exceeds the requirements listed on the pump name­plate. Avoid the use of extension cords wherever possible. The pump must be operated by a continuous source of power and must not be connected to switched outlets or other power supplies that may be inadvertently or automatically turned o.
All aspects of the installation must conform to requirements of the NEC, and any applicable local codes.
Safety Switch
The pump safety switch should be used on 24V Class II control circuits only. The pump safety switch connections are to be connected in series with the 24 Volt thermostat circuit to shut o A/C systems should an overow condition occur. An optional DiversiTech Universal Alarm may be connected to indicate system trouble.
Pump Operation
Apply power by plugging in the pump. Test oat and safety switch by manually lling the tank.
Test Safety Switch operation (if used) to be sure that the A/C system shuts down when the pump has reached an overow condition.
Leak Check: Operate the pump by lling tank to trigger operation.
Pump Maintenance and Disassembly
Always disconnect power before performing maintenance.
Periodically inspect the Pump tank to assure it is free of accumulated dirt or sludge. Do not use solvent cleaners. Clean Tank with soap and warm water only. The check valve may be removed for cleaning or replace­ment by unscrewing with a 9/16 wrench. (illustration)
Clean inlet and outlet piping. Tubing may be cleared of slime or debris instantly with a Wagner brand Gallo Gun tool and Swoosh cartridges.
Reassemble system and check for correct operation.
DOC32302