I. Application:
A. Purpose:
The purpose of the EZ Series Fixed Access Ladder is to
provide an OSHA Compliant access to roofs, platforms and
walkways.
B. Limitations:
Rated Number of simultaneous users- (1)
Load Rated: 800 lbs.
C. Standards:
Please refer to all families of standards regarding occupational safety for more
information on work positioning systems and fall protection. These include
ANSI, OSHA, and any applicable local or state requirements. Compatibility shall
follow all requirements of OSHA 1910.23(d).
II. Installation:
A. Installation Tools and Materials:
*Plan your system prior to installation. Consider any factors
that may affect a user’s safety. Key points to consider are:
anchorage, sharp edges, obstructions and rescue.
Measure and layout stand-off locations- 1’-9¾”
between each Ladder Standoff
Mount stand-offs to structure. Secure with bolts.
Standoffs should be installed to ensure the ladder
has a minimum of 7” clearance between the rungs
and the structure. This 7” clearance applies to
obstructions on the structure being affixed to.
Mount Ladder Rung adapters to Stand-offs. Secure
with bolts.
Place ladder on Ladder Rung Adapter.
Install clamp plate over the ladders rungs and
secure with bolts.

Diversified Fall Protection
24400 Sperry Drive
Cleveland, OH 44145
B. Important measurements
When Installing:
Climbing width: must be a minimum of 16 inches- OSHA 1910.23(b)(4)
Stand-off distance of 7 inches. 7 inches minimum must be measured from the mid-
point of the ladder rung to the nearest permanent object in back of the ladder.
OSHA 1910.23(d)(2). **See Diagram on Last Page.
Any Fixed Access Ladder is required to have a fall protection system in place if it
exceeds 24 feet according to OSHA 1910.28(b)(9)
The last rung of the ladder must be either in line of below the roof and no more than
12” below.
Ladder Features:
Rung Width: 20”
Walk through: 30”
Standoff Brackets: Bolt on, with vertical/horizontal adjustability
Floor/ Bottom mount available
Side Rail Construction: 3” Flat Stock
Hot dipped galvanized finish
10’ maximum modular sections reduce freight costs

Diversified Fall Protection
24400 Sperry Drive
Cleveland, OH 44145
Optional Accessories:
*These accessories may or may not be included depending on individual order
Bolt On Walk Throughs
P-Returns
Safety Gates
Ladder Guards
Parapet Crossovers & Step Systems
Ladder Lifeline Systems
General Notes:
Ladder system has been designed by Diversified Fall Protection per specifications on referenced
drawings. Consult with a qualified engineer before installation system to confirm structure supporting
ladder is capable of supporting ALL intended loads applied to ladder when in use. Diversified Fall
Protection shall not be held liable or responsible for ladders installed by others, other than Diversified
Fall Protection.
Rated Number of simultaneous users- (1)
Load Rated: 800lbs.
Standoff connection scenarios vary and different part numbers may be used. Actual standoff connection
types and bolt patterns may differ from what is depicted in this document. Suggested torque values
(ft/lbs) for ½” ASTM Gr. 5 bolts are as follows: Galvanized/waxed: 61 ft/lbs
Disclaimer:
Follow manufacturer’s instructions wherever applicable. The information provided in this document is
provided as a reference only and the use of it is undertaken entirely at the risk of the user. Diversified
Fall Protection accepts no responsibility or liability for the completeness or accuracy or any install that
may be aided, in full or in part, by this document. Diversified Fall Protection does not and will not
indemnify any individual or company on the installation of ladder or ladders.

Diversified Fall Protection
24400 Sperry Drive
Cleveland, OH 44145