diversey TASKI swingo 760E Instructions For Use Manual

swingo 760E
EN ES ZH
EN .2 ES . 14 ZH . 26
V005 / 12089-82 1638
*12089-82*
Translation of the original instructions of use
t
CAUTION! Always read the instructions of use and
the safety instructions before using the machine for the first time.
The instructions of use must be kept in a safe and well accessible place so that you can refer to them at any time.
Legend:
Caution: This sign designates important informa-
tion. Failure to follow these instructions may result in danger to persons and/or ex­tensive damage to property!
Attention: This sign designates important informa-
tion. Failure to follow these instructions may result in faults and damage to proper­ty!
Notice: This sign designates important information
regarding the efficient use of the product. Failure to follow these instructions may re­sult in faults!
It includes instructions for the work steps that you must carry out in order.
Content
Safety instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Cleaning products . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Further documents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Structural layout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Prior to commissioning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Beginning work with the machine . . . . . . . . . . . . . . . . . . . . . . . 7
End of operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Service, maintenance and care. . . . . . . . . . . . . . . . . . . . . . . . . 10
Malfunctions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Technical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Accessories. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Transport. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Disposal. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Machine dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Intended use
The machine is intended for commercial use (e.g. in hotels, schools, hospitals, factories, shopping centers, offices, etc.). Subject to strict compliance with the instructions of use, these machines are used for the wet cleaning of hard flooring. These machines are exclusively designed for use in interior zones.
Attention: The machine must not be used for polish-
ing, oiling, the application of wax, carpet cleaning or dust removal. The wet clean­ing of parquet and laminate flooring with this machine is at your own risk.
Caution: Changes to the machine that have not
been authorized by Diversey will lead to the expiry of safety marks and CE confor­mity. Using the machine for purposes oth­er than the intended purpose can cause injuries to persons, and damage to the ma­chine and the working environment. Such cases will usually result in the termination of any warranty and possible guarantee claims.
Safety instructions
Due to their design and construction, TASKI machines comply with the relevant essential health and safety requirements of the EC directives; they therefore have the CE sign.
Caution: The machine may only be used by per-
sons who are adequately trained for the use of the machine or who have provided proof of their skills regarding the use of the machine and who are explicitly commis­sioned to use the machine.
Caution: The machine must not be used by people
with reduced physical, sensory or mental capacities, including children or people who lack experience or knowledge.
Children must be supervised to ensure that they do not play with the machine.
Caution: Do not use the machine in rooms where
explosive or highly combustible substanc­es (e.g. gas, solvents, heating fuel, dust, etc.) are stored or processed.
These substances could be ignited by the electrical or mechanical components of the machine.
2
EN
Caution: Do not use the machine for the vacuum
cleaning of poisonous, harmful, caustic or irritating substances (e.g. dangerous dust, etc.). The filter system does not adequate­ly filter out these kinds of substances.
Possible impacts on the health of the user or third persons cannot be ruled out.
Caution: Pay attention to the local situation as well
as to third persons and children! In the vi­cinity of blind spots such as doors or curves in particular, it is important to re­duce speed.
Caution: Do not transport other persons and objects
with this machine.
Caution: In case of malfunction or defect or after
collisions or toppling over, the machine must be inspected by an authorized expert before restarting. The same applies if the machine was left outdoors, immersed in water or subjected to moisture.
Caution: The machine must be stopped immediate-
ly in case of damage to safety relevant parts such as brush covers, power supply cords or covers that enable access to live parts.
Attention: The machine must be protected against
unauthorized use. Therefore, keep the machine in a locked room before leaving it.
Attention: Operate and keep the machine in a dry
and low-dust environment at temperatures between +10°C / + 50 °F and +35°C/ + 95 °F degrees only.
Attention: Only authorized experts who are familiar
with all safety instructions relevant for this machine are allowed to repair mechanical or electrical machine parts.
Attention: Only tools (brushes, pads or similar) that
are specified in these instructions of use under accessories, or which have been recommended by a TASKI consultant, may be used. Any other brushes might im­pair the safety and functions of the ma­chine.
Attention: National regulations for personal protec-
tion and accident prevention as well as the manufacturer's instructions for the use of cleaning solutions must be consistently observed.
Attention: It is forbidden to plug in or unplug the main
power supply cord with wet hands!
Caution: The machine must not be stopped, parked
or stored on slopes.
Caution: The machine must be switched off for any
work carried out on the machine.
Caution: Do not use the machine in rooms with high
electromagnetic interference (electric smog).
Caution: The machine must not be used on slopes
>2%. Sharp cornering on slopes can affect the
stability of the machine and is therefore prohibited. Danger of accident.
Attention: Make sure that the rated voltage stated on
the machine label is the same as the volt­age rating of the plug socket!
Attention: Take care not to damage the power supply
cord by rotating tools (brushes, pads or similar), crimping, tearing or damaging the power supply cord through heat, oil, or sharp objects!
Attention: In case of foam or liquid leakage from the
machine, the suction unit must be switched off immediately.
Attention: TASKI machines and devices are de-
signed such that health risks caused by noise emissions or vibrations can be ruled out according to the current state of sci­ence. See the technical data on page 12.
3
Cleaning products
Notice: TASKI machines are designed in such a
way that optimal cleaning results can be achieved if TASKI cleaning products are used. Other cleaning products may cause mal­functions and damage to the machine or the environment. Therefore, we recommend the exclusive use of TASKI cleaning products.
Faults caused by inappropriate cleaning products are not covered by the guaran­tee.
For further details, please contact your TASKI service partner.
Further documents
Notice: The electric diagram of this machine is
provided in the spare parts list. Please contact your customer service for
further information.
4
Structural layout
8
9
10
7
6
2
3
4
5
1
14
13
12
11
20 1921
15
16
17
18
23
22
max.60°C
max.140°F
EN
1 Switch bracket drive 2 Driving handles 3 Operating hour counter (option) 4 Drain hose cleaning solution (blue cover) 5 Drain hose waste water (red cover) 6 Water regulating set 7 Foot pedal tool 8 Foot pedal squeegee 9 Squeegee 10 Tools (brushes, pads, etc.) 11 Brush unit 12 Cleaning solution switch 13 Suction unit switch 14 Main switch 15 Fresh water tank filter 16 Recovery tank 17 Float (Overfill protection recovery tank) 18 Suction filter 19 Dirt sieve 20 Solution tank 21 Dosage aid 22 Tank lid 23 Tank lid unlocking
5
Prior to commissioning
1
2
2
1
Brush installation Before inserting, please check:
• that the brush does not fall below the red marking (bristles) or 1cm of bristle length.
• the pad for wear and cleanliness before use.
Attention: Do not use brushes which have reached
their wear limit. The wear limit is indicated by the length of the red bristle. Do not use worn or contaminated pads. Use original TASKI brushes only. Failure to observe these instructions may result in inade­quate cleaning results or even floor dam­age.
• The machine must be switched off (main switch).
• Position the tools under the tool unit.
• Plug the power supply cord into the mains socket.
• Switch on the machine (key switch).
Switch lights up
• Unlock the foot pedal and lower the tool slowly.
Squeegee assembly
• The machine must be switched off (main switch).
• Position the squeegee (2) below the squeegee holder (1).
• Press the foot pedal down until the squeegee holder engages.
• Attach the suction hose to the con­nector.
Filling the fresh water tank
Attention: Max. permissible water temperature
60 °C/140 °F. Diversey recommends using cold water
since hot water will adjust to the floor tem­perature as soon as it is in contact with the floor. Thus there are no advantages to us­ing hot water.
• The machine must be switched off.
• Put your hand into the opening be­tween tank cover and tank.
Palms upwards.
• Briefly press the operating lever.
In this way the tool is centered and engaged.
Notice: Lightly moving the machine backwards
and forwards at the driving handle helps it to engage.
• Open the tank cover until the support engages in the tank wall.
• Remove the dosage aid.
• Fill the fresh water tank with water.
Maximum filling level (page 5).
• Tip the tank cover back into its original position and press it down until it locks.
6
EN
Dosing
Attention: Wear gloves, goggles and appropriate
(protective) working clothes when han­dling chemical products!
Notice: Use chemical products recommended by
Diversey only and always observe the product information.
Caution: Using unsuitable products (e.g. products
containing chlorine, acids or solvents) may cause harm to health and severe damage to the machine.
Notice: For a precise dosage, use the scale in the
dosage cup. The filling level mark on the tank corre-
sponds to the mark in the dosage cup. The type of machine is also noted in the dos­age cup!
Beginning work with the machine
Attention: Always wear slip-resistant shoes and ap-
propriate working clothes when working with this machine!
Attention: Start familiarization with the machine by
making your first driving attempts in a free area.
Cleaning start
• Lower the squeegee.
• Plug the power supply cord into the mains socket.
• Switch on the machine (key switch).
Switch lights up
Information on the package of the product
0.5% 1/2 1 x 1/2
1% 1/2 1 x MAX (2 x 1/2)
Dosage cup application
• Fill the product you have measured with the dosage cup into the fresh water tank.
• Slightly lift the tank cover.
• Push the tank cover support slightly inwards.
• Close the tank lid.
• By pushing gently on the front part of the tank cover you lock the tank.
Pre-cleaning
Tank capacity Dosage cup
MAX 1 x MAX
MAX 2 x MAX
Attention: Remove any objects (wooden, metal parts
etc.) from the cleaning surface.
The objects could be catapulted by the ro tating tool, and thereby cause injuries to people and damage to the environment.
• Unlock the foot pedal and lower the tool slowly.
• Switch off the suction unit.
Switch lights up
• Switch off the water pump.
Switch lights up
• Use the quantity control to dose the cleaning solution.
• Pull the switch bracket drive on the driving handle.
The tool starts to rotate and the cleaning solution supply starts.
-
7
Cleaning method
Direct working method: Scrubbing and suction in one work step.
Indirect working method: Applying the cleaning solution, scrubbing and suction in sev­eral work steps.
Notice: More precise details regarding the direct
and indirect working method can be found on the respective method sheet.
Please contact your TASKI customer con­sultant for further details.
Notice: The machine guiding might be impaired in
case of special combinations of flooring/ contamination and cleaning product.
Optionally available wheels can improve the traction of the machine on the floor. Please contact your TASKI customer con­sultant.
Replenishing cleaning solution
Attention: The flooring may be damaged when work-
ing without cleaning solution.
End of operation
• Switch off the water pump.
The cleaning solution supply is stopped.
• Continue to drive a few meters.
Notice: Very important for TASKI contact pads!
• To lift the tool, push the foot pedal
downwards until it engages.
• Drive on for a few meters in order to absorb the remaining drain water.
• Switch off the suction unit.
The switch lights up; the suction en gine stops.
-
Notice: A rattling sound of the pump indicates that
the fresh water tank is empty.
Attention: The pump must never run dry for an ex-
tended period.
• The machine must be switched off.
• Open the tank lid.
• Fill the fresh water tank with water, see page 6.
• Add the cleaning product using the dosing cup.
• Close the tank lid.
Soiled water full
Recovery tank full:
• If the recovery tank is full, the floater will be sucked onto the suction filter.
This will be indicated by a change of the noise by increasing the suction speed as well as residual water at the bottom.
• Drain the recovery tank, see page 9.
• Switch the machine off (ON/OFF) and pull the power supply cord out of the mains socket.
Attention: The machine must now be emptied and
cleaned. Switch off the machine (main switch) and remove the plug from the mains socket.
8
EN
Removing and cleaning the squeegee
• Pull the suction hose from the connector.
• Lift the squeegee with your foot.
• Compress the lock springs. The
squeegee is released and can be re­moved from the squeegee holder.
• Clean the squeegee under running water using a brush.
Notice: Only cleaned and intact blades ensure op-
timal suction results!
Empty and clean the recovery tank and fresh water tank
Notice: Drain water or cleaning solution must be
disposed of in compliance with the nation­al regulations.
Notice: When draining the recovery tank, the reg-
ulations of the detergent supplier regard­ing personal protective equipment of the cleaning solution manufacturer must be observed.
Proceed as follows:
• Take the drain hose out of the holder.
• Remove the dirt sieve (yellow), emp­ty it and thoroughly rinse it under run­ning water.
• Take out the suction filter (yellow) and remove the dirt with a cloth or a soft brush.
• Check the float to make sure it is fully functional and repair any fault
• After you have finished emptying the tanks, screw the red and blue cover back on and hang the hose on the holder.
Attention: Clogged suction filters may impair the suc-
tion performance.
• Reassemble the dirt sieve (yellow) and the suction filter.
• Put the drain hoses back into the holder.
Cleaning the fresh water tank filter Clean the fresh water tank filter after the end of operation.
Clogged filters can inhibit the supply of detergents and thus lead to surface damage.
• The machine must be switched off.
• Unscrew the fresh water tank filter and remove it.
• Rinse the filter thoroughly with clean water.
Notice: The filter is lower than the drain hole of the
tank. A rest amount of cleaning solution will run out only when the filter is removed.
• Open the red or blue cover at the level of the handle, lower the end of the hose slowly and empty the recovery or fresh water tank.
Cleaning the recovery tank and fresh water tank
• Open the tank cover until the support engages in the tank wall.
• Rinse the recovery tank and the fresh water tank thorough-
ly with clean water.
• Put the filter back and twist it closed.
Removing and cleaning the brush
Notice: Clean the brush whenever cleaning work
is completed.
• To lift the tool, push the foot pedal downwards until it engages.
• Rotate the tool counterclockwise away from the tool connection using your foot.
9
• Clean the tool under running water.
3
1
2
Cleaning the machine
Attention: Never clean the machine with a high-pres-
sure cleaner or water jet.
Water ingress in the machine may cause considerable damage to the mechanical or electrical parts.
• Wipe the machine with a moist cloth.
Storing / parking the machine (not in operation)
Notice: The machine must be switched off and the
plug must be removed from the mains socket.
Notice: Store the machine with a lifted squeegee,
lifted brush and open tank lid. Thus, the tank can dry, and the generation of mold and unpleas­ant odors is prevented.
Service intervals TASKI machines are high-quality machines that have been
checked for safety in the factory and by authorized inspectors. Electrical and mechanical parts are subject to wear and aging after a longer period of use.
• In order to maintain operational safety and readiness for use, the machine must be serviced after 450 working hours or at least once a year.
Notice: In case of extraordinary use and/or insuffi-
cient maintenance, shorter intervals are required.
Service center Please always indicate the type and number of the machine
whenever you contact us for order placing or in case of mal­functions.
The required data are provided on the nameplate of your ma­chine. The address of your closest TASKI service partner is provided on the last page of these instructions of use.
Blade replacement
• Lift the tank and turn the dosing aid.
• Lower the tank cover and place it carefully on the dosing aid.
Service, maintenance and care
The maintenance of the machine is a prerequisite for impec­cable operation and a long service life.
Attention: Use original TASKI parts only; otherwise,
any warranty and liability claims will ex­pire.
Legend: ◊ = whenever cleaning is completed, ◊◊ = every week, ◊◊◊ = every month, ⊗ = service lamp
Activity
Draining and cleaning the recovery and fresh water tank (Flextank)
Check the suction filter for contamina­tion and clean it
●9
◊◊
◊◊◊
• Unscrew the star knobs (1), pull the blade body (2) out of the squeegee body and remove the blades (3).
• Now you can turn the blades or replace them.
• Put the blade body (2) back in the squeegee body and screw the star knobs (1) back on.
Page
Clean all yellow marked parts
Clean the brushes 9
Clean the squeegee, check the blades for wear and change them, if necessary
Wipe the machine using a damp cloth 10
Clean the seals of the tank lid, check them for cracks and replace them, if necessary
10
●9
Loading...
+ 27 hidden pages