Dito Dean D20, D60, D80, D50 User Manual

Decathlon Series Gas Fryers (Non-
Installation & Operation Manual
CE)
Dean, a member of the Commercial Food Equipment Service Association, recommends using CFESA Certified Technicians.
24-Hour Service Hotline 1-800-551-8633
AUGUST 2003
*8195698*
DANGER
Adequate means must be provided to limit the movement of this appliance without depending
upon the gas line connection. Single fryers equipped with legs must be stabilized by installing
anchor straps. All fryers equipped with casters must be stabilized by installing restraining
chains. If a flexible gas line is used, an additional restraining cable must be connected at all
times when the fryer is in use.
DANGER
The front ledge of the fryer is not a step. Do not stand on the fryer. Serious injury can result
from slips or contact with the hot oil.
DANGER
Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any
other appliance.
DANGER
Instructions to be followed in the event the operator smells gas or otherwise detects a gas leak
must be posted in a prominent location. This information can be obtained from the local gas
company or gas supplier.
DANGER
The crumb tray in fryers equipped with a filter system must be emptied into a fireproof container
at the end of frying operations each day. Some food particles can spontaneously combust if left
soaking in certain shortening material. Additional information can be obtained in the filtration
manual included with the system.
WARNING
No structural material on the fryer should be altered or removed to accommodate placement of
the fryer under a hood. Questions? Call the Frymaster/Dean Service Hotline at 1-800-551-8633.
WARNING
Do not bang fry baskets or other utensils on the fryer’s joiner strip. The strip is present to seal
the joint between the frypot. Banging fry baskets on the strip to dislodge shortening will distort
the strip, adversely affecting its fit. It is designed for a tight fit and should only be removed for
cleaning.
NOTICE
IF, DURING THE WARRANTY PERIOD, THE CUSTOMER USES A PART FOR THIS ENODI S
EQUIPMENT OTHER THAN AN UNMODIFIED NEW OR RECYCLED PART PURCHASED
DIRECTLY FROM FRYMASTER/DEAN, OR ANY OF ITS AUTHORIZED SERVICE CENTERS,
AND/OR THE PART BEING USED IS MODIFIED FROM ITS ORIGINAL CONFIGURATION, THIS
WARRANTY WILL BE VOID. FURTHER, FRYMASTER/DEAN AND ITS AFFILIATES WILL NOT BE
LIABLE FOR ANY CLAIMS, DAMAGES OR EXPENSES INCURRED BY THE CUSTOMER WHICH
ARISE DIRECTLY OR INDIRECTLY, IN WHOLE OR IN PART, DUE TO THE INSTALLATION OF
ANY MODIFIED PART AND/OR PART RECEIVED FROM AN UNAUTHORIZED SERVICE CENTER.
Decathlon Series Gas Fryers
Installation & Operation Manual
TABLE OF CONTENTS
Page #
1. INTRODUCTION 1-1
1.1 After Purchase 1-1
1.2 Ordering Parts 1-1
1.3 Service Information 1-1
1.4 Computer Information 1-1
1.5 Safety Information 1-2
1.6 Service Personnel 1-3
2. IMPORTANT INFORMATION 2-1
2.1 Receiving and Unpacking Equipment 2-1
2.2 General 2-1
2.3 Principles of Operation 2-2
2.4 Rating Plate 2-3
2.5 Pre-Installation 2-3
2.6 Air Supply and Ventilation 2-4
2.7 Equipment Installed at High Altitudes 2-5
3. INSTALLATION 3-1
3.1 Installing the Fryer 3-1
3.2 Leveling the Fryer (Fryers equipped with legs only) 3-1
3.3 Installing Casters and Legs 3-2
3.4 Gas Connections 3-3
3.5 Adjustments/Adaptation to Different Gases 3-6
3.6 Electrical Connections 3-8
4. FRYER OPERATIONS 4-1
4.1 Initial Start-up 4-1
4.2 Boil-Out Procedure 4-3
4.3 Final Preparation 4-5
Decathlon Series Gas Fryers
Installation & Operation Manual
TABLE OF CONTENTS (CONT.)
Page #
5. CONTROLLER OPERATING INSTRUCTIONS 5-1
5.1 Operating Instructions: Electronic Thermostat Controller 5-1
5.2 Electronic Thermostat Controller/Computer with Back-Up Thermostat 5-2
6. PREVENTATIVE MAINTENANCE 6-1
6.1 General 6-1
7. TROUBLESHOOTING 7-1
7.1 General 7-1
7.2 Pilot Burner Malfunction 7-1
7.3 Main Burner Malfunctions 7-2
7.4 Electronic Thermostat Calibration 7-3
FINDING YOUR WAY AROUND THE DEAN DECATHLON
Top Cap
Electronic Operating
Thermostat
Burners
Basket Hanger
Flue Cap
Frypot
1.5” Round Drains
Drain Valve Handle (Red) Oil Return Handle (Yellow) Drain Flush Handle (Blue)
Filter Unit
Drain Tubes
Drain Tubes
3” Round Drains (SCFD models)
DECATHLON SERIES GAS FRYERS (NON-CE)
CHAPTER 1: INTRODUCTION
1.1 After Purchase
In order to improve service, have the following chart filled in by the Dean Authorized Service Technician who installed this equipment.
Authorized Service Technician/FASC Address
Telephone/Fax Model Number Serial Number Gas Type
1.2 Ordering Parts
Customers may order parts directly from their local factory authorized service center. For this address and phone number, contact your factor y authorized service center or call the Dean Service Hotline phone number, 1-800-551-8633.
To speed up your order, provide the model number, serial number, gas type, part needed, item part number (if known), and quantity needed.
1.3 Service Information
Call the Dean Service Hotline, 1-800-551-8633, for the location of your nearest factory authorized service center. To assist you more efficientl y, always provide the service technician wit h the model number, gas type, serial number, and the nature of the problem.
1.4 Computer Information
This equipment has been tested and found to co mply with the limits for a Class A digital device, pursuant to Part 15 of the FCC rules. While this device is a verified Class A device, it has been shown to meet the Class B limits. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses and can radiate radio frequency energ y and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of the equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
1-1
DECATHLON SERIES GAS FRYERS (NON-CE)
CHAPTER 1: INTRODUCTION
1.4 Computer Information (cont.)
The user is cautioned that any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.
If necessary, the user should consult the dealer or an experienced radio and television technician for additional suggestions.
The user may find the following booklet prepared by the Federal Communications Commission helpful: "How to Identify and Resolve Radio-TV Interference Problems". This booklet is available from the U.S. Government Printing Office, Washington, DC 20402, Stock No. 004-000-00345-4.
1.5 Safety Information
Before attempting to operate your unit, read the instructions in this manual thoroughly.
Throughout this manual, you will find notations enclosed in double-bordered boxes similar to the ones below.
CAUTION
CAUTION boxes contain information about actions or conditions that may cause or result in a
malfunction of your system.
WARNING
WARNING boxes contain information about actions or conditions that may cause or result in damage to your system, and which may cause your system to malfunction.
DANGER
DANGER boxes contain information about actions or conditions that may cause or result in injury
to personnel, and which may cause damage to your system and/or cause your system to malfunction.
1-2
DECATHLON SERIES GAS FRYERS (NON-CE)
CHAPTER 1: INTRODUCTION
1.6 Service Personnel
1.6.1 Definitions
A. Qualified and/or Authorized Operating Personnel
1. Qualified/authorized operating personnel are those who have carefull y read the information in this manual and have familiarized themselves with the equipment functions, or have had previous experience with the operation of equipment covered in this manual.
B. Qualified Installation Personnel
1. Qualified installation personnel are individuals, firms, corporations, and/or companies,
which, either in person or through a representative, are engaged in and a re responsible for the installation of gas-fired appliances. Qualified personnel must be experienced in such work, be familiar with all gas precautions involved, and have complied with all requirements of applicable national and local codes.
C. Qualified Service Personnel
1. Qualified service personnel are those who are familiar with Dean equipment and have been authorized by Dean to perform service on Dean equipment. All authorized service personnel are required to be equipped with a complete set of service parts manuals and stock a minimum amount of parts for Dean equipment. A list of Dean Factory Authorized Service Centers (FASCs) was included with the fryer when shipped from the factory. Failure to use qualified service personnel will void the Dean warranty on your equipment.
1-3
THIS PAGE INTENTIONALLY LEFT BLANK.
DECATHLON SERIES GAS FRYERS (NON-CE)
CHAPTER 2: IMPORTANT INFORMATION
2.1 Receiving and Unpacking Equipment
A. Check that the container is upright. Use an outward prying motion - no hammering - to
remove the carton. Unpack the fr yer carefully and remove all accessories from the carton. Do not discard or misplace these, as they will be needed.
B. After unpacking, immediately check the equipment for visible signs of shipping damage. If
damage has occurred, contact the carrier and file the appropriate freight claims. Do not contact the factory. Shipping damage responsibility is between the carrier and the dealer.
If your equipment arrives damaged:
1. File claim for damages immediately, regardless of extent of damage.
2. Visible loss or damage: Be sure this is noted on the freight bill or express receipt and is signed by the person making the delivery.
3. Concealed loss or damage: If damage is unnoticed until equipment is unpacked, notify freight company or carrier immediatel y, and file a concealed damage clai m. This should be done within 15 days of date of delivery. Be sure to retain container and all packing materials for inspection.
2.2 General
NOTE: Dean Does Not Assume Responsibility for Damage or Loss Incurred in Transit.
C. Frying systems with built-in filtration: Take off the filter support brace and remove the
filter pan from the cabinet.
D. Decathlon four-battery systems: Casters are pre-installed on the frying system and the
carton is furnished with three unloading ramps. Remove the b races from t he front casters b y taking out the securing bolts. Carefully roll the unit down the ramps from the front (cooking side).
E. Remove all plastic skin from sides, front, and doors of the fryer(s). Failure to do this prior to
initial fryer operation will make it very difficult to remove later.
Qualified, licensed, and/or authorized installation or service personnel only (as defined in Section 1.6) should perform the following:
Installation and service on Dean equipment.
Conversion of this appliance from one gas type to another.
Failure to use qualified, licensed, and/or authorized installation or service personnel to install, convert to another gas type or otherwise servi ce this equipment will void the Dean warranty and may result in damage to the equipment or injury to personnel.
2-1
DECATHLON SERIES GAS FRYERS (NON-CE)
CHAPTER 2: IMPORTANT INFORMATION
2.2 General (cont.)
Where conflicts exist betw een instructions and information in this manual and local code or national codes, or regulations, installation and operation shall comply with the codes or regulations in force in the country in which the equipment is installed.
DANGER
Building codes prohibit a fryer with its open tank of hot oil/shortening from being
installed beside an open flame of any type, including those of broilers and ranges.
Upon arrival, inspect the fryer carefully for visible or concealed damage. (See Receiving and Unpacking Equipment in Section 2.1.)
2-2
Loading...
+ 28 hidden pages