Ditek DTK-UPS400, DTK-UPS800, DTK-UPS600 User Manual

Line Interactive UPS
400VA-800VA
www.diteksurgeprotection.com 1-800-753-2345
Inspection
The following items are inside the box:
UPS unit User manual USB cable Remove the UPS from its package and inspect it for damage that may have occurred during shipping. If any re-pack the unit and return it to the place of purchase.
Connect to Ut
Connect AC power cord to utility power. The UPS will begin charging the internal battery. For best results, allow the battery to charge for a minimum of 6 hours prior to initial use.
ility Power
damage is discovered,
Connect Computer/Ethernet
This UPS provides surge protection for a single Ethernet connection. Remove existing Ethernet cable from PC and insert into UPS “IN” connector. Using an additional Ethernet cable, insert into PC network adapter and UPS “OUT” connector.
Plug in Equipment
Plug your equipment to Battery Backup Outlets on the rear panel of the UPS. NOTE: Make sure that the UPS is powered on to protect all important devices from data loss during power failure. CAUTION: NEVER connect a laser printer or scanner to the battery backup outlets of UPS. The equipment may draw significantly power to overload the UPS.
Connect USB Cable and Install Software
Connect one end of the USB cable to PC and the other to the USB port at the rear of the UPS. Download the latest version of ViewPower USB software from https://www.diteksurgeprotection.com/ups-software.html to your hard drive. Follow on-screen instructions to complete the software installation.
Battery backup outlets
AC input
Fuse/Circuit breaker
 USB com. portEthernet surge protection
Operation
UPS
Mode
UPS Power on
AC Mode
Overload in AC mode
Battery Mode
Overload in battery mode
Displa
When AVR is functioning, icon will
flash every second.
When battery level is low, icon will flash.
y
LCD Description
icon will flash.
icon will flash.
When UPS is powered on, it will enter this mode for 4 seconds. LCD information will be displayed in the following order when LCD is touched.
1. Output voltage
2. Input voltage
3. Load level
4. Battery capacity When overload occurs,
alarm will beep every 0.5 second.
Alarm will beep every 10 seconds and LCD information will be displayed in the following order when LCD is touched.
1. Output voltage
2. Input voltage
3. Load level
4. Battery capacity When overload occurs, alarm will beep every 0.5 second.
NOTE: If backlight shuts off, you may activate it by touching the screen.
Fault Code Table:
Fault condition LCD Solutions Output short circuited Overload fault Disconnect all output loads and
Overcharge Call for service immediately.
Bad or severely discharged battery
High output voltage fault Over-temperature 1. Turn off the unit and wait for
If fault alarm occurs, please call for service immediately.
INT-100177-001 PN: 191-608 REV 01
Disconnect short-circuited loads and restart the UPS again.
restart the UPS again.
Please replace the battery.
Call for service immediately.
cooling.
2. Or remove excessive loads and wait for cooling.
Line Interactive UPS
400VA-800VA
SAVE THESE INSTRUCTION-This manual contains important instructions that should be followed
during installation and maintenance of the UPS and batteries.
www.diteksurgeprotection.com
1-800-753-2345
This UPS utilizes voltage that may be hazardous. Do not
attempt to disassemble the unit. The unit contains no user replaceable parts. Only factory service personnel may perform repairs.
This pluggable type A equipment with battery already installed
by the supplier is operator installable and may be operated by laymen.
The mains socket outlet that supplies the UPS shall be installed
near the UPS and shall be easily accessible.
During the installation of this equipment it should be assured
that the sum of the leakage currents of the UPS and the connected loads does not exceed 3.5mA.
Connection to any other type of receptacle other than a
two-pole, three-wire grounded receptacle may result in shock hazard as well as violate local electrical codes.
In the event of an emergency, press the "OFF" button and
disconnect the power cord from the AC power supply to properly disable the UPS.
Do not allow any liquids or any foreign object to enter the UPS.
Do not place beverages or any other liquid-containing vessels on or near the unit. This unit intended for installation in a controlled environment
(temperature controlled, indoor area free of conductive contaminants). Avoid installing the UPS in locations where there is standing or running water, or excessive humidity.
Do not plug the UPS input into its own output.Do not attach a power strip or surge suppressor to the UPS.Do not attach non-computer-related items, such as medical
equipment, life-support equipment, microwave ovens, or vacuum cleaners to UPS.
Problem Possible Cause Solutions
Nothing is displayed on LCD panel.
The UPS is always in battery mode.
The UPS continuously beeps.
Backup time too short.
If any abnormal situations occur that are not listed above, please call for service immediately.
The UPS is not on. Press the power switch
again to turn on the UPS.
Battery voltage is too low.
Battery fault. Replace the battery. Power cord loose. Re-plug the power cord.
Please check the fault
code for the details.
Battery voltage is too low.
Overload. Remove some unnecessary
Battery defect. Replace the battery.
Charge the battery at least 6 hours.
Please check the fault code for the details.
Charge the battery at least 6 hours.
loads. Before reconnecting equipment, please verify that the load matches the UPS capability specified in the specs.
Do not dispose of batteries in a fire as they may explode.A battery can present a risk of electrical shock and high short
circuit current. The following precautions should be observed when working on batteries:
1) Remove watches, rings, or other metal objects from the hands.
2) Use tools with insulated handles.
3) Wear rubber gloves and boots.
4) Do not lay tools or metal parts on top of batteries.
5) Disconnect charging source prior to connecting or disconnecting batteries terminal.
6) Remove battery grounds during installation and maintenance
to reduce likelihood of shock.
Internal battery voltage is 12VDC.Sealed, lead-acid, 6-cell
battery.
Servicing of batteries should be performed or supervised by
personnel knowledgeable of batteries and the required precautions. Keep unauthorized personnel away from batteries.
When replacing batteries, replace with the same number and
type of sealed lead-acid battery. Do not open or mutilate the battery or batteries. Released
electrolyte is harmful to the skin and eyes. It may be toxic.
Caution: Hazardous voltage could result in electric shock.
Although UPS power is disconnected, hazardous voltage still may be accessible through supply from battery. The battery supply should be therefore disconnected in the plus and minus pole at the connectors of the battery when maintenance or service work inside the UPS is necessary.
To reduce the risk of overheating the UPS, do not cover the
UPS' cooling vents and avoid exposing the unit to direct sunlight or installing the unit near heat emitting appliances such as space heater or furnaces.
Unplug the UPS prior to cleaning and do not use liquid or spray
detergent.
MODEL
CAPACITY Input Voltage Input Voltage Range Output Voltage
Regulation Transfer Time Waveform Battery Type & No Charging Time Dimension (DxWxH) Net Weight (kgs) Humidity Noise Level
*Specifications are subject to change without notice.
DTK-UPS400
400VA/240W 600VA/360W 800VA/480W
12V/4.5Ahx1 12V/7Ahx1 12V/9Ahx1
6 hours recover to 90% capacity
3.7 4.4 5
0-90% RH @ 0-40°C non-condensing)
DTK-UPS600 DTK-UPS800
110/120 VAC
81-145 VAC
± 10 % (Bat. mode)
Typical 2-6 ms
Simulated Sine Wave
300 x 101 x 142 mm
Less than 40dB
INT-100177-001 PN: 191-608 REV 01