DTK-RM12TLC
12-Channel Rack Mount Surge Protector
General Product Specifications
Power outages, surges, and voltage transients on data lines can be deadly to critical
data/comm equipment. DITEK’s DTK-RM12TLC 1U, rack mount pat c h panel/s u rge protector
is designed specifically to protect the Rauland-Borg Telecenter VI communications/safety
system. Mounted at the Telecenter system, the 12-channel DTK-RM12TLC protects
Telecenter VI Telco, Speaker, Clock, and Call circuits for up to twelve portable classrooms.
DTK-RM12TLC
Features
• Protects Telecenter VI runs from portable
classrooms to the control unit
• 12 RJ45 connected lines in a 1U height rackmount package
• SAD technology provides optimal circuit protection
• Single point ground improves protection and
speeds installation
Specifications
• Connection Method: 110 Punch Block/RJ45
(8-wire) In/Out
• Continuous Current: 0.5A Telco,
1.0A Speaker, Clock, Call In
• Max. Surge Current: 100A per line
(10/1000µs impulse)
• Protection Modes: All Lines – Ground
• Dimensions: 1.75”H x 19.0” W x 1.3”D
(45mm x 483mm x 33mm)
• Weight: 1.25 pounds (.57kg)
• Housing: Aluminum
• Warranty: Ten Year Limited Warranty
DTKRM12TLC
Telco
(Pins 4 & 5)
Speaker
(Pins 1 & 2)
Clock
(Pins 7 & 8)
Service
Voltage
48V 180V 250V
25V
25V
MCOV Clamping
45V 60V
Voltage
60V45V
Telecenter VI and Rauland-Borg areTMRauland-Borg Corporation
One DITEK Center
1720 Starkey Road
Largo, FL 33771
1-800-753-2345 Direct 1-727-812-5000
Technical Support: 1-888-472-6100
www.ditekcorp.com
Call In
(Pins 3 & 6)
12V
Doc. Number: SPS-100054-002 Rev 1 9/07
©2007 DITEK Corp.
Specification Subject to Change
20V 28V