Ditek DTK-ESS User Manual

INSTALLATION INSTRUCTIONS
DTK-ESS (Electric Switch Suppressor)
The Ditek DTK-ESS kit is intended for use on electrical switching devices that are connected through or that are actuated by a relay contact on access control panels. The DTK-ESS kit consists of 2 suppressors. 1- protects the control panel, the 2nd protects the relay contacts. Both protect against transients that are the result of the collapsing electrical field of an electromagnetic switching device. Like that of an electric door strike.
DTK-ESS
DTK-ESS
+
ELECTRICAL SWITCHING DEVICE
-
+
POWER SOURCE
12 OR 24 VOLTS
AC OR DC
TERMINAL STRIP
Each electrical switching device will require 1- suppressor to be installed across the relay contacts located at the control panel, and the 2nd suppressor to be installed across the leads of the switching device solenoid. The DTK-ESS is a bipolar device and can be installed without regard to polarity.
-
Diversified Technology Group, Inc.
1720 Starkey Road Largo, Florida 33771
Tel. 727-812-5000 Fax 727-812-5026
SCALE:
DATE:
6-24-99
DESCRIPTION: PART NO. REV.
INSTALLATION INSTRUCTION, DTK-ESS
MATERIAL:
FINISH:
DRAWN BY: RWMAPPROVED BY:
REVISED:
191398
DRAWING NUMBER
INT-100047-001
0
Loading...