Ditek DTK-DF120S1, Deflector Series User Manual

DTK-DF120S1
User Guide
DITEK CORPORATION
One DITEK Center 1720 Starkey Road Largo, Fl 33771 1-800-753-2345 www.diteksurgeprotection.com
MODULE
STATUS
ENERGIZED
DTK-DF120M
120VAC
C
US
U
R
DTK-DF120M (Surge Module)
GROUNDED
Surge Protection
GOOD
REPLACE
DEFLECTOR
Pat. www.diteksurgeprotection.com/patents
Model: DTK-DF120M SPD TYPE 2CA
Electrical Ratings: 120VAC, 20A, 50/60 Hz, Single Phase Nominal Discharge Current Rating: (In): 10kA, SCCR: 10kA MCOV Rating: 150 L-N, 150 L-G VPR: 600 L-N, 600 L-G Suitable for use on a circuit capable of delivering not more than 10,000 rms symmetrical amperes, 120 Volts maximum when pro­tected by a 20 ampere circuit breaker rated 120 volts minimum. Convient a des circuits produisant au plus 10,000 A e.
WARNING - SHOCK HAZARD - DO NOT OPEN
AVERTISSEMENT - RISQUE DE CHOC
Front
OUT TO CONNECTED
NEUTRAL
MODULE
STATUS
ENERGIZED
GROUNDED
GOOD
REPLACE
DITEK
MADE IN USA
NE PAS OUVRIR
EQUIPTMENT
EARTH
LINE
NO C NC
SERIES
R
Back
TB1
OUT
BUZ1
NC C NO
DITEK
Surge Protection
BUZZER SWITCH
B Y P A S S
R
POSITION
A B
N O R M A L
SW1
A B
TB2
IN
LINE IN 120V
EARTH NEUTRAL LINE
BUZZER SWITCH
POSITION
B Y P
A B
A S S
N O R M A L
SW1
A B
The DTK-DF120S1 is a series connected Surge Protective Device with a replaceable surge module.The LED indicators on the top face of the DTK-DF120M provide power, ground and surge module health status. When the DTK-DF120M surge module has gone end of life, the large “REPLACE” RED LED will illuminate and the “GOOD” LED will turn off. Also, the audible alarm will sound to provide an extra alert as to the surge module’s health. To silence the alarm, remove the dead module and replace it with a new, unused module. If a new module is not available, the alarm can be silenced by moving the toggle switch into the A, or BYPASS position. When a new DTK-DF120M surge module is available, this toggle switch must be moved to the B, or the NORMAL position before installing the new module. This action will also require the cover to be removed to gain access to this switch. The red polarizing keys insure that the correct voltage module will mate with its corresponding base. CAUTION: By removing the cover, you will be exposed to live metal parts and there is a risk of electrocution.
WARNING: Removing the cover should only be performed by a licensed electrician. WARNING: When the DTK-120M module has gone end of life, or is missing, the base is susceptible to damage from surge energy. Make sure you always have a spare module available. No substitutions shall be permitted.