DITEC VALOR Technical Manual

Ditec VALOR
Sliding doors automation
(Original instructions)
IP1950 EN
Technical manual
www.ditecentrematic.com
IP1950EN - 2013-09-13
Index
Subject Page
1. General safety precautions 3
2. Declaration of incorporation of partly completed machinery 4
2.1 Machinery directive 4
3. Technical data 5
3.1 Applications 5
4. Standard installation 6
5. Installation of the automation 7
5.1 VALOR box fastening 7
5.2 VALOR T box fastening 8
5.3 VALOR H box fastening 9
5.4 Preparation of glass door wing 11
5.5 VALOR - VALOR H door wing installation and adjustment 12
5.6 VALOR T door wing installation and adjustment 13
5.7 Floor guide installation 15
5.8 Belt adjustment 16
5.9 Lock installation 16
6. Electrical connections 17
7. Ordinary maintenance program 18 User instructions 19
General safety precautions 19 Manual release instruction 21 Function selector user instructions 22
Key
This symbol indicates useful information for the correct functioning of the product.
This symbol indicates instructions or notes regarding safety, to which special atten­tion must be paid.
i
IP1950EN - 2013-09-13
1. General safety precautions
This installation manual is intended for qualified personnel only. Installation, electrical connections and adjustments must be performed in accordance with Good Working Methods and in compliance with the present standards. Read the instructions carefully before installing the product. Bad installation could be dangerous.
The packaging materials (plastic, polystyrene, etc.) should not be discarded in the environ-
ment or left within reach of children, as these are a potential source of danger. Before installing the product, make sure it is in perfect condition. Do not install the product in explosive areas and atmospheres: the presence of inflammable gas or fumes represents a serious safety hazard. Before installing the motorisation device, make all the necessary structural modifications in order to create safety clearance and to guard or isolate all the crushing, shearing, trapping and general hazardous areas. Make sure the existing structure is up to standard in terms of strength and stability. The mo­torisation device manufacturer is not responsible for failure to observe Good Working Methods when building the frames to be motorised or for any deformation during use.
The safety devices (photocells, safety edges, emergency stops, etc.) must be installed
taking into account: applicable laws and directives, Good Working Methods, installation premises, system operating logic and the forces developed by the motorised door. The safety devices must protect the crushing, cutting, trapping and general hazardous areas of the motorised door. Display the signs required by law to identify hazardous areas. Each installation must bear a visible indication of the data identifying the motorised door. When requested, connect the motorised door to an effective earthing system that complies with current safety standards. During installation, maintenance and repair operations, cut off the power supply before opening the cover to access the electrical parts. The automation protection casing must be removed by qualified personnel only.
The electronic parts must be handled using earthed antistatic conductive arms.
The manufacturer of the motorisation declines all responsibility in the event of component
parts being fitted that are not compatible with the safe and correct operation. Use original spare parts only for repairs or replacements of products. The installer must supply all information on automatic, manual and emergency operation of the motorised door and must provide the user with the operating instructions.
Failure to observe the information in this manual may result
in minor personal injury or damage to equipment.
Save these instructions for future reference.
IP1950EN - 2013-09-13
2. Declaration of incorporation of partly com­pleted machinery
2.1 Machinery Directive
(Directive 2006/42/EC, Annex II-B) The manufacturer Entrematic Group AB with headquarters in Lodjursgatan 10, SE-261 44 Landskrona, Sweden declares that the automation system for Ditec VALOR sliding doors:
- has been constructed to be installed on a manual door to construct a machine pursu-
ant to the Directive 2006/42/EC. The manufacturer of the motorized door shall declare conformity pursuant to the Directive 2006/42/EC (annex II-A), prior to the machine being put into service;
- conforms to applicable essential safety requirements indicated in annex I, chapter 1 of
the Directive 2006/42/EC;
- conforms to the Low Voltage Directive 2006/95/EC;
- conforms to the Electromagnetic Compatibility Directive 2004/108/EC;
- technical documentation conforms to Annex VII-B to the Directive 2006/42/EC;
- technical documentation is managed by Marco Pietro Zini with offices in Via Mons. Banfi,
3 - 21042 Caronno Pertusella (VA) - ITALY;
- a copy of technical documentation will be provided to national competent authorities,
following a suitably justified request.
Landskrona, 15-01-2013 Marco Pietro Zini (President)
Pursuant to Machinery Directive (2006/42/EC) the installer who motorizes a door or gate has the same obligations as the manufacturer of machinery and as such must:
- prepare the technical file which must contain the documents indicated in Annex V of the
Machinery Directive;
(The technical file must be kept and placed at the disposal of competent national authori-
ties for at least ten years from the date of manufacture of the motorized door);
- draw up the EC Declaration of Conformity in accordance with Annex II-A of the Machinery
Directive and deliver it to the customer;
- affix the EC marking on the motorized door in accordance with point 1.7.3 of Annex I of
the Machinery Directive.
IP1950EN - 2013-09-13
Service class: 5 (minimum 5 years of working life with 600 cycles per day). Applications: VERY INTENSE (for shared entrances with very intense pedestrian use).
Service class: 6 (minimum 5 years of working life with continuous use). Applications: CONTINUOUS (for all special situations with continuous use).
- Performance characteristics are to be understood as referring to the recommended weight (approx. 2/3 of maximum permissible weight). A reduction in performance is to be expected when the access is made to operate at the maximum permissible weight.
- Service class, running times, and the number of consecutive cycles are to be taken as merely indicative having been statistically determined under average operating conditions, and are therefore not necessarily applicable to specific conditions of use. During given time spans product performance characteristics will be such as not to require any special maintenance.
- The actual performance characteristics of each automatic access may be affected by independ­ent variables such as friction, balancing and environmental factors, all of which may substan­tially alter the performance characteristics of the automatic access or curtail its working life or parts thereof (including the automatic devices themselves). When setting up, specific local conditions must be duly borne in mind and the installation adapted accordingly for ensuring maximum durability and trouble-free operation.
3. Technical data
Ditec VALOR L-H Ditec VALOR P Ditec VALOR N Ditec VALOR T
Power supply 230 V~ 50/60 Hz 230 V~ 50/60 Hz 230 V~ 50/60 Hz 230 V~ 50/60 Hz
Power fuse F1A
F1A F1,6A with weight >200 kg
F1A F1,6A with weight >200 kg
F1A F1,6 A with weight >200 kg
Rated power input 200 W 300 W 300 W 300 W Max speed 1 wing 0,8 m/s 0,8 m/s 0,8 m/s - Max speed 2 wings
1,6 m/s
1,6 m/s 1,2 m/s with weight 180 kg
1,6 m/s 1,2 m/s with weight 180 kg
0,8 m/s
Max speed 4 wings - - - 1,6 m/s Service life 5 - HEAVY DUTY 6 - CONTINUOUS 6 - CONTINUOUS 6 - CONTINUOUS Intermittence S3 =100% S3=10 0% S3=100% S3=100% Max door weight 1 wing
100 kg
120 kg 100 kg 1 break­out door wing
120 kg 200 kg
Max door weight 2 wings
180 kg
220 kg 180 kg 2 break­out door wings
240 kg 260 kg
Door weight with reinfor­ced wheels 1 wing
- - 150 kg -
Door weight with reinfor­ced wheels 2 wings
- - 300 kg -
Temperature -20 °C - +55 °C -20 °C - +55 °C -20 °C - +55 °C -20 °C - +55 °C Temperature with
batteries
-10 °C - +50 °C -10 °C - +50 °C -10 °C - +50 °C -10 °C - +50 °C
Degree of protection IP20
(FOR INTERNAL USE ONLY)
IP20 (FOR INTERNAL USE ONLY)
IP20 (FOR INTERNAL USE ONLY)
IP20 (FOR INTERNAL USE ONLY)
Control panel EL20 EL20 EL20 EL20 Accessories power
supply
24 V
0,5 A 24 V 0,5 A 24 V 0,5 A 24 V 0,5 A
3.1 Operating instructions
IP1950EN - 2013-09-13
4. Standard installation
Ref. Code Description
0 VALOR Operator 1 Drive unit 2 EL20 Control panel 3 AL2 Transformer 4 VALABE
VALABC
Emergency batteries (optional) No-break batteries (optional)
5
PAS024AMW (microwave+infrared), or PASAA2 (only infrared)
Combined sensor for opening and safety during closing external side
6A
PAS024AMW (microwave+infrared), or PASAA2 (infrared only)
Combined sensor for opening and safety during closing internal side (operator)
or
6B
PASM24W (microwave), or PASM243 (microwave), or PASS24 (microwave), or PASS24W (microwave), or PASA (infrared)
}
+ PASAT 3I (infrared)
Opening sensor (a) + Safety during closing sensor (b) inter­nal side (inside the operator’s housing)
7
PASAT3 PASAT3I
Safety during opening sensor (outside or inside the opera­tor’s housing)
8 VALSB
LOKSBM
Integrated release handle Release handle
9 COME - COMHK Functions selector switch
10 CELPR Photocells (NOT ACCORDING TO STANDARD EN 16005)
11 MD1 Display
12 PFP1 - PFP2 - PDP1 - PDP2 Open push buttons
A Connect the power supply to an approved omnipolar switch with an opening distance of the contacts of at least
3mm (not supplied). The connection to the mains must be made via an independent channel, separated from the connections to command and safety devices.
A
11
3
1
2
4
6A
6B
7
0
8
9
10
12
7
GND
5
a
b
6B
IP1950EN - 2013-09-13
i
The given operating and performance features can only be guaranteed with the use of DITEC accessories and safety devices.
5. Installation of the automation
5.1 VALOR box fastening
70 max
0KP515AB
+/- 8
+/- 6
175
80
90
38
2728H
10 HM = H + 18
145
Unless otherwise specified, all measurements are expressed in millimetres (mm). The VALOR automation wall fixing measurements are illustrated in the diagram, considering that the door wing profiles are not of our production. If the door wings are made with DITEC profiles of the PAM series: refer to the measurements in the related manuals. WARNING: if the door wings are fitted with a break-out device, use the carriages with brackets with 3 fixing points. Fix the box with M6 Ø12 steel plugs or 6MA screws. Distribute the fixing points approx. every 800 mm. Make sure that the box is level and its top surface is perpendicular with the floor and not deformed lengthwise with the shape of the wall. If the wall is not straight and smooth, the box must be fixed to metal plates. WARNING: The fastening of the box to the wall must be suitable in order to sustain the weight of the door wings.
Wiring passage
IP1950EN - 2013-09-13
5.2 VALOR T box fastening
KPAM45
KPAM45
255
160
70 max 70 max
90
38
2728
H
12
145
+/- 8
HM=H+16
+/- 6 +/- 6
Unless otherwise specified, all measurements are expressed in millimetres (mm). The figure shows the measurements for wall mounting the VALOR H automation considering that the door wings are made of DITEC PAMH60 series profiles. If the PAMH60 door wing has lead-shielding (e.g. radiology department) refer to the measure­ments marked [*]. Fix the box with M6 Ø12 steel plugs or 6MA screws. Distribute the fixing points approx. every 800 mm. Make sure that the box is level and its top surface is perpendicular with the floor and not deformed lengthwise with the shape of the wall. If the wall is not straight and smooth, the box must be fixed to metal plates. WARNING: The fastening of the box to the wall must be suitable in order to sustain the weight of the door wings.
Wiring passage
Loading...