2.Declaration of incorporation of partly completed machinery22
2.1 Machinery Directive22
2.2 Operating instructions22
3.Technical specifications23
4.Standard installation24
5.Dimensions and references25
6.Installation26
6.1 Preliminary checks26
6.2 Bracket fastening27
6.3 Geared motor installation28
6.4 Reversible and irreversible piston29
7.Electrical connections30
8.Ordinary maintenance program30
User instructions31
Manual release instruction32
Caption
This symbol indicates instructions or notes regarding safet y, to which special attention must be paid.
This symbol indicates useful information for the correct functioning of the product.
IP2128EN - 2014-02-17
20
Page 3
1. General safety precautions
This installation manual is intended for qualified personnel only.
Installation, electrical connections and adjustments must be performed in accordance with Good Working Methods and in compliance with the present standards.
Read the instructions carefully before installing the product.
Bad installation could be dangerous.
The packaging materials (plastic, polystyrene, etc.) should not be discarded in
the environment or left within reach of children, as these are a potential source
of danger.
Before installing the product, make sure it is in perfect condition.
Do not install the product in explosive areas and atmospheres: the presence of inflammable gas or fumes represents a serious safety hazard.
Before installing the motorisation device, make all the necessar y structural modifications in order to create safety clearance and to guard or isolate all the crushing,
shearing, trapping and general hazardous areas.
Make sure the existing structure is up to standard in terms of strength and stability.
The motorisation device manufacturer is not responsible for failure to observe Good
Working Methods when building the frames to be motorised or for any deformation
during use.
The safety devices (photocells, safety edges, emergency stops, etc.) must be
installed taking into account: applicable laws and directives, Good Working
Methods, installation premises, system operating logic and the forces developed by
the motorised door.
The safety devices must protect the crushing, cutting, trapping and general hazardous
areas of the motorised door.
Display the signs required by law to identify hazardous areas.
Each installation must bear a visible indication of the data identifying the motorised
door.
When requested, connect the motorised door to an effective earthing system that
complies with current safety standards.
During installation, maintenance and repair operations, cut off the power supply before
opening the cover to access the electrical parts.
The automation protection casing must be removed by qualified personnel only.
The electronic parts must be handled using earthed antistatic conductive arms.
The manufacturer of the motorisation declines all responsibility in the event of component parts being fitted that are not compatible with the safe and correct operation.
Use original spare parts only for repairs or replacements of products.
The installer must supply all information on automatic, manual and emergency operation of the motorised door and must provide the user with the operating instructions.
IP2128EN - 2014-02-17
21
Page 4
2. Declaration of incorporation of partly
completed machinery
(Directive 2006/42/EC, Annex II-B)
The manufacturer Entrematic Group AB with headquarters in Lodjursgatan 10, SE-261 44 Landskrona, Sweden, declares that the automation for Ditec LUXO type swing gate:
- has been constructed to be installed on a manual door to construct a machine pursuant to the
Directive 2006/42/EC. The manufacturer of the motorised door shall declare conformity pursuant to the Directive 2006/42/EC (Annex II-A), prior to the machine being put into service;
- conforms to the applicable essential safety requirements indicated in ANNEX I, Chapter 1 of the
Directive 2006/42/EC;
- conforms to the Low Voltage Directive 2006/95/EC;
- conforms to the Electromagnetic Compatibility Directive 2004/108/EC:
- the technical documentation conforms to Annex VII-B of the Directive 2006/42/EC;
- the technical documentation is managed by Marco Pietro Zini with headquarters in Via Mons.
Banfi, 3 - 21042 Caronno Pertusella (VA) - ITALY;
- a copy of technical documentation will be provided to national competent authorities, following
a suitably justified request.
Land skro na, 06-05-2013 Marco Pietro Zini (President)
2.1 Machinery Directive
Pursuant to Machinery Directive (2006/42/EC) the installer who motorises a door or gate has the
same obligations as the manufacturer of machinery and as such must:
- prepare the technical file which must contain the documents indicated in Annex V of the Machinery
Directive;
(The technical file must be kept and placed at the disposal of competent national authorities for
at least ten years from the date of manufacture of the motorised door);
- draw up the EC Declaration of Conformity in accordance with Annex II-A of the Machinery Direc-
tive and deliver it to the customer;
- affix the EC marking on the motorised door in accordance with point 1.7.3 of Annex I of the
Machine Directive.
2.2 Operating instructions
Service class: 4 (minimum 100 cycles a day for 10 years or 200 cycles a day for 5 years)
Use: INTENSIVE (For vehicle or pedestrian accesses to large condominiums, industrial or
commercial complexes and parking lots with very frequent use).
- Performance characteristics are to be understood as referring to the recommended weight
(approx. 2/3 of maximum permissible weight). When used with the maximum permissible
weight a reduction in the above mentioned performance can be expected.
- Service class, running times, and the number of consecutive cycles are to be taken as merely
indicative Having been statistically determined under average operating conditions, and are
therefore not necessarily applicable to specifi c conditions of use.
- Each automatic entrance has variable elements such as: friction, balancing and environmental
factors, all of which may substantially alter the performance characteristics of the automatic
entrance or curtail its working life or parts thereof (including the automatic devices themselves).
The installer should adopt suitable safety conditions for each particular installation.
22
IP2128EN - 2014-02-17
Page 5
3. Technical specifications
3
3
LUXO3BHLUXO4BH
Power supply24 V
24 V24 V
Absorption4 A4 A12 A
Thrust2000 N2000 N3000 N
Max run350 mm500 mm500 mm
Opening time20÷50 s / 90°30÷60 s / 90°20÷45 s / 90°
Service class4 - INTENSIVE4 - INTENSIVE4 - INTENSIVE
Intermittence
S2 = 20 min
S3 = 50%
S2 = 20 min
S3 = 50%
Temperaturemin -20° C max +55° Cmin -20° C max +55° Cmin -20° C max +55° C
Degree of protectionIP24DIP24DIP24D
Control panelE2HLX - VIVAHE2HLX - VIVAHVIVAH
Applications
m = leaf width
kg = leaf weight
Limit
dimensions
Recommended
dimensions
500 kg
400 kg
300 kg
200 kg
100 kg
4 5
500 kg
400 kg
300 kg
200 kg
100 kg
m 1 2
4 5
m 1 2
LUXO3BLUXO5B
Power supply230 V~ 50 Hz230 V~ 50 Hz
Absorption1.1 A1.1 A
Thrust3000 N3000 N
Max run350 mm500 mm
Opening time22 s / 90°32 s / 90°
Service class4 - INTENSIVE4 - INTENSIVE
Intermittence
S2 = 20 min
S3 = 50%
S2 = 20 min
S3 = 50%
Temperaturemin -20° C max +55° Cmin -20° C max +55° C
Degree of protectionIP24DIP24D
Control panelE2 - LOGICME2 - LOGICM
Applications
m = leaf width
kg = leaf weight
Limit
dimensions
Recommended
dimensions
500 kg
400 kg
300 kg
200 kg
100 kg
500 kg
400 kg
300 kg
200 kg
100 kg
m12345
m1 2 3 4 5
LUXO5BH
LUXO5VBH
S2 = 20 min
S3 = 50%
500 kg
400 kg
300 kg
200 kg
100 kg
m1 2 3 4 5
IP2128EN - 2014-02-17
23
Page 6
4. Standard installation
TX - 4x0.5 mm²
TX - 4x0.5 mm²
RX - 4x0.5 mm²
RX - 4x0.5 mm²
4x0.5 mm²
3x1.5 mm²
1
7
7
3
8
A
5
2x1.5 mm²
7
7
4
2x1.5 mm²
5
66
2
Ref.CodeDescription
1GOL4Transmitter
2LAMPHFlashing light
XEL5
3
GOL4M
4LAB9Magnetic loop detection device for traffic monitoring
LUXO3BAC reversible and irreversible actuator for door wing of up to 3.5 m
LUXO3BHDC irreversible actuator for door wing of up to 3.5 m
LUXO4BHDC irreversible actuator for door wing of up to 4 m
5
LUXO5BAC reversible and irreversible actuator for door wing of up to 5 m
LUXO5BHDC irreversible actuator for door wing of up to 5 m
LUXO5VBHDC irreversible actuator for door wing of up to 5 m with limit switch
LUXO3B
LUXO5B
LUXO3BH
6
LUXO4BH
LUXO5BH
LUXO5VBH
XEL2
7
LAB4
8Control panel
A
Key selector
Codified via radio control keyboard
Cable 4x1,5 mm²
Cable 2x1,5 mm²
Photocells
Photocells IP55
Connect the power supply to an approved omnipolar switch with an opening distance
of the contacts of at least 3mm (not supplied).
The connection to the mains must be made via an independent channel, separated
from the connections to command and safety devices.
IP2128EN - 2014-02-17
24
Page 7
5. Dimensions and references
120
100
LUXO3B-5B
9
10
F
G
12
16
11
13
Ref.CodeDescription
9Cover
10Lock flap
11Release lock
12Drive screw cover
13Drive screw
14Tail bracket
15Head bracket
16LUXOFCHLimit switch (only standard on LUXO5VBH)
The given operating and performance features can only be guaranteed with the use of ENTREMATIC
accessories and safety devices.
Unless otherwise specified, all measurements are expressed in mm.
6.1 Preliminary checks
Check that the structure is sufficiently rugged and that the hinge pivots are properly lubricated.
Provide an opening and closing stop.
Position tail bracket [14] on to the pillar to check installation measurements and secure it.
The installation measurements indicated in the table allow you to choose the values of [A] and [B] on
the basis of the desired opening angle and in relation to the on site spaces and overall dimensions.
NOTE: The measurements [A] and [B] must be the same, in order to have a regular moviment.
Increasing [A] decreases the coming up speed during opening.
Reducing [B] increases the extent of gate opening.
Measurements [A] and [B] must in any case be compatible with the useful travel of the piston so
that; if [A] is increased, [B] must be decreased and vice versa.
[*] Use measurements between minimum and maximum values
- Once you have fastened the tail bracket [14] following the measurements indicated on page
26, fasten the head bracket [15] to the gate.
NOTE: shorten the tail bracket [14] by following the instructions on page 26.
- When the gate is completely closed, place the head bracket [15] near the piston attachment
complying with measurements [E] and [L]. Make sure that the head brackets [15] and tail
brackets [14] are perfectly level as shown in the following figures and fasten the head bracket
[15] to the gate.
LUXO3BH
Ø9
50
72
14
70
32
152
15
100
Ø14
82 (B - C)
112 (B - C)
142 (B - C)
L
LUXO3B-LUXO4BH-LUXO5B-LUXO5BH-LUXO5VBH
Ø18
70
38
112
Ø9
90
90
B - C
90
Ø9
80
115
15
Ø14
5010
IP2128EN - 2014-02-17
180
165
80
50
31 (*42)
10
E
90
Ø9
115
20
115
Ø18 (*22)
135
14
6
60
14
15
L
15
6
60
* LUXO5VBH
27
Page 10
6.3 Geared motor installation
14
12
15
13
13
- Open the lock flap [10] unscrew the screw [F] and remove the cover [9]. Unscrew the screw
[G] and remove the drive screw cover [12] as shown in the figure on pag. 7. Release the piston
(see OPERATING INSTRUCTIONS).
- Mount the piston on tail [14] and head bracket [15], tightly screwing down the self-locking nut
and lubricate the turning points.
NOTE: pay special attention to the correct assembly of the washer on the head bracket.
LUXO3BHLUXO3B
LUXO4BH
LUXO5B
LUXO5BH
14
- Fit and secure the drive screw cover [12] on the drive screw [13] by means of the screws provided
[G]. NOTE: ensure that the drive screw [13] is properly inserted onto the screw cover head [12]
(see figure).
- Move the gate by hand and check for smooth and free movement throughout.
LUXO5VBH
LUXO3BH
LUXO3B
LUXO4BH
LUXO5B
LUXO5BH
LUXO5VBH
13
28
IP2128EN - 2014-02-17
Page 11
6.4 Reversible and irreversible piston (only LUXO5BH and LUXO5VBH)
To make the piston reversible, insert pin [M].
NOTE: the operation must be carried out with the piston moving.
Removing the pin [M], the piston becomes irreversible, and the release can only be made with the
key (see OPERATING INSTRUCTIONS).
M
M
IP2128EN - 2014-02-17
29
Page 12
7. Electrical connections
i
Before connecting the power supply, make sure the plate data correspond to that of the mains
power supply.
An omnipolar disconnection switch with minimum contact gaps of 3 mm must be included in the
mains supply.
Check that upstream of the electrical installation there is an adequate residual current circuit
breaker and a suitable overcurrent cutout.
The gearmotors LUXO3B and LUXO5B can be connected to the E2 and LOGICM control panels.
The gearmotors LUXO3BH and LUXO4BH can be connected to the E2HLX and VIVAH control panels.
The gearmotors LUXO5BH and LUXO5VBH can be connected to the VIVAH control panel.
The electrical wiring and the start-up of the gearmotors LUXO are shown in figure and in the
installation manuals of the E2, LOGICM, E2HLX and VIVAH control panels.
To increase the protection of the motor cable, a flexible Ø16 raceway [N] may be used and the associated Ø20 union [P], not supplied by us.
Tighten the screw [F].
8 . Routine maintenance plan
Perform the following operations and checks every 6 months according to intensity of use of the
automation.
Disconnect the 230 V~ power supply and batteries if present:
- Clean and lubricate, using neutral grease, the turning pins, the hinges of the gate and the drive
screw
- Check that fastening points are properly tightened.
- Check the electrical wiring is in good condition.
Reconnect the 230 V~ power supply and batteries if present:
- Check the power adjustments.
- Check the good operation of all command and safety functions (photocells).
- Check the good operation of the release.
- If present, check for battery continuity by powering off and performing several manoeuvres in
sequence. Upon test completion, power back on (230 V~).
NOTE: For spare parts, see the spares price list.
IP2128EN - 2014-02-17
30
Page 13
Operating instructions
General safety precautions
These precautions are an integral and essential part of the product and must be supplied to the user.
Read them carefully since they contain important information on safe installation, use
and maintenance.
These instructions must be kept and forwarded to all possible future users of the system.
This product must only be used for the specific purpose for which it was designed.
Any other use is to be considered improper and therefore dangerous. The manufacturer cannot be held responsible for any damage caused by improper, incorrect or unreasonable use.
This pr oduct must not be used by people (including children) with reduced physical, sensorial or
mental abilities, or lack of experience or knowledge, unless they are given proper surveillance
and instructions for operating the device by a person responsible for their safety.
Avoid operating in the proximity of the hinges or moving mechanical parts.
Do not enter within the operating range of the motorised door while it is moving.
Do not block the movement of the motorised door since this may be dangerous.
Do not allow children to play or stay within the operating range of the motorised door.
DETACH AND DELIVER TO THE CUSTOMER
Keep remote controls and/or any other control devices out of the reach of children in order to
avoid possible involuntary activation of the motorised door.
In the event of a fault or a malfunction of the product, turn off the power supply switch, do not
attempt to repair or intervene directly and contact only qualified personnel.
Failure to comply with the above may cause a dangerous situation.
All cleaning, maintenance or repair work must be carried out by qualified personnel.
To ensure that the system works efficiently and correctly, the manufacturer’s indications must
be complied with and only qualified personnel must see to the routine maintenance of the
motorised gate.
In particular, regular checks are recommended in order to verify that the safety devices are
operating correctly.
All installation, maintenance and repair work must be documented and made available to the
us e r.
To dispose of electrical and electronic equipment as well as batteries correctly,
users must take them to special “recycling centres” provided by the municipal
authorities.
IP2128EN - 2014-02-17
31
Page 14
Manual release instructions
In the event of a fault or blackout, insert
the key and turn it clockwise.
Unlock the electric lock, if mounted.
Manually slide the gate open.
To relock the wings, turn the key anticlockwise.
WARNING: the door wing block
and release operations must be
performed with the motor idle.
For any problems and/or information, contact the support service.
Installer's stampOperator
Date of intervention
Technician's signature
Intervention performed
Entrematic Group AB
Lodjursgatan 10
SE-261 44, Landskrona
Sweden
www.ditecentrematic.com
Customer's signature
32
DETACH AND DELIVER TO THE CUSTOMER
IP2128EN - 2014-02-17
Page 15
All the rights concerning this material are the exclusive property of Entrematic Group AB.
Although the content s of this public ation have been drawn up with the greates t care, Entrematic Group AB
cannot be held responsible in any way for any damage caused by mistakes or omis sions in this publication.
We reserve the right to make changes without prior notice.
Copying, scanning and changing in any way are expressly forbidden unless authorised in writing by Entrematic
Group AB.
IP2128EN - 2014-02-17
33
Page 16
IP2128EN - 2014-02-17
Entrematic Group AB
Lodjursgatan 10
SE-261 44, Landskrona
Sweden
www.ditecentrematic.com
Loading...