3. Technical specifications 23
4. Standard installation 24
5. Dimensions and references 25
6. Installation 26
6.1 Preliminary checks 26
6.2 Bracket fastening 27
6.3 Geared motor installation 28
6.4 Reversible and irreversible piston 29
7. Electrical connections 30
8. Ordinary maintenance program 30
User instructions 31
Manual release instruction 32
Caption
This symbol indicates instructions or notes regarding safet y, to which special atten­tion must be paid.
This symbol indicates useful information for the correct functioning of the product.
IP2128EN - 2014-02-17
20
1. General safety precautions
This installation manual is intended for qualified personnel only.
Installation, electrical connections and adjustments must be performed in ac­cordance with Good Working Methods and in compliance with the present standards. Read the instructions carefully before installing the product. Bad installation could be dangerous.
The packaging materials (plastic, polystyrene, etc.) should not be discarded in
the environment or left within reach of children, as these are a potential source of danger. Before installing the product, make sure it is in perfect condition. Do not install the product in explosive areas and atmospheres: the presence of inflam­mable gas or fumes represents a serious safety hazard. Before installing the motorisation device, make all the necessar y structural modi­fications in order to create safety clearance and to guard or isolate all the crushing, shearing, trapping and general hazardous areas. Make sure the existing structure is up to standard in terms of strength and stability. The motorisation device manufacturer is not responsible for failure to observe Good Working Methods when building the frames to be motorised or for any deformation during use.
The safety devices (photocells, safety edges, emergency stops, etc.) must be
installed taking into account: applicable laws and directives, Good Working Methods, installation premises, system operating logic and the forces developed by the motorised door. The safety devices must protect the crushing, cutting, trapping and general hazardous areas of the motorised door. Display the signs required by law to identify hazardous areas. Each installation must bear a visible indication of the data identifying the motorised door. When requested, connect the motorised door to an effective earthing system that complies with current safety standards. During installation, maintenance and repair operations, cut off the power supply before opening the cover to access the electrical parts.
The automation protection casing must be removed by qualified personnel only.
The electronic parts must be handled using earthed antistatic conductive arms. The manufacturer of the motorisation declines all responsibility in the event of com­ponent parts being fitted that are not compatible with the safe and correct operation. Use original spare parts only for repairs or replacements of products. The installer must supply all information on automatic, manual and emergency opera­tion of the motorised door and must provide the user with the operating instructions.
IP2128EN - 2014-02-17
21
2. Declaration of incorporation of partly completed machinery
(Directive 2006/42/EC, Annex II-B) The manufacturer Entrematic Group AB with headquarters in Lodjursgatan 10, SE-261 44 Land­skrona, Sweden, declares that the automation for Ditec LUXO type swing gate:
- has been constructed to be installed on a manual door to construct a machine pursuant to the
Directive 2006/42/EC. The manufacturer of the motorised door shall declare conformity pursu­ant to the Directive 2006/42/EC (Annex II-A), prior to the machine being put into service;
- conforms to the applicable essential safety requirements indicated in ANNEX I, Chapter 1 of the
Directive 2006/42/EC;
- conforms to the Low Voltage Directive 2006/95/EC;
- conforms to the Electromagnetic Compatibility Directive 2004/108/EC:
- the technical documentation conforms to Annex VII-B of the Directive 2006/42/EC;
- the technical documentation is managed by Marco Pietro Zini with headquarters in Via Mons.
Banfi, 3 - 21042 Caronno Pertusella (VA) - ITALY;
- a copy of technical documentation will be provided to national competent authorities, following
a suitably justified request.
Land skro na, 06-05-2013 Marco Pietro Zini (President)
2.1 Machinery Directive
Pursuant to Machinery Directive (2006/42/EC) the installer who motorises a door or gate has the same obligations as the manufacturer of machinery and as such must:
- prepare the technical file which must contain the documents indicated in Annex V of the Machinery
Directive;
(The technical file must be kept and placed at the disposal of competent national authorities for
at least ten years from the date of manufacture of the motorised door);
- draw up the EC Declaration of Conformity in accordance with Annex II-A of the Machinery Direc-
tive and deliver it to the customer;
- affix the EC marking on the motorised door in accordance with point 1.7.3 of Annex I of the
Machine Directive.
2.2 Operating instructions
Service class: 4 (minimum 100 cycles a day for 10 years or 200 cycles a day for 5 years) Use: INTENSIVE (For vehicle or pedestrian accesses to large condominiums, industrial or commercial complexes and parking lots with very frequent use).
- Performance characteristics are to be understood as referring to the recommended weight
(approx. 2/3 of maximum permissible weight). When used with the maximum permissible weight a reduction in the above mentioned performance can be expected.
- Service class, running times, and the number of consecutive cycles are to be taken as merely
indicative Having been statistically determined under average operating conditions, and are therefore not necessarily applicable to specifi c conditions of use.
- Each automatic entrance has variable elements such as: friction, balancing and environmental
factors, all of which may substantially alter the performance characteristics of the automatic entrance or curtail its working life or parts thereof (including the automatic devices themselves). The installer should adopt suitable safety conditions for each particular installation.
22
IP2128EN - 2014-02-17
3. Technical specifications
3
3
LUXO3BH LUXO4BH
Power supply 24 V
24 V 24 V
Absorption 4 A 4 A 12 A Thrust 2000 N 2000 N 3000 N Max run 350 mm 500 mm 500 mm Opening time 20÷50 s / 90° 30÷60 s / 90° 20÷45 s / 90° Service class 4 - INTENSIVE 4 - INTENSIVE 4 - INTENSIVE
Intermittence
S2 = 20 min S3 = 50%
S2 = 20 min S3 = 50%
Temperature min -20° C max +55° C min -20° C max +55° C min -20° C max +55° C Degree of protection IP24D IP24D IP24D Control panel E2HLX - VIVAH E2HLX - VIVAH VIVAH
Applications
m = leaf width kg = leaf weight
Limit dimensions
Recommended
dimensions
500 kg
400 kg
300 kg
200 kg
100 kg
4 5
500 kg
400 kg
300 kg
200 kg
100 kg
m 1 2
4 5
m 1 2
LUXO3B LUXO5B
Power supply 230 V~ 50 Hz 230 V~ 50 Hz
Absorption 1.1 A 1.1 A Thrust 3000 N 3000 N Max run 350 mm 500 mm Opening time 22 s / 90° 32 s / 90° Service class 4 - INTENSIVE 4 - INTENSIVE
Intermittence
S2 = 20 min S3 = 50%
S2 = 20 min S3 = 50%
Temperature min -20° C max +55° C min -20° C max +55° C Degree of protection IP24D IP24D Control panel E2 - LOGICM E2 - LOGICM
Applications
m = leaf width kg = leaf weight
Limit dimensions
Recommended dimensions
500 kg
400 kg
300 kg
200 kg
100 kg
500 kg
400 kg
300 kg
200 kg
100 kg
m12345
m1 2 3 4 5
LUXO5BH
LUXO5VBH
S2 = 20 min S3 = 50%
500 kg
400 kg
300 kg
200 kg
100 kg
m1 2 3 4 5
IP2128EN - 2014-02-17
23