DISPLAY ELEKTRONIK LCD-128X64GN AB Datasheet

DEM 128064B SYH
PY
DISPLAY Elektronik GmbH
LCD MODULE
Product Specification
04.06.2014
Version: 4.1.4
DEM 128064B SYH-PY Product Specification
GENERAL SPECIFICATION
MODULE NO. :
DEM 128064B SYH-PY
CUSTOMER P/N
VERSION CHANGE DESCRIPTION DATE
0 ORIGINAL VERSION 15.03.2004
1 CHANGE EXTERNAL DIMENSIONS 06.04.2004
CHANGED PCB DRAWING AND
2
DESCRIPTION
3 ADD VERSION 28.06.2005
4 MODIFY PCB DESCRIPTION 24.03.2006
4.1.0 Change IC 17.06.2008
4.1.1 Change BACKLIGHT DRAWING 04.11.2008
4.1.2 CHANGE AC CHARACTERISTICS 21.05.2014
4.1.3 Change BACKLIGHT DRAWING 04.06.2014
4.1.4 Change BACKLIGHT DRAWING 04.06.2014
05.07.2004
PREPARED BY: AFA DATE: 04.06.2014
APPROVED BY: MH DATE: 04.06.2014
Version: 4.1.4 Page 1
DEM 128064B SYH-PY Product Specification
1. FUNCTIONS & FEATURES ......................................................................................................................... 3
2. MECHANICAL SPECIFICATIONS ............................................................................................................. 3
3. EXTERNAL DIMENSIONS........................................................................................................................... 4
5.PIN ASSIGNMENT .......................................................................................................................................... 5
6.1PCB DRAWING AND DESCRIPTION ....................................................................................................... 6
7.ABSOLUTE MAXIMUM RATINGS( TA=25°C) ......................................................................................... 8
8. POWER SUPPLY FOR LCD MODULE ...................................................................................................... 8
9. ELECTRICAL CHARACTERISTICS ......................................................................................................... 9
10. DISPLAY CONTROL INSTRUCTION .................................................................................................... 12
11. BACKLIGHT ELECTRICAL/OPTICAL SPECIFICATIONS .............................................................. 15
12. OTHERS ....................................................................................................................................................... 16
Version: 4.1.4 Page 2
DEM 128064B SYH-PY Product Specification
1. FUNCTIONS & FEATURES
MODULE LCD TYPE REMARK
DEM 128064 SYH-PY STN Yellow Green Transflective Positive Mode ROHS
l Viewing Direction : 6 O’clock
l Driving Scheme : 1/64 Duty Cycle, 1/9 Bias
l Power Supply Voltage : 5.0 Volt (typ.)
l Backlight : LED, Lightguide, Yellow Green
l VLCD Adjustable For Best Contrast : 12.9 Volt (typ.)
l Display Format : 128 x 64 Dots
l Interface : 8 bit parallel display data from MPU
l Operating Temperature : -20°C to +70°C
l Storage Temperature : -30°C to +80°C
2. MECHANICAL SPECIFICATIONS
l Module Size : 75.00 x 52.70 x 9.60 mm
l Dot Size : 0.40 x 0.40 mm
l Dot Pitch : 0.43 x 0.43 mm
l Dot Gap : 0.03 mm
Version: 4.1.4 Page 3
DEM 128064B SYH-PY Product Specification
3. EXTERNAL DIMENSIONS
4. BLOCK DIAGRAM
Version: 4.1.4 Page 4
DEM 128064B SYH-PY Product Specification
5. PIN ASSIGNMENT
Pin No. Symbol Function
1 VDD 2 VSS 3 V0 4 DB0 5 DB1 6 DB2 7 DB3 8 DB4 9 DB5
10 DB6
11 DB7 12 CS1 Chip select signal for IC1 13 CS2 Chip select signal for IC2 14 /RST Reset
15 R/W
16 D/I 17 E 18 VEE POWER SUPPLY FOR LCD DRIVING 19 LED + (A) 20 LED – (K)
POWER SUPPLY FOR LOGIC CIRCUIT GND OPERATING VOLTAGE FOR LCD DRIVING
DATE BUS. Three state I/O port.
H:DATA READ (LCMMPU) L:DATA WRITE (LCMMPU)
H:DATA INPUT;L:INSTRUCTION CODE INPUT
enable
Please refer to 6.1 drawing and description.
Version: 4.1.4 Page 5
DEM 128064B SYH-PY Product Specification
6.1 PCB DRAWING AND DESCRIPTION
DESCRIPTION:
6-1-1.The polarity of the pin 19 and the pin 20:
J3,J5 J2, J4
Each open Each close Anode Cathode
Each close Each open Cathode Anode
Note: In application module, J3=J5=open, J2=J4=closed
6-1-2.The LED resistor can be bridged when the J6 is closed.
Note: In application module, J6=open
6-1-3.The R8, R9 and R10 are the LED resistor.
Note: In application module, R8=R9=R10=24Ohm
6-1-4. The metal-bezel is set on ground when the J1 is closed.
Note: In application module, J1=closed
LED Polarity
19 Pin 20 Pin
Version: 4.1.4 Page 6
DEM 128064B SYH-PY Product Specification
R8
JJ4
6.2 Example application
6-2-1. The LED resistor should be bridged as following.
6-2-2. The 19 pin is the anode and the 20 pin is the cathode as following.
6-2-3.The 19 pin is the cathode and the 20 pin is the anode as following.
R10
R9
J6
6-2-4.The metal-bezel is ground as following.
Version: 4.1.4 Page 7
DEM 128064B SYH-PY Product Specification
7. Absolute Maximum Ratings (Ta=25°C)
ITEM SYMBOL MIN. TYP. MAX. UNIT
OPERATIONG TEMPERATURE TOP -20 --- +70
STORAGE TEMPERATURE TST -30 --- +80
INPUT VOLTAGE VI VSS --- VDD V
SUPPLY VOLTAGE FORLOGIC VDD- VSS -0.3 --- 7.0 V
SUPPLY VOLTAGE FOR LCD VDD- V0 -0.3 --- 19.0 V
STATIC ELECTRICITY Be sure that you are grounded when handling LCM
8. POWER SUPPLY FOR LCD MODULE
8.1 External Power Supply Circuit 8.2 Internal Power Supply Circuit
VDD-V0 (VLCD): LCD Driving Voltage VDD-V0 (VLCD): LCD Driving Voltage
Version: 4.1.4 Page 8
DEM 128064B SYH-PY Product Specification
9. ELECTRICAL CHARACTERISTICS
9-1 DC Characteristics (VDD=+5±10% Vss=0V, Ta=-20~+70°C)
Standard Value
Item Symbol
MIN TYP MAX
Supply Current for Logic VDD 4.5 5.0 5.5
Supply Current for Logic IDD ---- 2.62 4 ------- mA
13.4 14.1 14.8 -20℃
Operating Voltage for LCD VDD-V0
11.0 11.7 12.4 70℃
Input Voltage “H” level VIH 0.7VDD --- VDD --- V
Input Voltage “L” level VIL 0 --- 0.3VDD --- V
Test
Condition
-------
Unit
V
V 12.2 12.9 13.6 25℃
Version: 4.1.4 Page 9
DEM 128064B SYH-PY Product Specification
9-2 AC Characteristics
9-2-1. AC timing for writing to the SBN0064G (VDD = 5 V; VSS = 0 V; Tamb = 25°C)
Version: 4.1.4 Page 10
DEM 128064B SYH-PY Product Specification
9-2-2. AC timing for reading from the SBN0064G (VDD = 5 V; VSS = 0 V; Tamb = 25°C.)
Version: 4.1.4 Page 11
DEM 128064B SYH-PY Product Specification
RESET
10. DISPLAY CONTROL INSTRUCTION
Registers and their states after hardware RESET
The SBN0064G has 5 registers. Four of them must be programmed by the host microcontroller after hardware reset. The
Status Register can be read by the host microcontroller to check the current status of the SBN0064G.
The registers and their states after RESET is given in Table 5.
Table 1 Registers and their states after RESET
Register Name Description States after
Display ON/OFF Register
Display Start Line Register its value is 00 0000 and, therefore, Row 0 of the Display Data 00 0000
Page Address Register
Column Address Register The Column Address Register is a 6-bit register. xx xxxx
Status Register It is a 3-bit register, with each bit showing the status of a 0010 0000
The Display ON/OFF Register is a 1-bit register. After RESET, its value is LOW and, therefore, the LCD display is turned OFF.
The Display Start Line Register is a 6-bit register. After RESET,
Memory is mapped to COM0 of LCD panel.
The Page Address Register is a 3-bit register. It point to a page of the Display Data Memory.
The Status Register shows the current state of the SBN0064G.
programmed function.
0
xxx
10-1. Display ON/OFF and the Display ON/OFF Register
Table 2 Setting of the control bus for programming the Display ON/OFF Register
C/D R/W
0 0
Table 3 Setting of the data bus for programming the Display ON/OFF Register
D7(MSB) D6 D5 D4 D3 D2 D1 D0(LSB)
0 0 1 1 1 1 1 D0
When D0=1, the code is 3F(Hex) and the display is turned ON. When D0=0, the code is 3E(Hex) and the display is turned
OFF.
10-2. Display Start Line and the Display Start Line Register
Table 4 The setting of the control bus for programming the Display Start Line Register
C/D R/W
0 0
Table 5 The setting of the data bus for programming the Display Start Line Register
D7(MSB) D6 D5 D4 D3 D2 D1 D0(LSB)
1 1 A5 A4 A3 A2 A1 A0
A5 ~ A0 are Display Start Line address bits and can be programmed with a value in the range from 0 to 63. Therefore,
the code can be from 1100 0000 (C0 Hex) to 1111 1111 (FF Hex).
Version: 4.1.4 Page 12
DEM 128064B SYH-PY Product Specification
10-3. Display Data Memory Page and the Page Address Register
Table 6 The setting of the control bus for programming the Page Address Register
C/D R/W
0 0
Table 7 The setting of the data bus for programming the Page Address Register
D7(MSB) D6 D5 D4 D3 D2 D1 D0(LSB)
1 0 1 1 1 A2 A1 A0
A2, A1and A0 are page address bits and can be programmed with a value in the range from 0 to 7. A2 A1 A0=000 selects
Page 0; A2 A1 A0=001 selects Page 1; A2 A1 A0=010 selects Page 2, and A2 A1 A0=011 selects Page 3...etc.
Therefore, the code can be from 1011 1000 (B8 Hex) to 1011 1111 (BF Hex).
10-4. Column address and the Column Address Register
Table 8 The setting of the control bus for programming the Column Address Register
C/D R/W
0 0
Table 9 The setting of the data bus for programming the Column Address Register
D7(MSB) D6 D5 D4 D3 D2 D1 D0(LSB)
0 1 A5 A4 A3 A2 A1 A0
A5~A0 are column address bits and can be programmed with a value in the range from 0 to 63. Therefore, the code can
be from 0100 0000 (40 Hex) to 0111 1111 (7F Hex).
10-5. Status Read and Status Register
Table 10 The setting of the control bus for reading the Status Register
C/D R/W
0 1
Table 11 The Status Register bit allocation
D7(MSB) D6 D5 D4 D3 D2 D1 D0(LSB)
BUSY 0 ON/OFF RESET 0 0 0 0
Table 12 The Status Register bit description
Bit Description
BUSY BUSY=1 indicates that the SBN0064G is currently busy and can not accept new code or data. The
SBN0064G is executing an internal operation.
ON/OFF The ON/OFF bit indicates the current of status of display.
RESET RESET=1 indicates that the SBN0064G is currently in the process of being reset.
BUSY=0 indicates that the SBN0064G is not busy and is ready to accept new code or data.
If ON/OFF=0, the display has been turned ON.
If ON/OFF=1, the display has been turned OFF.
Note that the polarity of this bit is inverse to that of the Display ON/OFF Register.
RESET=0 indicates that the SBN0064G is currently in normal operation.
Version: 4.1.4 Page 13
DEM 128064B SYH-PY Product Specification
10-6. READ OR WRITE OPERATION TO THE DISPLAY DATA MEMORY
Table 13 READ/WRITE operation
Table 14 The setting of the control bus for Write Display Data operation
C/D R/W
1 0
Table 15 The setting of the control bus for Read Display Data command
C/D R/W
1 1
Version: 4.1.4 Page 14
DEM 128064B SYH-PY Product Specification
11. BACKLIGHT ELECTRICAL/OPTICAL SPECIFICATIONS
REMARKS:
1.UNMARKED TOLERANCE ±0.3;
2.THE MATERIAL COMPLY WITH ROHS;
3.:CRITICAL DIMENSION;
4.COLOR:YELLOW-GREEN;
5.THE LIFETIME OF LED:30000h.
4.1~4.4
Version: 4.1.4 Page 15
DEM 128064B SYH-PY Product Specification
12. LCD MODULES HANDLING PRECAUTIONS
n Please remove the protective foil of polarizer before using. n The display panel is made of glass. Do not subject it to a mechanical shock by dropping it from a high
place, etc.
n If the display panel is damaged and the liquid crystal substance inside it leaks out, do not get any in
your mouth. If the substance come into contact with your skin or clothes promptly wash it off using soap and water.
n Do not apply excessive force to the display surface or the adjoining areas since this may cause the color
tone to vary.
n The polarizer covering the display surface of the LCD module is soft and easily scratched. Handle this
polarize carefully.
n To prevent destruction of the elements by static electricity, be careful to maintain an optimum work
environment.
-Be sure to ground the body when handling the LCD module.
-Tools required for assembly, such as soldering irons, must be properly grounded.
-To reduce the amount of static electricity generated, do not conduct assembly and other work under dry conditions.
-The LCD module is coated with a film to protect the display surface. Exercise care when peeling off this protective film since static electricity may be generated.
n Storage precautions
When storing the LCD modules, avoid exposure to direct sunlight or to the light of fluorescent lamps. Keep the modules in bags designed to prevent static electricity charging under low temperature / normal humidity conditions (avoid high temperature / high humidity and low temperatures below 0°C). Whenever possible, the LCD modules should be stored in the same conditions in which they were shipped from our company.
13. OTHERS
n Liquid crystals solidify at low temperature (below the storage temperature range) leading to defective
orientation of liquid crystal or the generation of air bubbles (black or white). Air bubbles may also be generated if the module is subjected to a strong shock at a low temperature.
n If the LCD modules have been operating for a long time showing the same display patterns may remain
on the screen as ghost images and a slight contrast irregularity may also appear. Abnormal operating status can be resumed to be normal condition by suspending use for some time. It should be noted that this phenomena does not adversely affect performance reliability.
n To minimize the performance degradation of the LCD modules resulting from caused by static
electricity, etc. exercise care to avoid holding the following sections when handling the modules:
- Exposed area of the printed circuit board
- Terminal electrode sections
Version: 4.1.4 Page 16