Displaydata 120 0194 User Manual

Page 1 of 5 © 2017 Displaydata Ltd
Aura and Chroma User Installation Guide
Document Number:
Date:
06 Nov 2018
Table of Contents
Table of Contents _____________________________________________________________ 1 1 Label shelf installation _____________________________________________________ 2
1.1 Aura and Chroma mounting position _____________________________________________ 2
1.2 Chroma 16 mounting orientation. _______________________________________________ 2
1.3 Aura 21/29 and Chroma 21/29/37 mounting orientation. _____________________________ 2
1.4 Aura 42 and Chroma 42/60/74 mounting orientation. _______________________________ 2
1.5 Aura and Chroma fixing angle. _________________________________________________ 2
2 Low temperature label variant deployment _____________________________________ 2 3 FCC Warning Statement ____________________________________________________ 3 4 Radio Equipment – Canadian Warning Statements ______________________________ 3 5 Radio Equipment – Mexico Regulatory Statement _______________________________ 4 6 North American approval detail ______________________________________________ 4 7 Battery Caution Statements__________________________________________________ 5
Page 2 of 5 © 2017 Displaydata Ltd
1 Label shelf installation
1.1 Aura and Chroma mounting position
The label should be mounted to the shelf edge using a shelf rail, available through Displaydata’s Fixtures & Fittings partners. It should not be mounted directly to a metal surface.
1.2 Chroma 16 mounting orientation.
The label should be mounted along the shelf edge with the front bar code below the display.
1.3 Aura 21/29, Chroma 21/29/37 and DD21X mounting orientation.
The label should be mounted with the display aligned horizontally along the shelf edge with the front bar code on the left-hand side.
1.4 Aura 42 and Chroma 42/60/74 mounting orientation.
The label can be mounted with the display in landscape or portrait orientation using the mounting bracket available through Displaydata’s Fixtures & Fittings partners.
1.5 Aura and Chroma fixing angle.
The Aura and Chroma range of Electronic shelf labels are based on EPD display technology with a viewing angle close to 180degrees.
This means that the overall readability of the screens is not subject to the fixing angle. The same vertical fixing angle can be used independent of shelf height.
2 Low temperature label variant deployment
It is very important to understand some basic principles with regard to the deployment of labels into a “Chiller” environment (temperature controlled fridges that are below 10degC).
All labels will usually be configured in a normal ambient room temperature environment (~20degC but could be as high as ~30degC). Once they have been configured onto a system, they can then be placed into a chiller unit. It is extremely important that all the labels are allowed time to thermally stabilise at the new colder temperature before any image updates are carried out.
It is essential to allow 45mins for the labels to reach thermal equilibrium before sending images to the labels.
Failure to wait for thermal equilibrium may result in a display where the text/graphics will be hard if not impossible to read.
Please note that the same thermal equilibrium time applies to moving a label from a Chiller/Freezer into a normal ambient temperature zone.