Discover DL BLUE BATTERY User Manual

DL BLUE BATTERY WARRANTY POLICY
DOCUMENT NUMBER
885-0021
885-0021 REV B
#4 -13511 Crestwood Place, Richmond, BC, V6V 2E9, Canada + 1.778.776.3288 info@discoverbattery.com
discoverbattery.com
NON-TRANSFERABLE
LIMITED PERFORMANCE WARRANTY
Discover Energy Corp. (Discover), together with its agents, dealers, and distributors, warrants to the original product purchaser (User), that your Discover Lithium Series Battery (Battery) is free from manufacturing defects that would prevent the battery from delivering unlimited cycles while maintaining at least 60% of the original Rated Wh for the earlier of the listed Base Workmanship Warranty Period or Total Energy Throughput Limit. If the original Battery is registered with Discover within 30 days of installation, the warranty will be for the earlier of the listed Extended Workmanship Warranty Period or Total Energy Throughput Limit as per the table below, subject to the terms and conditions outlined herein.
Battery
Model
BLUE SERIES G24 12V / 24V / 36V
BLUE SERIES GC12 12V / 24V 1425 kWh 4.5 MWh
(*) Extended Workmanship Warranty Requires Registration at www.discoverbattery.com/product-registration
Volts
Base Workmanship
Warranty Period
3 years
*Extended
Workmanship
Warranty Period
5 years with
registration
Annual Energy
Throughput Limit
725 kWh 2.2 MWh
Total Energy
Throughput Limit
Definitions
“Annual Energy Throughput” means the aggregate energy charged and discharged through the Battery as logged by the on-board data logger over one year.
“Base Workmanship Warranty Period” means the total period in years from the initial installation date that the Battery is covered by this Warranty.
“Extended Workmanship Warranty Period” means the total period in years from the initial installation date that the Battery is covered by this Warranty. (Requires Registration within 30 days of installation)
“Rated Wh” means the Battery’s nominal rated Watt-hour (Wh) energy at the time of manufacture and published in Discover’s technical documentation.
“Stationary Renewable Energy Storage Application” means the Battery application, typically off-grid solar, micro-grid or backup power, where the Battery is operated in a fixed and stationary position.
“Total Energy Throughput” means the total energy charged and discharged through the Battery as logged by the on-board data logger.
LIMITATION ON APPLICATIONS
Without the involvement of Discover in system design and Discover’s express written authorization, the Battery is not intended for use in a Stationary Renewable Energy Storage application, as a primary or backup power source for life support systems or other medical equipment, or any application where product failure could lead to injury to persons, loss of life or catastrophic property damage. To the extent permitted by law, Discover disclaims any and all liability arising out of any such use. Further, Discover reserves the right to refuse to service any Battery used for these purposes and disclaims any and all liability arising out of Discover’s refusal to service.
#4 -13511 Crestwood Place, Richmond, BC, V6V 2E9, Canada + 1.778.776.3288 info@discoverbattery.com
discoverbattery.com
Loading...
+ 3 hidden pages